Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filter Absorption Coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

40 records · Page 3

Soot Particle Studies - Instrument Inter-Comparison – Project Overview

An inter-comparison study of instruments designed to measure the microphysical and optical properties of soot particles was completed. The following mass-based instruments were tested: Couette Centrifugal Particle Mass Analyzer (CPMA), Time-of-Flight Aerosol Mass Spectrometer - Scanning Mobility Particle Sizer (AMS-SMPS), Single Particle Soot Photometer (SP2), Soot Particle-Aerosol Mass Spectrometer (SP-AMS) and Photoelectric Aerosol Sensor (PAS2000CE). Optical instruments measured absorption (photoacoustic, interferometric, and filter-based), scattering (in situ), and extinction (light attenuation within an optical cavity). The study covered an experimental matrix consisting of 318 runs that systematically tested the performance of instruments across a range of parameters including: fuel equivalence ratio (1.8 {le} {phi} {le} 5), particle shape (mass-mobility exponent (D{sub f m}), 2.0 {le} D{sub f m} {le} 3.0), particle mobility size (30 {le} d{sub m} {le} 300 nm), black carbon mass (0.07 {le} m{sub BC} {le} 4.2 fg) and particle chemical composition. In selected runs, particles were coated with sulfuric acid or dioctyl sebacate (DOS) (0.5 {le} {Delta}r{sub ve} {le} 201 nm) where {Delta}r{sub ve} is the change in the volume equivalent radius due to the coating material. The effect of non-absorbing coatings on instrument response was determined. Changes in the morphology of fractal soot particles were monitored during coating and denuding processes and the effect of particle shape on instrument response was determined. The combination of optical and mass based measurements was used to determine the mass specific absorption coefficient for denuded soot particles. The single scattering albedo of the particles was also measured. An overview of the experiments and sample results are presented.

54 ENVIRONMENTAL SCIENCES↗

Absorption at San Antonio with 3-Wavelength Photo Acoustic Soot Spectrometer, Tricolor Absorption Photometer (ASAPT) Field Campaign Report

Fine particulate matter (PM2.5; particulate matter with an aerodynamic diameter of 2.5μm and smaller) samples were collected at the University of Texas, San Antonio (UTSA) campus (29.57901, -98.62889) from May 15-30. An additional measurement at the UTSA site included aerosol absorption coefficient of PM1 (particulate matter with an aerodynamic diameter of 1.0μm and smaller) using a tricolor absorption photometer (TAP) (Brechtel Mfg. Inc., Hayward, California). The sampling site is approximately 15 miles northwest of downtown San Antonio and in close proximity to major highway 10 and is just south of a forested area. The setup of the sampler and TAP and collection of PM2.5 samples were completed by Baylor University’s graduate student, Subin Yoon. Three three-wavelength photoacoustic soot spectrometers (PASS-3s) were shipped to San Antonio for testing and possible data collection. R. Subramanian went to San Antonio to lead this effort with assistance from Yoon. Each instrument had a critical flaw that inhibited its use for this campaign. Two instruments had low laser power for each wavelength; in addition, there were power and overheating issues with the one instrument that was installed on a test basis. The third instrument had computer issues that impeded any testing. In short, these three instruments would require a major overhaul in terms of lasers and computer systems to be brought back to field capability. As a result, the filter-based optical measurements were added to the campaign as an alternate measurement that would provide mass absorption efficiency at a single wavelength, but no scattering measurement. The TAP instrument was successfully installed and collected data for San Antonio, but full use of the data would have required a co-located scattering measurement. This campaign was co-located with a Texas Commission on Environmental Quality (TCEQ) ozone field study. That TCEQ field study was a collaboration of the University of Houston (PI James Flynn), Rice University (Co-PI Robert Griffen), and Baylor University (Co-PIs Rebecca Sheesley and Sascha Usenko).

aerosols, tricolor absorption photometer, three-wa↗

Impact of Irradiation-Induced Filter Heating on Calibration of NIR-Longpass-Filtered Reference Solar Cells

Reference solar cells play a crucial role in determining the performance of photovoltaic (PV) devices. In the performance calibration chain of mainstream single-junction PV technologies, common reference cell types include Si, KG-filtered Si, and GaAs cells. For emerging multijunction (MJ) PV technologies, such as CdTe/Si and perovskite/Si, Si reference cells with colored glass near-infrared-longpass (LP) filters like Schott RG-715 and 850 glass have been proposed. They offer a better spectral response that matches the bottom junctions of the emerging MJs, which could lead to lower uncertainties in performance measurements. However, this article reveals a prominent decrease in short-circuit current (ISC) during National Renewable Energy Laboratory's primary calibration over the course of minutes when using this type of LP-filtered reference cell, which could result in unacceptable measurement errors. Unlike quartz or KG filter glasses, LP colored glass filters demonstrate temperature-sensitive cut-on wavelength. When incident irradiance reaches these LP-filtered reference cells, the increased temperature due to light absorption causes a shift of the cut-on to longer wavelength. As a result, the device I SC exhibits a continuous decrease (approximately a 2.5% drop with RG850 LP filter in a 5-min duration) even when the device temperature is controlled at 25 degrees C. To address the temperature gradient issue between colored glass LP filter and the reference cell, we propose the direct integration of thin-film LP semiconductor layer on reference cells. This type of LP-filter-integrated cell has shown minimal temperature-related I SC variation and can serve as a more reliable reference cell source for accurate performance measurements.

14 SOLAR ENERGY↗

Land use regression models for the oxidative potential of fine particles (PM2.5) in five European areas

Highlights: • OP moderately correlated (r ~.6) with PM{sub 2.5} mass, NO{sub 2}, and elemental constituents. • OP{sup AA} and OP{sup GSH} LUR models were developed and evaluated for five areas. • Three reasonably performing (R{sup 2}: .45–.58) OP{sup AA} LUR models in hold-out validation. • OP{sup GSH} models were not robust to new coefficients derived against sub-samples of sites. Oxidative potential (OP) of particulate matter (PM) is proposed as a biologically-relevant exposure metric for studies of air pollution and health. We aimed to evaluate the spatial variability of the OP of measured PM{sub 2.5} using ascorbate (AA) and (reduced) glutathione (GSH), and develop land use regression (LUR) models to explain this spatial variability. We estimated annual average values (m{sup −3}) of OP{sup AA} and OP{sup GSH} for five areas (Basel, CH; Catalonia, ES; London-Oxford, UK (no OP{sup GSH}); the Netherlands; and Turin, IT) using PM{sub 2.5} filters. OP{sup AA} and OP{sup GSH} LUR models were developed using all monitoring sites, separately for each area and combined-areas. The same variables were then used in repeated sub-sampling of monitoring sites to test sensitivity of variable selection; new variables were offered where variables were excluded (p > .1). On average, measurements of OP{sup AA} and OP{sup GSH} were moderately correlated (maximum Pearson's maximum Pearson's R = = .7) with PM{sub 2.5} and other metrics (PM{sub 2.5}absorbance, NO{sub 2}, Cu, Fe). HOV (hold-out validation) R{sup 2} for OP{sup AA} models was .21, .58, .45, .53, and .13 for Basel, Catalonia, London-Oxford, the Netherlands and Turin respectively. For OP{sup GSH}, the only model achieving at least moderate performance was for the Netherlands (R{sup 2} = .31). Combined models for OP{sup AA} and OP{sup GSH} were largely explained by study area with weak local predictors of intra-area contrasts; we therefore do not endorse them for use in epidemiologic studies. Given the moderate correlation of OP{sup AA} with other pollutants, the three reasonably performing LUR models for OP{sup AA} could be used independently of other pollutant metrics in epidemiological studies.

54 ENVIRONMENTAL SCIENCES↗