At least 55 records · Page 3

Cluster analysis of multiple planetary flow regimes

A modified cluster analysis method developed for the classification of quasi-stationary events into a few planetary flow regimes and for the examination of transitions between these regimes is described. The method was applied first to a simple deterministic model and then to a 500-mbar data set for Northern Hemisphere (NH), for which cluster analysis was carried out in the subspace of the first seven empirical orthogonal functions (EOFs). Stationary clusters were found in the low-frequency band of more than 10 days, while transient clusters were found in the band-pass frequency window between 2.5 and 6 days. In the low-frequency band, three pairs of clusters determined EOFs 1, 2, and 3, respectively; they exhibited well-known regional features, such as blocking, the Pacific/North American pattern, and wave trains. Both model and low-pass data exhibited strong bimodality.

Mo, Kingtse↗

Gas Flux and Density Surrounding a Cylindrical Aperture in the Free Molecular Flow Regime

The equations for rigorously calculating the particle flux and density surrounding a cylindrical aperture in the free molecular flow regime are developed and presented. The fundamental equations for particle flux and density from a reservoir and a diffusely reflecting surface will initially be developed. Assumptions will include a Maxwell-Boltzmann speed distribution, equal particle and wall temperatures, and a linear flux distribution along the cylindrical aperture walls. With this information, the equations for axial flux and density surrounding a cylindrical aperture will be developed. The cylindrical aperture will be divided into multiple volumes and regions to rigorously determine the surrounding axial flux and density, and appropriate limits of integration will be determined. The results of these equations will then be evaluated. The linear wall flux distribution assumption will be assessed. The axial flux and density surrounding a cylindrical aperture with a thickness-to-radius ratio of 1.25 will be presented. Finally, the equations determined in this study will be verified using multiple methods.

Soulas, George C.↗

Hot-wire calibration in subsonic/transonic flow regimes

A different approach for calibrating hot-wires, which simplifies the calibration procedure and reduces the tunnel run-time by an order of magnitude was sought. In general, it is accepted that the directly measurable quantities in any flow are velocity, density, and total temperature. Very few facilities have the capability of varying the total temperature over an adequate range. However, if the overheat temperature parameter, a(sub w), is used to calibrate the hot-wire then the directly measurable quantity, voltage, will be a function of the flow variables and the overheat parameter i.e., E = f(u,p,a(sub w), T(sub w)) where a(sub w) will contain the needed total temperature information. In this report, various methods of evaluating sensitivities with different dependent and independent variables to calibrate a 3-Wire hot-wire probe using a constant temperature anemometer (CTA) in subsonic/transonic flow regimes is presented. The advantage of using a(sub w) as the independent variable instead of total temperature, t(sub o), or overheat temperature parameter, tau, is that while running a calibration test it is not necessary to know the recovery factor, the coefficients in a wire resistance to temperature relationship for a given probe. It was deduced that the method employing the relationship E = f (u,p,a(sub w)) should result in the most accurate calibration of hot wire probes. Any other method would require additional measurements. Also this method will allow calibration and determination of accurate temperature fluctuation information even in atmospheric wind tunnels where there is no ability to obtain any temperature sensitivity information at present. This technique greatly simplifies the calibration process for hot-wires, provides the required calibration information needed in obtaining temperature fluctuations, and reduces both the tunnel run-time and the test matrix required to calibrate hotwires. Some of the results using the above techniques are presented in an appendix.

Nagabushana, K. A.↗

Flow Regime Based Climatologies of Lightning Probabilities for Spaceports and Airports

Objective: provide forecasters with a "first guess" climatological lightning probability tool (1) Focus on Space Shuttle landings and NWS T AFs (2) Four circles around sites: 5-, 10-, 20- and 30 n mi (4) Three time intervals: hourly, every 3 hr and every 6 hr It is based on: (1) NLDN gridded data (2) Flow regime (3) Warm season months of May-Sep for years 1989-2004 Gridded data and available code yields squares, not circles Over 850 spread sheets converted into manageable user-friendly web-based GUI

Bauman, William H., III↗

Dynamics, statistics and predictability of planetary flow regimes

Consideration is given to regimes of low-frequency variability in large-scale atmospheric dynamics. The model utilized is the fully-nonlinear, equivalent-baratropic vorticity equation on the sphere, with simplified forcing, dissipation and topography. It is found that certain limited regions in the system's phase space are visited repeatedly and for extended periods by model solutions. Flow patterns coupled with these regions correspond to synoptically-defined zonal and blocked Northern Hemisphere midlatitude flows. It is shown that the system's macrodynamics can be depicted by two or more planetary flow regimes, the expected residence time in each regime, and the transition properties from one regime to another. These model-derived ideas are also applied to a time series of atmospheric data from the Southern Hemisphere.

Ghil, Michael↗

Tree-Based Ensemble Learning Models for Wall Temperature Predictions in Post-Critical Heat Flux Flow Regimes at Subcooled and Low-Quality Conditions

Accurately predicting post-critical heat flux (CHF) heat transfer is an important but challenging task in water-cooled reactor design and safety analysis. Although numerous heat transfer correlations have been developed to predict post-CHF heat transfer, these correlations are only applicable to relatively narrow ranges of flow conditions due to the complex physical nature of the post-CHF heat transfer regimes. In this paper, a large quantity of experimental data is collected and summarized from the literature for steady-state subcooled and low-quality film boiling regimes with water as the working fluid in vertical tubular test sections. In addition, a low-quality water film boiling (LWFB) database is consolidated with a total of 22,813 experimental data points, which cover a wide flow range of the system pressure from 0.1 to 9.0 MPa, mass flux from 25 to 2750 kg/m 2 s, and inlet subcooling from 1 to 70 °C. Two machine learning (ML) models, based on random forest (RF) and gradient boosted decision tree (GBDT), are trained and validated to predict wall temperatures in post-CHF flow regimes. The trained ML models demonstrate significantly improved accuracies compared to conventional empirical correlations. To further evaluate the performance of these two ML models from a statistical perspective, three criteria are investigated and three metrics are calculated to quantitatively assess the accuracy of these two ML models. For the full LWFB database, the root-mean-square errors between the measured and predicted wall temperatures by the GBDT and RF models are 5.7% and 6.2%, respectively, confirming the accuracy of the two ML models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Development of a Generalized Riser Flow Regime Map Based Upon Higher Moment and Chaotic Statistics Using Electrical Capacitance Volume Tomography (ECVT)

Dynamic analyses have been applied to the temporal signals from an Electro Capacitance Volume Tomography instrument located near mid-height on the riser of an industrial-scale cold-flow circulating fluidized bed to characterize gas-solids flow behavior in the riser. Twelve capacitance electrodes surround the cylindrical riser over a height of 1.3 m. The instrument used a neural network deconvolution algorithm to determine the spatially resolved solids fraction recorded at 52 Hz. Experiments were carried out over a range of gas and solids flows in the transport regime using a Geldart Group B bed material, high density polyethylene with mean particle size of 880 μm. The radial solids distribution was found to vary from one-time step to the next between profiles typical of laminar and turbulent flow. The duration of time spent in each of these flow profiles depended upon the operating regime – dilute, core-annular, or fast fluidized bed. The chaotic structure of the temporal data was characterized using the three conventional approaches: the first 4 moments from the distribution of signal in time, system memory parameters from the autocorrelation function and the Hurst exponent, and analysis of the correlationentropy and correlation dimension of the attractor. These signal analysis techniques were used to clearly distinguish differences between different transport operating regimes. Specifically, it was experimentally observed that a riser transitions from core annular flow profile to dilute and dense regimes via increasing the frequency of short term transients to either dilute or dense flow profiles, respectively. A regime map was generated based upon these dynamics using solids flux and gas velocity axes. Fast fluidized, core annular, and dilute each exhibited different degree of dynamic characteristics typical of fluid dominated or particle compromising behavior. It should be noted that the magnitude for the different statistics was in the same range regardless of the regime, it was the radial profile for the statistic that changed and subsequently identified that there was a change in the regime. Finally, a reduced regime map was developed consisting of plotting the gas velocity normalized by the upper transport velocity versus the solids flux normalized by the saturation carrying capacity. The use of this reduced plot allowed the data from widely different conditions to be plotted and compared on the same<p>graph. Note that in many instances, some of the statistics identified the operating point as being in one regime while others indicated that it was in another indicating a transition region between dilute or core annular regimes and between the core annular and fast fluidization regimes. This now provides a tool that can be used to optimize process performance, identify changes in operating states, or replicate process dynamics during process scaling or changing operating parameters. </p>

Breault, Ronald↗

Convection of tin in a Bridgman system. II - An electrochemical method for detecting flow regimes

An ampoule was designed in order to obtain local flow behavior of the flow fields for convection of tin in a vertical Bridgman configuration. Multiple electrochemical cells were located along the periphery of the ampoule. Oxygen was titrated into the ampoule at one of the cell locations using a potentiostat and the concentration of oxygen was monitored at the other cell locations by operating the cells in a galvanic mode. Onset of oscillations were detected by means of thermocouples. We conclude that the flows are generally three dimensional for an aspect ratio of 5. Results on oscillations concurred with those of earlier workers. Suggestions for improved designs were made.

Sears, B.↗

Intermittent Flow Regimes in a Transonic Fan Airfoil Cascade

A study was conducted in the NASA Glenn Research Center linear cascade on the intermittent flow on the suction surface of an airfoil section from the tip region of a modern low aspect ratio fan blade. Experimental results revealed that, at a large incidence angle, a range of transonic inlet Mach numbers exist where the leading-edge shock-wave pattern was unstable. Flush mounted high frequency response pressure transducers indicated large local jumps in the pressure in the leading edge area, which generates large intermittent loading on the blade leading edge. These measurements suggest that for an inlet Mach number between 0.9 and 1.0 the flow is bi-stable, randomly switching between subsonic and supersonic flows. Hence, it appears that the change in overall flow conditions in the transonic region is based on the frequency of switching between two stable flow states rather than on the continuous increase of the flow velocity. To date, this flow behavior has only been observed in a linear transonic cascade. Further research is necessary to confirm this phenomenon occurs in actual transonic fans and is not the byproduct of an endwall restricted linear cascade.

Lepicovsky, J.↗

Comparing Particle Flow Regimes in the L2K Arcjet with Martian Entry Conditions

The DLR L2K arcjet facility has the ability to run experiments with particle-laden flows in a CO2-N2 gas mixture that simulates the Martian atmosphere. When running computer simulations of particle-laden flows, it is important to properly assess the drag forces on the particles as they travel through a shock layer. Key parameters that determine the drag force are the particle Mach and Reynolds numbers. In this study, flow conditions in the L2K arcjet are compared against conditions that will be present during a Martian entry.

particle flows↗

Three-Dimensional, Multi-Phase Unsteady Flow of Water Undergoing Multiple Flow Regimes (Free Surface, Droplet, and Fluid Film)

Upgrades to the Mobile Launcher Rainbird nozzles were implemented for the Artemis II launch to increase water flow rates and improve the mobile launcher deck water coverage while minimizing the water throw distance to avoid impacting the Space Launch System (SLS) rocket nozzles. This analysis describes the use of a three-dimensional, multi-phase, free surface transient computational fluid dynamics (CFD) model to simulate the water flowing out through the Rainbird nozzle and ensure compliance with current Artemis requirements. Flow rates, pressures, velocities, nozzle throw distances and coverage areas were analyzed to ensure that system requirements are met. The completed results were used to make necessary modifications to the Ignition Overpressure Protection and Sound Suppression (IOP/SS) system Rainbird design by reshaping the nozzle used in the system.

CFD↗

Comparing Particle Flow Regimes in the L2K Arcjet with Martian Entry Conditions

In this study, the US3D-DUST code will be used to simulate particles in the L2K dusty-flow test environments and compare them to conditions in the shock layer of the Schiaparelli capsule during its entry into the Martian atmosphere in 2016. The particle Reynolds, Mach, and Knudsen numbers, key non-dimensional numbers that characterize the dusty-flow environments, will be compared between the L2K and Martian shock layers. This study will provide a preliminary assessment of how well-suited L2K dusty-flow conditions are for particle drag model validation and the development of particle impact surface damage correlations. The results of this study may help to guide the design of future dusty flow environments in the L2K facility

Dusty flow↗