92 records · Page 3

Nuclear Safety [Vol. 34, No. 1, January-March 1993]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 An Integrated Regional Approach To Risk Management of Industrial Systems, S. Chakraborty and R. Stratton; 9 Annual Technical Meeting of the NRC Cooperative Severe Accident Research Program, E. G. Silver; ACCIDENT ANALYSIS: 13 Deterministic Severe Accident Criteria as Severe Accident Design Criteria and Policy for the New Production Reactor-Heavy Water Reactor, P. T. Rhoads; 20 Proposed Deterministic Severe Accident Criteria for the Heavy Water Reactor-New Production Reactor Containment, K. D. Bergeron, S. E. Slezak, and C. E. Leach; 33 Quasi-Static Core Liquid Level Depression and Long-Term Core Uncovery During a PWR LOCA, Y. Kukita, R. R. Schultz, H. Nakamura, and J. Katayama; 49 LIRA: An Advanced Containment System to Minimize the Accidental Radioactivity Releases, A. Turricchia; 63 Errata to “A Review of Hydrogen Production During Melt/Water Interaction in LWRs,” Vol. 33, No. 4; CONTROL AND INSTRUMENTATION: 64 The Nuplex 80+™ Advanced Control Complex from ABB Combustion Engineering, F. Ridolfo, D. Harmon, and K. Scarola; DESIGN FEATURES: 76 A Scheme for Passive Isolation of the Containment of a Reactor, A. K. Ghosh, V. V. Raj, and K. Kakodkar; 84 Utility Requirements for Safety in the Passive Advanced Light-Water Reactor, T. U. Marston, W. H. Layman, and G. Bockhold, Jr.; WASTE AND SPENT FUEL MANAGEMENT: 91 Activities Related to Waste and Spent Fuel Management, Compiled by M. D. Muhlheim and E. G. Silver; OPERATING EXPERIENCES: 103 Testing Deficiencies in Auxiliary Systems Feedwater Systems, J. D. Kueck; 110 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 113 Selected Safety-Related Events, Compiled by G. A. Murphy; 115 Operating U.S. Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver; RECENT DEVELOPMENTS: 133 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 145 Reports, Standards, and Safety Guides, D. S. Queener; 150 Proposed Rule Changes as of Sept. 30, 1992; ANNOUNCEMENTS: 75 Harvard Short Course on Risk: Science, Assessment, and Management; 102 International Conference on Reactor Physics and Reactor Computations; 102 The Fourth International Conference on Nuclear Waste Reprocessing and Waste Management [RECOD ’94]; 132 International Symposium on the Radiological Exposure of the Population of the European Community from Radioactivity in the Mediterranean Sea [MARINA-MED]; 162 International High-Level Radioactive Waste Conference ‘Technology Integration—Above and Below”; 154 The Authors; 158 Indexes to Nuclear Safety, Volume 33.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Validating a Dynamic PWR Safety and Security Model?

Nuclear power plants (NPPs) are assessed for safety and security using separate models that cannot capture how an attacker's decisions and a plant's response unfold together in real time, leaving regulators and operators without a complete picture of true plant vulnerability. Traditional probabilistic risk assessment (PRA) methods treat adversarial events as fixed initiators with predetermined outcomes, and are structurally incapable of representing the time-dependent interplay between physical security events, safety system response, and operator mitigative actions. At Idaho National Laboratory (INL), I contributed to the development and validation of Modeling and Analysis for Safety and Security using the Dynamic EMRALD Framework (MASS-DEF). Where static PRA relies on event-tree logic that cannot evolve mid-scenario, MASS-DEF couples a time-dependent dynamic PRA tool EMRALD (Event Modeling Risk Assessment using Linked Diagrams) with attack simulation software, allowing attacker behavior, plant system states, and operator actions to interact across time. My work focused on validating a general Pressurized Water Reactor (PWR) model. I traced model logic against PWR plant to identified errors in logic and confirm accuracy. I then built and tested attack scenarios against a general PWR model to verify that the model produced expected outcomes across all logical pathways. I also contributed a section to a related technical paper applying the same EMRALD platform to radiation dose modeling. Results show that MASS-DEF can quantitatively demonstrate that many plants exceed their regulatory security thresholds. This demonstrated margin provides a technically defensible basis for reducing the number of guards without compromising regulatory compliance. Physical security costs represent roughly 10% of annual operating budgets, making such reductions directly meaningful to INL's mission of sustaining existing commercial NPPs. This internship strengthened my understanding of nuclear systems, probabilistic modeling, and technical writing, and has solidified my pursuit of a career at a national laboratory.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL

Chevron Natural Gas Carbon Capture Technology Testing Project (Final Technical Report)

The objective of this project was to design, construct, commission, and operate an engineering scale post combustion carbon capture system to validate the technical maturity, operability, and scalability of Svante’s VeloxoTherm™ solid sorbent carbon capture technology under representative flue gas conditions. The project was executed at Chevron’s Kern River oil field in the San Joaquin Valley of California and evaluated carbon capture performance using slipstream flue gas from natural gas fired once through steam generators (OTSG), including indicative coal and natural gas combined cycle (NGCC) operating scenarios.

03 NATURAL GAS

Commercialization of the NLR Hydrogen Wide Area Monitor (HyWAM): Cooperative Research and Development (Final Report)

Hydrogen wide area monitoring refers to the temporal and quantitative 3-dimenasional spatial profiling of hydrogen plumes following either intentional or unintentional hydrogen releases. A hydrogen wide area monitor (HyWAM) would have applications as a research tool, for example to provide empirical data on the behavior of hydrogen dispersions following a release, which in turn can be used to validate modelling studies. Support of modeling studies and commercial applications are interrelated, since modeling can serve to guide HyWAM deployment for enhanced safety within medium to large scale hydrogen operations, such as those envisioned by H2@Scale.

08 HYDROGEN

Heat Transfer Fluids as Co‐Diluents in Localized High‐Concentration Electrolytes for High‐Rate Lithium Metal Batteries With Enhanced Safety

Localized high-concentration electrolytes (LHCEs) have been identified as promising electrolyte formulations for lithium metal batteries, due to their effective interphase formation and promotion of compact Li deposition, yet their practical implementation is often limited by reduced ion transport kinetics. In this study, two industrially established fluorinated ethers are identified for the first time in battery research as effective co-diluents as they combine a broad electrochemical stability window with a low viscosity and intrinsic non-flammability. Incorporating these components, commonly used as heat transfer fluids, yields safer, less flammable electrolyte formulations with enhanced ion mobilities. In particular, the ternary co-diluent formulation shows improved ion mobility by reducing the electrolyte's viscosity while limiting excessive ion clustering. Based on the improved electrolyte transport kinetics, lower overvoltages and higher Coulombic efficiencies at current densities ≥ 1 mA cm −2 are achieved with the ternary co-diluent blend, resulting in markedly extended cycle life in an application-oriented zero-excess pouch cell compared with the baseline system. Complementary electrochemical and ex situ analysis of harvested electrodes at moderate current densities reveals no discernible differences in interphase morphology and composition, suggesting enhanced ion mobility as the primary cause of the improved high-rate performance.

electrolyte diluent

A Python Tool for Aqueous Plutonium Nitrate Density Law Input Preprocessing in MCNP6

Here, this work develops a predictive density tool in Python, named Plutonium Nitrate Solutions (PuNS), to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer method and an empirical method were implemented into the PuNS tool to generate atom densities for use in MCNP6 material cards. These material cards are directly prepared into an MCNP6 input text file and are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, and plutonium isotope weight percentages. The PuNS tool is validated and verified against the International Criticality Safety Benchmark Evaluation Project Handbook experiments and is observed to predict densities within a root mean square error of 0.89% for the Pitzer method and 1.82% for the empirical method. These errors in density lead to up to 1569 pcm difference in MCNP6 calculated k eff for the Pitzer method and up to a 1751 pcm difference for the empirical method when compared to experimental benchmarks. Simultaneous work is also being performed at Los Alamos National Laboratory and the University of New Mexico to create a similar tool for plutonium chloride solutions, named Plutonium Chloride Solution, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also facilitate an improved understanding of solution systems and a potential relaxation in the conservatism of current aqueous plutonium processing criticality safety limits.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA

Influence of Seawater Salts on Magnesium Oxide Hydration: Implications for Carbonation

The effects of individual component salts on MgO hydration and subsequent carbonation have not been systematically investigated despite the increase in utilization of seawater and other brines in the production of MgO-containing next-generation cements, fire retardants, and sorbents for CO2. Here, we present a study of MgO hydration in the presence of individual saltwater cations at a range of concentrations, as well as binary mixtures at seawater concentrations, and subsequent carbonation. We observed that the presence of the cations increased MgO dissolution rates and that the subsequent carbonation extent of the hydrated material remained constant or even increased. Since the presence of these salts during hydration does not show negative effects on subsequent carbonation in our experimental study, the application of seawater and other brines containing high concentrations of these salts to hydrate MgO in industrial processes is likely feasible.

Evans, Barbara [ORNL] (ORCID:0000000225742567)

Criteria for Retention of 3013 S1 Containers Based on Relative Risk and Expert Judgment

An evaluation was performed to assess the suitability of thirty-three 3013 containers proposed for retention. These containers have moisture levels greater than 0.08 wt.% – the S1 population. The remainder of the S1 population stored at SRS will be down blended and disposed of by the end of 2028. Based on field surveillance and shelf-life data available to date as well as informed technical judgment, no container is currently expected to fail in its 50-year storage period. However, corrosion risk varies across the S1 population. Relative risks were evaluated using predicted Consensus Scores and their 95% Upper Prediction Limits (UPLs). The predicted values are based on a statistical model of Consensus Score as a function of moisture, chloride, and whether the packaged material was electrorefining scrap packaged at Hanford. Consensus Score has been shown to be a useful indicator of corrosion potential, and the UPL captures uncertainty in the model predictions, providing a conservative indicator of corrosion potential. Using UPLs to determine relative risks, together with expert review, three containers were identified as not suitable for retention, and the remainder were determined to be suitable.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Aerosol Can Fireball Tests: Commodity Hazards in the Transportation Environment Phase 1 Report

This report describes a series of tests performed at Sandia’s burn site to better understand the behavior of aerosol commodities and their hazards in the transportation environment. This comes on the tail of a prior study on the use cases and historical hazards associated with aerosol commodities in the shipping environment (Cambridge Systematics Incorporated, CSI, 2020). It is also mindful of the National Fire Protection Agency NFPA30B standard for safe warehousing of aerosol commodities. Warehousing is different from transit because warehousing typically involves active suppression and mitigation measures not practical or relevant to the shipping environment. Transit also typically involves tighter packing and smaller enclosure spaces. The transportation hazard space has not been heavily studied in prior testing specifically aimed towards the ground, rail, and nautical shipping environments.

54 ENVIRONMENTAL SCIENCES

Weak, shallow, dry convection over Angola increases offshore stratocumulus cloud droplet number concentrations

Boundary-layer cloud interactions involving shortwave-absorbing aerosols remain one of the least understood aerosol influences on climate. Here, we find the highest stratocumulus cloud droplet number concentrations over the southeast Atlantic occur when agricultural fires coincide with synoptically-weakened surface warming over Angola, occurring June-early August. Dry convection fills a shallow continental boundary layer with smoke, and a nighttime (local solar time 2-9) land breeze transports the aerosol into the marine boundary layer. Offshore aerosol transport is strengthened by low-level easterlies from a continental pressure high southeast of Angola. Simultaneously, the South Atlantic subtropical high is weaker, allowing extensive dispersal of aerosol offshore into the boundary layer, obscuring cloud brightening from shipping. Meteorological co-variation at synoptic scales compensates for cloud brightening by the smoke. Outgoing shortwave radiation increases by 15–20% of the monthly mean in June and July when offshore droplet numbers are less but the stratocumulus deck is more developed.

54 ENVIRONMENTAL SCIENCES

Programmable Digital Devices used in Advanced Reactors

This paper introduces the concepts of common cause failure, diversity, and defense-in-depth used by the nuclear industry to analyze resilience in reactors. A survey of publicly traded and private companies building advanced reactors and their licensing status is presented. Safety and non-safety systems found in the NuScale Power design are summarized and the likely hardware and software categories used by those systems are enumerated. The importance of industry partners is highlighted. This paper also identifies an alternate path forward without industry partners to advance the knowledge needed to use artificial intelligence to analyze HBOMs and SBOMs to better understand reactor resiliency.

cybersecurity

Best Practices for Resilience Hub Development and Management

The Carbon League and its community partners in East St. Louis, Illinois, have identified five facilities to serve as resilience hubs. These hubs are intended to support the local community through a range of services and resources during blue-sky (everyday), gray-sky (pre-event), and black-sky (emergency) conditions. Transforming these facilities into fully functional resilience hubs requires a broad operational improvement and programmatic planning roadmap. This memo outlines best practices to guide the development of these resilience hubs in East St. Louis, including recommendations for infrastructure services; safety and physical protection; community services; operational protocols; and a phased implementation strategy aligned with realistic funding and capacity constraints. Infrastructure recommendations include strengthening electric power, communications, water, sanitation, and transportation/logistics capabilities, all of which are essential for hubs that may serve as cooling and warming centers, distribution points, and information hubs during emergencies. Safety recommendations focus on accessibility, emergency action planning, indoor air quality, and secure storage of critical equipment. A phased roadmap provides guidance from immediate, low-cost readiness actions to long-term optimization and community integration. Performance metrics and maintenance protocols ensure continuous improvement and operational readiness. This guidance draws on best practices that can be used to support the development of resilient, community-centered hubs capable of enhancing public safety, health, and well-being during everyday operations and emergencies alike.

99 GENERAL AND MISCELLANEOUS

UL 1741SC Conformance Development, Evaluation, and Proposal [Slides]

V2G AC is a type of grid interconnection by mobile battery that transforms an EV into a DER with the potential to stabilize the grid and lower costs for electricity. UL 1741SC is a critical new standard to enable grid interconnection of V2G AC-capable vehicles, by defining requirements for V2G AC-intended EVSEs as a gatekeeper between the grid and the EV to support grid safety, such as through redundant voltage trip (namely oversight). EVSE manufacturers need a clear set of conformance test cases and criteria by which to evaluate their equipment and confirm the compliance with UL 1741SC, so that the EVSEs performs as intended for the grid safety. Hence, NLR identified necessary conformance tests and performed the tests identified to understand the maturity.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Revealing Hidden Quinones Through Diagnostic MS² Fragmentation of Peptide–Quinone Adducts

Quinones are redox-active components of natural organic matter that mediate electron transfer and influence biogeochemical processes, but many quinones in pyrogenic organic matter (PyOM) remain unresolved because they ionize poorly by mass spectrometry. Here, we present a peptide-tagging approach to improve detection of cysteine-reactive electrophiles in PyOM, with quinones expected to be a dominant subset based on reaction chemistry and selectivity experiments. A cysteine-containing peptide was used to form Michael-addition adducts, enhancing electrospray ionization and enabling untargeted screening by high-performance liquid chromatography-high-resolution tandem mass spectrometry. The method was benchmarked with five quinone standards and applied to extracts from charred plant material as a discovery-level screen for cysteine-reactive targets. We identified 98 quinone-candidate adducts (mean neutral mass ~603 Da), of which more than 70% were not detectable in native MS1 data. Among formula-assigned features, hidden quinone candidates had median (O+N)/C of 0.391 and normalized oxidation state of carbon of -0.281, consistent with relatively low polarity and low oxidation state. These results reveal a previously inaccessible pool of hidden redox-active compounds in PyOM and provide a framework for prioritizing quinone-like electrophiles for confirmation and incorporation into models of fire-driven biogeochemical cycling.

LC-MS/MS

Advanced LiFSI-LiPF6 Electrolyte for Wide-Temperature and Thermally Stable Lithium-Ion Batteries

A new optimized LiFSI–LiPF6 dual-salt controlled-solvation electrolyte (E-DS) is demonstrated to enable practical graphite||LiNi0.8Mn0.1Co0.1O2 cells (˜4.0 mAh cm?²) to achieve exceptional performance and safety under extreme conditions. By optimizing anion coordination with the smaller, more dissociating FSI? anion, the E-DS forms ultrathin, dense, and inorganic-rich electrode/electrolyte interphases that dramatically suppress solvent decomposition, transition-metal dissolution, and surface reconstruction compared to the conventional LiPF6/carbonate electrolyte. Consequently, E-DS cells deliver >78% capacity retention after 300 cycles at 60 °C, retain fast discharging capacity at 30 °C, and operate effectively at -20 °C. Most strikingly, fully charged full cells with E-DS, even under overcharging to 4.8 V, show a lower heat evolution in stable formulations — transforming a traditionally unstable high-voltage/high-temperature configuration into an intrinsically safe state. This work establishes a new benchmark for carbonate-containing electrolytes, simultaneously achieving high energy density, fast-discharging capability, wide-temperature operation (-20 to 60 °C), and outstanding thermal safety in nickel-rich lithium-ion batteries.

electrode/electrolyte interphase

A stable high-humidity bubbler design to supply steam for solid oxide electrolysis cells

A stable steam supply is required for the operation of solid oxide electrolysis cells. Heated water bubblers are the most common method due to the simplicity and inherent safety of the method, however, several design challenges hinder effective implementation. Here, a stable and validated bubbler design is presented, capable of achieving very high steam concentrations, relatively high flow rates, and continuous operation. A piping and instrumentation diagram and bill of materials are provided to enable easy duplication. Critical design parameters are discussed, including safety considerations and materials requirements, which are applicable to any bubbler design. The practical implementation of bubblers is also presented, including methods to prevent condensation instability and reduce backpressure to achieve a stable steam supply. The 3″ x 6″ (7.6 cm × 15.2 cm) bubbler achieves up to 98% steam balance hydrogen at 200 sccm and up to 1 slpm at 96% steam.

08 - HYDROGEN

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN