Search NASA⌕ Search

SEARCH · Search NASA

Results for “FORCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Investigation of Calibrating Force Transducer Using Sinusoidal Force

Sinusoidal force calibration method was studied several years before at Physikalisch-Technische Bundesanstalt (PTB). A similar dynamic force calibration system is developed at Changcheng Institute of Metrology and Measurement (CIMM). It uses electro-dynamic shakers to generate dynamic force in the range from 1 N to 20 kN, and heterodyne laser interferometers are used for acceleration measurement. The force transducer to be calibrated is mounted on the shaker, and a mass block is screwed on the top of force transducer, the sinusoidal forces realized by accelerated load masses are traceable to acceleration and mass according to the force definition. The methods of determining Spatial-dependent acceleration on mass block and measuring the end mass of force transducer in dynamic force calibration are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the dependence of SCM simulated precipitation and clouds on the spatial scale of large-scale forcing at SGP [Investigating the scale dependence of SCM simulated precipitation and cloud by using gridded forcing data at SGP]

Large-scale forcing data, such as vertical velocity and advective tendencies, are required to drive single-column models (SCMs), cloud-resolving models, and large-eddy simulations. Previous studies suggest that some errors of these model simulations could be attributed to the lack of spatial variability in the specified domain-mean large-scale forcing. This study investigates the spatial variability of the forcing and explores its impact on SCM simulated precipitation and clouds. A gridded large-scale forcing data during the March 2000 Cloud Intensive Operational Period at the Atmospheric Radiation Measurement program's Southern Great Plains site is used for analysis and to drive the single-column version of the Community Atmospheric Model Version 5 (SCAM5). When the gridded forcing data show large spatial variability, such as during a frontal passage, SCAM5 with the domain-mean forcing is not able to capture the convective systems that are partly located in the domain or that only occupy part of the domain. This problem has been largely reduced by using the gridded forcing data, which allows running SCAM5 in each subcolumn and then averaging the results within the domain. This is because the subcolumns have a better chance to capture the timing of the frontal propagation and the small-scale systems. As a result, other potential uses of the gridded forcing data, such as understanding and testing scale-aware parameterizations, are also discussed.

58 GEOSCIENCES↗

Impact of surface imperfections on the Casimir force for lenses of centimeter-size curvature radii

The impact of imperfections, which are always present on surfaces of lenses with centimeter-size curvature radii, on the Casimir force in the lens-plate geometry is investigated. It is shown that the commonly used formulation of the proximity force approximation is inapplicable for spherical lenses with surface imperfections, such as bubbles and pits. More general expressions for the Casimir force are derived that take surface imperfections into account. Using these expressions, we show that surface imperfections can both increase and decrease the magnitude of the Casimir force up to a few tens percent when compared with the case of a perfectly spherical lens. We demonstrate that the Casimir force between a perfectly spherical lens and a plate described by the Drude model can be made approximately equal to the force between a sphere with some surface imperfection and a plate described by the plasma model, and vice versa. In the case of a metallic sphere and a semiconductor plate, approximately the same Casimir forces are obtained for four different descriptions of charge carriers in the semiconductor if appropriate surface imperfections on the lens surface are present. The conclusion is made that there is a fundamental problem in the interpretation of measurement data for the Casimir force using spherical lenses of centimeter-size radii.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Viscoelastic-Mapping of Cellulose Nanofibrils Using Low-Total-Force Contact Resonance Force Microscopy (LTF-CRFM)

Low-total-force contact resonance force microscopy (LTF-CRFM), an atomic force microscopy method, is introduced as a non-destructive means to quantify the local viscoelastic loss tangent (tan..delta..) of supported cellulose nanofibrils (CNFs). The method limits static and dynamic forces during measurement to minimize substrate and geometry effects and to reduce the potential for stress-induced CNF damage. LTF-CRFM uses Brownian motion to achieve the thermally-limited lowest dynamic force, while approaching adhesive pull-off to achieve the low static force. LTF-CRFM measurements were shown to generate analyzable data without evidence of nonlinear artifacts and without damage to the CNF over static forces ranging from 11.6 to 84.6 nN. The measured tan..delta.. of CNFs was 0.015 +/- 0.0094, which is the first reported tan..delta.. measurement of an isolated CNF. Finally, LTF-CRFM successfully mapped tan..delta.. along the length of CNFs to determine that kink defects along the CNF do not impart a local viscoelastic property change at the spatial resolution of the measurement.

BIOMASS FUELS↗

Synthesizing new modes for subsurface atomic force microscopy

Non-destructive, nanoscale characterization techniques are needed to understand both synthetic and biological materials. The atomic force microscope uses a force-sensing cantilever with a sharp tip to measure the topography and other properties of surfaces. As the tip is scanned over the surface it experiences attractive and repulsive forces that depend on the chemical and mechanical properties of the sample. Here we show that an atomic force microscope can obtain a range of surface and subsurface information by making use of the nonlinear nanomechanical coupling between the probe and the sample. This technique, which is called mode-synthesizing atomic force microscopy, relies on multi-harmonic forcing of the sample and the probe. A rich spectrum of first- and higher-order couplings is discovered, providing a multitude of new operational modes for force microscopy, and the capabilities of the technique are demonstrated by examining nanofabricated samples and plant cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization and calibration of atomic force microscopy sensitivity in terms of tip-sample interactions in high-order dynamic atomic force microscopy

The mechanism of dynamic force modes has been successfully applied to many atomic force microscopy (AFM) applications, such as tapping mode and phase imaging. The high-order flexural vibration modes are recent advancement of AFM dynamic force modes. AFM optical lever detection sensitivity plays a major role in dynamic force modes because it determines the accuracy in mapping surface morphology, distinguishing various tip-surface interactions, and measuring the strength of the tip-surface interactions. In this work, we have analyzed optimization and calibration of the optical lever detection sensitivity for an AFM cantilever-tip ensemble vibrating in high-order flexural modes and simultaneously experiencing a wide range and variety of tip-sample interactions. It is found that the optimal detection sensitivity depends on the vibration mode, the ratio of the force constant of tip-sample interactions to the cantilever stiffness, as well as the incident laser spot size and its location on the cantilever. It is also found that the optimal detection sensitivity is less dependent on the strength of tip-sample interactions for high-order flexural modes relative to the fundamental mode, i.e., tapping mode. When the force constant of tip-sample interactions significantly exceeds the cantilever stiffness, the optimal detection sensitivity occurs only when the laser spot locates at a certain distance from the cantilever-tip end. Thus, in addition to the 'globally optimized detection sensitivity', the 'tip optimized detection sensitivity' is also determined. Finally, we have proposed a calibration method to determine the actual AFM detection sensitivity in high-order flexural vibration modes against the static end-load sensitivity that is obtained traditionally by measuring a force-distance curve on a hard substrate in the contact mode.

36 MATERIALS SCIENCE↗

High-speed force mapping on living cells with a small cantilever atomic force microscope

The imaging speed of the wide-spread force mapping mode for quantitative mechanical measurements on soft samples in liquid with the atomic force microscope (AFM) is limited by the bandwidth of the z-scanner and viscous drag forces on the cantilever. Here, we applied high-speed, large scan-range atomic force microscopy and small cantilevers to increase the speed of force mapping by ≈10−100 times. This allowed resolving dynamic processes on living mouse embryonic fibroblasts. Cytoskeleton reorganization during cell locomotion, growth of individual cytoskeleton fibers, cell blebbing, and the formation of endocytic pits in the cell membrane were observed. Increasing the force curve rate from 2 to 300 Hz increased the measured apparent Young's modulus of the cells by about 10 times, which facilitated force mapping measurements at high speed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Response of Precipitation Extremes to the Twentieth- and Twenty-First-Century Global Temperature Change in a Comprehensive Suite of CESM1 Large Ensemble Simulation: Revisiting the Role of Forcing Agents Vs. the Role of Forcing Magnitudes

The response of precipitation extremes (PEs) to global warming is found to be nonlinear in Community Earth System Model version 1 (CESM1) and other global climate models (Pendergrass et al., 2019), which led to the concern that it is not accurate to approximate the response of PE to a single forcing as the difference between simulations with all forcing agents and those that exclude one specific forcing. This calls into question previous model-based results that the sensitivity of PE with warming due to aerosol forcing is significantly larger than that due to greenhouse gases (GHGs). We reevaluate the PE sensitivity to GHGs and aerosols using available CESM1 ensemble simulations. We show that although the PE response to warming is nonlinear in CESM1, especially for the high warming projected in the twenty-first-century, PE sensitivity to aerosols is still significantly stronger than that due to GHGs when the comparison is made within similar warming regimes to avoid the bias induced by the nonlinear behavior. But the difference is smaller than previously estimated. We also conclude that the additivity assumption is largely valid to isolate the PE response due to aerosol forcing from the paired simulations including the “all forcing” experiment when the warming regime is small (e.g., 1°C–2°C in the next few decades when aerosol forcing is projected to decline and becomes a major source of uncertainty for model projection).

58 GEOSCIENCES↗

Observational determination of surface radiative forcing by CO 2 from 2000 to 2010

The climatic impact of CO 2 and other greenhouse gases is usually quantified in terms of radiative forcing, calculated as the difference between estimates of the Earth's radiation field from pre-industrial and present-day concentrations of these gases. Radiative transfer models calculate that the increase in CO 2 since 1750 corresponds to a global annual-mean radiative forcing at the tropopause of 1.82 ± 0.19 W m -2 . However, despite widespread scientific discussion and modelling of the climate impacts of well-mixed greenhouse gases, there is little direct observational evidence of the radiative impact of increasing atmospheric CO 2 . Here in this paper, we present observationally based evidence of clear-sky CO 2 surface radiative forcing that is directly attributable to the increase, between 2000 and 2010, of 22 parts per million atmospheric CO 2 . The time series of this forcing at the two locations-the Southern Great Plains and the North Slope of Alaska-are derived from Atmospheric Emitted Radiance Interferometer spectra together with ancillary measurements and thoroughly corroborated radiative transfer calculations. The time series both show statistically significant trends of 0.2 W m -2 per decade (with respective uncertainties of ± 0.06 W m -2 per decade and ± 0.07 W m -2 per decade) and have seasonal ranges of 0.1-0.2 W m -2 . This is approximately ten per cent of the trend in downwelling longwave radiation. These results confirm theoretical predictions of the atmospheric greenhouse effect due to anthropogenic emissions, and provide empirical evidence of how rising CO 2 levels, mediated by temporal variations due to photosynthesis and respiration, are affecting the surface energy balance.

54 ENVIRONMENTAL SCIENCES↗

INTEGRATION OF FLEX EQUIPMENT AND OPERATOR ACTIONS IN PLANT FORCE-ON-FORCE MODELS WITH DYNAMIC RISK ASSESSMENT

The overall operation and maintenance cost to protect nuclear power plants accounts for approximately 7% of the total cost of power generation, with labor accounting for half of this cost. In the current research, from interaction with utilities and other stakeholders, it was determined that physical security forces account for nearly 20% of the entire workforce at several nuclear power plants. Labor costs continue to rise in the U.S., so any measures to reduce the cost of operating a nuclear power plant will need to include a reduction in labor. The physical security pathway within the DOE’s Light Water Reactor Sustainability program aims to lower the cost of physical security through directed research into modeling and simulation, application of advanced sensors or deployment of advanced weapons. This report presents a modeling and simulation framework for integrating Diverse and Flexible Mitigation Capability (FLEX) portable equipment performance with Force on Force models of a plant’s physical security posture. The generic framework is described in detail, followed by a case study of modeling an adversarial attack aimed at causing a radiological release by sabotaging the plant’s power supply and its ultimate heat sink capabilities at a hypothetical nuclear power plant. Two different FLEX deployment strategies, series and parallel, are modeled with distinct timelines. The results of the adversarial attack modeled in a commercial Force on Force tool are integrated with the FLEX deployment model in INL’s dynamic modeling tool EMRALD. Monte Carlo simulation is used to model the distribution of the timeline in FLEX deployment strategies. The results demonstrate that, even in the extreme case of a successful adversarial attack, deployment of FLEX equipment can result in a significantly high likelihood of preventing radiological release. The modeling and simulation framework integrating FLEX equipment with Force on Force models enables the nuclear power plants to credit FLEX portable equipment in the plant security posture, resulting in an efficient and optimized physical security.

97 MATHEMATICS AND COMPUTING↗

Optical properties and radiative forcing of fractal-like tar ball aggregates from biomass burning

Tar balls are frequently found in slightly aged biomass burning plumes. They are spherical in shape, have diameters between ~100 and 300 nm, are amorphous and composed mostly of oxygen and carbon. Tar balls are light absorbing and considered to be a component of brown carbon. Tar balls have been typically reported and analyzed as individual spheres; however, in a recent study, we reported the presence of significant fractions of fractal-like tar ball aggregates in fire plumes from different geographical locations. Aggregation affects the optical properties of particles; therefore, we use T-Matrix and Lorenz-Mie simulations to explore the effects of aggregation on the tar balls’ optical properties in the 350 – 1150 nm wavelength range. We also evaluate the effects of different index of refraction values available from the literature, different monomer numbers, and monomer sizes, as these are key factors determining the aggregates optical properties. Furthermore, we estimate the direct radiative forcing for low and high surface albedos. The single scattering albedo of aggregates exceed by up to 77% that of individual tar balls. The hemispherical upscatter fraction of tar ball aggregates are more than 100% larger than for individual tar balls in many cases. The top of the atmosphere simple forcing efficiency over dark surfaces shows large variabilities with differences up to ~53% between the tar ball aggregates and individual tar balls. These results demonstrate that aggregation of tar balls can have a significant impact on their optical properties and radiative forcing.

Tar balls, aggregates, brown carbon, biomass burni↗

Towards High-Resolution Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry Coupled to Shear Force Microscopy

Constant mode ambient mass spectrometry imaging (MSI) of tissue sections with high lateral resolution of better than 10 μm was performed by combining shear force microscopy with nanospray desorption electrospray ionization (nano-DESI). Shear force microscopy enabled precise control of the distance between the sample and nano-DESI probe during MSI experiments and provided information on sample topography. Proof-of-concept experiments were performed using lung and brain tissue sections representing spongy and dense tissues, respectively. Topography images obtained using shear force microscopy were comparable to the results obtained using contact profilometry over the same region of the tissue section. Variations in tissue height were found to be dependent on the tissue type and were in the range of 0–5 μm for lung tissue and 0–3 μm for brain tissue sections. Ion images of phospholipids obtained in this study are in good agreement with literature data. Normalization of nano-DESI MSI images to the signal of the internal standard added to the extraction solvent allowed us to construct high-resolution ion images free of matrix effects. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of cell adhesion force by vertical forcible detachment using an arrowhead nanoneedle and atomic force microscopy

Graphical abstract: - Highlights: • We developed a method to measure cell adhesion force by detaching cell using an arrowhead nanoneedle and AFM. • A nanofilm consisting of fibronectin and gelatin was formed on cell surface to reinforce the cell cortex. • By the nanofilm lamination, detachment efficiencies of strongly adherent cell lines were improved markedly. - Abstract: The properties of substrates and extracellular matrices (ECM) are important factors governing the functions and fates of mammalian adherent cells. For example, substrate stiffness often affects cell differentiation. At focal adhesions, clustered–integrin bindings link cells mechanically to the ECM. In order to quantitate the affinity between cell and substrate, the cell adhesion force must be measured for single cells. In this study, forcible detachment of a single cell in the vertical direction using AFM was carried out, allowing breakage of the integrin–substrate bindings. An AFM tip was fabricated into an arrowhead shape to detach the cell from the substrate. Peak force observed in the recorded force curve during probe retraction was defined as the adhesion force, and was analyzed for various types of cells. Some of the cell types adhered so strongly that they could not be picked up because of plasma membrane breakage by the arrowhead probe. To address this problem, a technique to reinforce the cellular membrane with layer-by-layer nanofilms composed of fibronectin and gelatin helped to improve insertion efficiency and to prevent cell membrane rupture during the detachment process, allowing successful detachment of the cells. This method for detaching cells, involving cellular membrane reinforcement, may be beneficial for evaluating true cell adhesion forces in various cell types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative comparison of two independent lateral force calibration techniques for the atomic force microscope

Two independent lateral-force calibration methods for the atomic force microscope (AFM)--the hammerhead (HH) technique and the diamagnetic lateral force calibrator (D-LFC)--are systematically compared and found to agree to within 5% or less, but with precision limited to about 15%, using four different tee-shaped HH reference probes. The limitations of each method, both of which offer independent yet feasible paths toward traceable accuracy, are discussed and investigated. We find that stiff cantilevers may produce inconsistent D-LFC values through the application of excessively high normal loads. In addition, D-LFC results vary when the method is implemented using different modes of AFM feedback control, constant height and constant force modes, where the latter is more consistent with the HH method and closer to typical experimental conditions. Specifically, for the D-LFC apparatus used here, calibration in constant height mode introduced errors up to 14 %. In constant force mode using a relatively stiff cantilever, we observed an {approx_equal} 4 % systematic error per {mu}N of applied load for loads {<=} 1 {mu}N. The issue of excessive load typically emerges for cantilevers whose flexural spring constant is large compared with the normal spring constant of the D-LFC setup (such that relatively small cantilever flexural displacements produce relatively large loads). Overall, the HH method carries a larger uncertainty, which is dominated by uncertainty in measurement of the flexural spring constant of the HH cantilever as well as in the effective length dimension of the cantilever probe. The D-LFC method relies on fewer parameters and thus has fewer uncertainties associated with it. We thus show that it is the preferred method of the two, as long as care is taken to perform the calibration in constant force mode with low applied loads.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Artificial neural networks for the automated analysis of force map data in atomic force microscopy

Force curves recorded with the atomic force microscope on structured samples often show an irregular force versus indentation behavior. An analysis of such curves using standard contact models (e.g., the Sneddon model) would generate inaccurate Young's moduli. A critical inspection of the force curve shape is therefore necessary for estimating the reliability of the generated Young's modulus. We used a trained artificial neural network to automatically recognize curves of “good” and of “bad” quality. This is especially useful for improving the analysis of force maps that consist of a large number of force curves.

42 ENGINEERING↗

Mapping power-law rheology of living cells using multi-frequency force modulation atomic force microscopy

We present multi-frequency force modulation atomic force microscopy (AFM) for mapping the complex shear modulus G* of living cells as a function of frequency over the range of 50–500 Hz in the same measurement time as the single-frequency force modulation measurement. The AFM technique enables us to reconstruct image maps of rheological parameters, which exhibit a frequency-dependent power-law behavior with respect to G{sup *}. These quantitative rheological measurements reveal a large spatial variation in G* in this frequency range for single cells. Moreover, we find that the reconstructed images of the power-law rheological parameters are much different from those obtained in force-curve or single-frequency force modulation measurements. This indicates that the former provide information about intracellular mechanical structures of the cells that are usually not resolved with the conventional force measurement methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗