Search NASA⌕ Search

SEARCH · Search NASA

Results for “FUEL CONDITIONING FACILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

MITR & NBSR DDE Irradiations in BR2 – Fluence in LEU Cladding and Structural Materials

The BR2 nuclear reactor is a material testing reactor (MTR) located in Mol, Belgium, and operated by the Belgian Nuclear Research Centre (SCK CEN) since 1963. The reactor is highly versatile as the number and location of fuel elements and control rods can change significantly from cycle to cycle to accommodate different needs. Argonne National Laboratory (ANL or Argonne) Reactor Conversion (RC) team has collaborated with SCK CEN for over a decade on the conversion of domestic and international research reactors from highly enriched uranium (HEU, ≥20 wt.% of 235 U) to low enriched uranium (LEU, <20 wt.% of 235 U) fuel. The U.S. High-Performance Research Reactor (USHPRR) project within the M3 Reactor Conversion Program aims at converting five U.S. high performance research reactors (MITR, MURR, NBSR, HFIR, and ATR) and one critical facility (ATR-C) to LEU fuel. These USHPRRs still use and regularly refuel with HEU fuel. Each facility has a unique reactor design, operating conditions, and fuel element design to accomplish its mission. The goal of the USHPRR project is to convert the USHPRRs and the critical facility to LEU fuel while maintaining experimental performance and ensuring safe facility operation. The current technical report focuses on two reactors requiring very high-density LEU fuel: the Massachusetts Institute of Technology Reactor (MITR) and the National Bureau of Standards Reactor (NBSR). To support the conversion of these reactors, so-called design demonstration elements (DDE) are planned to be irradiated in the BR2 reactor under conditions similar to the targeted reactors and using a prototypic geometry. In support of this experiment, SCK CEN studied and modeled the DDE irradiations using MCNP6.2 to investigate the feasibility of irradiating the MITR DDE and NBSR DDE in BR2. Argonne reviewed and confirmed the conclusions of this study. Structural analysis is another step toward converting USHPRR to LEU fuel. The objective of the current report is to provide information useful to the structural analysis of the NBSR & MITR DDEs to support its irradiation in BR2. Specifically, the goal is to provide the fast neutron (E>0.1MeV) fluence in the cladding of the fuel plates in BR2 for the whole period of irradiation (8 cycles for MITR DDE and 10 cycles for NBSR DDE). Additionally, fast neutron fluences in the side plates and in the NBSR DDE’s outside plates were calculated and reported. Neutronic calculations were performed using MCNP6.2 on the RTRHPC cluster.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multivariate analysis of gamma spectra to characterize used nuclear fuel

Abstract—The Multi-Isotope Process (MIP) Monitor provides an efficient approach to monitoring the process conditions in used nuclear fuel reprocessing facilities to support process verification and validation. The MIP Monitor applies multivariate analysis to gamma spectroscopy of reprocessing streams in order to detect small changes in the gamma spectrum, which may indicate changes in process conditions. This research extends the MIP Monitor by characterizing a used fuel sample after initial dissolution according to the type of reactor of origin (pressurized or boiling water reactor), initial enrichment, burn up, and cooling time. Simulated gamma spectra were used to develop and test three fuel characterization algorithms. The classification and estimation models employed are based on the partial least squares regression (PLS) algorithm. A PLS discriminate analysis model was developed which perfectly classified reactor type. Locally weighted PLS models were fitted on-the-fly to estimate continuous fuel characteristics. Burn up was predicted within 0.1% root mean squared percent error (RMSPE) and both cooling time and initial enrichment within approximately 2% RMSPE. This automated fuel characterization can be used to independently verify operator declarations of used fuel characteristics and inform the MIP Monitor anomaly detection routines at later stages of the fuel reprocessing stream to improve sensitivity to changes in operational parameters and material diversions.

Multivariate Analysis for Characterization of Used↗

Preliminary Results of Ancillary Safety Analyses Supporting TREAT LEU Conversion Activities

The Transient Reactor Test Facility (TREAT), located at Idaho National Laboratory (INL), is a test facility designed to evaluate the performance of reactor fuels and materials under transient accident conditions. The facility, an air-cooled, graphite-moderated reactor designed to utilize fuel containing high-enriched uranium (HEU), has been in non-operational standby status since 1994. Currently, in support of the missions of the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Material Management and Minimization (M3) Reactor Conversion Program, a new core design is being developed for TREAT that will utilize low-enriched uranium (LEU). The primary objective of this conversion effort is to design an LEU core that is capable of meeting the performance characteristics of the existing HEU core. Minimal, if any, changes are anticipated for the supporting systems (e.g. reactor trip system, filtration/cooling system, etc.); therefore, the LEU core must also be able to function with the existing supporting systems, and must also satisfy acceptable safety limits. In support of the LEU conversion effort, a range of ancillary safety analyses are required to evaluate the LEU core operation relative to that of the existing facility. These analyses cover neutronics, shielding, and thermal hydraulic topics that have been identified as having the potential to have reduced safety margins due to conversion to LEU fuel, or are required to support the required safety analyses documentation. The majority of these ancillary tasks have been identified in [1] and [2]. The purpose of this report is to document the ancillary safety analyses that have been performed at Argonne National Laboratory during the early stages of the LEU design effort, and to describe ongoing and anticipated analyses. For all analyses presented in this report, methodologies are utilized that are consistent with, or improved from, those used in analyses for the HEU Final Safety Analysis Report (FSAR) [3]. Depending on the availability of historical data derived from HEU TREAT operation, results calculated for the LEU core are compared to measurements obtained from HEU TREAT operation. While all analyses in this report are largely considered complete and have been reviewed for technical content, it is important to note that all topics will be revisited once the LEU design approaches its final stages of maturity. For most safety significant issues, it is expected that the analyses presented here will be bounding, but additional calculations will be performed as necessary to support safety analyses and safety documentation. It should also be noted that these analyses were completed as the LEU design evolved, and therefore utilized different LEU reference designs. Preliminary shielding, neutronic, and thermal hydraulic analyses have been completed and have generally demonstrated that the various LEU core designs will satisfy existing safety limits and standards also satisfied by the existing HEU core. These analyses include the assessment of the dose rate in the hodoscope room, near a loaded fuel transfer cask, above the fuel storage area, and near the HEPA filters. The potential change in the concentration of tramp uranium and change in neutron flux reaching instrumentation has also been assessed. Safety-significant thermal hydraulic items addressed in this report include thermally-induced mechanical distortion of the grid plate, and heating in the radial reflector.

Brunett, A. J.↗

NOx formation from the combustion of monodisperse n-heptane sprays doped with fuel-nitrogen additives

A series of experiments with simulated synthetic fuels were conducted in order to investigate the effect of droplet size on the conversion of fuel-nitrogen to NOx. Pyridine and pyrrole were added to n-heptane as nitrogen-containing additives and burned as monodisperse fuel droplets under various operating conditions in a spray combustion facility. The experimental results indicate that under stoichiometric and fuel-rich conditions, reducing the droplet size increases the efficiency of fuel-N conversion to NOx. This observation is associated with improved oxidation of the pyrolysis fragments of the additive by better oxygen penetration through the droplet flame zone. The dominant reactions by which fuel-N is transformed to NOx were also considered analytically by a premixed laminar flame code. The calculations are compared to the small droplet size results.

Sarv, Hamid↗

Fuel Pond Sludge - Lessons Learned from Initial De-sludging of Sellafield's Pile Fuel Storage Pond - 12066

The Pile Fuel Storage Pond (PFSP) at Sellafield was built and commissioned between the late 1940's and early 1950's as a storage and cooling facility for irradiated fuel and isotopes from the two Windscale Pile reactors. The pond was linked via submerged water ducts to each reactor, where fuel and isotopes were discharged into skips for transfer along the duct to the pond. In the pond the fuel was cooled then de-canned underwater prior to export for reprocessing. The plant operated successfully until it was taken out of operation in 1962 when the First Magnox Fuel Storage Pond took over fuel storage and de-canning operations on the site. The pond was then used for storage of miscellaneous Intermediate Level Waste (ILW) and fuel from the UK's Nuclear Programme for which no defined disposal route was available. By the mid 1970's the import of waste ceased and the plant, with its inventory, was placed into a passive care and maintenance regime. By the mid 1990s, driven by the age of the facility and concern over the potential challenge to dispose of the various wastes and fuels being stored, the plant operator initiated a programme of work to remediate the facility. This programme is split into a number of key phases targeted at sustained reduction in the hazard associated with the pond, these include: - Pond Preparation: Before any remediation work could start the condition of the pond had to be transformed from a passive store to a plant capable of complex retrieval operations. This work included plant and equipment upgrades, removal of redundant structures and the provision of a effluent treatment plant for removing particulate and dissolved activity from the pond water. - Canned Fuel Retrieval: Removal of canned fuel, including oxide and carbide fuels, is the highest priority within the programme. Handling and export equipment required to remove the canned fuel from the pond has been provided and treatment routes developed utilising existing site facilities to allow the fuel to be reprocessed or conditioned for long term storage. - Sludge Retrieval: In excess of 300 m{sup 3} of sludge has accumulated in the pond over many years and is made up of debris arising from fuel and metallic corrosion, wind blown debris and bio-organic materials. The Sludge Retrieval Project has provided the equipment necessary to retrieve the sludge, including skip washer and tipper machines for clearing sludge from the pond skips, equipment for clearing sludge from the pond floor and bays, along with an 'in pond' corral for interim storage of retrieved sludge. Two further projects are providing new plant processing routes, which will initially store and eventually passivate the sludge. - Metal Fuel Retrieval: Metal Fuel from early Windscale Pile operations and various other sources is stored within the pond; the fuel varies considerably in both form and condition. A retrieval project is planned which will provide fuel handling, conditioning, sentencing and export equipment required to remove the metal fuel from the pond for export to on site facilities for interim storage and disposal. - Solid Waste Retrieval: A final retrieval project will provide methods for handling, retrieval, packaging and export of the remaining solid Intermediate Level Waste within the pond. This includes residual metal fuel pieces, fuel cladding (Magnox, aluminium and zircaloy), isotope cartridges, reactor furniture, and miscellaneous activated and contaminated items. Each of the waste streams requires conditioning to allow it to be and disposed of via one of the site treatment plants. - Pond Dewatering and Dismantling: Delivery of the above projects will allow operations to progressively remove the radiological inventory, thereby reducing the hazard/risk posed by the plant. This will then allow subsequent dewatering of the pond and dismantling of the structure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cell module and fuel conditioner

Measurements of stack height changes with temperature and cell material characteristics were made. Stack 559 was assembled and components were fabricated for 560, 561, and 562. Stack 425 was transferred from the parallel DOE program and installed in the OS/IES simulation loop for mechanical and electrical testing. Construction and preliminary checkout of the 2 kW test facility was completed and design and procurement of the 8 kW test facility was initiated. The fuel conditioning subsystem design continued to evolve and the state points for the current design were calculated at full and part load conditions. Steam reforming catalyst activity tests were essentially completed and aging tests and CO shift converter tests were initiated.

Hoover, D. Q., Jr.↗

Testing Accident Tolerant Fuels in Reactivity Initiated Accident Conditions

The Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL) has been successfully restarted. A principal goal of restarting the reactor was to perform transient testing of Accident Tolerant Fuels (ATF), supporting their safe adoption by the commercial Light Water Reactor (LWR) fleet. This paper will describe the efforts underway at INL to conduct testing of ATF under Reactivity Initiated Accident (RIA) conditions in an inert helium atmosphere. Tests in an inert helium atmosphere capsule provide valuable information about initial deposition and distribution of energy in the nuclear fuel. Tests in an inert helium atmosphere are especially suited for ATF concepts where the thermophysical properties of the new fuel material differ from UO2 such as the U3Si2 fuel concept and other non-oxide materials. These tests are also useful for exploring the thermal mechanical interaction of pellets with cladding where the cladding mechanical properties do not change much with temperature such as Silicon Carbide Cladding. Tests with nominal dimensions will be used to determine how fresh fuel failure and core coolability limits of ATF pellet and cladding materials compare with that of standard LWR fuel made up of UO2 pellets and Zircaloy cladding. Tests with a reduced pellet cladding gap will be used as a preliminary indicator of any pellet cladding mechanical interaction (PCMI) vulnerabilities of the new fuel concepts. The materials, methods, and schedule for the ATF RIA tests will be discussed in the paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Polyethylene Upcycling to Liquid Alkanes in Molten Salts under Neat and External Hydrogen Source-Free Conditions

Development of facile approaches to convert plastic waste into liquid fuels under neat conditions is highly desired but challenging, particularly without noble metal catalysts and an external hydrogen source. Herein, highly efficient and selective polyethylene-to-gasoline oil (branched C 6 –C 12 alkanes) conversion was achieved under mild conditions (<170 °C) using commercially available AlCl 3 -containing molten salts as reaction media and to provide catalytic sites (no extra solvents, additives, or hydrogen feeding). The high catalytic efficiency and selectivity was ensured by the abundant active Al sites with strong Lewis acidity (comparable to the Al type in acidic zeolite) and highly ionic nature of the molten salts to stabilize the carbenium intermediates. Dynamic genesis of the Al sites was elucidated via time-resolved Al K-edge soft X-ray and 27 Al NMR, confirming the tricoordinated Al 3+ as active sites and its coordination with the as-generated alkene/aromatic intermediates. Further, the carbenium formation and polyethylene chain variation was illustrated by inelastic neutron scattering (INS) and an isotope-labeling experiment. Theoretical simulations further demonstrated the successive hydride abstraction, β-scission, isomerization, and internal hydrogen transfer reaction pathway with AlCl 3 as active sites. This facile catalytic system can further achieve the conversion of robust, densely assembled, and high molecular weight plastic model compounds to liquid alkane products in the diesel range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Empirically verified analysis of dual pre-cooling system for hydrogen refuelling station

The dual cooling system at the California State University Los Angeles Hydrogen Research and Fueling Facility is analysed to predict the output hydrogen temperature in different ambient conditions. Initially, the facility was built with a coil chiller T20 cooling, sufficient for occasional fuelings. A flat plate evaporator system was added in series to resolve any issues for multiple fuelings even in the hottest weather. This study was commenced to verify the set points and determine the control requirements for the dual setup in order to inform future designs. A numerical-empirical model of the cooling system was developed by reverse engineering, using the station experimental measurements and database records. The subsystems are characterized separately but validated as a whole system imposing specific and standard operating conditions. The cooling model is tested with different inputs to validate the pre-set parameter variation of the cooling components. Ten scenarios were investigated to evaluate the fueling output parameters, testing two hydrogen temperature input trends (according to the facility initial conditions) and five ambient temperatures (from 15 °C to 35 °C). In closing, the simulation results have confirmed that the hydrogen output temperature remains within the range imposed by the SAE J2601 for each scenario studied, around -22 °C and -25 °C.

08 HYDROGEN↗

Thermo-Hydro-Geochemical Evolution Influences on the Concrete Cask in Long-Term Storage Facility of Spent Fuel - 16171

Due to humid environment and weather condition in Taiwan's island, as well as the acid rain environment resulting from sulfur dioxide emissions, the concrete cask might be damaged or degraded under the effect of humid, salt, acid rain, and sulfate attack on cementitious materials. These degradation factors could influence the safety design of the long-term spent fuel storage facility. Due to the long-term decay heat of spent fuel and severe environments to be encountered, the thermo-hydro-geochemical evolution could play an important role in the safety assessment of concrete-cask storage facility. The effects of humid, salt, acid rain, and sulfate attack on the degradation of cementitious materials of concrete-cask facility in thermo-hydro-geochemical evolution under rain water quality conditions have been investigated. The results show that the main processes responsible for concrete degradation are species induced from hydrogen ion, sulfate and chloride. For most storage and disposal casks and conditions, the American Concrete Institute nuclear safety code requirements (ACI-349 Appendix A) specify a bulk-concrete shield temperature limit of 150 deg. F (65.5 deg. C). However, localized temperatures at the inner walls of the shielding casks could reach 200-300 deg. F (93-149 deg. C). Simulation of geochemical degradation reactions for 100 years of cask storage under two temperature scenarios was performed. The results indicate that the hydrogen ion, sulfate anion, and chloride do not result in the dissolution of portlandite, or formation of ettringite and Friedel's salt. Therefore, these results indicate the concrete cask may remain in a durable condition. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and numerical/experimental characterization of a lab-scale flat flame reactor allowing the analysis of pulverized solid fuel devolatilization and oxidation at high heating rates

This paper deals with the thorough characterization of a new experimental test bench designed to study the devolatilization and oxidation of pulverized fuel particles in a wide range of operating conditions. This lab-scale facility is composed of a fuel feeding system, the functioning of which has been optimized by computational fluid dynamics. It allows delivering a constant and time-independent mass flow rate of fuel particles which are pneumatically transported to the central injector of a hybrid McKenna burner using a carrier gas stream that can be inert or oxidant depending on the targeted application. A premixed propane/air laminar flat flame stabilized on the porous part of the burner is used to generate the hot gases insuring the heating of the central coal/carrier-gas jet with a thermal gradient similar to those found in industrial combustors (>10{sup 5} K/s). In the present work, results issued from numerical simulations performed a priori to characterize the velocity and temperature fields in the reaction chamber have been analyzed and confronted with experimental measurements carried out by coupling particle image velocimetry, thermocouple and two-color pyrometry measurements so as to validate the order of magnitude of the heating rate delivered by such a new test bench. Finally, the main features of the flat flame reactor we developed have been discussed with respect to those of another laboratory-scale system designed to study coal devolatilization at a high heating rate.

42 ENGINEERING↗

IGFC response to initial fuel cell load for various syngas compositions

The system response to an initial electric load of the fuel cell during the startup of a direct-fired fuel cell turbine power system was studied using the Hybrid Performance (Hyper) project hardware-based simulation facility at the U.S. Department of Energy, National Energy Technology Laboratory for a range of input fuel compositions. The facility was brought to a steady condition at a temperature deemed adequate to minimize stress on the fuel cell during the initial load transient. A 1D distributed fuel cell model operating in real-time was used to produce individual cell transient temperature profiles during the course of the load change. The process was conducted with humidified hydrogen, and then repeated with various syngas compositions representative of different gasifier technologies. The results provide insight into control strategy requirements for mitigation of expected fuel cell failure modes relevant to available gasifier technology.

30 DIRECT ENERGY CONVERSION↗

Developing a concept for a national used fuel interim storage facility in the United States

In the United States (U.S.) the nuclear waste issue has plagued the nuclear industry for decades. Originally, spent fuel was to be reprocessed but with the threat of nuclear proliferation, spent fuel reprocessing has been eliminated, at least for now. In 1983, the Nuclear Waste Policy Act of 1982 [1] was established, authorizing development of one or more spent fuel and high-level nuclear waste geological repositories and a consolidated national storage facility, called a 'Monitored Retrievable Storage' facility, that could store the spent nuclear fuel until it could be placed into the geological repository. Plans were under way to build a geological repository, Yucca Mountain, but with the decision by President Obama to terminate the development of Yucca Mountain, a consolidated national storage facility that can store spent fuel for an interim period until a new repository is established has become very important. Since reactor sites have not been able to wait for the government to come up with a storage or disposal location, spent fuel remains in wet or dry storage at each nuclear plant. The purpose of this paper is to present a concept developed to address the DOE's goals stated above. This concept was developed over the past few months by collaboration between the DOE and industry experts that have experience in designing spent nuclear fuel facilities. The paper examines the current spent fuel storage conditions at shutdown reactor sites, operating reactor sites, and the type of storage systems (transportable versus non-transportable, welded or bolted). The concept lays out the basis for a pilot storage facility to house spent fuel from shutdown reactor sites and then how the pilot facility can be enlarged to a larger full scale consolidated interim storage facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxy-fuel combustion of coal and biomass, the effect on radiative and convective heat transfer and burnout

This paper focuses on results of co-firing coal and biomass under oxy-fuel combustion conditions on the RWEn 0.5 MWt Combustion Test Facility (CTF). Results are presented of radiative and convective heat transfer and burnout measurements. Two coals were fired: a South African coal and a Russian Coal under air and oxy-fuel firing conditions. The two coals were also co-fired with Shea Meal at a co-firing mass fraction of 20%. Shea Meal was also co-fired at a mass fraction of 40% and sawdust at 20% with the Russian Coal. An IFRF Aerodynamically Air Staged Burner (AASB) was used. The thermal input was maintained at 0.5 MWt for all conditions studied. The test matrix comprised of varying the Recycle Ratio (RR) between 65% and 75% and furnace exit O{sub 2} was maintained at 3%. Carbon-in-ash samples for burnout determination were also taken. Results show that the highest peak radiative heat flux and highest flame luminosity corresponded to the lowest recycle ratio. The effect of co-firing of biomass resulted in lower radiative heat fluxes for corresponding recycle ratios. Furthermore, the highest levels of radiative heat flux corresponded to the lowest convective heat flux. Results are compared to air firing and the air equivalent radiative and convective heat fluxes are fuel type dependent. Reasons for these differences are discussed in the main text. Burnout improves with biomass co-firing under both air and oxy-fuel firing conditions and burnout is also seen to improve under oxy-fuel firing conditions compared to air. (author)

01 COAL, LIGNITE, AND PEAT↗

Simulation of Spent Nuclear Fuel loading into a Final Waste Repository

Previous work towards studying repository loading have used: - spent nuclear fuel (SNF) with an average burnup composition; - a lumped capacitance thermal model for calculating temperature in a Cyclus repository model. The goal of this work is to improve on the repository models and use U.S. historical SNF inventory data in simulations to more accurately study the loading of a waste repository. These goals will be achieved by: - using UNF-ST-and-DARDS Unified Database (UDB) that has historic assembly-specific data (e.g, isotopic composition, heat) in Cyclus simulations; - implementing a more accurate thermal model within a Cyclus repository model. Objectives: - Create a Cyclus spent fuel conditioning model that packages spent fuel bundles into packages which have user-defined properties. - Create a Cyclus medium-fidelity repository model that gives accurate time and spatial dependent temperature values and loads the repository based on a user-selected loading strategy. Cyclus is an agent-based extensible framework for modeling flow of material through user-defined nuclear fuel cycles. In Cyclus, each facility in the fuel cycle is modeled individually and the facilities interact with one another as independent agents. The spent fuel conditioning model accepts spent fuel bundles and puts them into a cylindrical waste package. In the spent fuel conditioning model, the user can define variables: For each layer, radius, thermal conductivity, thermal diffusivity; For each package, Number of spent fuel bundles, Radius and height. The waste repository model accepts waste packages and emplaces them into available positions within the waste repository based on a thermal criteria. The thermal criteria is a temperature limit at the interface between the waste package surface and the host geology, that is set based on the repository's host geology. In the waste repository model, the user can define the variables: Capacity, Distance between waste packages, Distance between drifts, Repository host geology, Loading Strategy. After the addition of new waste packages at each time step, the waste repository model recalculates the temperature at each location in the repository. If the addition of this new package causes its temperature to exceed the thermal limit, it will be placed back into the buffer. A thermal model that relies on a transient 'outside' model and quasi-steady-state 'inside' model is used to accurately determine the temperature in the repository. The 'outside' model assumes a homogenous medium with the Engineered Barrier System (EBS) replaced by the geologic medium. Temperature solutions for the central waste package, adjacent point and line sources are superimposed to calculate the temperature at specific points in the repository. The central drift consists of one finite line source which represents the central waste package. The central drift also consists of point sources that represent neighboring waste packages in the central drift. The neighboring drifts are represented by infinite line sources. The 'inside' model is considered to be at a quasi-steady-state condition because EBS has a relatively low thermal mass compared to the infinite geologic medium. The steady state calculation is performed at each time step with the heat source and interface temperature as boundary conditions. Future Work: Run Cyclus simulations with U.S. historical SNF inventory data, the spent fuel conditioning and repository models to study how waste package acceptance strategies impact repository loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optical Diagnosis of Gas Turbine Combustors Being Conducted

Researchers at the NASA Glenn Research Center, in collaboration with industry, are reducing gas turbine engine emissions by studying visually the air-fuel interactions and combustion processes in combustors. This is especially critical for next generation engines that, in order to be more fuel-efficient, operate at higher temperatures and pressures than the current fleet engines. Optically based experiments were conducted in support of the Ultra-Efficient Engine Technology program in Glenn's unique, world-class, advanced subsonic combustion rig (ASCR) facility. The ASCR can supply air and jet fuel at the flow rates, temperatures, and pressures that simulate the conditions expected in the combustors of high-performance, civilian aircraft engines. In addition, this facility is large enough to support true sectors ("pie" slices of a full annular combustor). Sectors enable one to test true shapes rather than rectangular approximations of the actual hardware. Therefore, there is no compromise to actual engine geometry. A schematic drawing of the sector test stand is shown. The test hardware is mounted just upstream of the instrumentation section. The test stand can accommodate hardware up to 0.76-m diameter by 1.2-m long; thus sectors or small full annular combustors can be examined in this facility. Planar (two-dimensional) imaging using laser-induced fluorescence and Mie scattering, chemiluminescence, and video imagery were obtained for a variety of engine cycle conditions. The hardware tested was a double annular sector (two adjacent fuel injectors aligned radially) representing approximately 15 of a full annular combustor. An example of the two-dimensional data obtained for this configuration is also shown. The fluorescence data show the location of fuel and hydroxyl radical (OH) along the centerline of the fuel injectors. The chemiluminescence data show C2 within the total observable volume. The top row of this figure shows images obtained at an engine low-power condition, and the bottom row shows data from a higher power operating point. The data show distinctly the differences in flame structure between low-power and high-power engine conditions, in both location and amount of species produced (OH, C2) or consumed (fuel). The unique capability of the facility coupled with its optical accessibility helps to eliminate the need for high-pressure performance extrapolations. Tests such as described here have been used successfully to assess the performance of fuel-injection concepts and to modify those designs, if needed.

Hicks, Yolanda R.↗

INITIAL ANALYSIS OF TRANSIENT POWER TIME LAG DUE TO HETEROGENEITY WITHIN THE TREAT FUEL MATRIX.

The topic Nuclear Safety encompasses a broad spectrum of focal areas within the nuclear industry; one specific aspect centers on the performance and integrity of nuclear fuel during a reactivity insertion accident (RIA). This specific accident has proven to be fundamentally difficult to theoretically characterize due to the numerous empirically driven characteristics that quantify the fuel and reactor performance. The Transient Reactor Test (TREAT) facility was designed and operated to better understand fuel behavior under extreme (i.e. accident) conditions; it was shutdown in 1994. Recently, efforts have been underway to commission the TREAT facility to continue testing of advanced accident tolerant fuels (i.e. recently developed fuel concepts). To aid in the restart effort, new simulation tools are being used to investigate the behavior of nuclear fuels during facility’s transient events. This study focuses specifically on the characterizing modeled effects of fuel particles within the fuel matrix of the TREAT. The objective of this study was to (1) identify the impact of modeled heterogeneity within the fuel matrix during a transient event, and (2) demonstrate acceptable modeling processes for the purpose of TREAT safety analyses, specific to fuel matrix and particle size. Hypothetically, a fuel that is dominantly heterogeneous will demonstrate a clearly different temporal heating response to that of a modeled homogeneous fuel. This time difference is a result of the uniqueness of the thermal diffusivity within the fuel particle and fuel matrix. Using MOOSE/BISON to simulate the temperature time-lag effect of fuel particle diameter during a transient event, a comparison of the average graphite moderator temperature surrounding a spherical particle of fuel was made for both types of fuel simulations. This comparison showed that at a given time and with a specific fuel particle diameter, the fuel particle (heterogeneous) simulation and the homogeneous simulation were related by a multiplier relative to the average moderator temperature. As time increases the multiplier is comparable to the factor found in a previous analytical study from literature. The implementation of this multiplier and the method of analysis may be employed to remove assumptions and increase fidelity for future research on the effect of fuel particles during transient events.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of the Idaho National Laboratory Hot Fuel Examination Facility Stack Monitoring Site for Compliance with ANSI/HPS N13.1 1999

This document reports on a series of tests to determine whether the location of the air sampling probe in the Hot Fuels Examination Facility (HFEF) heating, ventilation and air conditioning (HVAC) exhaust duct meets the applicable regulatory criteria regarding the placement of an air sampling probe. Federal regulations require that a sampling probe be located in the exhaust stack according to the criteria of the ANSI/HPS N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that is representative of the effluent stream. The tests conducted by PNNL during July 2010 on the HFEF system are described in this report. The sampling probe location is approximately 20 feet from the base of the stack. The stack base is in the second floor of the HFEF, and has a building ventilation stream (limited potential radioactive effluent) as well as a process stream (potential radioactive effluent, but HEPA-filtered) that feeds into it. The tests conducted on the duct indicate that the process stream is insufficiently mixed with the building ventilation stream. As a result, the air sampling probe location does not meet the criteria of the N13.1-1999 standard. The series of tests consists of various measurements taken over a grid of points in the duct cross section at the proposed sampling-probe location. The results of the test series on the HFEF exhaust duct as it relates to the criteria from ANSI/HPS N13.1-1999 are desribed in this report. Based on these tests, the location of the air sampling probe does not meet the requirements of the ANSI/HPS N13.1-1999 standard, and modifications must be made to either the HVAC system or the air sampling probe for compliance. The recommended approaches are discussed and vary from sampling probe modifications to modifying the junction of the two air exhaust streams.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗