At least 55 records · Page 3

Submicrosecond characteristics of lightning return-stroke currents

The authors describe the experimental results obtained during 1987 and 1988 triggered-lightning experiments in Florida. Seventy-four simultaneous submicrosecond time-resolved measurements of triggered return-stroke current (I) and current derivative (dI/dt) were made in Florida in 1987 and 1988. Peak currents ranged from about 5 to 76 kA, peak dI/dt amplitude from 13 to 411 kA/microsec and rise time from 90 to 1000 ns. The mean peak dI/dt values of 110 kA/microsec were 2-3 times higher than data from instrumented towers and peak I and dI/dt appear to be positively correlated. These data confirm previous experiments and conclusions supported by forty measurements. They are important in order to define, for example, standards for lightning protection. Present standards give a dI/dt maximum of 140 kA/microsec.

Leteinturier, Christiane↗

Design Optimization of Innovative High-Level Waste Pipeline Unplugging Technologies - 13341

Florida International University (FIU) is currently working on the development and optimization of two innovative pipeline unplugging methods: the asynchronous pulsing system (APS) and the peristaltic crawler system (PCS). Experiments were conducted on the APS to determine how air in the pipeline influences the system's performance as well as determine the effectiveness of air mitigation techniques in a pipeline. The results obtained during the experimental phase of the project, including data from pipeline pressure pulse tests along with air bubble compression tests are presented. Single-cycle pulse amplification caused by a fast-acting cylinder piston pump in 21.8, 30.5, and 43.6 m pipelines were evaluated. Experiments were conducted on fully flooded pipelines as well as pipelines that contained various amounts of air to evaluate the system's performance when air is present in the pipeline. Also presented are details of the improvements implemented to the third generation crawler system (PCS). The improvements include the redesign of the rims of the unit to accommodate a camera system that provides visual feedback of the conditions inside the pipeline. Visual feedback allows the crawler to be used as a pipeline unplugging and inspection tool. Tests conducted previously demonstrated a significant reduction of the crawler speed with increasing length of tether. Current improvements include the positioning of a pneumatic valve manifold system that is located in close proximity to the crawler, rendering tether length independent of crawler speed. Additional improvements to increase the crawler's speed were also investigated and presented. Descriptions of the test beds, which were designed to emulate possible scenarios present on the Department of Energy (DOE) pipelines, are presented. Finally, conclusions and recommendations for the systems are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prediction of Potential-Induced Degradation Rate of Thin-Film Modules in the Field Based on Coulombs Transferred

We validated the use of coulombs transferred between the active cell circuit and ground as an index for quantitatively predicting degradation rate in the field for two thin-film module types undergoing potential-induced degradation (PID). The dependence was determined by comparing the degradation rate and leakage current in the field (Cocoa, Florida) to accelerated tests (85 degrees C, 85% relative humidity), both with the application of -1,000 V bias to the cell circuit. The two module types, which degraded about 4% and 11% in power after application of 96 h of bias in chamber, degraded 5% in the field by PID within 200 days and 6 days, respectively. The signatures of PID in the thin-film modules by electroluminescence, photoluminescence, and thermography are shown so that PID in fielded thin-film modules can be identified.

14 SOLAR ENERGY↗

Electric field intensity of the lightning return stroke.

From an examination of about 1000 electric field wave forms produced by lightning return strokes in 16 storms at distances between 20 and 100 km from an observation site at the Kennedy Space Center, Florida, a typical return stroke current wave form is derived. For this current wave form, the electric field intensity at distances between 0.5 and 100 km is computed for three values of return stroke velocity. The resultant curves for close lightning are compared with measured field wave forms. The transmission line return stroke model is used in all calculations since, as discussed, the Bruce-Golde model cannot account for the observed electric field characteristics.

Uman, M. A.↗

Development of a Testbed for Pipeline Flushing - 19409

Pipelines which carry radioactive waste within the DOE complex should be properly flushed, particularly in the cases where stationary or moving beds of solid sediment occur, or lines are prone to hydrogen gas buildup. Present guidelines establish a minimum for the amount of water used for post-transfer flushing operations to achieve satisfactory cleaning of pipelines. However, further studies are needed to limit the amount of water used for flushing operations, thus minimizing the consequent downstream waste. These efforts are significantly helpful to DOE waste remediation sites by preserving tank storage, preventing additional waste processing, and minimizing dilution and changes in waste chemistry. An experimental pipe loop designed for study of non-Newtonian slurry flushing is currently being developed at the Florida International University (FIU). The testbed is designed to investigate parameters that effect the efficiency of flushing operations. The objective is to find flush velocity values/modes which lead to satisfactory cleaning of transport lines with a minimum amount of water usage. The developed methodologies will be streamlined according to the demands from both Hanford and Savannah River sites. A test matrix containing parameters such as pipeline length, flow rate, and simulant composition (solid concentration, rheology, particle size and density) has been developed. In the initial phase of testing, material composition and loop length will be fixed to a mixture of 17 wt% kaolin in water (to attain density, viscosity, and yield stress in the applicable range to operations at Savannah River and Hanford sites) and 165 feet, respectively. This matrix provides a parametric study on the flush velocity. Prescribed velocities in this test matrix comply with the maximum and minimum recommended flush velocity values by the flushing guidelines for Hanford waste (RPP-RPT-59600, Rev. 0, SRNL-STI-2015-00014, TFC-ENG-STD-26, REV C-1). Efforts will focus on creating repeatable sediment beds inside the pipeline in both fully-flooded and gravity-drained systems. Bed characterization (i.e., measurement of sediment height, solids concentration, and rheology) will be conducted to ensure consistency of initial conditions between tests. A combination of Pulse-Echo technique, Coriolis meter, and optical inspections will be used to accomplish initial bed characterization (ensuring consistency between tests), control/monitor density variations (initial bed creation, flush velocity control, and post-flush evaluations), and serve as reference (validation of PulseEcho and pipe surface cleanness evaluation), respectively. This paper will present the details of the development of the test loop and the test matrix. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adaptive Individual Blade Pitch Control of an Ocean Current Turbine for Load Reduction

A Direct Adaptive Disturbance Rejection (DADR) control algorithm is evaluated using a numer-ical simulation of an Ocean Current Turbine (OCT) for its ability to minimize the cyclic loadings on the rotor blades caused by current shear. This control algorithm reduces these cyclic loadings by individually altering the pitch angles of the rotor blades as a function of rotor rotation angle. The OCT numerical model represents a system with a single 3 bladed 20 meter diameter rotor operated in the Gulf Stream off the coast of Ft. Lauderdale, Florida for mean and maximum measured current shear values of 0.004 and 0.03 (m/s)/m. The results indicate that the adaptive controller reduced the amplitude of the cyclic axial blade loads on a rigidly mounted and moored turbine by 91.18% and 92.3% in the mean current shear and by 94.12% and 81.88% in maximum current shear demonstrating the value of this controls approach.

adaptive control↗

Examining the Impacts of High-Resolution Land Surface Initialization on Model Predictions of Convection in the Southeastern U.S.

One of the most challenging weather forecast problems in the southeastern U.S. is daily summertime pulse convection. During the summer, atmospheric flow and forcing are generally weak in this region; thus, convection typically initiates in response to local forcing along sea/lake breezes, and other discontinuities often related to horizontal gradients in surface heating rates. Numerical simulations of pulse convection usually have low skill, even in local predictions at high resolution, due to the inherent chaotic nature of these precipitation systems. Forecast errors can arise from assumptions within physics parameterizations, model resolution limitations, as well as uncertainties in both the initial state of the atmosphere and land surface variables such as soil moisture and temperature. For this study, it is hypothesized that high-resolution, consistent representations of surface properties such as soil moisture and temperature, ground fluxes, and vegetation are necessary to better simulate the interactions between the land surface and atmosphere, and ultimately improve predictions of local circulations and summertime pulse convection. The NASA Short-term Prediction Research and Transition (SPORT) Center has been conducting studies to examine the impacts of high-resolution land surface initialization data generated by offline simulations of the NASA Land Informatiot~ System (LIS) on subsequent numerical forecasts using the Weather Research and Forecasting (WRF) model (Case et al. 2008, to appear in the Journal of Hydrometeorology). Case et al. presents improvements to simulated sea breezes and surface verification statistics over Florida by initializing WRF with land surface variables from an offline LIS spin-up run, conducted on the exact WRF domain and resolution. The current project extends the previous work over Florida, focusing on selected case studies of typical pulse convection over the southeastern U.S., with an emphasis on improving local short-term WRF simulations over the Mobile, AL and Miami, FL NWS county warning areas. Future efforts may involve examining the impacts of assimilating remotely-sensed soil moisture data, and/or introducing weekly greenness vegetation fraction composites (as opposed to monthly climatologies) into ol'fline NASA LIS runs. Based on positive impacts, the offline LIS runs could be transitioned into an operational mode, providing land surface initialization data to NWS forecast offices in real time.

Case, Jonathan L.↗

Spaceport Florida Authority

The topics are covered in viewgraph form and include the following: objectives; current initiatives; the Space Research Initiative Program; the Cape San Blas Launch Program; and Spaceport Florida Laboratories.

Source record↗

Regional Analysis for an Economically and Environmentally Viable Transition to Heavy-Duty Vehicles with Alternative Powertrains

The transportation sector is responsible for a significant portion of greenhouse gas emissions. Within the sector, truck freight is responsible for a third of the associated emissions. Alternative powertrains are seen as a viable approach to significantly reduce these emissions. Prior to making a large-scale transition, it is important to consider the following questions: will the power grid support a transition to alternative powertrains?; will the transition truly reduce carbon emissions?; and will the transition impose an unnecessary economic burden on companies within the industry? The answer to these questions, however, can vary by geography, maturity/capacity of the energy distribution network or predicted vehicle load. We focus on the latter two questions, investigating the variation in estimated total cost of ownership and carbon emissions across the United States at the zip code level for both heavy-duty battery electric vehicles and heavy-duty fuel cell electric vehicles. As a benchmark, we compare estimated emissions and costs of alternative powertrain vehicles to that of conventional heavy-duty vehicles powered by diesel internal combustion engines. This work highlights areas with electric grids primed for a transition to alternative powertrain vehicles, such as the Pacific Northwest, and areas that require further infrastructure investment in renewables, such as many of the Mountain states, Missouri, and Florida. Additionally, this work illustrates the current advantages in carbon emissions of battery electric vehicles compared to fuel-cell electric vehicles, while providing insights into required regional investments for narrowing the gap.

Goulet, Nate [ORNL] (ORCID:0000000237314965)↗

A Measurement-Based Analysis of the Hydrokinetic Energy in the Gulf Stream

This study uses ocean current measurements made off the East Coast of the United States of America to evaluate the ocean current-based electricity production potential in the Gulf Stream. Drifter data from the World Ocean Circulation Experiment (WOCE) are used to map the energy density from South Florida to North Carolina, showing that the most energy dense areas exist off the east coast of Central Florida. Bottom- and vessel-mounted Acoustic Doppler Current Profiler (ADCP) measurements are used to conduct a more detailed study near 26°N and 27°N, respectively. Furthermore, these results quantify the energy profiles in these regions, suggesting that 54% more energy dense currents are available at 27°N than at 26°N.

16 TIDAL AND WAVE POWER↗

Evidence of multiscale supercurrents in K-doped BaFe 2 As 2

K-doped BaAs 2 Fe 2 (K-Ba122) superconductor is a promising material for applications. However, it has been found challenging to achieve high critical current density (J c ) in untextured bulk sample. In this paper we investigated bulk samples prepared by varying the milling energy density, which affects the grain and grain boundary microstructures, and we investigated their magnetic performance to better understand what causes their different J c . We found that in our samples, which all have small grain size, T c does not appear directly correlated to J c . Moreover, AC susceptibility reveals in at least one case obvious signs of multiscale supercurrents, not caused by granularity but that directly influence the overall J c performance. Considering the microstructural features and the magnetization response we ascribed the J c differences to lack of connectivity on a larger scale due to nano-cracks at some grain boundaries, which subdivided the samples into macroscopic regions and inevitably limited the overall performance. We discuss possible routes to overcome those extrinsic current-blocking defects.

AC susceptibility↗

Advanced Multi-Product Coal Utilization By-Product Processing Plant

The overall objective of this project is to design, construct, and operate an ash beneficiation facility that will generate several products from coal combustion ash stored in a utility ash pond. The site selected is LG&E's Ghent Station located in Carroll County, Kentucky. The specific site under consideration is the lower ash pond at Ghent, a closed landfill encompassing over 100 acres. Coring activities revealed that the pond contains over 7 million tons of ash, including over 1.5 million tons of coarse carbon and 1.8 million tons of fine (<10 {micro}m) glassy pozzolanic material. These potential products are primarily concentrated in the lower end of the pond adjacent to the outlet. A representative bulk sample was excavated for conducting laboratory-scale process testing while a composite 150 ton sample was also excavated for demonstration-scale testing at the Ghent site. A mobile demonstration plant with a design feed rate of 2.5 tph was constructed and hauled to the Ghent site to evaluate unit processes (i.e. primary classification, froth flotation, spiral concentration, secondary classification, etc.) on a continuous basis to determine appropriate scale-up data. Unit processes were configured into four different flowsheets and operated at a feed rate of 2.5 tph to verify continuous operating performance and generate bulk (1 to 2 tons) products for product testing. Cementitious products were evaluated for performance in mortar and concrete as well as cement manufacture process addition. All relevant data from the four flowsheets was compiled to compare product yields and quality while preliminary flowsheet designs were generated to determine throughputs, equipment size specifications and capital cost summaries. A detailed market study was completed to evaluate the potential markets for cementitious products. Results of the study revealed that the Ghent local fly ash market is currently oversupplied by more than 500,000 tpy and distant markets (i.e. Florida) are oversupplied as well. While the total US demand for ultrafine pozzolan is currently equal to demand, there is no reason to expect a significant increase in demand. Despite the technical merits identified in the pilot plant work with regard to beneficiating the entire pond ash stream, market developments in the Ohio River Valley area during 2006-2007 were not conducive to demonstrating the project at the scale proposed in the Cooperative Agreement. As a result, Cemex withdrew from the project in 2006 citing unfavorable local market conditions in the foreseeable future at the demonstration site. During the Budget Period 1 extensions provided by the DOE, CAER has contacted several other companies, including cement producers and ash marketing concerns for private cost share. Based on the prevailing demand-supply situation, these companies had expressed interest only in limited product lines, rather than the entire ash beneficiation product stream. Although CAER had generated interest in the technology, a financial commitment to proceed to Budget Period 2 could not be obtained from private companies. Furthermore, the prospects of any decisions being reached within a reasonable time frame were dim. Thus, CAER concurred with the DOE to conclude the project at the end of Budget Period 1, March 31, 2007. The activities presented in this report were carried out during the Cooperative Agreement period 08 November 2004 through 31 March 2007.

01 COAL, LIGNITE, AND PEAT↗

Existing Whole-House Solutions Case Study: Applying Best Practices to Florida Local Government Retrofit Programs - Central Florida

In some communities, local government and non-profit entities have funds to purchase and renovate distressed, foreclosed homes for resale in the affordable housing market. Numerous opportunities to improve whole house energy efficiency are inherent in these comprehensive renovations. BA-PIRC worked together in a multiyear field study making recommendations in individual homes, meanwhile compiling improvement costs, projected energy savings, practical challenges, and labor force factors surrounding common energy-related renovation measures. The field study, Phase 1 of this research, resulted in a set of best practices appropriate to the current labor pool and market conditions in central Florida to achieve projected annual energy savings of 15%-30% and higher. This case study describes Phase 2 of the work where researchers worked with a local government partner to implement and refine the "current best practices". A simulation study was conducted to characterize savings potential under three sets of conditions representing varying replacement needs for energy-related equipment and envelope components. The three scenarios apply readily to the general remodeling industry as for renovation of foreclosed homes for the affordable housing market. The new local government partner, the City of Melbourne, implemented the best practices in a community-scale renovation program that included ten homes in 2012.

30% savings↗

Applying Best Practices to Florida Local Government Retrofit Programs, Central Florida (Fact Sheet)

In some communities, local government and non-profit entities have funds to purchase and renovate distressed, foreclosed homes for resale in the affordable housing market. Numerous opportunities to improve whole house energy efficiency are inherent in these comprehensive renovations. BA-PIRC worked together in a multi-year field study making recommendations in individual homes, meanwhile compiling improvement costs, projected energy savings, practical challenges, and labor force factors surrounding common energy-related renovation measures. The field study, Phase 1 of this research, resulted in a set of best practices appropriate to the current labor pool and market conditions in central Florida to achieve projected annual energy savings of 15-30% and higher. This report describes Phase 2 of the work where researchers worked with a local government partner to implement and refine the "current best practices". A simulation study was conducted to characterize savings potential under three sets of conditions representing varying replacement needs for energy-related equipment and envelope components. The three scenarios apply readily to the general remodeling industry as for renovation of foreclosed homes for the affordable housing market. Our new local government partner, the City of Melbourne, implemented the best practices in a community-scale renovation program that included ten homes in 2012.

30% SAVINGS↗

Applying Best Practices to Florida Local Government Retrofit Programs

In some communities, local government and non-profit entities have funds to purchase and renovate distressed, foreclosed homes for resale in the affordable housing market. Numerous opportunities to improve whole house energy efficiency are inherent in these comprehensive renovations. BA-PIRC worked together in a multiyear field study making recommendations in individual homes, meanwhile compiling improvement costs, projected energy savings, practical challenges, and labor force factors surrounding common energy-related renovation measures. The field study, Phase 1 of this research, resulted in a set of best practices appropriate to the current labor pool and market conditions in central Florida to achieve projected annual energy savings of 15%-30% and higher. This report describes Phase 2 of the work where researchers worked with a local government partner to implement and refine the "current best practices". A simulation study was conducted to characterize savings potential under three sets of conditions representing varying replacement needs for energy-related equipment and envelope components. The three scenarios apply readily to the general remodeling industry as for renovation of foreclosed homes for the affordable housing market. The new local government partner, the City of Melbourne, implemented the best practices in a community-scale renovation program that included ten homes in 2012.

30% savings↗

Applying Best Practices to Florida Local Government Retrofit Programs

In some communities, local government and non-profit entities have funds to purchase and renovate distressed, foreclosed homes for resale in the affordable housing market. Numerous opportunities to improve whole house energy efficiency are inherent in these comprehensive renovations. BA-PIRC worked together in a multi-year field study making recommendations in individual homes, meanwhile compiling improvement costs, projected energy savings, practical challenges, and labor force factors surrounding common energy-related renovation measures. The field study, Phase 1 of this research, resulted in a set of best practices appropriate to the current labor pool and market conditions in central Florida to achieve projected annual energy savings of 15-30% and higher. This report describes Phase 2 of the work where researchers worked with a local government partner to implement and refine the 'current best practices.' A simulation study was conducted to characterize savings potential under three sets of conditions representing varying replacement needs for energy-related equipment and envelope components. The three scenarios apply readily to the general remodeling industry as for renovation of foreclosed homes for the affordable housing market. Our new local government partner, the City of Melbourne, implemented the best practices in a community-scale renovation program that included ten homes in 2012.

30% SAVINGS↗

A review of falconry as a bird control technique with recommendations for use at the Shuttle Landing Facility, John F. Kennedy Space Center, Florida, USA

Falconry has been proposed as a method of reducing the bird/aircraftstrike hazard, in addition to current bird control techniques, at the Shuttle Landing Facility (SLF), John F. Kennedy Space Center (KSC), Florida, U.S. Bird control programs using falconry have been employed at a number of military and commercial airfields in the U.S., Canada, and Europe. Most falconry programs have been discontinued. In most situations, falconry did not prove cost effective when compared to alternative bird control techniques. Available literature and documents, as well as several raptor specialists and military personnel, suggest that falconry may be useful only against certain problem species and when other bird control methods have been proven inadequate. Because many of the most commonly used falcons are protected species, acquisition of falcons will complicate their use in bird control programs. Many avian species found at the SLF are federally and state protected or of conservation concern, therefore, environmental impacts may also result from the use of falcons.

Larson, Vickie L.↗

An Experiment to Evaluate Skylab Earth Resources Sensors for Detection of the Gulf Stream

The author has identified the following significant results. An experiment to evaluate the Skylab earth resources package for observing ocean currents was performed in the Straits of Florida in January 1974. Data from the S190 photographic facility, S191 spectroradiometer and S192 multispectral scanner, were compared with surface observations. The anticyclonic edge of the Gulf Stream could be identified in the Skylab S190A and B photographs, but the cyclonic edge was obscured by clouds. The aircraft photographs were judged not useful for spectral analysis because vignetting caused the blue/green ratios to be dependent on the position in the photograph. The spectral measurement technique could not identify the anticyclonic front, but mass of Florida Bay water which was in the process of flowing into the Straits could be identified and classified. Monte Carlo simulations of the visible spectrum showed that the aerosol concentration could be estimated and a correction technique was devised.

Maul, G. A.↗