Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Synthesis of Submillimeter Radiation for Spectroscopy

The frequency-multiplier submillimeter spectrometer (FMSS) is a laboratory apparatus for far-infrared molecular spectroscopy, embodying several advances over prior such apparatuses. The most innovative part of the FMSS is a source of monochromatic submillimeter- wavelength radiation that can be tuned over a wide frequency range, as needed for trace gas analyses and molecular- structure studies for which such apparatuses are typically used. The radiation source features a modular design and is built mostly from commercially available components. It includes a computer-controlled radio-frequency synthesizer, amplifiers, and frequency multipliers of a type heretofore used in local oscillators for heterodyne far-infrared receivers. In conjunction with the rest of the apparatus, this source makes it possible to perform measurements over large portions of the submillimeter-wavelength spectrum with resolution, accuracy, and sensitivity greater than those achievable in Fourier-transform infrared spectroscopy. In comparison with prior laboratory submillimeter- wavelength radiation sources, this source is much lighter in weight, less cumbersome, less power-hungry, and capable of sustained operation with less intervention by laboratory personnel. Also, unlike some prior submillimeter-wavelength sources, this source does not require a high-voltage power source. As shown in more detail in the figure, the radiation source includes a sweep frequency synthesizer connected to an external waveform generator, the output of which is used as a reference signal. The synthesizer is computer-controlled through a standard general-purpose interface bus (GPIB) and is operated in phase-locked continuous- wave mode for all measurements. The synthesizer output ranges in frequency from 11 to 18 GHz. For suppression of frequency spurs and harmonics, the output of the frequency synthesizer is fed through a tunable yttrium iron garnet (YIG) filter, which is swept in frequency simultaneously with the frequency synthesizer.

Maiwald, Frank↗

Flagging and Correction of Pattern Noise in the Kepler Focal Plane Array

In order for Kepler to achieve its required less than 20 PPM photometric precision for magnitude 12 and brighter stars, instrument-induced variations in the CCD readout bias pattern (our "2D black image"), which are either fixed or slowly varying in time, must be identified and the corresponding pixels either corrected or removed from further data processing. The two principle sources of these readout bias variations are crosstalk between the 84 science CCDs and the 4 fine guidance sensor (FGS) CCDs and a high frequency amplifier oscillation on less than 40% of the CCD readout channels. The crosstalk produces a synchronous pattern in the 2D black image with time-variation observed in less than 10% of individual pixel bias histories. We will describe a method of removing the crosstalk signal using continuously-collected data from masked and over-clocked image regions (our "collateral data"), and occasionally-collected full-frame images and reverse-clocked readout signals. We use this same set to detect regions affected by the oscillating amplifiers. The oscillations manifest as time-varying moir pattern and rolling bands in the affected channels. Because this effect reduces the performance in only a small fraction of the array at any given time, we have developed an approach for flagging suspect data. The flags will provide the necessary means to resolve any potential ambiguity between instrument-induced variations and real photometric variations in a target time series. We will also evaluate the effectiveness of these techniques using flight data from background and selected target pixels.

Kolodziejczak, Jeffery J.↗

Measurements of the Low Frequency Gain Fluctuations of a 30 GHz High-Electron-Mobility-Transistor Cryogenic Amplifier

Low frequency gain fluctuations of a 30 GHz cryogenic HEMT amplifier have been measured with the input of the amplifier connected to a 15 K load. Effects of fluctuations of other components of the test set-up were eliminated by use of a power-power correlation technique. Strong correlation between output power fluctuations of the amplifier and drain current fluctuations of the transistors comprising the amplifier are observed. The existence of these correlations introduces the possibility of regressing some of the excess noise from the HEMT amplifier's output using the measured drain currents.

Jarosik, Norman↗

A Novel Application of Fourier Transform Spectroscopy with HEMT Amplifiers at Microwave Frequencies

The goal was to develop cryogenic high-electron-mobility transistor (HEMT) based radiometers and use them to measure the anisotropy in the cosmic microwave background (CMB). In particular, a novel Fourier transform spectrometer (FTS) built entirely of waveguide components would be developed. A dual-polarization Ka-band HEMT radiometer and a similar Q-band radiometer were built. In a series of measurements spanning three years made from a ground-based site in Saskatoon, SK, the amplitude, frequency spectrum, and spatial frequency spectrum of the anisotropy were measured. A prototype Ka-band FTS was built and tested, and a simplified version is proposed for the MAP satellite mission. The 1/f characteristics of HEMT amplifiers were quantified using correlation techniques.

Wilkinson, David T.↗

Recent advances in capacitance type of blade tip clearance measurements

Two recent electronic advances at NASA-Lewis that meet the blade tip clearance needs of a wide class of fans, compressors, and turbines are described. The first is a frequency modulated (FM) oscillator that requires only a single low cost ultrahigh frequency operational amplifier. Its carrier frequency is 42.8 MHz when used with a 61 cm long hermetically sealed coaxial cable. The oscillator can be calibrated in the static mode and has a negative peak frequency deviation of 400 kHz for a typical rotor blade. High temperature performance tests of the probe and 13 cm of the adjacent cable show good accuracy up to 600 C, the maximum which produces a clearance error of + or - 10 microns at a clearance of 500 microns. In the second advance, a guarded probe configuration allows a longer cable capacitance. The capacitance of the probe is part of a small time constant feedback in a high speed operational amplifier. The solution of the governing differential equation is applied to a ramp type of input. The results show an amplifier output that contains a term which is proportional to the derivative of the feedback capacitance. The capacitance is obtained by subtracting a balancing reference channel followed by an integration stage.

Barranger, John P.↗

Recent advances in capacitance type of blade tip clearance measurements

Two recent electronic advances at NASA-Lewis that meet the blade tip clearance needs of a wide class of fans, compressors, and turbines are described. The first is a frequency modulated (FM) oscillator that requires only a single low cost ultrahigh frequency operational amplifier. Its carrier frequency is 42.8 MHz when used with a 61 cm long hermetically sealed coaxial cable. The oscillator can be calibrated in the static mode and has a negative peak frequency deviation of 400 kHz for a typical rotor blade. High temperature performance tests of the probe and 13 cm of the adjacent cable show good accuracy up to 600 C, the maximum which produces a clearance error of + or - 10 microns at a clearance of 500 microns. In the second advance, a guarded probe configuration allows a longer cable capacitance. The capacitance of the probe is part of a small time constant feedback in a high speed operational amplifier. The solution of the governing differential equation is applied to a ramp type of input. The results show an amplifier output that contains a term which is proportional to the derivative of the feedback capacitance. The capacitance is obtained by subtracting a balancing reference channel followed by an integration stage.

Barranger, John P.↗

Crystal oscillators using negative voltage gain, single pole response amplifiers

A simple and inexpensive crystal oscillator is provided which employs negative voltage gain, single pole response amplifiers. The amplifiers may include such configurations as gate inverters, operational amplifiers and conventional bipolar transistor amplifiers, all of which operate at a frequency which is on the roll-off portion of their gain versus frequency curve. Several amplifier feedback circuit variations are employed to set desired bias levels and to allow the oscillator to operate at the crystal's fundamental frequency or at an overtone of the fundamental frequency. The oscillator is made less expensive than comparable oscillators by employing relatively low frequency amplifiers and operating them at roll-off, at frequencies beyond which they are customarily used. Simplicity is provided because operation at roll-off eliminates components ordinarily required in similar circuits to provide sufficient phase-shift in the feedback circuitry for oscillation to occur.

Kleinberg, Leonard L.↗

Discrete-vortex simulation of pulsating flow on a turbulent leading-edge separation bubble

Studies are made of the turbulent separation bubble in a two-dimensional semi-infinite blunt plate aligned to a uniform free stream with a pulsating component. The discrete-vortex method is applied to simulate this flow situation because this approach is effective for representing the unsteady motions of the turbulent shear layer and the effect of viscosity near the solid surface. The numerical simulation provides reasonable predictions when compared with the experimental results. A particular frequency with a minimum reattachment is related to the drag reduction. The most effective frequency is dependent on the amplified shedding frequency. The turbulent flow structure is scrutinized. This includes the time-mean and fluctuations of the velocity and the surface pressure, together with correlations between the fluctuating components. A comparison between the pulsating flow and the non-pulsating flow at the particular frequency of the minimum reattachment length of the separation bubble suggests that the large-scale vortical structure is associated with the shedding frequency and the flow instabilities.

Sung, Hyung Jin↗

Absolute frequency stabilization of laser oscillator against laser amplifier

Long-term absolute frequency stabilization of a laser oscillator is obtained when the lasers oscillation frequency is referenced to the exact center of an atomic transition. A laser amplifier acts as a discriminant to indicate when the laser frequency deviates from the center of its atomic transistion.

Siegman, A. E.↗

Method for ambiguity resolution in range-Doppler measurements

A method for resolving range and Doppler target ambiguities when the target has substantial range or has a high relative velocity in which a first signal is generated and a second signal is also generated which is coherent with the first signal but at a slightly different frequency such that there exists a difference in frequency between these two signals of Delta f(sub t). The first and second signals are converted into a dual-frequency pulsed signal, amplified, and the dual-frequency pulsed signal is transmitted towards a target. A reflected dual-frequency signal is received from the target, amplified, and changed to an intermediate dual-frequency signal. The intermediate dual-frequency signal is amplified, with extracting of a shifted difference frequency Delta f(sub r) from the amplified intermediate dual-frequency signal done by a nonlinear detector. The final step is generating two quadrature signals from the difference frequency Delta f(sub t) and the shifted difference frequency Delta f(sub r) and processing the two quadrature signals to determine range and Doppler information of the target.

Heymsfield, Gerald M.↗

Low phase noise oscillator using two parallel connected amplifiers

A high frequency oscillator is provided by connecting two amplifier circuits in parallel where each amplifier circuit provides the other amplifier circuit with the conditions necessary for oscillation. The inherent noise present in both amplifier circuits causes the quiescent current, and in turn, the generated frequency, to change. The changes in quiescent current cause the transconductance and the load impedance of each amplifier circuit to vary, and this in turn results in opposing changes in the input susceptance of each amplifier circuit. Because the changes in input susceptance oppose each other, the changes in quiescent current also oppose each other. The net result is that frequency stability is enhanced.

Kleinberg, Leonard L.↗

Development of a High Frequency Class-A Amplifier for High Temperature Wireless Microsystems based on a Silicon Carbide Static Induction Transistor

Next generation gas turbine engine health monitoring for high performance jet engine-powered aircraft will incorporate integrated microelectronic sensors specifically designed to enhance aircraft functionality, engine efficiency, and safety. Temperature, air flow and pressure associated with the gas path as well as emissions from the engine correlate to the state of the combustor and other engine health conditions. Monitoring these parameters accurately requires positioning electronic sensors in the hot zone of the gas turbine engine, which exposes them to temperatures in excess of 400ºC. At these temperatures, signal amplification is needed at the transducer level to distinguish the desired measured signal from the significant electronic noise generated by the harsh environment. In this presentation, we report on the simulation, development, fabrication, and testing on a high temperature Class-A amplifier which utilizes a 4H-SiC Static Induction Transistor (SIT) as the active device and input/output matching and DC bias networks comprised of thin-film spiral inductors, metal-insulator-metal capacitors, and thick film chip resistors. A small signal model that emulates the operation of the 4H-SiC SIT from 25 to 400ºC, with an emphasis on operation at 400οC, was utilized. Measurements were performed from 25 to 400ºC to generate current-voltage curves, capacitive transistor characteristics and high frequency scattering parameters (S-parameters). The measured data was used to extrapolate the transconductance, gm, as a function of temperature for model development. Circuit simulation tools were used to generate S-parameters, which were compared to the measured values. At 400οC, a maximum difference between measured and simulated S-parameters for frequencies from 20 to 100 MHz were 3.84%, 0.68%, 10.61%, and 3.26% for S21, S12, S11, and S22, respectively. The average transit frequency, ft, was calculated from measured values to be 197.8 MHz, while the simulated value from the model was found to be 200 MHz. The Amplifier’s S-parameters were recorded at 20-100 MHz over a temperature range of 25-400ºC and show a gain of approximately 15.8 and 5.80 dBm at 25 and 400ºC, respectively. The input and output reflection coefficients at 50 MHz and 400ºC were -18.5 and -15.2 dB, respectively. The noise figure and phase noise were measured over the temperature range of 25-400ºC and recorded. The noise figure increased 21% at 50 MHz over the temperature range, while the 1 kHz offset of the phase noise remained below -110 dB. The stability factor, K, calculated with measured and simulated data demonstrates unconditional stability over the frequency range at 400ºC. Lastly, the 1-dB compression point was measured at 50 MHz and 400ºC with an approximated output of 9.5 dBm.

SiC↗

Simultaneous amplification of terahertz difference frequencies by an injection-seeded semiconductor laser amplifier at 850 nm

Two-frequency operation of an 850 nm semiconductor optical amplifier was achieved by simultaneously injection seeding it with two diode lasers. The two frequencies could be independently amplified without strong interference when they were separated by more than 10 GHz, and the spectral purity was preserved by the amplification process. At frequency differences below 10 GHz, unbalanced two-frequency output was observed, which can be explained by a two-mode interaction driven by the refractive index modulation at the beat frequency. The laser system is suitable for the difference-frequency generation of coherent terahertz radiation in ultra-fast photoconductors or nonlinear optical media.

NASA Discipline Exobiology↗