Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Filtration of bioaerosols using a granular metallic filter with micrometer-sized collectors

Several experimental studies with granular bed filters composed of micrometer-sized spherical or sintered metallic granules have demonstrated their use in aerosol filtration. However, the effectiveness of these metallic membrane filters against bioaerosols has not been established. In this work, the filtration efficiency and filter quality of these filters against airborne B. subtilis endospore and MS2 virus were determined as a function of face velocity and loading time. In experiments, a physical removal efficiency greater than 99.9% and a viable removal efficiency of greater than 5-log were observed for both bacterial spore and viral aerosols. A lower face velocity produced both higher collection efficiency and filter quality for virus but was not statistically significant for spore filtration. Although the filter had high filtration efficiency of the test bioaerosols, the filter's high pressure drop resulted in a low filter quality (0.25-0.75 kPa- 1). Overall, filters with micrometer-sized collectors capture bioaerosols effectively but their applications in aerosol filtration may be limited by their high pressure drop.

aerosol↗

SU-F-I-75: Half-Value Layer Thicknesses and Homogeneity Coefficients for Fluoroscopic X-Ray Beam Spectra Incorporating Spectral Filtration

Purpose: The purpose of this investigation is to quantify various first half-value-layers (HVLs), second HVLs and homogeneity coefficients (HCs) for a state-of-the-art fluoroscope utilizing spectral (copper) filtration. Methods: A Radcal (Monrovia, Ca) AccuPro dosimeter with a 10×6-6 calibrated ionization chamber was used to measure air kerma for radiographic x-ray exposures made on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope operated in the service mode. The ionization chamber was centered in the x-ray beam at 72 cm from the focal spot with a source-to-image-distance of 120 cm. The collimators were introduced to limit the x-ray field to approximately 5 cm × 5 cm at the ionization chamber plane. Type-1100 aluminum filters, in 0.5 mm increments, were used to determine the HVL. Two HVL calculation methods were used, log-linear interpolation and Lambert-W interpolation as described by Mathieu [Med Phys, 38(8), 4546 (2011)]. Multiple measurements were made at 60, 80, 100, 120 kVp at spectral filtration thicknesses of 0, 0.1, 0.3, 0.6 and 0.9 mm. Results: First HVL, second HVL, and HCs are presented for the fluoroscopic x-ray beam spectra indicated above, with nearly identical results from the two interpolation methods. Accuracy of the set kVp was also determined and deviated less than 2%. First HVLs for fluoroscopic x-ray beam spectra without spectral filtration determined in our study were 7%–16% greater than previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. However, the FDA minimum HVL requirements changed since that publication, requiring larger HVLs as of 2006. Additionally, x-ray tube and generator architecture have substantially changed over the last 15 years providing different beam spectra. Conclusion: X-ray beam quality characteristics for state-of-the-art fluoroscopes with spectral filtration have not been published. This study provides reference data which will be useful for defining beam qualities encountered on fluoroscopes using spectral filtration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploration Mission Particulate Matter Filtration Technology Performance Testing in a Simulated Spacecraft Cabin Ventilation System

Human deep space exploration missions will require advances in long-life, low maintenance airborne particulate matter filtration technology. As one of the National Aeronautics and Space Administrations (NASA) developments in this area, a prototype of a new regenerable, multi-stage particulate matter filtration technology was tested in an International Space Station (ISS) module simulation facility. As previously reported, the key features of the filter system include inertial and media filtration with regeneration and in-place media replacement techniques. The testing facility can simulate aspects of the cabin environment aboard the ISS and contains flight-like cabin ventilation system components. The filtration technology test article was installed at the inlet of the central ventilation system duct and instrumented to provide performance data under nominal flow conditions. In-place regeneration operations were also evaluated. The real-time data included pressure drop across the filter stages, process air flow rate, ambient pressure, humidity and temperature. In addition, two video cameras positioned at the filtration technology test articles inlet and outlet were used to capture the mechanical performance of the filter media indexing operation under varying air flow rates. Recent test results are presented and future design recommendations are discussed.

particulate matter filtration↗

Graphene-Based Filtration Media for Spacecraft Potable Water Systems: An Early Investigation

Graphene-based materials have allowed fundamental advances in fields such as energy storage, electronics development, material science, optics, medicine, and water processing due to its unique two-dimensional structure, mechanical robustness, large surface, and high conductivity. However, little to no effort has been devoted to exploiting and studying these materials to develop new water technologies suited for spacecraft applications. One such application is the potential use of graphene-based materials as filtration media for reclaimed water. Therefore, studying the adsorptive performance of these new materials becomes crucial in identifying the opportunity to replace/upgrade State-of-the-Art filtration media currently used in space vehicles with water-recovery capability; especially if consumable requirements can be lessened as a result of extended filtration capacity. This early life-support-systems investigation pioneers in graphene-research by testing a number of graphene-based materials in comparative adsorption and antimicrobial experiments where contaminant removal efficiency, maximum adsorption capacity, and log reduction are probed. This preliminary investigation informs on the practicability of using graphene-based materials as filtration media and provides a discussion on the scaling-up and optimization of this prospective filtration technology for spacecraft potable water systems.

graphene↗

Graphene-Based Filtration Media for Spacecraft Potable Water Systems: An Early Investigation

Graphene-based materials have allowed fundamental advances in fields such as energy storage, electronics development, material science, optics, medicine, and water processing due to their unique two-dimensional structure, mechanical robustness, large surface, and high conductivity. However, little to no effort has been devoted to exploiting and studying these materials to develop new water technologies suited for spacecraft applications. One such application is the potential use of graphene-based materials as filtration media for reclaimed water. Therefore, studying the adsorptive performance of these new materials becomes crucial in identifying the opportunity to replace/upgrade state-of-the-art filtration media currently used in space vehicles with water recovery capability; especially if consumable requirements can be lessened as a result of extended filtration capacity. This early Life-Support-Systems investigation pioneers in graphene research by testing a number of graphene-based materials in comparative adsorption and antimicrobial experiments where contaminant removal efficiency, maximum adsorption capacity, and bacterial reduction are probed. This preliminary investigation informs on the practicality of using graphene-based materials as filtration media and provides a discussion on the scaling-up and optimization of this prospective filtration technology for spacecraft potable water systems.

graphene↗

Research Update: Liquid gated membrane filtration performance with inorganic particle suspensions

Membrane filtration technology is widely used across several industries. But its efficiency is plagued by fouling, which ultimately deteriorates the membrane’s performance. This paper provides a research update on the biologically inspired liquid-enabled gating mechanism that acts as a novel filtration and separation approach offering reduction in transmembrane pressure (TMP), improved throughput, and reduced fouling. We study the performance of such Liquid Gated Membranes (LGMs) and present their benefits for filtration in the presence of model inorganic (nanoclay particles) fouling. We show over twofold higher throughput, nearly threefold longer time to foul, more than 60% reduction in irreversible fouling, ability to return to baseline pressures after backwashing along with reduction in use of backwash water, and 10%-15% reduction in TMP for filtration of nanoclay particles. Fouling models exhibit not only delayed onset of fouling for LGMs compared to the control but also different fouling characteristics. These results demonstrate the potential of the liquid gating mechanism, which can lead to breakthroughs in membrane technology applications in particle filtration, microfiltration, and ultrafiltration.

36 MATERIALS SCIENCE↗

Assessment of a Filtration Waste Qualification Method for LAWPS

The Low-Activity Waste Pretreatment System (LAWPS) facility is planned to pretreat Hanford tank waste supernate by filtering solids and processing through ion exchange columns to remove cesium. The filtration process is achieved through cross flow filtration using a stainless steel Mott filter with a 0.1-micron grade. The goal of this effort was to assess whether a batch, or dead end, filtration (DEF) device replicating the LAWPS cross flow filter could be employed to qualify each feed campaign prior to delivery to LAWPS. The objective for filtration feed qualification is to determine whether the cross-flow filters deployed in LAWPS will remove solids while maintaining a de minimus flow rate of permeate. To that end, the DEF was tested with simulants and the results compared with those obtained from cross flow filtration tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NSRD-20, Functional Testing of Novel MTC HEPA Filtration Media

To improve the safety of Department of Energy (DOE) nuclear facilities, this project aimed to develop ceramic high efficiency particulate air (HEPA) filters that also create a low pressure-drop (dP) in use. The filters under consideration use mini-tubular ceramic (MTC) HEPA filtration media made with different architectures. Once successful, this project will reduce life-cycle costs, including safety basis, operational, and waste-disposal costs. The technology’s mini-tubular geometry is known to reduce dP when compared to flow through membranes of equivalent mass and surface area. Low dP facilitates retrofitting advanced filters into existing DOE facilities to make them safer while simultaneously reducing operational costs. Operations of ventilation systems are a key cost driver for DOE nuclear facilities; reducing dP can significantly reduce DOE’s operational costs. However, the filtration efficiency (FE) of this type of filtration media depends on the architecture of the filter media in an unknown way and requires testing. Functional testing of filtration media with different architectures will establish the performance of the filtration media and will enable development of guidance on design requirements to optimize filter performance.

36 MATERIALS SCIENCE↗

Effect of filtration on rolling-element-bearing life in contaminated lubricant environment

Fatigue tests were conducted on groups of 65 millimeter-bore ball bearings under four levels of filtration with and without a contaminated MIL-L-23699 lubricant. The baseline series used noncontaminated oil with 49 micron absolute filtration. In the remaining tests contaminants of the composition found in aircraft engine filters were injected into the filter's supply line at a constant rate of 125 milligrams per bearing-hour. The test filters had absolute particle removal ratings of 3, 30, 49, and 105 microns (0.45, 10, 30, and 70 microns nominal), respectively. Bearings were tested at 15,000 rpm under 4580 newtons radial load. Bearing life and running tract condition generally improved with finer filtration. The 3 and 30 micron filter bearings in a contaminated lubricant had statistically equivalent lives, approaching those from the baseline tests. The experimental lives of 49 micron bearings were approximately half the baseline bearing's lives. Bearings tested with the 105 micron filter experienced wear failures. The degree of surface distress, weight loss, and probable failure mode were found to be dependent on filtration level, with finer filtration being clearly beneficial.

Loewenthal, S. H.↗

Pharmacologic Atrial Natriuretic Peptide Reduces Human Leg Capillary Filtration

Atrial natriuretic peptide (ANP) is produced and secreted by atrial cells. We measured calf capillary filtration rate with prolonged venous-occlusion plethysmography of supine healthy male subjects during pharmacologic infusion of ANP (48 pmol/kg/min for 15 min; n = 6) and during placebo infusion (n = 7). Results during infusions were compared to prior control measurements. ANP infusion increased plasma (ANP) from 30 +/- 4 to 2,568 +/- 595 pmol/L. Systemic hemoconcentration occurred during ANP infusion: mean hematocrit and plasma colloid osmotic pressure increased 4.6 and 11.3%, respectively, relative to preinfusion baseline values (p less than 0.05). Mean calf filtration, however, was significantly reduced from 0.15 to 0.08 ml/100 ml/min with ANP. Heart rate increased 20% with ANP infusion, whereas blood pressure was unchanged. Calf conductance (blood flow/ arterial pressure) and venous compliance were unaffected by ANP infusion. Placebo infusion had no effect relative to prior baseline control measurements. Although ANP induced systemic capillary filtration, in the calf, filtration was reduced with ANP. Therefore, pharmacologic ANP infusion enhances capillary filtration from the systemic circulation, perhaps at upper body or splanchnic sites or both, while having the opposite effect in the leg.

Watenpaugh, Donald E.↗

Pharmacologic Atrial Natriuretic Peptide Reduces Human Leg Capillary Filtration

Atrial natriuretic peptide (ANP) is produced and secreted by atrial cells. We measured calf capillary filtration rate with prolonged venous-occlusion plethys-mography of supine health male subjects during pharmacologic infusion of ANP (48 pmol/kg/min for 15 min; n equals 6) and during placebo infusion (n equals 7). Results during infusions were compared to prior control measurements. ANP infusion increased plasma (ANP) from 30 plus or minus 4 to 2,568 plus or minus 595 pmol/L. Systemic hemoconcentration occurred during ANP infusion; mean hematocrit and plasma colloid osmotic pressure increased 4.6 and 11.3 percent respectively, relative to pre-infusion baseline values (p is less than 0.05). Mean calf filtration, however was significantly reduced from 0.15 to 0.08 ml/100 ml/min with ANP. Heart rate increased 20 percent with ANP infusion, wheras blood pressure was unchanged. Calf conductance (blood flow/arterial pressure) and venous compliance were unaffected by ANP infusion. Placebo infusion had no effect relative to prior baseline control measurements. Although ANP induced systemic capillary filtration, in the calf, filtration was reduced with ANP. Therefore, phamacologic ANP infusion enhances capillary filtration from the systemic circulation, perhaps at upper body or splanchic sites or both, while having the opposite effect in the leg.

Watenpaugh, Donald E.↗

Filtration Combustion in Smoldering and SHS

Smolder waves and SHS (self-propagating high-temperature synthesis) waves are both examples of filtration combustion waves propagating in porous media. Smoldering combustion is important for the study of fire safety. Smoldering itself can cause damage, its products are toxic and it can also lead to the more dangerous gas phase combustion which corresponds to faster propagation at higher temperatures. In SHS , a porous solid sample, consisting of a finely ground powder mixture of reactants, is ignited at one end. A high temperature thermal wave, having a frontal structure, then propagates through the sample converting reactants to products. The SHS technology appears to enjoy a number of advantages over the conventional technology, in which the sample is placed in a furnace and "baked" until it is "well done". The advantages include shorter synthesis times, greater economy, in that the internal energy of the reactions is employed rather than the costly external energy of the furnace, purer products, simpler equipment and no intrinsic limitation on the size of the sample to be synthesized as exists in the conventional technology. When delivery of reactants through the pores to the reaction site is an important aspect of the combustion process, it is referred to as filtration combustion. The two types of filtration combustion have a similar mathematical formulation, describing the ignition, propagation and extinction of combustion waves in porous media. The goal in each case, however, is different. In smoldering the desired goal is to prevent propagation, whereas in SHS the goal is to ensure propagation of the combustion wave, leading to the synthesis of desired products. In addition, the scales in the two areas of application differ. Smoldering generally occurs at lower temperatures and propagation velocities than in SHS nevertheless, the two applications have much in common so that what is learned fit make application can be used to advantage in the other. In porous media, melting often occurs ahead of the propagating combustion wave. In certain cases there is so much melting that the porous solid structure is destroyed, e.g., by melting and a suspension arises, consisting of a liquid bath containing solid particles and/or gas bubbles. The resulting combustion wave is referred to as a liquid flame. We have considered a number of problems involving filtration combustion. Here, we describe four such studies: (A) rapid buoyant filtration combustion waves; (B) diffusion driven combustion waves; (C) rapidly propagating liquid flames in gravitational fields; and (D) gas-phase influence on liquid flames in gravitational fields.

Matkowsky, Bernard J.↗

Graphene-Based Filtration Media for Spacecraft Potable Water Systems: An Early Investigation

Graphene-based materials have allowed fundamental advances in fields such as energy storage, electronics development, material science, optics, medicine, and water processing due to its unique two-dimensional structure, mechanical robustness, large surface, and high conductivity. However, little to no effort has been devoted to exploiting and studying these materials to develop new water technologies suited for spacecraft applications. One such application is the potential use of graphene-based materials as filtration media for reclaimed water. Therefore, studying the adsorptive performance of these new materials becomes crucial in identifying the opportunity to replace/upgrade State-of-the-Art filtration media currently used in space vehicles with water-recovery capability; especially if consumable requirements can be lessened as a result of extended filtration capacity. This early life-support-systems investigation pioneers in graphene-research by testing a number of graphene-based materials in comparative adsorption and antimicrobial experiments where contaminant removal efficiency, maximum adsorption capacity, and log reduction are probed. This preliminary investigation informs on the practicability of using graphene-based materials as filtration media and provides a discussion on the scaling-up and optimization of this prospective filtration technology for spacecraft potable water systems.

graphene↗

Effects of dilute-acid pretreatment conditions on filtration performance of corn stover hydrolyzate

In this study, the reaction conditions used during dilute-acid pretreatment of lignocellulosic biomass control the carbohydrate digestion yield and also hydrolyzate properties. Depending on the conversion route of interest, solid-liquid separation (SLS) may be required to split the hemicellulose-rich liquor from the cellulose-rich insoluble solids, and slurry properties are important for SLS. Corn stover was pretreated at different reaction conditions and the slurries were assessed for conversion yield and filtration performance. Increasing pretreatment temperature reduced the solids mean particle size and resulted in slower slurry filtration rates when vacuum filtered or pressure filtered. Corn stover pretreated at 165 °C for 10 min and with 1% H 2 SO 4 exhibited the highest xylose yield and best filtration performance with a no-wash filtration rate of 80 kg/h m 2 and cake permeability of 15 x 10 -15 .

09 BIOMASS FUELS↗

Fate of leaf litter deposits and impacts on oxygen availability in bank filtration column studies

Highlights: • Impacts of leaf inputs in bank filtration and soil aquifer treatment. • Long-term column experiments with leaf litter fragments. • Severe oxygen consumption by bio-degradation within a few millimeters. • No co-metabolic degradation of benzotriazole and carbamazepine. • Decline of carbon content relative to nitrogen and sulfur. Degradation of particulate organic carbon (POC) such as leaf litter might deplete dissolved oxygen within the upper layers of bank filtration, an efficient and robust barrier for pathogens and for various organic micro-pollutants (OMP) in water supply systems worldwide. The degradation of OMP during bank filtration depends on the redox conditions. The present study aimed at identifying the impacts and fates of different local leaves on the oxygen consumption and the possible biological degradation of indicator OMP. Oxygen concentrations initially decreased within the columns from around 8 mg/L in the influent to low concentrations indicating extensive consumption within a short travel distance. Still a substantial oxygen consumption was observed after 250 days. OMP concentrations were not significantly affected by the microbial processes. A layer of calcium carbonate crystallites was observed on the POC layer. Some leaf fragments appeared to be persistant towards degradation and the carbon content relative to nitrogen and sulfur contents decreased within 250 days. The results demonstrate that trees at bank filtration sites might have a strong long-term impact on the subsurface redox conditions.

54 ENVIRONMENTAL SCIENCES↗

Cardiovascular benefits of short-term indoor air filtration intervention in elderly living in Beijing: An extended analysis of BIAPSY study

Highlights: • Short-term air filtration can significantly reduce indoor air pollution concentrations. • Indoor air pollution exposure is positively associated with adverse cardiovascular effect. • Short-term indoor air filtration can be of some cardiovascular benefits in elderly. • Nonlinear inverse exposure-response relationships also confirmed benefits of air pollution reduction from filtration. Adverse cardiovascular effects associated with air pollution exposure have been widely demonstrated. However, inconsistent cardiovascular responses were observed from reducing indoor air pollution exposure. We aimed to assess whether short-term air filtration intervention could benefit cardiovascular health in elderly living in high pollution area.

54 ENVIRONMENTAL SCIENCES↗

Efficacy of fixed filtration for rapid kVp-switching dual energy x-ray systems

Purpose: Dose efficiency of dual kVp imaging can be improved if the two beams are filtered to remove photons in the common part of their spectra, thereby increasing spectral separation. While there are a number of advantages to rapid kVp-switching for dual energy, it may not be feasible to have two different filters for the two spectra. Therefore, the authors are interested in whether a fixed added filter can improve the dose efficiency of kVp-switching dual energy x-ray systems. Methods: The authors hypothesized that a K-edge filter would provide the energy selectivity needed to remove overlap of the spectra and hence increase the precision of material separation at constant dose. Preliminary simulations were done using calcium and water basis materials and 80 and 140 kVp x-ray spectra. Precision of the decomposition was evaluated based on the propagation of the Poisson noise through the decomposition function. Considering availability and cost, the authors chose a commercial Gd{sub 2}O{sub 2}S screen as the filter for their experimental validation. Experiments were conducted on a table-top system using a phantom with various thicknesses of acrylic and copper and 70 and 125 kVp x-ray spectra. The authors kept the phantom exposure roughly constant with and without filtration by adjusting the tube current. The filtered and unfiltered raw data of both low and high energy were decomposed into basis material and the variance of the decomposition for each thickness pair was calculated. To evaluate the filtration performance, the authors measured the ratio of material decomposition variance with and without filtration. Results: Simulation results show that the ideal filter material depends on the object composition and thickness, and ranges across the lanthanide series, with higher atomic number filters being preferred for more attenuating objects. Variance reduction increases with filter thickness, and substantial reductions (40%) can be achieved with a 2× loss in intensity. The authors’ experimental results validate the simulations, yet were overall slightly worse than expectation. For large objects, conventional (non-K-edge) beam hardening filters perform well. Conclusions: This study demonstrates the potential of fixed K-edge filtration to improve the dose efficiency and material decomposition precision for rapid kVp-switching dual energy systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ozonized biochar filtrate effects on the growth of Pseudomonas putida and cyanobacteria Synechococcus elongatus PCC 7942

Background: Biochar ozonization was previously shown to dramatically increase its cation exchange capacity, thus improving its nutrient retention capacity. The potential soil application of ozonized biochar warrants the need for a toxicity study that investigates its effects on microorganisms. Results: In the study presented here, we found that the filtrates collected from ozonized pine 400 biochar and ozonized rogue biochar did not have any inhibitory effects on the soil environmental bacteria Pseudomonas putida, even at high dissolved organic carbon (DOC) concentrations of 300 ppm. However, the growth of Synechococcus elongatus PCC 7942 was inhibited by the ozonized biochar filtrates at DOC concentrations greater than 75 ppm. Further tests showed the presence of some potential inhibitory compounds (terephthalic acid and p-toluic acid) in the filtrate of non-ozonized pine 400 biochar; these compounds were greatly reduced upon wet-ozonization of the biochar material. Nutrient detection tests also showed that dry-ozonization of rogue biochar enhanced the availability of nitrate and phosphate in its filtrate, a property that may be desirable for soil application. Conclusion: Ozonized biochar substances can support soil environmental bacterium Pseudomonas putida growth, since ozonization detoxifies the potential inhibitory aromatic molecules.

59 BASIC BIOLOGICAL SCIENCES↗