Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow through balance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A New Flow-Through Wind Tunnel Balance for Retropropulsion Testing

Supersonic retropropulsion is believed to be an enabling technology for large-scale human Mars lander vehicle concepts. Ground testing of such vehicles requires the development of new flow-through wind tunnel balances because no suitable balances exist. A new flow-through balance is designed that employs membranes in place of bellows, which have historically been used, and that passes the flow through load bearing parts of the balance. Flow through the balance is optimized via the addition of flow guides, which are manufactured as separate parts, and attached to the balance. Calibration of this new flow-through balance demonstrates that it can suitably characterize the load and pressure ranges it was designed for, which provides aero researchers a new tool to directly measure supersonic retropropulsion performance of powered descent vehicles.

Flow through balance↗

Advancements in Force and Angle Measurement by the NFMTC

The National Force Measurement Technology Capability (NFMTC) is a nationwide partnership established in 2008 and sponsored by NASA’s Aeronautics Evaluation and Test Capabilities (AETC) project to maintain and further develop force and angle measurement capabilities primarily for NASA’s ground test facilities. One of the NFMTC’s primary objectives is to develop new force and angle measurement capabilities to meet the needs of researchers testing in NASA’s ground test facilities. This work will highlight several new capabilities that are either at or near operational readiness. A new six-component flow-through balance was designed and fabricated to support an upcoming retropropulsion test campaign at the NASA Langley Unitary Plan Wind Tunnel. The balance employs membranes in place of bellows, which have historically been used, and passes the flow through load bearing parts of the balance. Flow through the balance is optimized via the addition of flow guides, which are manufactured as separate parts, and attached to the balance. Calibration of this new flow-through balance demonstrates that it can suitably characterize the load and pressure ranges it was designed for, which provides aero researchers a new tool to directly measure retropropulsion performance of powered descent vehicles. Balances used in NASA’s ground test facilities are typically either single-piece balances or floating-frame balances. Historically, these two types of balances have generally used different front-end (model) attachments. Single-piece balances generally have a cylindrical front end that is forward of any measuring sections and at a reduced diameter relative to the balance outer diameter. Floating-frame balances generally have front end fits that extend over one or more measuring sections and that engage at the balance outer diameter. Recently, the NFMTC fabricated a single-piece balance with a front end fit that is compatible with the hardware used to calibrate floating-frame balances. Calibration results evaluating this front end fit will be presented. From a recent survey of angle measurement needs, the development of smaller angle measurement packages was identified as one area of improvement. Micro-electromechanical systems (MEMS) are continually being refined to provide high performance accelerometers that are a fraction of the volume of the quartz flexure based accelerometers that are standard in wind tunnels. A survey of commercial off-the-shelf MEMS accelerometers was conducted, and it identified the Safran Colibrys MS lines to be of adequate performance. Single-axis test boards and tri-axis rigid-flex production boards were designed and fabricated with a volume of approximately .18 cubic inches. The boards were designed to provide all the necessary conditioning for the MEMS accelerometers at levels to meet or exceed all requirements for the MS line sensors. Preliminary testing of these assembled sensor packages has demonstrated acceptable performance for wind-tunnel angle measurement. Several new rotating balances are at various stages of completion for NASA Glenn Research Center’s fan drive rigs. These balances provide direct measurement of thrust and torque of a driven fan or fan section to provide an estimate of fan efficiency and net thrust. Three two-component balances have been recently completed, and one six-component balance is in active development. A custom rotating telemetry system has been developed to support testing with these balances, and the telemetry system is integrated into the forward end of each one. The telemetry system is designed to remove mechanical sliprings by using an optical ethernet-based slipring for data transmission.

Force measurement↗

Computations of Torque-Balanced Coaxial Rotor Flows

Interactional aerodynamics has been studied for counter-rotating coaxial rotors in hover. The effects of torque balancing on the performance of coaxial-rotor systems have been investigated. The three-dimensional unsteady Navier-Stokes equations are solved on overset grids using high-order accurate schemes, dual-time stepping, and a hybrid turbulence model. Computational results for an experimental model are compared to available data. The results for a coaxial quadcopter vehicle with and without torque balancing are discussed. Understanding interactions in coaxial-rotor flows would help improve the design of next-generation autonomous drones.

Torque↗

Balanced-force flow-regulator valve

Valve regulates fluid pressure or flow by means of porous barrier and reduces surfaces exposed to liquid or gas flow that cause unbalanced pressure forces. Applications include hand valves, spool valves, and other devices that meter or control gases or liquids.

Huber, W. C.↗

A simple model of fluid flow and electrolyte balance in the body

The model is basically a three-compartment model, the three compartments being the plasma, interstitial fluid and cellular fluid. Sodium, potassium, chloride and urea are the only major solutes considered explicitly. The control of body water and electrolyte distribution is affected via drinking and hormone levels. Basically, the model follows the effect of various oral input water loads on solute and water distribution throughout the body.

White, R. J.↗

Analysis of a six-component, flow-through, strain-gage, force balance used for hypersonic wind tunnel models with scramjet exhaust flow simulation

The thermal effects of simulant gas injection and aerodynamic heating at the model's surface on the measurements of a non-watercooled, flow through balance were investigated. A stainless steel model of a hypersonic air breathing propulsion cruise missile concept (HAPCM-50) was used to evaluate this balance. The tests were conducted in the 20-inch Mach 6 wind tunnel at NASA-Langley. The balance thermal effects were evaluated at freestream Reynolds numbers ranging from .5 to 7 x 10(exp 6) ft and angles of attack between -3.5 to 5 deg at Mach 6. The injection gases considered included cold air, hot air, and a mixture of 50 percent Argon and 50 percent Freon-12. The stagnation temperatures of the cold air, hot air, and Ar-Fr(12) reached 111, 214, and 283 F, respectively within the balance. A bakelite sleeve was inserted into the inner tube of the balance to minimize the thermal effects of these injection gases. Throughout the tests, the normal force, side force, yaw moment, roll moment, and pitching moment balance measurements were unaffected by the balance thermal effects of the injection gases and the wind tunnel flow. However, the axial force (AF) measurement was significantly affected by balance heating. The average zero shifts in the AF measurements were 1.9, 3.8, and 5.9 percent for cold air, hot air, and Ar-Fr(12) injection, respectively. The AF measurements decreased throughout these tests which lasted from 70 to 110 seconds. During the cold air injection tests, the AF measurements were accurate up to at least ten seconds after the model was injected into the wind tunnel test section. For the hot air and Ar-Fr(12) tests, the AF measurements were accurate up to at least five seconds after model injection.

Kniskern, Marc W.↗