Search NASA⌕ Search

SEARCH · Search NASA

Results for “Failure Diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Bend Properties of Sapphire Fibers at Elevated Temperatures: Bend Survivability - 1

The effect of temperature on the bend radius that a c-axis-oriented sapphire fiber can withstand was determined for fibers of various diameter. Bend stress rupture tests were performed for times of 1-100 h and temperatures of 300-1700 C. Fibers would survive the bend test undeformed, would fracture or would deform. The bend survival radius was determined to be the radius above which no fibers fractured or deformed for a given time-temperature treatment. It was found that the ability of fibers to withstand curvature decreases substantially with time and increasing temperature and that fibers of smaller diameter (46-83 micron) withstood smaller bend radii than would be expected from just a difference in fiber diameter when compared with the bend results of the fibers of large diameter (144 micron). This was probably due to different flaw populations, causing high temperature bend failure for the tested sapphire fibers of different diameters.

Morscher, Gregory N.↗

On 'large-scale' stable fiber displacement during interfacial failure in metal matrix composites

Experimental results are presented to show that interfacial failure in sapphire-reinforced niobium is characterized by 'large-scale' (5-15 microns) plasticity-controlled fiber displacements occurring under increasing loads. The results are based on the responses during thin-slice fiber pushout tests wherein the fiber is supported over a hole twice the fiber diameter. The results describe an interfacial failure process that should also occur near fiber ends during pullout when a fiber is well-bonded to a soft, ductile matrix, such that eventual failure occurs by shear within the matrix near the interface.

Petrich, R. R.↗

Effect of impact damage and holes on the compressive strength of a graphite/epoxy laminate

An experimental investigation has been conducted to determine the effect of low-velocity impact damage and unloaded circular holes on the compressive strength of a 48-ply orthotropic graphite/epoxy flat laminate. Specimens were impacted by a 1.27-cm-diameter aluminum sphere with speeds from 52 to 101 m/x to simulate momenta typical of low-velocity impact hazards that can occur in commercial aircraft service. It is shown that low-velocity impact damage can significantly degrade the static compressive strength of the laminate. Specimens that fail at axial strains above 0.008 in the undamaged condition can fail at strains as low as 0.0031 when impacted at 100 m/s. Circular holes also reduce the static compressive strength of the laminate. The failure strain decreases as the hole diameter increases.

Starnes, J. H., Jr.↗

Failure processes within ceramic coatings at high temperatures

Plasma sprayed coatings have a complex structure which is produced by the overlaying of many molten or semi-molten particles in the diameter range of 20 to 120 microns. The failure behavior of coatings has been characterized by using acoustic emission (AE) methodology. Coatings of NiCrAlY bond coat with a zirconia-12 wt pct yttria overlay were applied to disk-shaped specimens of U-700 alloy. A waveguide of 1-mm diameter platinum was TlG welded to the specimen and allowed it to be suspended in a tubular furnace. The specimen was thermally cycled to 1150 C and the AE monitored. Analyses have been carried out with the aim of establishing parameters which are related to the crack size population. These studies have been used to postulate types of cracking mechanisms which may occur in plasma sprayed coatings during thermal cycling. It is shown that microcracking gave rise to a large amount of AE. However, this coating still survived more thermal cycles than a coating which exhibited macrocracking events.

Berndt, Christopher↗

Failure analysis of a graphite/epoxy laminate subjected to bolt bearing loads

Quasi-isotropic graphite/epoxy laminates (T300/5208) were tested under bolt bearing loads to study failure modes, strengths, and failure energy. Specimens had a range of configurations to produce failures by the three nominal failure modes: tension, shearout, and bearing. Radiographs were made after damage onset and after ultimate load to examine the failure modes. Also, the laminate stresses near the bolt hole calculated for each test specimen configuration, and then used with a failure criterion to analyze the test data. Failures involving extensive bearing damage were found to dissipate significantly more energy than tension dominated failures. The specimen configuration influenced the failure modes and therefore also influenced the failure energy. In the width-to-diameter ratio range of 4 to 5, which is typical of structural joints, a transition from the tension mode to the bearing mode was shown to cause a large increase in failure energy. The failure modes associated with ultimate strength were usually different from those associated with the damage onset. Typical damage sequences involved bearing damage onset at the hole boundary followed by tension damage progressing from the hole boundary.

Crews, J. H., Jr.↗

Failure analysis of a graphite/epoxy laminate subjected to bolt-bearing loads

Quasi-isotropic graphite-epoxy laminates (T300/5208) were tested under bolt bearing loads to study failure modes, strengths, and failure energy. Specimens had a range of configurations to produce failures by the three nominal failure modes: tension, shearout, and bearing. Radiographs were made after damage onset and after ultimate load to examine the failure modes. Also, the laminate stresses near the bolt hole calculated for each test specimen configuration, and then used with a failure criterion to analyze the test data. Failures involving extensive bearing damage were found to dissipate significantly more energy than tension dominated failures. The specimen configuration influenced the failure modes and therefore also influenced the failure energy. In the width-to-diameter ratio range of 4 to 5, which is typical of structural joints, a transition from the tension mode to the bearing mode was shown to cause a large increase in failure energy. The failure modes associated with ultimate strength were usually different from those associated with the damage onset. Typical damage sequences involved bearing damage onset at the hole boundary followed by tension damage progressing from the hole boundary.

Crews, J. H., Jr.↗

High Resolution Computed Tomography Inspection of Components Uncovers Root Causes of Vexing Failure Mysteries

During testing of actuators for fight programs, failures have occurred that required closure with an understanding of the root cause of the failure. For some InSight project actuators, intermittent changes of the winding resistance of the motors during temperature changes was extremely baffling. It was critical to determine the cause of the intermittent characteristic because the actuators were stock from a previous program and the company that provided the motors was no longer in business. Using an X-Ray Computed-Tomography (CT) method, the exact source of the intermittent failure was determined and completely understood – at dimensions of less than 20 microns. In another case, after the completion of an actuator’s life-test-to-failure, inspection was required to determine the source of the failure. The size of the actuator (10 mm diameter) required destructive means to get to the interior of the actuator for inspection, risking the loss of the source of the failure. Using CT imaging, the exact source of the failure was determined.

Johnson, Michael R.↗

Ultimate strength of high-load-capacity composite bolted joints

Presented are the results of a series of tests initiated to obtain baseline data on the load-carrying capacity of bolted joints designed to carry large loads, specifically up to 222 kN (50 kips). The major testing purposes were to determine the load carrying capacity as a function of the width and thickness of the joint and the diameter and number of bolts, and to observe the failure mode. A total of 100 tests were conducted on three different specimen configurations. The specimens were fabricated from a T300/5208 fiber/resin system in a quasi-isotropic lay-up. The results presented indicate that for a given ratio of specimen width to hole diameter, the specimens with the smaller holes sustained a higher net-section tensile stress before failure. In addition, for a given ratio of specimen width to hole diameter, the thinner specimens withstood a higher net-section stress. No attempt has been made to correlate the results with theoretical predictions.

Hyer, M. W.↗

New morphometric data for fresh lunar craters

Morphometric relations have been determined for 2598 fresh craters on the lunar nearside using data given in the catalog of Wood and Andersson (1978). For each of five principal morphological types, typified by Albategnius C, Biot, Sosigenes, Triesnecker, and Tycho, statistical relations are documented for the following: crater diameter and depth; floor diameter and crater diameter; central peak height and crater diameter; average wall slope and crater depth; central peak occurrence and crater diameter; occurrence of scallops or terraces and crater diameter. The first four relations generally confirm the conclusions of Pike (1977), but the last two differ from results reported by Smith and Sanchez (1973). Small (diameter less than 20 km) flat-floored craters formed in mare terrains are as much as 10% deeper than those formed in the highlands, and the depths of small bowl-shaped craters reflect even greater dependence on terrain. Larger, scalloped-walled craters are deeper in highland terrain than on the maria. Although wall failure does not occur until the crater diameter reaches 13 km, central peaks are found in flat floor craters as small as 2 km.

Wood, C. A.↗

LX-17 and ufTATB Data for Corner-Turning, Failure and Detonation

Data is presented for the size (diameter) effect for ambient and cold confined LX-17, unconfined ambient LX-17, and confined ambient ultrafine TATB. Ambient, cold and hot double cylinder corner-turning data for LX-17, PBX 9502 and ufTATB is presented. Transverse air gap crossing in ambient LX-17 is studied with time delays given for detonations that cross.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fracture analysis of surface and through-cracks in cylindrical pressure vessels

A previously developed fracture criterion was applied to surface- and through-cracked cylindrical pressure vessels to see how well the criterion can correlate fracture data. Fracture data from the literature on surface cracks in aluminum alloy, steel, and epoxy vessels and on through cracks in aluminum alloy, titanium alloy, steel, and brass vessels were analyzed using the fracture criterion. The criterion correlated the failure stresses to within + or - 10 percent for either surface or through cracks over a wide range of crack size and vessel diameter. The fracture criterion was also found to correlate failure stresses from flat plates (center-crack or double-edge-crack tension specimens) and cylindrical pressure vessels containing through - cracks within + or - 10 percent.

Newman, J. C., Jr.↗

Fracture analysis of surface and through cracks in cylindrical pressure vessels

A previously developed fracture criterion was applied to fracture data for surface- and through-cracked cylindrical pressure vessels to see how well the criterion can correlate fracture data. Fracture data from the literature on surface cracks in aluminum alloy, steel, and epoxy vessels, and on through cracks in aluminum alloy, titanium alloy steel, and brass vessels were analyzed by using the fracture criterion. The criterion correlated the failure stresses to within + or - 10 percent for either surface or through cracks over a wide range of crack size and vessel diameter. The fracture criterion was also found to correlate failure stresses to within + or - 10 percent for flat plates (center-crack or double-edge-crack tension specimens) and cylindrical pressure vessels containing through cracks.

Newman, J. C., Jr.↗

Test-to-Failure of a Two-Grid, 30-cm-dia. Ion Accelerator System

To determine the failure mechanism and erosion characteristics of an ion accelerator system due to erosion by charge-exchange ions a test was performed in which a 30-cm-diameter, 2-grid ion accelerator system was tested to failure. The erosion charcteristics observed in this test, however, imply significantly shorter accelerator grid life times than typically stated in the literature. Finally, the test suggests that structural failure is probably not the most likely first failure mechanism for the accelerator grid.

distortion↗

Beam and Torsion Tests of Aluminum-alloy 61S-T Tubing

Tests were made to determine the effect of length and the effect of ratios of diameter to wall thickness upon the flexural and torsional moduli of failure of 61S-T aluminum-alloy tubing. The moduli of failure in bending, as determined by tests in which the tubing was loaded on the neutral axis at the one-third points of the span, were found to bear an approximately linear relationship with diameter-thickness ratio and were practically independent of span within the limits investigated. Empirical equations are given describing the relations obtained. The moduli of failure in torsion were found to be dependent upon length as well as upon diameter-thickness ratios. Empirical equations are given for predicting strengths within the range of plastic buckling. Within the elastic range, available torsion theories were found to be satisfactory.

Moore, R L↗

Validation of material models for puncture of 7075-T651 aluminum plate

Plate puncture simulations are challenging computational tasks that require advanced material models including high strain rate and thermal-mechanical effects on both deformation and failure, plus finite element techniques capable of representing large deformations and material failure. The focus of this work is on the material issues, which require large sets of experiments, flexible material models and challenging calibration procedures. In this study, we consider the puncture of 12.7 mm thick, 7075-T651 aluminum alloy plates by a cylindrical punch with a hemispherical nose and diameter of 12.7 mm. The plasticity and ductile failure models were isotropic with calibration data obtained from uniaxial tension tests at different temperatures and strain rates plus quasi-static notched tension tests and shear-dominated tests described here. Sixteen puncture experiments were conducted to identify the threshold penetration energy, mode of puncture and punch acceleration during impact, The punch was mounted on a 139 kg mass and dropped on the plates with different impact speeds. Since the mass was the same in all tests, the quantity of interest was the impact speed. The axis and velocity of the punch were perpendicular to the plate surface. The mean threshold punch speed was 3.05 m/s, and the mode of failure was plugging by thermal-mechanical shear banding accompanied by scabbing fragments. Application of the material models in simulations of the tests yielded accurate estimates of the threshold puncture speed and of the mode of failure. Time histories of the punch acceleration compared well between simulation and test. Remarkably, the success of the simulations occurred in spite of even the smallest element used being larger than the width of the shear bands.

36 MATERIALS SCIENCE↗

Failed Retrieval of an Inferior Vena Cava Filter During Pregnancy Because of Filter Tilt: Report of Two Cases

Thromboembolic disease during pregnancy is an important cause of obstetric morbidity and mortality. Pregnant patients with venous thromboembolism are usually managed by conventional anticoagulation. However, this must be discontinued during vaginal or caesarian delivery to avoid haemorrhage and to reduce the risk of possible epidural haematoma. Retrievable inferior vena cava filters (IVCFs) offer protection against pulmonary embolism during this high-risk period, when anticoagulation is discontinued, while avoiding potential long-term sequelae of a permanent IVCF. Here we report two patients who presented in the third trimester of pregnancy with floating ileofemoral deep vein thrombosis. Both patients were initially treated with standard anticoagulation; however, shortly before delivery both patients had a retrievable IVCF placed in a suprarenal position. In both patients, retrieval failed at 28 days after insertion because of filter tilt. The timing and mechanism of filter tilt remains uncertain. We believe that a number of factors could have been involved, including change in the anatomic configuration with lateral displacement of the IVCF as a result of the gravid uterus as well as forceful uterine contractions during labour, which modified the shape and diameter of the IVC. We showed that failure to retrieve the IVCF has had considerable implications for the two young patients regarding long-term anticoagulation and have highlighted the need for further clinical trials regarding the safe use of retrievable IVCFs during pregnancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Instrumentation for the Investigation of Pitch Bearing Design and Reliability

Recently, there has been an increasing level of industry interest in pitch system and pitch bearing reliability. Pitch bearings are used in wind turbines to connect the blade root to the hub. Some populations of pitch bearings have demonstrated a 12% failure rate in 20 years. As rotor diameters continue to increase for tall land-based and offshore wind turbines, pitch bearings are becoming even larger in diameter, which can make them vulnerable to deflections and consequent stress concentrations. There is an increased need to more accurately study pitch bearing deformations, misalignment, load distributions, and contact stresses. A significant body of work has investigated fatigue lives and wear characteristics of pitch bearings on ground-based test rigs. NREL has also recently begun a research program related to pitch bearing reliability, recognizing its growing importance for wind turbines. The purpose of this paper is to describe a set of instrumentation that was recently installed on a 1.5 MW wind turbine at the NREL Flatirons Campus and provide an example data set. To the authors' knowledge, this will be the first publicly available pitch bearing data collection campaign on an operational wind turbine.

17 WIND ENERGY↗