Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault Termination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

51 records · Page 3

Trans-crustal structural control of CO 2 -rich extensional magmatic systems revealed at Mount Erebus Antarctica

Erebus volcano, Antarctica, with its persistent phonolite lava lake, is a classic example of an evolved, CO 2 -rich rift volcano. Seismic studies provide limited images of the magmatic system. Here we show using magnetotelluric data that a steep, melt-related conduit of low electrical resistivity originating in the upper mantle undergoes pronounced lateral re-orientation in the deep crust before reaching shallower magmatic storage and the summit lava lake. The lateral turn represents a structural fault-valve controlling episodic flow of magma and CO 2 vapour, which replenish and heat the high level phonolite differentiation zone. This magmatic valve lies within an inferred, east-west structural trend forming part of an accommodation zone across the southern termination of the Terror Rift, providing a dilatant magma pathway. Unlike H 2 O-rich subduction arc volcanoes, CO 2 -dominated Erebus geophysically shows continuous magmatic structure to shallow crustal depths of < 1 km, as the melt does not experience decompression-related volatile supersaturation and viscous stalling.

58 GEOSCIENCES↗

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY↗

Assessment of the Electrical Substation-Grid Testbed with Inside/Outside Devices and Distributed Ledger Technology

The electrical substation-grid testbed was created to integrate the GOOSE and/or DNP (Distributed Network Protocol) messages with time synchronized sources and Distributed Ledger Technology (DLT). The objective was to study the impact of faults and cyber-events at an electrical substation with inside (protective relays) and outside (power meters) substation devices. The electrical substation-grid testbed was based on the design of a 34.5/ 12.47 kV electrical substation (sectionalized bus configuration) with two power transformers, connected to radial power lines and load feeders. The electrical substation-grid testbed was installed at 252 lab space (Advanced Power System Protection), Grid Research Integration and Deployment Center (GRID-C), Oak Ridge National Laboratory. This testbed was created for Task 5, DarkNet project. The electrical substation-grid testbed was created to simulate fault and/or cyber events that could potentially result in damage to the electrical infrastructure. In addition, tests were run that are usually not allowed to be performed in an operational electrical power grid, because these test scenarios could trip breakers and/or generate fault situations that could potentially damage equipment. The number of tests performed in the electrical substation-grid testbed were executed in a better way than in a real electrical substation and/or power grid, because multiple tests could be run in a short period of time, and complex permits, and safety/ schedule restrictions like in a real electrical substation environment were not needed. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that are used by electrical utilities, to have same conditions that we could observe in a real power grid or electrical substation. The electrical substation-grid testbed was based on using a real time simulator and expansion box with amplifiers that were wired to electrical substation-grid devices. This hardware-in-the-loop (HIL) was provided by protective relays, power meters, ethernet switches, remote terminal units, synchronized timing network clock, DLT devices, workstations, and servers. This report includes the design, installation, and assessment of the electrical substation-grid testbed that was similar to an operational electrical substation, integrating the power system protection, communication, and control systems. The results for the electrical substation-grid testbed were based on:• verifying the analog signals for protective relays and power meters, • observing the synchronized time source frame at devices, • authenticating the GOOSE (IEC 61850) and DNP messages from power meters and protective relays, and • verifying the trip conditions of protective relays at fault tests with the power system fault event detection, using DLT devices. For future work, the electrical substation-grid testbed with protective relays and power meters, using DLT and synchronized time source from DarkNet, will be used to study the impact of cyber-events at inside and outside substation devices. Advanced algorithms for detecting cyber-events produced by non-desired protective relay settings will be studied, to improve the detection and reliability of protection, control, and communication systems at power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mixed Monopole and Bipole MTdc Architecture

Multi-terminal dc systems (MTdc) are becoming popular at transmission level voltages. High-voltage dc (HVdc) based on voltage-source-converter (VSC) technology is employed in such systems. In this paper, a new MTdc architecture, which is suitable for future expansion and easy operation under overhaul and maintenance of the converter stations is proposed. Steady state and dc fault simulation studies are performed to prove the feasibility of the MTdc architecture. Technical advantages and challenges related to the new architecture are detailed.

Jaldanki, Sreenivasa↗

Continental rift evolution and drainage reorganization along the Dead Sea rift since the Miocene

The Dead Sea fault is a section of the Arabian-African plate boundary. Widespread field relations indicate that three major drainage systems (stages) occupied the landscape west of the Dead Sea fault since its initiation at ca. 20 Ma. Specifically, (1) an early to middle Miocene drainage system, only minorly reconfigured by the fault (all sediments of this system belong to the Hazeva Formation); (2) a late Miocene to early Pleistocene fault-parallel drainage system named Paran-Neqarot (all sediments of this system belong to the Arava and Zehiha Formations; and (3) the early Pleistocene to present drainage configuration. The temporal and spatial frameworks of drainage stage 1 are generally constrained by radiometric dating of interfingering volcanic units, and the onset and temporal and spatial frameworks of drainage stage 3 are well constrained by cosmogenic 10 Be surface exposure ages. The timing and longevity of the rift-parallel drainage (stage 2) have until now been evasive to direct dating. The overall time gap between stages 1 and 3 is ~12–13 million years. Thus, an early age (within this time gap) of stage 2 would imply an immediate response of drainage reorganization to rift tectonics, while a later age of this drainage system would imply a delayed response. We present 11 10 Be- 26 Al cosmogenic burial ages of alluvial and colluvial units related to the fault-parallel drainage system (stage 2), which collectively constrain the time of deposition of the Arava Formation sediments in the central Negev to ca. 8 Ma. The general lack of stratigraphic order, together with the large dispersion of ages both across and within the sampling sites, attests to significant recycling of sediments from drainage stage 1 into the Arava Formation deposits. The termination of Arava and Zehiha Formation sediment deposition at ca. 1.8 Ma was determined previously using cosmogenic exposure ages of desert pavements that cover the formations. Combining the previously published data with our new data, we established the longevity and character of the Paran-Neqarot drainage system. In conlcusion, this framework highlights the temporal aspect of drainage system build-up and collapse as it responded to transform and extensional plate boundary tectonics during the Neogene.

58 GEOSCIENCES↗

Photovoltaic Inverter Momentary Cessation: Recovery Process is Key

Momentary cessation refers to an inverter control mode. When the inverter terminal voltage falls below (or exceeds) a certain level, the inverter ceases to output any current, but attempts to maintain (or quickly regain) phase-locked loop synchronization to allow for quick reinjection of current when the voltage recovers to a certain point. This paper presents a photovoltaic (PV) momentary cessation model developed in PSS/E. Simulations are presented for a high voltage transmission line fault contingency in the Hawaiian island of Oahu power system on a validated PSS/E model, modified to include a custom distributed PV inverter model, and different near-future distributed PV penetration levels. Simulations for the island power system include different penetration levels of PV, and different recovery times (ramp rates and delays) after momentary cessation. The results indicate that during low voltage events, such as faults, momentary cessation can produce severe under frequency events, causing significant load shed and shortly thereafter, in some cases, over frequency events that cause generation to trip offline. The problem is exacerbated with higher penetration levels of PV. If momentary cessation is used (as is typically the case for distribution-connected resources), the recovery process after momentary cessation should be carefully considered to minimize impacts to bulk power system stability.

14 SOLAR ENERGY↗

Bus repeater and bit injector for MIL-STD-1553/1760 communications bus

A fault insertion device (FID) comprises a transceiver and an FPGA. The transceiver receives signals from a MIL-STD-1553/1760 communications bus. The FPGA evaluates the signals received from the communications bus against a set of rules stored by the FPGA. Based upon the set of rules, the FPGA can selectively modify messages received from the communications bus prior to transmission to a remote terminal or a bus controller that is configured to communicate on the communications bus.

Krein, Jason P.↗

Cross-Cap Defects and Fault-Tolerant Logical Gates in the Surface Code and the Honeycomb Floquet Code

We consider the Z 2 toric code, surface code, and Floquet code defined on a nonorientable surface, which can be considered as families of codes extending Shor’s nine-qubit code. We investigate the fault-tolerant logical gates of the Z 2 toric code in this setup, which corresponds to e ↔ m exchanging symmetry of the underlying Z 2 gauge theory. We find that nonorientable geometry provides a new way for the emergent symmetry to act on the code space, and discover the new realization of the fault-tolerant Hadamard gate of the two-dimensional surface code with a single cross cap connecting the vertices nonlocally along a slit, dubbed a nonorientable surface code. This Hadamard gate can be realized by a constant-depth local unitary circuit modulo nonlocality caused by a cross cap. Via folding, the nonorientable surface code can be turned into a bilayer local quantum code, where the folded cross cap is equivalent to a bilayer twist terminated on a gapped boundary and the logical Hadamard only contains local gates with intralayer couplings when being away from the cross cap, as opposed to the interlayer couplings on each site needed in the case of the folded surface code. We further obtain the complete logical Clifford gate set for a stack of nonorientable surface codes and similarly for codes defined on Klein-bottle geometries. We then construct the honeycomb Floquet code in the presence of a single cross cap, and find that the period of the sequential Pauli measurements acts as a H Z logical gate on the single logical qubit, where the cross cap enriches the dynamics compared with the orientable case. We find that the dynamics of the honeycomb Floquet code is precisely described by a condensation operator of the Z 2 gauge theory, and illustrate the exotic dynamics of our code in terms of a condensation operator supported at a nonorientable surface. Published by the American Physical Society 2024

Physics↗

A Hybrid-Learning Algorithm for Online Dynamic State Estimation in Multimachine Power Systems

With the increasing penetration of distributed generators in the smart grids, having knowledge of rapid real-time electromechanical dynamic states has become crucial to system stability control. Conventional Supervisory Control and Data Acquisition (SCADA)-based dynamic state estimation (DSE) techniques are limited by the slow sampling rates, while the emerging phasor measurement units (PMUs) technology enables rapid real-time measurements at network nodes. Using generator bus terminal voltages, we propose a hybrid-learning DSE (HL-DSE) algorithm to estimate the synchronous machine rotor angle and speed in real time. The HL-DSE takes the power system model into account and trains neuroestimators with real-time data in an online manner. Compared with traditional DSE methods, the HL-DSE overcomes limitations by using a data-driven approach in conjunction with the physical power system model. The time efficiency, accuracy, convergence, and robustness of the proposed algorithm are tested under noises and fault conditions in both small- and large-scale test systems. Simulation results show that the proposed HL-DSE is much more computationally efficient than widely used Kalman filter (KF)-based methods while maintaining comparable accuracy and robustness. In particular, HL-DSE is over 100 times faster than square-root unscented KF (SR-UKF) and 80 times faster than extended KF (EKF). The advantages and challenges of the HL-DSE are also discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cretaceous sequence stratigraphy of the northern Baltimore Canyon Trough: Implications for basin evolution and carbon storage

We evaluate the Cretaceous stratigraphy and carbon sequestration potential of the northern Baltimore Canyon Trough (NBCT) using >10,000 km of multi-channel seismic profiles integrated with geophysical logs, biostratigraphy, and lithology from 29 offshore wells. We identify and map six sequences resolved primarily at the stage level. Accommodation was dominated by thermal and non-thermal subsidence, though sequence boundaries correlate with regional and global sea-level changes, and the record is modified by igneous intrusion, active faulting, and changes in sediment supply and sources. Our stratigraphic maps illustrate a primary southern (central Appalachian) Early Cretaceous source that migrated northward during the Aptian and Albian. During the Cenomanian, sedimentation rates in the NBCT increased and depocenters shifted northward and landward. We show that deposition occurred in three phases: (1) earlier Cretaceous paleoenvironments were primarily terrestrial indicated by variable amplitude, chaotic seismic facies, serrated gamma logs, and heterolithic sandstones and mudstones with terrestrial microfossils; (2) the Albian to Cenomanian was dominated by deltaic paleoenvironments indicated by blocky, funnel-shaped, gamma-ray logs and clinoforms characterized by continuous high-amplitude seismic reflections with well-defined terminations; and (3) the Cenomanian and younger was marine shelf, inferred from mudstoneprone lithologies, peak gamma-ray values in well logs, and foraminiferal evidence. Long-term transgression and maximum water depths at the Cenomanian/Turonian boundary correlative with Ocean Anoxic Event 2 were followed by a regression and relative sea-level fall. We show that porous and permeable sandstones of three Aptian to Cenomanian highstand systems tracts are high-volume reservoirs for supercritical CO 2 storage that are confined by overlying deep water mudstones.

58 GEOSCIENCES↗

Generalized Cycle Benchmarking Algorithm for Characterizing Midcircuit Measurements

Midcircuit measurements (MCMs) are crucial ingredients in the development of fault-tolerant quantum computation. While there have been rapid experimental progresses in realizing MCMs, a systematic method for characterizing noisy MCMs is still under exploration. In this work, we develop a cycle benchmarking (CB)-type algorithm to characterize noisy MCMs. The key idea is to use a joint Fourier transform on the classical and quantum registers and then estimate parameters in the Fourier space, analogous to Pauli fidelities used in CB-type algorithms for characterizing the Pauli-noise channel of Clifford gates. Furthermore, we develop a theory of the noise learnability of MCMs, which determines what information can be learned about the noise model (in the presence of state preparation and terminating measurement noise) and what cannot, which shows that all learnable information can be learned using our algorithm. As an application, we show how to use the learned information to test the independence between measurement noise and state-preparation noise in an MCM. Finally, we conduct numerical simulations to illustrate the practical applicability of the algorithm. Similar to other CB-type algorithms, we expect the algorithm to provide a useful toolkit that is of experimental interest. Published by the American Physical Society 2025

Zhang, Zhihan (ORCID:0009000862907691)↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, ate- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

14 SOLAR ENERGY↗

A Generic and Multi-Functional Electromagnetic Transient Model for Grid-Following Inverter: Preprint

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

grid following inverter↗