Search NASA⌕ Search

SEARCH · Search NASA

Results for “Faraday cups”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

47 records · Page 3

Longitudinal Emittance Measurements at PIP2IT

The PIP-II particle accelerator is a new upgrade to the Fermilab accelerator complex, featuring an 800-MeV H⁻ superconducting linear accelerator that will inject the beam into the present Fermilab Booster. A test accelerator known as PIP-II Injector Test (PIP2IT) has been built to validate the concept of the front-end of PIP-II. One of the paramount challenges of PIP2IT was to demonstrate a low longitudinal emittance at the end of the front end. Having a low longitudinal emittance is crucial in order to ensure the stability of the beam in the accelerator. We present a longitudinal emittance calculation at 14.3 MeV at the SSR1-8 cavity in the High Energy Transport line (HEBT). The signal is collected by a Fast Faraday Cup (FFC) at the end of HEBT and recorded by a high-bandwidth oscilloscope.

43 PARTICLE ACCELERATORS↗

Composition and Dynamical Processes of Ions in Giant Magnetospheres: The Importance of In Situ Measurements for Advancing the Current Knowledge [Slides]

In this white paper, we emphasize the importance of in situ ion composition measurements provided by plasma mass spectrometers in planetary magnetospheres (Uranus and Neptune) aimed for future planetary missions. We present our current understanding on magnetospheres of Uranus and Neptune that are largely based on Plasma Science Investigation (PLS, faraday cups) and Low Energy Charged Particle (LECP) instrument on Voyager 2 and what measurements need to be made to improve it. We emphasize that the future missions equipped with plasma mass spectrometers must visit these magnetospheres again to advance our current knowledge. Finally, this white paper summarizes key science questions that needs to be addressed which all of them requires a direct ion composition measurements from a plasma spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commissioning of Phase 1 of the LANL RFQ Test Stand - Beam Characterization

A series of numerical start-to-end simulations of Phase 1 of the 750 keV RFQ Test Stand which includes the ion source (H+ duoplasmatron), a 1-Solenoid LEBT, an emittance scan station and a Faraday cup were performed to find a mechanism for the characterization of the proton beam extracted from the duoplasmatron.

43 PARTICLE ACCELERATORS↗

ATONA Update [Slides]

The new ATONA amplifier, a Faraday Cup High Gain Resistor Amplifier, is described.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES↗

Power Density Distributions in Electron Beams

Measuring and controlling the power density distribution of electron beams used for welding is critical for producing repeatable welds and for transferring welding parameters between different machines. On any given machine, the power density distribution is controlled by defocusing the beam relative to its sharpest focused condition. However, measuring the power density distribution can be difficult due to the intense nature of welding beams and is further complicated by imperfect electron optics that can distort the beam, making it difficult to quantify. The enhanced modified Faraday cup (EMFC) diagnostic method was used here for beam analysis that utilizes computed tomography to reconstruct the beam’s power density distribution. These results were compared to the International Standards Organization (ISO) method for characterizing laser beams using a second-moment D4σ calculation. For ideal Gaussian-shaped beams, both methods would give the same result. However, for imperfect beams, the calculated D4σ diameter was shown to be about 25% larger relative to the FWe2 diameter measured by the EMFC due to the heavier weighting of data in the tails of the beam by D4σ. Finally, although both methods produce repeatable welds, it is important to understand the differences in the reported beam diameters, divergence angles, and beam parameter products when transferring parameters between machines.

36 MATERIALS SCIENCE↗

The Long Neglected Cycloidal Mass Analyzer

Cycloid mass spectrometers offer powerful advantages for isotope ratio measurements, including double focusing (mass and energy), linear mass dispersion over a large spatial area, and a small footprint. However, the linear cycloid has not been adopted as widely as other mass analyzer designs, in part because of challenges with utilizing common ion detectors such as electron multipliers and Faraday cups. Integration of a linear cycloid with a capacitive transimpedance amplifier detector arrays can overcome these challenges, resulting in a compact powerful mass spectrometer for precision isotope ratio measurements.

47 OTHER INSTRUMENTATION↗

Evaluation method of beam instability in laser ion source using solenoid

In a laser ion source using solenoid field confinement, it is known that an ion beam becomes unstable in the certain range of a magnetic field. Although it is essential to quantify the instability when discussing the unstable region of the beam, it is difficult to evaluate the beam instability by peak current or the amount of charge because an irregular change of temporal profile occurs in addition to the shot-by-shot fluctuation of amplitude. In this study, I propose the most appropriate method to evaluate the beam instability using the difference from an average waveform. The validity of the new method was evaluated by comparing three evaluation methods (variation of maximum value, variation of integral of waveforms, and the proposed evaluation method) with the experimentally obtained waveforms with the stable and unstable regions of a solenoid field. The proposed method was verified to best represent the beam instability by laser-induced plasma.

43 PARTICLE ACCELERATORS↗

Experimental demonstration of externally driven millimeter-wave particle accelerator structure

We report the experimental demonstration of a mm-wave electron accelerating structure powered by a high-power rf source. We demonstrate reliable coupling of an unprecedented rf power—up to 575kW into the mm-wave accelerator structure using a quasi-optical setup. This standing wave accelerating structure consists of a single-cell copper cavity and a Gaussian to TM 01 mode converter. The accelerator structure is powered by 110 GHz, 10-ns long rf pulses. These pulses are chopped from 3 microsecond pulses from a gyrotron oscillator using a laser-driven silicon switch. We show an unprecedented high gradient up to 230MV/m that corresponds to a peak surface electric field of more than 520 MV/m. We have achieved these results after conditioning the cavity with more than 100,000 pulses. We also report preliminary measurements of rf breakdown rates, which are important for understanding rf breakdown physics in the millimeter-wave regime. Furthermore, these results open up many frontiers for applications not only limited to the next generation particle accelerators but also x-ray generation, probing material dynamics, and nonlinear light-matter interactions at mm-wave frequency.

43 PARTICLE ACCELERATORS↗

Operation of Cs–Sb–O activated GaAs in a high voltage DC electron gun at high average current

Negative Electron Affinity (NEA) activated GaAs photocathodes are the most popular option for generating a high current (>1 mA) spin-polarized electron beam. Despite its popularity, a short operational lifetime is the main drawback of this material. Recent works have shown that the lifetime can be improved by using a robust Cs–Sb–O NEA layer with minimal adverse effects. In this work, we operate GaAs photocathodes with this new activation method in a high voltage environment to extract a high current. We demonstrate that improved chemical resistance of Cs–Sb–O activated GaAs photocathodes allowed them to survive a day-long transport process from a separate vacuum system using a vacuum suitcase. During beam running, we observed spectral dependence on lifetime improvement. In particular, we saw a 45% increase in the lifetime at 780 nm on average for Cs–Sb–O activated GaAs compared to Cs–O activated GaAs.

47 OTHER INSTRUMENTATION↗

Electron beam characterization via quantum coherent optical magnetometry

We present a quantum optics-based detection method for determining the position and current of an electron beam. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturbs the atomic spin's quantum state and causes polarization rotation of a laser resonant with an optical transition of the atoms. By measuring the polarization rotation angle across the laser beam, we recreate a 2D projection of the magnetic field and use it to determine the e-beam position, size, and total current. We tested this method for an e-beam with currents ranging from 30 to 110 μA. Our approach is insensitive to electron kinetic energy, and we confirmed that experimentally between 10 and 20 keV. In conclusion, this technique offers a unique platform for noninvasive characterization of charged particle beams used in accelerators for particle and nuclear physics research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗