Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault mechanics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Earthquake source mechanisms and transform fault tectonics in the Gulf of California

The source parameters of 19 earthquakes in the Gulf of California were determined from an inversion of long-period P and SH waveforms. The inversion procedure is described and the estimated precision of the derived source parameters is examined, with particular attention given to source complexity, the resolution of slip vector azimuth, and the resolution of centroid depth. The implications of these earthquake source characteristics for the tectonic evolution of the gulf are discussed.

Goff, John A.↗

Two-Fault-Tolerant Release Mechanism

Remotely-operated, compact quick-release mechanism still functions in event that one or even two attempts to actuate it fail. Contains three independent pyrotechnic devices. Firing of any one of devices sufficient to actuate mechanism. Three pins hold toggle at its base. Retraction of any one of pins allows toggle head to rotate in spherical bearing to free itself from remaining pin or pins. Besides allowing rotation after retraction, bearing also aligns toggle during assembly.

Graves, Thomas J.↗

Mechanical model of an earthquake fault

The dynamic behavior of a simple mechanical model of an earthquake fault is studied. This model, introduced originally by Burridge and Knopoff (1967), consists of an elastically coupled chain of masses in contact with a moving rough surface. The present version of the model retains the full Newtonian dynamics with inertial effects and contains no externally imposed stochasticity or spatial inhomogeneity. The only nonlinear feature is a velocity-weakening stick-slip friction force between the masses and the moving surface. This system is being driven persistently toward a slipping instability and therefore exhibits noisy sequences of earthquakelike events. These events are observed in numerical simulations, and many of their features can be predicted analytically.

Carlson, J. M.↗

Random Forest Regressor-Based Approach for Detecting Fault Location and Duration in Power Systems

Power system failures or outages due to short-circuits or “faults” can result in long service interruptions leading to significant socio-economic consequences. It is critical for electrical utilities to quickly ascertain fault characteristics, including location, type, and duration, to reduce the service time of an outage. Existing fault detection mechanisms (relays and digital fault recorders) are slow to communicate the fault characteristics upstream to the substations and control centers for action to be taken quickly. Fortunately, due to availability of high-resolution phasor measurement units (PMUs), more event-driven solutions can be captured in real time. In this paper, we propose a data-driven approach for determining fault characteristics using samples of fault trajectories. A random forest regressor (RFR)-based model is used to detect real-time fault location and its duration simultaneously. This model is based on combining multiple uncorrelated trees with state-of-the-art boosting and aggregating techniques in order to obtain robust generalizations and greater accuracy without overfitting or underfitting. Four cases were studied to evaluate the performance of RFR: 1. Detecting fault location (case 1), 2. Predicting fault duration (case 2), 3. Handling missing data (case 3), and 4. Identifying fault location and length in a real-time streaming environment (case 4). A comparative analysis was conducted between the RFR algorithm and state-of-the-art models, including deep neural network, Hoeffding tree, neural network, support vector machine, decision tree, naive Bayesian, and K-nearest neighborhood. Experiments revealed that RFR consistently outperformed the other models in detection accuracy, prediction error, and processing time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of fluid injection-induced fault reactivation using coupled fluid flow and mechanical interface model

The present study is aimed at developing a numerical model to reproduce coupled hydro-mechanical processes associated with fault reactivation by fluid injection in low permeability rock, as part of the DECOVALEX-2019 project Task B. We proposed a modeling approach for simulating the processes using the TOUGH-FLAC simulator, and modeled a fault reactivation experiment conducted at Mont Terri Rock Laboratory in Switzerland. The first step of the study involved benchmark calculations considering a simplified fault plane and geometry. Fluid flow along a fault was modeled using elements of aperture-sized thickness on the basis of Darcy's law and the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by zero-thickness interface elements in FLAC3D upon which a slip and/or separation is allowed. A methodology to connect a TOUGH2 volume element to a FLAC3D interface element was developed for handling the hydro-mechanical interactions on the fault during fluid injection. Two different fault models for describing the evolutions of hydraulic aperture by elastic fracture opening and failure-induced aperture increase were considered in the benchmark calculations. In the coupling process, the changes in geometrical features and hydrological properties induced by mechanical deformation were continuously updated. The transient responses of the fault and host rock to stepwise pressurization were examined during the simulation. The hydro-mechanical behavior, including the injection flow rate, pressure distribution around the borehole, stress conditions, and displacements in normal and shear directions were monitored in the surrounding rock and along the fault. The results of benchmark calculations suggest that the developed model reasonably represents the hydro-mechanical behavior of a fault and the surrounding rock. This modeling approach was applied to the fault reactivation experiment of the Mont Terri Rock Laboratory. In this interpretive modeling, a parametric study was conducted to examine the effects of input parameters regarding in situ stress and fault properties on the hydro-mechanical responses of the fault to water injection. Then, an optimal parameter set to reproduce the field experiment results was chosen by trial-and-error. The injection flow rate and pressure response during fault reactivation closely matched those obtained at the site, which indicates the capability of the model to appropriately capture the progressive pathway evolution during fault reactivation tests at the site. Finally, the anchor displacements were overestimated by the model, but a fair agreement was obtained in terms of the order of magnitude and the variation tendency.

58 GEOSCIENCES↗

The impact of nickel concentration and stacking fault energy on deformation mechanisms in high-purity austenitic Fe-Cr-Ni alloys

Understanding how composition affects deformation mechanisms in austenitic stainless steels is essential for developing accurate predictive models of stress-induced failures and stress corrosion cracking. Nickel (Ni), an element classified as a critical element, plays a crucial role in these processes. It is important to examine how Ni concentration influences stacking fault energy (SFE) and, consequently, the deformation mechanisms of austenitic stainless steels. However, in commercial stainless steels, the effects of other alloying elements and impurities can obscure Ni's role, complicating efforts to isolate its impact. Here, in this study, we use two high-purity Fe-Cr-Ni alloys to investigate how Ni concentration and SFE interact to alter deformation mechanisms and induce martensitic transformation. By combining in situ synchrotron X-ray diffraction (XRD) tensile testing and post-mortem electron microscopy with density functional theory simulations, we gain precise insights into these phenomena. We find that the Fe18Cr10Ni (wt%) alloy, with its low SFE, exhibits higher stacking fault probability, deformation-induced martensitic transformation, and a lesser increase in dislocation density with plastic strain. In contrast, the Fe18Cr14Ni (wt%) alloy, with its higher SFE, shows enhanced deformation twinning and greater dislocation density with increasing strain. These findings from high-purity ternary alloys provide valuable insights that can guide the search for alternative elements to replace Ni while achieving similar effects on phase stability and deformation behavior.

36 MATERIALS SCIENCE↗

The Design of a Fault-Tolerant COTS-Based Bus Architecture for Space Applications

The high-performance, scalability and miniaturization requirements together with the power, mass and cost constraints mandate the use of commercial-off-the-shelf (COTS) components and standards in the X2000 avionics system architecture for deep-space missions. In this paper, we report our experiences and findings on the design of an IEEE 1394 compliant fault-tolerant COTS-based bus architecture. While the COTS standard IEEE 1394 adequately supports power management, high performance and scalability, its topological criteria impose restrictions on fault tolerance realization. To circumvent the difficulties, we derive a "stack-tree" topology that not only complies with the IEEE 1394 standard but also facilitates fault tolerance realization in a spaceborne system with limited dedicated resource redundancies. Moreover, by exploiting pertinent standard features of the 1394 interface which are not purposely designed for fault tolerance, we devise a comprehensive set of fault detection mechanisms to support the fault-tolerant bus architecture.

Chau, Savio N.↗

Development of the Orion Crew-Service Module Umbilical Retention and Release Mechanism

The Orion CSM umbilical retention and release mechanism supports and protects all of the cross-module commodities between the spacecrafts crew and service modules. These commodities include explosive transfer lines, wiring for power and data, and flexible hoses for ground purge and life support systems. The mechanism employs a single separation interface which is retained with pyrotechnically actuated separation bolts and supports roughly two dozen electrical and fluid connectors. When module separation is commanded, either for nominal on-orbit CONOPS or in the event of an abort, the mechanism must release the separation interface and sever all commodity connections within milliseconds of command receipt. There are a number of unique and novel aspects of the design solution developed by the Orion mechanisms team. The design is highly modular and can easily be adapted to other vehiclesmodules and alternate commodity sets. It will be flight tested during Orions Exploration Flight Test 1 (EFT-1) in 2014, and the Orion team anticipates reuse of the design for all future missions. The design packages fluid, electrical, and ordnance disconnects in a single separation interface. It supports abort separations even in cases where aerodynamic loading prevents the deployment of the umbilical arm. Unlike the Apollo CSM umbilical which was a destructive separation device, the Orion design is resettable and flight units can be tested for separation performance prior to flight.Initial development testing of the mechanisms separation interface resulted in binding failures due to connector misalignments. The separation interface was redesigned with a robust linear guide system, and the connector separation and boom deployment were separated into two discretely sequenced events. These changes addressed the root cause of the binding failure by providing better control of connector alignment. The new design was tuned and validated analytically via Monte Carlo simulation. The analytical validation was followed by a repeat of the initial test suite plus test cases at thermal extremes and test cases with imposed mechanical failures demonstrating fault tolerance. The mechanism was then exposed to the qualification vibration environment. Finally, separation testing was performed at full speed with live ordnance.All tests of the redesigned mechanism resulted in successful separation of the umbilical interface with adequate force margins and timing. The test data showed good agreement with the predictions of the Monte Carlo simulation. The simulation proved invaluable due to the number of variables affecting the separation and the uncertainty associated with each. The simulation allowed for rapid assessment of numerous trades and contingency scenarios, and can be easily reconfigured for varying commodity sets and connector layouts.

Separation↗

Stress accumulated mechanisms on strike-slip faults

The tectonic framework causing seismicity on the San Andreas and North Anatolian faults can be understood in terms of plate tectonics. However, the mechanisms responsible for the distribution of seismicity in space and time on these faults are poorly understood. The upper part of the crust apparently behaves elastically in storing energy that is released during an earthquake. The relatively small distances from the fault in which stress is stored argue in favor of a plate with a thickness of 5-10 km. The interaction of this plate with a lower crust that is behaving as a fluid damps the seismic cycling in distances of the order of 10 km from the fault. Low measured heat flow also argues in favor of a thin plate with a low stress level on the fault. Future measurements of stress, strain, and heat flow should help to provide a better understanding of the basic mechanisms governing the behavior of strike-slip faults.

Turcotte, D. L.↗

Toggle release

The invention relates to a pyrotechnic actuated release mechanism which is mechanically two fault tolerant for effecting release. It is particularly well suited for releasably connecting structures to be used in the space environment or in other aerospace applications. The device comprises a fastener plate and fastener body, each attachable to either one of a pair of structures to be joined. The fastener plate and the body are fastenable by a toggle supported at one end on the fastener plate and mounted for universal pivotal movement thereon. At its other end, which is received in a central opening in the fastener body and adapted for limited pivotal movement therein, the toggle is restrained by three retractable latching pins. Each pin is individually retractable by combustion of a pyrotechnic charge. While retraction of all three pins releases the toggle, the fastener is mechanically two fault tolerant since the failure of any single or pair of the latch pins to retract results in an asymmetrical loading on the toggle and its pivotal movement to effect a release. An annular bolt is mounted on the fastener plate as a support for the socket mounting of the toggle whereby its selective axial movement provides a means for pre-loading the toggle.

Graves, Thomas Joseph↗

Double swivel toggle release

A pyrotechnic actuated structural release device is disclosed which is mechanically two fault tolerant for release. The device comprises a fastener plate and fastener body each attachable to one of a pair of structures to be joined. The fastener plate and the fastener body are fastened by a dual swivel toggle member. The toggle member is supported at one end on the fastener plate and mounted for universal pivotal movement thereon. Its other end is received in a central opening in the fastener body, and has a universally mounted retainer ring member. The toggle member is restrained by three retractable latching pins symmetrically disposed in equiangular spacing about the axis of the toggle member and positionable in latching engagement with the retainer ring member on the toggle member. Each pin is retractable by a pyrotechnic charge, the expanding gases of which are applied to a pressure receiving face on the latch pins to effect retraction from the ring member. While retraction of all three pins releases the ring member, the fastener is mechanically two fault tolerant since the failure of any single one or pair of the latch pins to retract results in an asymmetrical loading on the ring member and its dual pivotal movement ensures a release.

King, Guy L.↗

Toggle release

A pyrotechnic actuated structural release device 10 which is mechanically two fault tolerant for release. The device 10 comprises a fastener plate 11 and fastener body 12, each attachable to a different one of a pair of structures to be joined. The fastener plate 11 and body 12 are fastenable by a toggle 13 supported at one end on the fastener plate and mounted for universal pivotal movement thereon. At its other end which is received in a central opening in the fastener body 12 and adapted for limited pivotal movement therein the toggle 13 is restrained by three retractable latching pins 61 symmetrically disposed in equiangular spacing about the axis of the toggle 13 and positionable in latching engagement with an end fitting on the toggle. Each pin 61 is individually retractable by combustion of a pyrotechnic charge 77, the expanding gases of which are applied to a pressure receiving face 67 on the latch pin 61 to effect its retraction from the toggle. While retraction of all three pins 62 releases the toggle, the fastener is mechanically two fault tolerant since the failure of any single one or pair of the latch pins to retract results in an asymmetrical loading on the toggle and its pivotal movement to effect a release. An annular bolt 18 is mounted on the fastener plate 11 as a support for the socket mounting 30, 37 of the toggle whereby its selective axial movement provides a means for preloading the toggle.

Graves, Thomas J.↗

Mechanical proofs of fault-tolerant clock synchronization

The following topics are covered in viewgraph form: (1) introduction to clock synchronization protocols; (2) a schematic formulation of clock synchronization; (3) the interactive convergence algorithm; (4) verification of Schneider's formulation; (5) verification of interactive convergence; (6) a hardware-oriented clock synchronization protocol; (7) verification of Infis/Moore's protocol; and (8) the EHDM specification/verification environment.

Shankar, N.↗

Hardware fault insertion and instrumentation system: Mechanization and validation

Automated test capability for extensive low-level hardware fault insertion testing is developed. The test capability is used to calibrate fault detection coverage and associated latency times as relevant to projecting overall system reliability. Described are modifications made to the NASA Ames Reconfigurable Flight Control System (RDFCS) Facility to fully automate the total test loop involving the Draper Laboratories' Fault Injector Unit. The automated capability provided included the application of sequences of simulated low-level hardware faults, the precise measurement of fault latency times, the identification of fault symptoms, and bulk storage of test case results. A PDP-11/60 served as a test coordinator, and a PDP-11/04 as an instrumentation device. The fault injector was controlled by applications test software in the PDP-11/60, rather than by manual commands from a terminal keyboard. The time base was especially developed for this application to use a variety of signal sources in the system simulator.

Benson, J. W.↗

Two fault tolerant toggle-hook release

A coupling device is disclosed which is mechanically two fault tolerant for release. The device comprises a fastener plate and fastener body, each of which is attachable to a different one of a pair of structures to be joined. The fastener plate and body are coupled by an elongate toggle mounted at one end in a socket on the fastener plate for universal pivotal movement thereon. The other end of the toggle is received in an opening in the fastener body and adapted for limited pivotal movement therein. The toggle is adapted to be restrained by three latch hooks arranged in symmetrical equiangular spacing about the axis of the toggle, each hook being mounted on the fastener body for pivotal movement between an unlatching non-contact position with respect to the toggle and a latching position in engagement with a latching surface of the toggle. The device includes releasable lock means for locking each latch hook in its latching position whereby the toggle couples the fastener plate to the fastener body and means for releasing the lock means to unlock each said latch hook from the latch position whereby the unlocking of at least one of the latch hooks from its latching position results in the decoupling of the fastener plate from the fastener body.

Graves, Thomas Joseph↗

The mechanisms and temperature dependence of superlattice stacking fault formation in the single-crystal superalloy PWA 1480

The mechanism of the formation of superlattice staking faults in the single-crystal nickel-base superalloy PWA 1480 was investigated by observing deformation microstructures in the superalloy single crystals in the temperature range 20-1100 C. Results showed that, in addition to superlattice stacking faults observed after slow strain rate deformation at temperatures from 700 to 950 C, a high-density of superlattice staking faults formed after deformation at 200 C and below. The mechanisms of fault formation, which are different in the high- and the low-temperature regimes, are discussed.

Milligan, Walter W.↗

Flank tectonics of Martian volcanoes

The origin of the numerous terraces on the flanks of the Olympus Mons volcano on Mars, seen on space images to be arranged in a roughly concentric pattern, is investigated. The images of the volcano show that the base of each terrace is marked by a modest but abrupt change in slope, suggesting that these terraces could be thrust faults caused by a compressional failure of the cone. The mechanism of faulting and the possible effect of the interior structure of Olympus Mons was investigated using a numerical model for elastic stresses within a Martian volcano, constructed for that purpose. Results of the analysis supports the view that the terraces on Olympus Mons, as well as on other three Martian volcanoes, including Ascraeus Mons, Arsia Mons, and Pavonis Mons are indeed thrust faults.

Thomas, Paul J.↗

Deep Moonquake Focal Mechanisms: Recovery and Implications

A defining characteristic of deep moonquakes is their tendency to occur with tidal periodicity, prompting previous studies to infer that they are related to the buildup and release of tidal stress within the Moon. In studies of tidal forcing, a key constraint is the focal mechanism: the fault parameters describing the type of failure moonquakes represent. The quality of the lunar seismic data and the limited source/receiver geometries of the Apollo seismic network prohibit the determination of deep moonquake fault parameters using first-motion polarities, as is typically done in terrestrial seismology. Without being able to resolve tidal stress onto a known failure plane, we can examine only gross qualities of the tidal stress tensor with respect to moonquake occurrence, so we cannot fully address the role of tidal stress in moonquake generation. We will examine the extent to which shear (S) and compression (P) wave amplitude ratios can constrain moonquake fault geometry by determining whether, for a given cluster, there exists a focal mechanism that can produce a radiation pattern consistent with the amplitudes measured by the Apollo instruments. Amplitudes are read in the ray coordinate frame, directly from seismograms for which the P and S arrivals are clearly identifiable on all long-period channels of the four Apollo stations. We apply an empirical station correction to account for site effects and the differences between P- and S-wave attenuation. Instead of focusing on the best fitting solution only, we formulate the inverse problem using a falsification criterion: all source orientations that do not reproduce the observed SV/P ratios within an error margin derived from the uncertainty of amplitude readings are rejected. All others are accepted as possible solutions. The inversion is carried out using an exhaustive grid search on a regular grid with predefined step size, encompassing all possible combinations of strike, dip and slip. To assess the sensitivity of the inversion for the uncertainty of the lunar interior structure, we carry out repeated inversions with different velocity structures. Our data set consist of a total of 106 events from 25 deep moonquake clusters. The largest contribution of 37 events originates from the most active cluster, A001, while other clusters are represented by 1 to 9 events. Since the definition of a cluster implies that all events share the same source orientation, a comparison of the inversion results of all events from one cluster will reduce ambiguities of the inversion. Once we obtain a suite of fault parameters for a given source, we can attempt to further constrain the focal mechanism with refined analyses of tidal stresses and predictions based on synthetic seismograms.

Knapmeyer, Martin↗