Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow condensation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Numerical Investigation of Enhanced Dehumidification Processes By Using Dielectrophoresis Principles in Moist Airflows

Dispersed particle-laden flows are encountered in many building and industrial applications, such as flow in a fluidized bed, hydrocarbon transportation in pipelines, and the fouling of air-cooled heat exchangers (Kuruneru et al., 2016; Ray et al., 2019; Wang et al., 2019). Computational fluid dynamic (CFD) models have been developed in recent years to depict particle-fluid and particle-particle interactions in laminar or turbulent flows with increasing accuracy and stability. One particular particle-laden system of interest for moisture control is electrically-enhanced condensation in air and water droplet flows. Electrically-enhanced condensation consists of the use of highly charged water droplets injected in the moist air. The droplets become electric seeds that attract polar water vapor molecules to their surfaces and promote condensation. The nucleation and growth of the charged droplets deplete the vapor phase near a droplet, which is compensated for by the dielectrophoresis flow and diffusion. Dielectrophoresis flow involves surrounding vapor at a distance of about 10 to 100 nm for droplets charged by an electrospray compared to ~2 nm for a single electron charge in a droplet. As the vapor molecules collapse on the surface of the droplets, their initial electrical charge decreases with time due to the neutralization of the ions. While the physics of this phenomena is well known, engineering models for predicting the condensation rates are not available. This work computationally investigates dehumidification of moist airflow in a converging rectangular duct. The objective is to develop an engineering model that predicts water vapor condensation by employing dielectrophoresis principles. We construct a Computational Fluid Dynamics (CFD) model of the duct with electrically-enhanced condensation. The model is implemented in the open-source software OpenFOAM. We utilize the Multi-Phase Particle-In-Cell (MP-PIC) method coupled with a Population Balance Equation (PBE) approach to simulate the particle-laden system. This methodology is an Eulerian-Lagrangian approach used to simulate the droplets' behavior in the humid air. The MP-PIC approach (Andrews and O'Rourke, 1996) mitigates the computational cost by parceling several fundamental particles with similar properties (such as types, sizes, and temperature) into one computational particle. Thus, the billions of particles can be substituted by millions of computational particles without significant loss of information. The PBE was considered with the Lagrangian frame to combine the particle distribution function used in MP-PIC (Kim et al., 2020). This approach preserves mass and energy conservation between the phases in the Eulerian and Lagrangian structures. The PBE in this procedure was directly linked to the discrete parcels, making the simulation of the particle distribution computationally efficient and robust. The MP-PIC-PBE approach used in the present work was applied to the dehumidification of air. Water droplets were injected in the air stream and forced to grow according to experimentally derived correlation. The experiments were conducted on a converging duct with the same geometry and boundary conditions used to build the CFD model. This approach enabled us to approximate the effect of dielectrophoresis phenomena on the droplet and air interface. This presentation will discuss the details of the new CFD model built for the duct, the implementation of the model in OpenFOAM CFD programming language, and the experimental validation of the newly developed model. The results revealed a moderate yet measurable increase in droplet diameter due to water vapor condensation at the vapor-liquid interface of the electrically charged droplets' surface. The seed water droplet particles grew in size by capturing the water vapor in the surrounding air. The OpenFOAM model predicted reductions of humidity in the air from 5 to 10 percent.

Yel Mahi, Maliha↗

Lignin Extraction and Condensation as a Function of Temperature, Residence Time, and Solvent System in Flow-through Reactors

Solvolytic extraction of lignin from biomass is a critical step in lignin-first biorefining, including the reductive catalytic fractionation (RCF) process. Key to optimal RCF processing is the ability to rapidly extract lignin from biomass at high delignification extents and transfer the lignin molecules to a catalyst surface in a time frame that minimizes lignin condensation reactions. Here, we use a flow-through reactor to study the effects of temperature (175–250 °C), residence time (9 to 36 min), and solvent composition (methanol and methanol–water) on lignin extraction and condensation. We evaluated three metrics at each condition: total delignification, delignification rate, and extent of condensation, the latter measured by a decrease in monomer yield for batch hydrogenolysis reactions of solvolysis liquor compared to batch RCF reactions. We observe that delignification is predominantly determined by temperature, while residence time dictates the lignin condensation extent. Moreover, the extent of both extraction and condensation increased in the methanol–water solvent system compared to that in the methanol system. Lignin extracted in methanol is stable up to 18-min residence times at or below 225 °C, while a majority of the lignin extracted in methanol–water is condensed with a 9-min residence time at 200 °C. These results can inform reactor designs and solvent selection for lignin-first biorefining processes that aim to physically separate the biomass and catalyst.

biorefining↗

Numerical Analysis of Water Harvesting from Saturated Vapor with the Electrospray Water Droplet Injection in The Solar-Driven Desalination Applications

Solar-driven seawater desalination systems provide freshwater through environmentally friendly and carbon-neutral processes. Air humidification and dehumidification desalination (HDD) systems extract water directly from moist air. This paper focuses on a new solar-driven seawater desalination system that shares some common traits with HDD systems but in which the air is eliminated from the process. Seawater is vaporized by solar thermal radiation in high-performance solar panels. Water vapor flows to a new electro-condensation chamber and passes through a series of electrosprays, which inject small nuclei of freshwater droplets into the vapor clouds. Here, due to dielectrophoresis and electrohydrodynamic flows, the vapor molecules are captured by the charged droplets, and vapor is condensed at the droplet surface. The water vapor condensation was modeled by using the multiphase flow numerical model. The CFD model, which was also experimentally validated, used SprayFoam solver modules available in the Open FOAM® CFD open-source software. In preliminary results, 802 grams/(hr-m2) (grams per hour per unit area) of water was harvested directly from moist air at 24C and 90% relative humidity. The simulation results indicated that freshwater productivity could increase up to 4,000 grams/(hr-m2) for fully saturated air conditions. This represents about 5 times the water productivity rate of current conventional HDD systems today. In addition, energy consumption could be reduced by 80 percent compared to conventional HDD systems.

Electrospray, electro-condensation, solar, droplet↗

Validation of RELAP-7 for Forced Convective and Natural Circulation Reactor Flows

New reactor designs such as small modular reactors and newly proposed passive safety systems rely on natural circulation two-phase flow cooling of the reactor core under accident conditions. Without a pump to drive the flow, the circulation rate is a strong function of void fraction. Under these conditions where the flow rate, pressure drop, and heat transfer are all closely coupled through the mixture density, the accurate prediction of void fraction is pivotal. Furthermore, while these passive systems boast a more reliable cooling option, the sensitivity of the system to two-phase flow instabilities is more likely than in forced convective cooling and can result in dangerous density wave or flow excursion conditions. Improvement of one-dimensional system codes and further development of three-dimensional code capability are all important efforts in addressing these issues. The proposed work is a critical step towards providing confidence through validation of the capability of thermal-hydraulic tools to meet the emerging challenges in reactor simulation. Historically, system analysis codes develop a stiffness over time due to fine-tuning of adjustable code parameters that result in a reluctance or inability to adopt improved models. Therefore, a rigorous effort should be invested in preparation for RELAP-7 to identify required modeling improvements of constitutive relations and validation of the code applicability to the wide range of possible reactor flow conditions. Part of this validation involves the uncertainty quantification which is a critical step in the Code Scaling, Applicability, and Uncertainty (CSAU) methodology and Best-Estimate Plus Uncertainty (BEPU) licensing method. BEPU allows recovery of safety margins and potentially optimizing plant performance, resulting in economic benefit for the reactor operators. Beginning with the collection of past experimental data covering prototypic LWR conditions, this document reviews three critical datasets available for the validation of system codes. The experimental methods, procedures, facilities, instrumentation, and supplementary information are consolidated to aid the validation efforts of this work and future projects. These three datasets (824 conditions) are chosen due to their wide acceptance and demonstrated application for code validation. Two experimental datasets from the Nuclear Power Engineering Corporation (NUPEC) span prototypic conditions of Boiling Water Reactors (BWR) and Pressurized Water Reactors (PWR). These datasets are labeled as the BFBT (BWR Full-size Fine-mesh Bundle Test) and the PSBT (PWR Subchannel and Bundle Test) datasets respectively. The third dataset is taken in an internally heated annulus that is scaled based on a BWR subassembly and includes two-phase flows important to post-blowdown analysis. Together, the datasets consider the full range of pressure and mass flux expected in LWR forced convective flows from steady-state to long term cooling conditions. Recognizing the deficiency of available data under low-pressure, low-flow, a new natural circulation dataset consisting of 107 conditions is obtained. With system pressures ranging between 145 and 950 kPa, natural circulation is driven by a heat flux up to 275 kW/m2 in a 3 m long heated region of the annulus test section which is followed by a 2 m long unheated region before entering a condenser. Stable natural circulation flow rates in this facility were measured to be between 182 and 590 kg/m2-s. Pressure and temperature are measured at ten locations in the facility. In addition, measurements of void fraction, interfacial area concentration, and gas velocity are obtained at five axial locations in the annulus test section. The RELAP5-3D code demonstrates good accuracy for void fraction predictions in BFBT and PSBT benchmarks, but shows relatively large discrepancy in the annulus experiments at lower pressures. In two-phase natural circulation, large oscillations are observed in many system parameters during the simulation of 19 experiment cases which were conducted at low pressures, and the model shows good predictive performance with the remaining 88 experiment cases. However, some discrepancies in void fraction and temperature predictions are found which may require improved constitutive modeling under these low-pressure, low-flow condition. The quantified uncertainty in void fraction predictions in three forced convection benchmarks due to uncertainties in boundary conditions and geometries are relatively small, except for a few cases in the annulus experiment. The output uncertainty of the natural circulation model is quantified by considering the measurement error in boundary conditions, and it is shown that the output uncertainty ranges are relatively small for the range of conditions considered. Through this work, a clear pathway is provided for validation of RELAP7 once the code is available.

42 ENGINEERING↗

Investigation of Technologies to Improve Condenser Heat Transfer and Performance in a Relevant Coal-Fired Power Plant

Improvements in thermal power-generating plant performance is correlated directly to societal benefits including lower cost of reduced fuel consumption, resulting in lower cost of electricity for the consumer and reduced carbon emissions to the atmosphere. Warm steam exhausted from low-pressure steam turbines is condensed to liquid water on the exterior of thin-walled metal condenser tubes with cooling water passing through the tube interior. The condensation of steam creates a vacuum that supports turbine rotation and the concurrent generation of electricity. This vacuum is optimized when heat transfer across the wall of condenser tube is maximized. Common hindrances to heat transfer include foulants in cooling water that may form and adhere to the interior of condenser tubes, including mineral scale, microbiological films, and particulate deposition. Flowing cooling water may also include a laminar layer at the interior metal surfaces that travels more slowly than bulk water flow, serving to impede heat transfer. On the tube exterior, condensing steam forms an insulating layer of water that flows down the tube and reduces the effectiveness of cooling. Both the interior and exterior barriers to optimal heat transfer may be alleviated to some extent by surface treatments. On the tube interior, hydrophobic coatings may be applied that can reduced the adherence of foulants and of the laminar flow layer to the tube surface. On the tube exterior, hydrophobic coatings or mechanical treatments can be applied that may result in the termination of droplet growth and the departure of droplets from the surface rather than coalescence into a continuous layer of flowing water. Fourteen surface treatments were applied to condenser tubes in this study, including eight interior coatings and six exterior treatments, five of which were coatings and one a microstructural texture. Heat transfer measurement equipment simulating conditions in the condenser of an operating power plant was used to determine heat transfer coefficients by measuring sufficient flow, temperature, water chemistry and other data. Several of the tubes with interior surface treatments showed improvement in heat transfer coefficients compared with a plain (uncoated) tube, and several of the tubes with exterior surface treatments also showed enhanced heat transfer coefficients.

01 COAL, LIGNITE, AND PEAT↗

Experimental investigation of elemental and isotopic evaporation processes by laser heating in an aerodynamic levitation furnace

In this report we carried out evaporation experiments on a B-type calcium–aluminium-rich inclusion (CAI) melt in a gas-mixing aerodynamic levitation laser furnace, at 1873 K and an oxygen partial pressure of 10 -9.1 atm, for durations ranging from 60 to 600 s. Evaporation of SiO 2 and MgO follow the same trend as those observed in vacuum furnace experiments at the same temperature and starting composition, showing that their evaporation relative to one another from the melt is independent of pressure, oxygen fugacity, and hydrodynamical regime specific to the furnace. Isotopic ratios of Mg and Si in evaporation residues are used to derive fractionation factors of α 26/24 Mg vap-liq = 0.9906± 0.0004 and α 30/28 Si vap-lip = 0.9943±0.0003, which are both significantly closer to unity than those found for evaporation in a vacuum, which translates to less isotope fractionation. The residues are also less isotopically fractionated than expected for cases in which transport of the gas species away from the melt is diffusion-controlled at 1-atm. By analysing the flow regimes in our furnace, we find that advection by the levitating gas is the primary mode of mass transport away from the melt surface, as opposed to diffusion-limited transport in a vacuum or 1-atm tube furnace. A modified Hertz–Knudsen–Langmuir formulation accounts for this process, and shows that isotopic fractionation of both Si and Mg reflect a saturation factor (ratio of the pressure of the evaporating species to vapour saturation pressure) equal to 0.75. This is in perfect accord with recent measurements of Cu isotopic fractionation using a similar furnace. The fact that three elements (Mg, Si, Cu) with varying equilibrium vapour pressures, activity coefficients in the liquid, and diffusion coefficients in the gas have the same scaling behaviour to saturation pressure is a strong indication that the mechanism controlling evaporation is driven by the hydrodynamical regime imposed in the furnace. Therefore, this class of experiments can be used to constrain processes in which advection dominates over diffusion, such as (but not limited to) planetary ejecta, tektites, giant impacts, nebular condensation in a turbulent flow, or nuclear fallout material. Finally, the possibility to reach high temperatures (in excess of 3500 K) in this furnace allows it to be used to evaluate the activity coefficients of melt components in extreme conditions relevant to molten planetary interiors (i.e., magma oceans), with a specific focus on refractory elements.

58 GEOSCIENCES↗

Potential for exciton condensation in a highly conductive amorphous polymer

An outstanding challenge in synthesis and theory is to develop molecular materials at ambient conditions that exhibit highly efficient energy transfer. Here, in this study, we demonstrate the potential of a recently synthesized, highly conductive amorphous material—a nickel tetrathiafulvalene-tetrathiolate (NiTTFtt) polymer—to become an exciton condensate—a Bose-Einstein condensate of particle-hole pairs, known as excitons, that supports dissipationless flow of excitation energy. While exciton condensates have recently been realized in ordered materials, we show by advanced electronic structure calculations that this highly correlated phenomenon can potentially be realized in molecularly tailored, amorphous materials. In contrast to the Bechgaard salts that support superconductivity at compressed geometries requiring high pressures, we show that the recently synthesized, amorphous NiTTFtt polymer exhibits the computational signature of exciton condensation at experimentally realizable geometries, occurring at ambient pressures. Results suggest that superfluidity in this system and related systems—including van der Waals structures, molecular metals with extended-TTF dithiolate ligands, and Bechgaard salts—may occur via a nontraditional excitonic mechanism tuneable according to system composition, geometry, size, and charge. This study prompts further experimental investigation of the rational design of molecularly scaled exciton condensates with potential applications to efficient transport in technologically relevant materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New principles of self‐organization created through the interplay of DNA condensates, microtubules, and motors

Bioinspired design—which holds great promise for a new generation of materials that are robust to defects, scalable under green manufacture, environmentally responsive, and programmably reconfigurable—requires mastery over molecular self-organization. Yet, from its specific mechanisms to most general architectures, the principles governing self-organization remain poorly understood and not even fully enumerated. For living systems, one obvious architectural principle is the modular reuse of a few simple molecular components in myriad combinations to achieve more complex phenomena. For example, the mechanical tasks of a cell are driven by the nonequilibrium dynamics of cytoskeletal filaments and molecular motors—the same filaments and motors, reprogrammed by a variety of modulators, perform tasks ranging from cell movement to division. Similarly, many compartmentalization tasks are performed by liquid-like condensates of simple components, which act as membraneless organelles to localize particular molecules in space and time (e.g. for gene regulation or RNA processing). In a few cases, condensates combine and interact with the cytoskeleton to create still more complex phenomena, e.g. the nucleation of microtubule asters from the centrosome (a protein condensate) to form the mitotic spindle during cell division. Very little is known about the fundamental mechanisms of such filament-plus-condensate phenomena. Despite few examples, the landscape of behaviors that can be achieved through the combination of condensates, filaments, and motors appears vast. However, exploration has been hindered by a lack of systems that have sufficiently programmable and dynamically tunable interactions between component condensates, filaments, and motors. We proposed to combine programmable DNA condensates, filamentous microtubules, and light-controlled motors into self-organizing systems whose principles go beyond those that have been observed in nature. In one limit, our systems will use microtubules and motors to create the molecular analog of a network of roads, which will organize droplets of DNA condensates capable of carrying molecular cargo. DNA condensates coupled to motors will flow from one microtubule aster hub to another, with their direction and timing controlled by DNA circuits. In another limit, microtubules will swim through bulk DNA condensates and exhibit strong interactions with boundaries between different types of condensates. Microtubule swimmers will reflect, get trapped, or refract at boundaries, under a mechanical analog of the classical optical index of refraction. DNA condensates having different mechanical indexes of refraction will be used to construct the analog of optical lenses, so that microtubule swimmers can be manipulated like light—collimated, diffracted, focused, and sorted based on properties analogous to wavelength. These two limits define two new architectures, within which multiple new mechanistic principles for self-organization will be discovered and explored. To explore these architectures, the motor-based coupling between DNA condensates and filaments will be controlled in time and space through the use of opto-proteins that create reversible links between DNA condensates and motors upon illumination. For each principle of interest, patterns of light will create virtual experiments by defining patterns of activity where DNA condensates walk along filaments, or filaments swim through condensates, and patterns of inactivity which will serve either as controls, or as boundary conditions vital to create the desired phenomena. This research serves the goals of Basic Energy Sciences Biomolecular Material Program by elucidating the principles by which the emergent, nonequilibrium behavior of collections of DNA condensates, motors, and microtubules can be programmed by environmental light patterns to create complex motion and materials transport. Because DNA condensates can be readily coupled to virtually any high performance nanomaterial, from carbon nanotubes, to metal nanoparticles, to light harvesting systems, this work provides a path to the construction, self-maintenance and reconfiguration of materials relevant to the Department of Energy.

60 APPLIED LIFE SCIENCES↗

Particle charge distributions in the effluent of a flow-through atmospheric pressure low temperature plasma

Atmospheric pressure low-temperature plasmas are often utilized to perform particle synthesis, treatment, and removal. It is well-known that dust particles are highly negatively charged in these plasmas; however, little is known about dust particle charging behavior as particles leave the plasma volume and pass through the spatial afterglow region. In this work, monodisperse particles of various sizes and work functions were introduced into an atmospheric pressure radiofrequency capacitively coupled flow-through plasma. Dust particle electrical mobility distributions downstream of the flow-through plasma were measured utilizing a differential mobility analyzer in conjunction with a condensation particle counter at various gas flow velocities. Charge distributions were determined from the measured electrical mobility distributions. Experiments confirm that particles become less negatively charged, and even net-positively charged after leaving the plasma volume, with a distribution that follows a shifted Boltzmann charge distribution. Additionally, particle charge in the effluent of the flow-through plasma is negligibly dependent on work function but highly size and flow velocity dependent. Larger particles were shown to have a higher magnitude of charge under all studied conditions; however, particle polarity was switchable by varying gas flow velocity. The charging dynamics were simulated utilizing a constant number Monte Carlo model that accounts for electron temperature decay and the transition from ambipolar to free diffusion of electrons and ions in the spatial afterglow. Simulation results also suggest that, at the same flow velocity, larger particles obtain a greater magnitude of charge, negative or positive. Furthermore, the decrease in electron mobility and the difference between ion and electron convective loss rates create an ion-rich region in the plasma effluent that promotes ion–particle collisions and drives particle charge removal and even reversal of polarity. Larger particles more favorably collide with energetic species in these environments, which results in higher charge states.

atmospheric pressure low temperature plasma↗

Experimental Investigation of Uranium and Iron Condensation from High-Temperature Plasma Conditions

We used a plasma flow reactor (PFR) to generate synthetic fallout nanoparticles from vapor-phase condensation of two different input concentrations of uranium and iron analytes (U/Fe = 1:1 and 1:2). Synthetic fallout from complex chemical matrices (e.g., mixtures of U and Fe) has not been generated in this setup before and allows for the observation of relative condensation and fractionation of nuclear debris. Experiments were conducted under two different temperature histories with variations in particle flow patterns along the PFR. Transmission electron microscopy (TEM) observation and analysis of the nanoparticles revealed variations in speciation of uranium oxides (UO 2 and α-UO 3 ) depending on the competition between flow mixing and oxygen sequestration by iron. A ternary metal oxide, UFeO 4 , was observed in addition to iron oxides (e.g., FeO and Fe 3 O 4 ), which suggests that fallout models should account for chemical speciation of ternary metal oxides (i.e., UFeO 4 ) and their relative condensation behaviors in addition to those of singular metal oxides (e.g., FeO and UO 2 ). X-ray Energy Dispersive Spectroscopy (EDS) elemental maps showed that some particles had Fe-rich cores surrounded by U-rich regions. This suggests that either condensed U oxides coagulate onto molten Fe oxides or that the increase in iron analyte concentration might drive the system toward a higher degree of supersaturation, leading to earlier formation of iron oxide particles and providing an energetically favored pathway for nucleation of uranium oxides around iron oxide particles.

and nuclear chemistry↗

Role of collisionality and radiative cooling in supersonic plasma jet collisions of different materials

Currently there is considerable interest in creating scalable laboratory plasmas to study the mechanisms behind the formation and evolution of astrophysical phenomena such as Herbig-Haro objects and supernova remnants. Laboratory-scaled experiments can provide a well diagnosed and repeatable supplement to direct observations of these extraterrestrial objects if they meet similarity criteria demonstrating that the same physics govern both systems. Here, we present a study on the role of collision and cooling rates on shock formation using colliding jets from opposed conical wire arrays on a compact pulsed-power driver. These diverse conditions were achieved by changing the wire material feeding the jets, since the ion-ion mean free path (λmfp-ii) and radiative cooling rates (Prad) increase with atomic number. Low Z carbon flows produced smooth, temporally stable shocks. Weakly collisional, moderately cooled aluminum flows produced strong shocks that developed signs of thermal condensation instabilities and turbulence. Weakly collisional, strongly cooled copper flows collided to form thin shocks that developed inconsistently and fragmented. Effectively collisionless, strongly cooled tungsten flows interpenetrated, producing long axial density perturbations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methods for Carbon Mass Closure in Polyolefin Hydrocracking

Heterogeneous catalytic hydrocracking of polyolefins is a promising approach for the processing of postconsumer plastics, but product quantification methods remain inconsistent across the literature. In systems that generate a large fraction of vapor-phase products, typical product capture methods can result in large carbon balance deficits, exceeding 50%, compromising reported yields and selectivities. Here, we identify the major sources of product loss and develop enhanced capture methods to improve the quantification accuracy. Seven supplemental techniques were evaluated, targeting either increased vapor recovery (by increasing the volatility or system volume) or enhanced retention in the liquid phase (by decreasing volatility). Among these, a flow collection approach using a continuous helium sweep and downstream gas sampling bag capture yielded the highest recovery, achieving a 96 ± 9.2% carbon balance closure. We show that the efficacy of these methods is strongly dependent on product distribution. In general, solvent addition was most effective when condensable species dominate the product distribution, while flow collection was preferred when both condensable species and light gases are present in high concentrations. These results highlight the need for method-specific workup strategies and demonstrate that no single protocol is universally optimal. We provide general guidelines for selecting and implementing robust product capture techniques, enabling accurate yield and selectivity determinations in polyolefin hydrocracking systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Investigation of a Novel Membrane-Based Condensing Heat Exchanger for High Efficiency Furnaces

Building space heating consumes approximately one-third of all global natural gas end use. Higher-efficiency (i.e., condensing) furnaces constitute only about 30% of the annual furnace shipments in the United States because the condensing heat exchangers must use highly expensive, corrosion-resistant materials to be protected from acidic components in the furnace flue gas stream. Increasing the market share of high-efficiency furnaces will reduce greenhouse gas emissions. This study developed and tested a benchtop prototype of a novel membrane-based heat exchanger (MHX) for high-efficiency furnaces to achieve nonacidic condensation via nanoporous membranes. Test results show that both sensible and latent heat were recovered by the MHX, and the fraction of latent heat recovery ranged from about 25% to 45% over the range of operating conditions evaluated. The amount of water condensed through the MHX increased with the increase of flue gas flow rate and decreased with increasing coolant temperature. The fraction of latent heat recovery decreased with the increase of flue gas flow rate and coolant temperature. The pH value of condensed water from the MHX was only mildly acidic, varying from 5.3 to 5.6 without any additional treatment, about 2.0 to 2.3 pH points higher (i.e., less acidic) than typical values for the condensate from conventional condensing furnaces. Therefore, feasibility of the MHX was experimentally verified, and the MHX could enable wider market penetration of highly energy-efficient condensing furnaces by reducing costs associated with managing the acid condensation compared with conventional condensing furnaces, possibly enabling the use of existing vent systems when replacing noncondensing furnaces (due to higher flue gas exit temperatures), and possibly reducing furnace first costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooling Strategies for an Electric Motor with Additively Manufactured Hollow Conductors and Distributed Power Electronics Integrated with Heat Pipes

This paper discusses design tradeoffs and thermal modeling explored in cooling strategies for an aircraft propulsion electric motor with additively manufactured coils and distributed power electronics integrated with heat pipes. Design tradeoffs include heat pipe Qmax performance related to inclination, condenser configuration, coolant type, coolant flow path complexity, and ease of access to modular power electronics. Three cooling strategies were selected and realized into CAD models. These models were further evaluated using 3D thermal FEA and optimization tools to explore cooling geometry details that include fin thickness, spacing and count with the objective to minimize fin mass under a set of constraints. Lastly, motorette test data is presented comparing air versus liquid cooling of heat pipes.

additive manufacturing↗

Separating Sensible and Latent Cooling with Electrically Charged Rotating Vortexes and Vapor Capturing Air Handler Technology

The dehumidification of air is a highly energy-intensive process, typically requiring vapor compression systems to cool the air below its dew point temperature. This project investigated air dehumidification achieved by electrostatic and dielectrophoresis forces in electrosprays and centrifugal principles in cyclone separators. As a practical implementation of these processes, Electrospray Vortical Flow eXchanger (EVFX) prototypes were designed, fabricated, and tested. Electrosprays were employed to energize water droplets, which then captured water vapor via dielectrophoresis. A cyclone separator was positioned downstream of the electrosprays. This combination increased the dehumidification efficiency and controlled the flow of the water vapor condensate removed from the air.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation of Low-Cost Condensers Immersed in the Water Tank of a Heat Pump Water Heater

This paper reports the effect of low-cost immersed condensers on the performance of a heat pump water heater (HPWH) that does not require a water-circulating pump. The proposed design is based on the immersion of an L-style condenser coil through an opening in the top of the water tank. The novel design aims to eliminate the need for the water-circulating pumps, thereby substantially improving efficiency and reducing costs and maintenance of the HPWH system. Comprehensive computational fluid dynamics (CFD) simulations and experimental tests were performed, and the results showed that the CFD simulations were close to the experimental data. Further results confirm that the L-style condenser can introduce buoyancy-driven flow and eliminate temperature stratification in the studied HPWH water tank, thereby improving the heat transfer coefficient and coefficient of performance of the HPWH. The testing results further showed that the L-style condenser enabled more than 53% higher coefficient of performance and 400% higher heat transfer coefficient compared with the straight vertical condenser, and achieved much faster water heating. Furthermore, the effects of immersed condensers with different circuits on the HPWH performance were evaluated and compared. All results indicate that the current energy-saving and inexpensive HPWH technology is technically valid, and the benefits of performance improvement and low cost are attractive in future HPWH design.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗