Search NASA⌕ Search

SEARCH · Search NASA

Results for “Femtosecond lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Precision of FLEET Velocimetry Using High-speed CMOS Camera Systems

Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 micro sec, precisions of 0.5 m/s in air and 0.2 m/s in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision High Speed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

Peters, Christopher J.↗

FLEET Velocimetry Measurements on a Transonic Airfoil

Femtosecond laser electronic excitation tagging (FLEET) velocimetry was used to study the flowfield around a symmetric, transonic airfoil in the NASA Langley 0.3-m TCT facility. A nominal Mach number of 0.85 was investigated with a total pressure of 125 kPa and total temperature of 280 K. Two-components of velocity were measured along vertical profiles at different locations above, below, and aft of the airfoil at angles of attack of 0 deg, 3.5 deg, and 7deg. Measurements were assessed for their accuracy, precision, dynamic range, spatial resolution, and overall measurement uncertainty in the context of the applied flowfield. Measurement precisions as low as 1 m/s were observed, while overall uncertainties ranged from 4 to 5 percent. Velocity profiles within the wake showed sufficient accuracy, precision, and sensitivity to resolve both the mean and fluctuating velocities and general flow physics such as shear layer growth. Evidence of flow separation is found at high angles of attack.

Burns, Ross A.↗

Application of STARFLEET Velocimetry in the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel

Selective two-photon absorptive resonance femtosecond laser electronic excitation tagging (STARFLEET) velocimetry is demonstrated for the first time in a NASA Langley wind tunnel with high repetition-rate and single-shot imaging. Experiments performed in the 0.3-meter Transonic Cryogenic Tunnel (TCT) allowed for testing at 300 K over a range of pressures (124 to 517 kPa) and Mach numbers (0.2-0.8) for freestream conditions and flow behind a cylindrical model. Measurement precision and accuracy are determined for the current set of experiments, as are signal intensity and lifetime. Precisions of 3-5 m/s (based on one standard deviation) were typical in the experiment; precisions better than 2% of the mean velocity were obtained for some of the highest velocity conditions. Agreement within a mean error of 3 m/s between STARFLEET freestream velocity measurements and facility DAS readings is demonstrated. STARFLEET is also shown to return spatially-resolved velocity profiles, though some binning of the signal is required.

STARFLEET↗

FLEET Velocimetry in the Common Research Model’s Wing Wake

Femtosecond laser electronic excitation tagging was used to make velocity measurements in the wake of the wing of the Common Research Model (CRM). Experiments were performed in the NASA Langley Research Center’s National Transonic Facility over a range of tunnel operating conditions. Pressures ranged from 205 to 411 kPa, temperatures from 278 to 323 K, and Mach from 0.1 to 0.9. Velocity was also determined over a range of model angles of attack. Time-averaged velocity results were obtained in both air and nitrogen, while single-shot velocity was obtained under certain tunnel operating conditions. Spatially-resolved, two dimensional, single component velocity measurements were achieved using a newly-developed laser scanning technique, which proved sufficiently sensitive to measure an approximately 5% velocity deficit in the wing wake region of the CRM.

Daniel T Reese↗

A Review of Recent Advances in Heat Exchanger Technology and Future Applications

This talk describes current and historical efforts concerning the development of condensing heat exchangers for use in space systems. These devices are used for a wide range of applications, including humidity/environmental control and multiphase fluid systems in Earth and in space. Therefore, keeping these systems running consistently and with minimal downtime/repairs is a high priority for exploration life support. Recent advances in low gravity capillary fluidics can be applied to newer systems and offer continuous operation in the event of a system pump failure or blockage. Additionally, new methods in femtosecond laser processing have been used to create microbial resistant surfaces with unique wetting characteristics. This research builds on experiments at both Glenn Research Center and Johnson Space Center. Future applications of this work will also be discussed, including water processing and plant growth systems.

heat exchanger↗

FLEET and PLIF Velocimetry Within A Mach 10 Hypersonic Air Flow

Femtosecond laser electronic excitation tagging (FLEET) and planar laser-induced fluorescence (PLIF) velocity measurements utilizing molecular tagging velocity (MTV) methods from three recent test campaigns conducted at the 31-in Mach 10 Air Tunnel at the NASA Langley Research Center are highlighted within. The FLEET measurements reported here include the first direct measurement of freestream velocity at this hypersonic wind tunnel facility. Measurement challenges were exasperated by the low gas density of the Mach 10 air freestream (~0.4% of standard temperature and pressure conditions) and even lower gas densities within the hypersonic wake of a 70-degree sphere-cone model. In addition, the hypersonic freestream and very low speed velocities in the wake also tested the measurement dynamic range. To complement the FLEET measurements in the wake of the sphere-cone model, PLIF velocimetry using seeded nitric oxide was also performed. While NO-PLIF velocimetry has been performed at this facility several times by previous researchers, the use of a 1D diffractive optical element for NO-PLIF velocimetry is reported here for the first time. The 1D DOE enabled the generation of up to 75 laser lines simultaneously and improved the spatial extent of the measurement three times compared to previous work. This enabled a wide velocity measurement plane of approximately 130 mm x 130 mm. The velocimetry methods demonstrated here are expected to improve wind tunnel characterization, provide critical data to validate CFD codes, and improve the design of flight vehicles for planetary entry.

FLEET↗

FLEET and PLIF Velocimetry Within A Mach 10 Hypersonic Air Flow

Femtosecond laser electronic excitation tagging (FLEET) and planar laser-induced fluorescence (PLIF) velocity measurements utilizing molecular tagging velocity (MTV) methods from three recent test campaigns conducted at the 31-in Mach 10 Air Tunnel at the NASA Langley Research Center are highlighted within. The FLEET measurements reported here include the first direct measurement of freestream velocity at this hypersonic wind tunnel facility. Measurement challenges were exasperated by the low gas density of the Mach 10 air freestream (~0.4% of standard temperature and pressure conditions) and even lower gas densities within the hypersonic wake of a 70-degree sphere-cone model. In addition, the hypersonic freestream and very low speed velocities in the wake also tested the measurement dynamic range. To complement the FLEET measurements in the wake of the sphere-cone model, PLIF velocimetry using seeded nitric oxide was also performed. While NO-PLIF velocimetry has been performed at this facility several times by previous researchers, the use of a 1D diffractive optical element for NO-PLIF velocimetry is reported here for the first time. The 1D DOE enabled the generation of up to 75 laser lines simultaneously and improved the spatial extent of the measurement three times compared to previous work. This enabled a wide velocity measurement plane of approximately 130 mm x 130 mm. The velocimetry methods demonstrated here are expected to improve wind tunnel characterization, provide critical data to validate CFD codes, and improve the design of flight vehicles for planetary entry.

FLEET↗

High Precision and Spatial Resolution Chemical Interrogation of Planetary Materials Using fs-LA/LIBS in Tandem With Multi-Collector ICP-MS

Combining femtosecond laser ablation (fs-LA) with laser-induced breakdown spectroscopy (LIBS), together with multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS), can provide remarkable insights into the composition, structure, and therefore geologic history of planetary materials and their terrestrial analogs. Using the Applied Spectra iX-fs-Tandem LA-LIBS Instrument and the Nu SP1700 MC-ICP-MS housed within the Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center, we present preliminary tandem fs-LA-(MC)-ICP-MS/LIBS measurements of planetary analog materials. The synergistic integration of fs-LA-LIBS offers high spatial resolution elemental mapping, enabling the identification of microscale variations within samples. Simultaneously, the MC-ICP-MS can deliver precise isotopic analyses, and integrating the two datasets yields a wealth of geochemical information for a given sample. LA-based chemical mapping experiment designs are contingent on the information sought (i.e., quantitative, or semi-quantitative) and the preferred or available volume of material removed for the analysis. For example, occasionally, there are significant limitations in the depth of ablation due to the sample value, the amount of material available, or simply the need to coordinate with other in-situ techniques. In these limited sample scenarios, the “depth-controlled” chemical maps allow for precise post-mapping ion-polishing of the sample, while the isotopic and elemental maps can be used for targeting future analyses (e.g., conventional LA analyses, SIMS analyses, and micro milling for solution ICP-MS/TIMS). The emerging methodology will establish a powerful tool for investigation of astromaterials and materials returned by future planetary sample science missions.

Jacob B Setera↗

Spatially-Resolved Freestream Velocity Measurements at the NASA Langley 31-Inch Mach 10 Air Tunnel Using FLEET

Freestream velocity measurements in the NASA Langley 31-inch Mach 10 wind tunnel are reported in this paper using Femtosecond Laser Electronic Excitation Tagging (FLEET). The freestream measurements acquired during the January 2023 test campaign were the first direct measurement of freestream velocity in this hypersonic wind tunnel facility. Spatial distributions of time-averaged and instantaneous velocity measurements were obtained at all three typical wind tunnel freestream unit Reynolds number conditions of Re∞/L = 1.8∙106 m-1, 3.6∙106 m-1, and 6.4∙106 m-1, though the current paper focuses on centerline measurements for the three Re∞/L and spatial distributions for one Re∞/L. Measured values for time-averaged velocity and mean of the instantaneous velocity at the wind tunnel centerline agree within 5 m/s or 0.4% of the calculated velocity from the facility data acquisition system. Measurements acquired at locations away from the wind tunnel centerline reveal the spatial extent of the core flow of the hypersonic facility.

FLEET↗

Spatially-Resolved Freestream Velocity Measurements at the NASA Langley 31-Inch Mach 10 Air Tunnel Using FLEET

Freestream velocity measurements in the NASA Langley 31-inch Mach 10 wind tunnel are reported in this paper using Femtosecond Laser Electronic Excitation Tagging (FLEET). The freestream measurements acquired during the January 2023 test campaign were the first direct measurement of freestream velocity in this hypersonic wind tunnel facility. Spatial distributions of time-averaged and instantaneous velocity measurements were obtained at all three typical wind tunnel freestream unit Reynolds number conditions of Re∞/L = 1.8∙106 m-1, 3.6∙106 m-1, and 6.4∙106 m-1, though the current paper focuses on centerline measurements for the three Re∞/L and spatial distributions for one Re∞/L. Measured values for time-averaged velocity and mean of the instantaneous velocity at the wind tunnel centerline agree within 5 m/s or 0.4% of the calculated velocity from the facility data acquisition system. Measurements acquired at locations away from the wind tunnel centerline reveal the spatial extent of the core flow of the hypersonic facility.

FLEET↗

Ultrashort Pulsed Laser Treatment: A Novel Sterilization Method for Planetary Protection

Introduction: On missions seeking signs of potential life elsewhere in the solar system, we have an obligation not to bring our own Earthly life with us. Reducing the bioburden (number of living microbes) on spacecraft is therefore required by the COSPAR Policy on Planetary Protection to target bodies that are of interest for understanding the origins of life (such as Mars). The method of spacecraft sterilization predominantly used by NASA is Heat Microbial Reduction, which is typically incompatible with heat-sensitive components such as optics and electronics, and is expensive and time-consuming. Here, we present preliminary results on a novel method for spacecraft hardware sterilization: high-intensity ultrashort (femtosecond) pulsed laser illumination. Femtosecond lasers use extremely high photon fluxes (10^29 photons/sec*cm^2, ~0.03 J/cm^2) in extremely short pulses, which can inactivate even stress-tolerant microbial spores with minimal damage to the spacecraft surface. This rapid sterilization technique could be carried out in situ in a spacecraft assembly clean room using high-speed surface scanning, saving critical time and resources. It also can potentially remove or reduce debris from inactivated cells and spores. Methods: To develop optimal laser processing parameters for inactivating planetary protection-relevant organisms on metal surfaces, we inoculated 1-cm^2 mirror-polished aluminum coupons with Bacillus subtilis spores (2x10^5 spores/coupon) and tested the effect of several parameters, including pulse count and fluence. Sterilization effectiveness was measured by recovering spores using a PVA (polyvinyl acetate) peel and conducting serial dilution and plating for colony-forming units (CFUs). Results: Our results show that pulse count and fluence both affect sterilization effectiveness and that within a certain pulse count range, increasing fluence increases effectiveness. We have demonstrated the ability to reduce viable microbial counts by at least 10^-4. Future work will include testing higher abundances and different species of microorganisms, effectiveness on complex surfaces, compatibility with sensitive surfaces, and quantification of cell debris removal. Femtosecond pulsed laser illumination has the potential to provide dramatic savings in both cost and schedule over current methods of bioburden reduction to prevent forward contamination. It may also have the potential for use in surface sterilization of returned samples to prevent back contamination.

Planetary Protection; Lasers; Sterilization; Bacil↗

Tetravalent chromium (Cr(4+)) as laser-active ion for tunable solid-state lasers

Major accomplishments under NASA grant NAG-1-1346 are summarized. (1) numerical modeling of the four mirror astigmatically compensated, Z-fold cavity was performed and several design parameters to be used for the construction of a femtosecond forsterite laser were revealed by simulation. (2) femtosecond pulses from a continuous wave mode-locked chromium doped forsterite laser were generated. The forsterite laser was actively mode-locked using an acousto-optic modulator operating at 78 MHz with two Brewster high dispersion glass prisms for intra-cavity chirp compensation. Transform-limited sub-100-fs pulses were routinely generated in the TEM(sub 00) mode with 85 mW of continuous power tunable over 1230-1280 nm. The shortest pulses of 60-fs pulsewidth were measured. (3) Self-mode-locked operation of the Cr:forsterite laser was achieved. Synchronous pumping was used to mode lock the forsterite laser resulting in picosecond pulses, which in turn provided the starting mechanism for self-mode-locking. The pulses generated had an FWHM of 105 fs and were tunable between 1230-1270 nm. (4) Numerical calculations indicated that the pair of SF 14 prisms used in the cavity compensated for quadratic phase but introduced a large cubic phase term. Further calculations of other optical glasses indicated that a pair of SFN 64 prisms can introduce the same amount of quadratic phase as SF 14 prisms but introduce a smaller cubic phase. When the SF 14 prisms were replaced by SFN 64 prisms the pulsewidth was reduced to 50 fs. Great improvement was observed in the stability of the self mode-locked forsterite laser and in the ease of achieving mode locking. Using the same experimental arrangement and a new forsterite crystal with improved FOM the pulse width was reduced to 36 fs.

Seas, A.↗

Generation of sub-100-fs pulses from a CW mode-locked chromium-doped forsterite laser

Generation of femtosecond pulses from a continuous-wave mode-locked chromium-doped forsterite laser is reported. The forsterite laser was actively mode locked by using an acoustooptic modulator operating at 78 MHz with two Brewster high-dispersion glass prisms for intracavity chirp compensation. Transform-limited sub-100-fs pulses were routinely generated in the TEM(00) mode with 85 mW of continuous power (with 1 percent output coupler), tunable over 1230-1280 nm. The shortest pulses measured had a 60-fs pulse width.

Seas, A.↗

Microbial Methods for Testing a Novel Spacecraft Bioburden Reduction Method

In order to circumvent the contamination of microorganisms in both extraterrestrial and terrestrial environments, spacecraft hardware must often be sterilized. Current sterilization practices are both time-consuming and expensive. Techniques such as dry heat sterilization and scattered/localized electric field enhancements are incompatible with a variety of hardware materials as well as complex surface shapes. Our group is testing a novel femtosecond pulsed laser for the rapid sterilization of spacecraft hardware using high photon fluxes, which is both an efficient and effective technique to ensure a reduced microbial burden aboard spacecraft. This method is likely to be effective because microorganisms have not encountered high photon fluxes in their evolutionary history and thus contain no protective mechanisms against them. To assess the effectiveness of pulsed laser sterilization, we used a combination of scanning electron microscopy and elemental analysis for the examination of damaged spores on metal coupons, as well as microbiology methods for spore assays. The surfaces of metal coupons inoculated with Bacillus subtilis were illuminated with femtosecond pulses at various wavelengths below the damage threshold for the aluminum. After laser treatment, metal coupon samples were sonicated to dislodge spores, serially diluted, and finally plated and incubated. Results show that sterilization efficiency is favorable in some conditions. The NASA standards for spore assays are a preliminary demonstration in establishing the trend in ability to kill spores. The results show potential for the dual pulse illumination method as a sterilization technique for planetary protection applications.

Maha S Ulhaq↗

Tetravalent chromium (Cr(4+)) as laser-active ion for tunable solid-state lasers

Generation of femtosecond pulses from a continuous-wave mode-locked chromium-doped forsterite (Cr(4+):Mg2SiO4) laser has been accomplished. The forsterite laser was actively mode-locked using an acousto-optic modulator operating at 78 MHz with two Brewster high-dispersion glass prisms for intra-cavity chirp compensation. Transform-limited sub-100-fs pulses were routinely generated in the TEM(sub 00) mode with 85 mW of continuous power (with 1 percent output coupler), tunable over 1230-1280 nm. The shortest pulses of 60-fs pulsewidth were measured.

Seas, A.↗

The Interference of the Dynamically Squeezed Vibrational Wave Packets

An electronic excitation of a molecule by a sequence of two femtosecond phase-locked laser pulses is considered. In this case the interference between the vibrational wave packets induced by each of the subpulses within a single molecule takes place. It is shown that due to the dynamical squeezing effect of a molecular vibrational state the interference of the vibrational wave packets allows one to measure the duration of a femtosecond laser pulse. This can be achieved experimentally by measuring the dependence of the integral fluorescence of the excited molecule on the delay time between the subpulses. The interference can lead to a sharp peak (or to a down-fall) in that dependence, the width of which is equal to the duration of the laser pulse. It is shown that finite temperature of the medium is favorable for such an experiment.

Vinogradov, An. V.↗