Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Neutron Fluence and Kerma Responses to Bare, Steel-Reflected, and Lucite-Reflected Steady-State Operations of the ORNL Health Physics Research Reactor

The experiments evaluated in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the Fast Burst Reactor. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. In this evaluation, a total of 12 experiments were evaluated (6 shield configurations and two responses). Six of them are considered acceptable as benchmark experiments and are thoroughly described: the measurands are bare, steel-shielded and Lucite-shielded neutron fluences and neutron KERMA responses to steady-state operations of the HPRR. It is important to mention that there is a general lack of information in the experimental methodology and neutron spectrum unfolding, and in some cases, unexpected and unexplained discrepancies between calculation and experiment. The HPRR’s unique characteristics were that it is a fast reactor, the use of a Lucite shield as the shielding material, and the use of the neutron fluence as the main benchmark measurand. There are no known, significant correlations between benchmarks in this evaluation and benchmarks in other evaluations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strengthening of tungsten by coherent rhenium precipitates formed during low fluence irradiation

Experimental data show that the accumulation of rhenium and osmium from transmutation reactions severely affect the microstructural evolution and property degradation of tungsten-based materials under neutron irradiation. Theory and modeling have confirmed that Re atom transport in W is by irradiation-produced migrating self-interstitial atoms. With this diffusion mode in operation, a specific microstructure evolution is realized when at relatively low neutron fluence the Re-rich precipitates are formed, while the void and interstitial loop population development is suppressed, affecting the mechanical properties. Here, this research shows the effect of small coherent Re-rich precipitates on the dislocation glide under stress, investigated using the molecular dynamics approach with empirical interatomic potentials. The results are compared with an earlier simulation of void hardening in W. It is demonstrated that small coherent Re-rich precipitates of less than 6 nm diameter represent relatively weak obstacles for moving edge dislocations. The implication of these results on the interpretation of experimental results is discussed.

36 MATERIALS SCIENCE↗

Revealing the chemical environment of Cr, Fe, and Ni in high temperature-ultrafine precipitate strengthened steel subjected to low fluence neutron irradiation

High-temperature ultrafine-precipitate-strengthened (HT-UPS) steel has potential applications in advanced nuclear reactors as a structural material. However, little is currently known about its response to neutron irradiation. This research provides insight into the neutron irradiation-induced physicochemical changes of the major constituents in HT-UPS steels, including Fe, Cr, and Ni, using synchrotron X-ray absorption near edge structure (XANES) and diffraction. This study is the first known investigation using XANES to characterize HT-UPS steel to analyze the evolution of the atomic level chemistry. It was found that following irradiation, nucleation, ballistic dispersion, and/or coarsening of Cr 23 C 6 precipitates occurred at very low neutron irradiation fluences, from 0.003 displacements per atom (dpa) up to 0.3 dpa, at ~600°C, which were at least an order of magnitude lower than previous studies. Calculations of the angular momentum projections, partial density of states, and the XANES spectra confirmed the experimental findings of the Cr 23 C 6 precipitate evolution. In contrast, the local atomic structure around Fe and Ni atoms demonstrated irradiation resistance.

36 MATERIALS SCIENCE↗

Functional Connectivity of Red Chlorophylls in Cyanobacterial Photosystem I Revealed by Fluence-Dependent Transient Absorption

External stressors modulate the oligomerization state of photosystem I (PSI) in cyanobacteria. The number of red chlorophylls (Chls), pigments lower in energy than the P700 reaction center, depends on the oligomerization state of PSI. Here, we use ultrafast transient absorption spectroscopy to interrogate the effective connectivity of the red Chls in excitonic energy pathways in trimeric PSI in native thylakoid membranes of the model cyanobacterium Synechocystis sp. PCC 6803, including emergent dynamics, as red Chls increase in number and proximity. Fluence-dependent dynamics indicate singlet–singlet annihilation within energetically connected red Chl sites in the PSI antenna but not within bulk Chl sites on the picosecond time scale. These data support picosecond energy transfer between energetically connected red Chl sites as the physical basis of singlet–singlet annihilation. The time scale of this energy transfer is faster than predicted by Förster resonance energy transfer calculations, raising questions about the physical mechanism of the process. Our results indicate distinct strategies to steer excitations through the PSI antenna; the red Chls present a shallow reservoir that direct excitations away from P 700 , extending the time to trapping by the reaction center.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of pump laser fluence on ultrafast myoglobin structural dynamics

High-intensity femtosecond pulses from an X-ray free-electron laser enable pump–probe experiments for the investigation of electronic and nuclear changes during light-induced reactions. On timescales ranging from femtoseconds to milliseconds and for a variety of biological systems, time-resolved serial femtosecond crystallography (TR-SFX) has provided detailed structural data for light-induced isomerization, breakage or formation of chemical bonds and electron transfer. However, all ultrafast TR-SFX studies to date have employed such high pump laser energies that nominally several photons were absorbed per chromophore. As multiphoton absorption may force the protein response into non-physiological pathways, it is of great concern whether this experimental approach allows valid conclusions to be drawn vis-à-vis biologically relevant single-photon-induced reactions. Here we describe ultrafast pump–probe SFX experiments on the photodissociation of carboxymyoglobin, showing that different pump laser fluences yield markedly different results. In particular, the dynamics of structural changes and observed indicators of the mechanistically important coherent oscillations of the Fe–CO bond distance (predicted by recent quantum wavepacket dynamics) are seen to depend strongly on pump laser energy, in line with quantum chemical analysis. Our results confirm both the feasibility and necessity of performing ultrafast TR-SFX pump–probe experiments in the linear photoexcitation regime. We consider this to be a starting point for reassessing both the design and the interpretation of ultrafast TR-SFX pump–probe experiments such that mechanistically relevant insight emerges.

59 BASIC BIOLOGICAL SCIENCES↗

Production of high fluence laser beams using ion wave plasma optics

Optical components for laser beams with high peak and averaged powers are being developed worldwide using stimulated plasma scattering that occurs when plasmas interact with intense, coherent light. After decades of pursuit of pulse compressors, mirrors, and other plasma based components that can be created by stimulated scattering from electron density perturbations forming on ultra-short time scales (e.g., via Stimulated Raman Scattering), more recent work has produced optical components on longer time scales allowing ion motion as well [via Stimulated Brillouin Scattering (SBS)]. In the most recent work, ion wave plasma optics have had success in producing pulses of focusable coherent light with high energy and fluence by operating on ns time scales and now promise to enable numerous applications. Experiments have further shown that in some parameter regimes, even simple plasma response models can describe the output of such optics with sufficient accuracy that they can be used as engineering tools to design plasma optics for future applications, as is already being done to control power deposition in fusion targets. In addition, the development of more sophisticated models promises to enable still higher performance from SBS driven plasma optical components under a wider range of conditions. The present status and most promising directions for future development of ion wave plasma optic techniques are discussed here.

47 OTHER INSTRUMENTATION↗

Establishing the Quality Assurance programme for the strip sensor production of the ATLAS tracker upgrade including irradiation with neutrons, photons and protons to HL-LHC fluences

The successful pre-production delivery of strip sensors for the new Inner Tracker (ITk) for the upgraded ATLAS detector at the High Luminosity LHC (HL-LHC) at CERN was completed and based on their performance full production has commenced. The overall delivery period is anticipated to last 4 years to complete the approximately 22000 sensors required for the ITk. For Quality Assurance (QA), a number of test structures designed by the collaboration, along with a large area diode and miniature version of the main sensor, are produced in every wafer by the foundry Hamamatsu Photonics K.K (HPK). As well as Quality Control (QC) checks on every main sensor, samples of the QA pieces from each delivery batch are tested both before and after irradiation with results after exposure to neutrons, gammas or protons to fluences and doses corresponding to those anticipated after operation at the HL-LHC to roughly 1.5 times the ultimate integrated luminosity of 4000 fb -1 . In this paper the procedures are presented and the studies carried out to establish that the seven ITk QA Strip Sensor irradiation and test sites meet all the requirements to support this very extensive programme throughout the strip sensor production phase for the ITk project.

47 OTHER INSTRUMENTATION↗

Investigation of low gain avalanche detectors exposed to proton fluences beyond 10 15 n eq cm -2

Abstract Low gain avalanche detectors (LGADs) deliver excellent timing resolution, which can mitigate mis-assignment of vertices associated with pileup at the High Luminosity LHC and other future hadron colliders. The most highly irradiated LGADs will be subject to 2.5 × 10 15 n eq cm -2 of hadronic fluence during HL-LHC operation; their performance must tolerate this. Hamamatsu Photonics K.K. and Fondazione Bruno Kessler LGADs have been irradiated with 400 and 500 MeV protons respectively in several steps up to 1.5 × 10 15 n eq cm -2 . Measurements of the acceptor removal constants of the gain layers, evolution of the timing resolution and charge collection with damage, and inter-channel isolation characteristics, for a variety of design options, are presented here.

Instruments & Instrumentation↗

Constraints on cosmological parameters from gamma-ray burst peak photon energy and bolometric fluence measurements and other data

ABSTRACT We use measurements of the peak photon energy and bolometric fluence of 119 gamma-ray bursts (GRBs) extending over the redshift range of 0.3399 ≤ z ≤ 8.2 to simultaneously determine cosmological and Amati relation parameters in six different cosmological models. The resulting Amati relation parameters are almost identical in all six cosmological models, thus validating the use of the Amati relation in standardizing these GRBs. The GRB data cosmological parameter constraints are consistent with, but significantly less restrictive than, those obtained from a joint analysis of baryon acoustic oscillation and Hubble parameter measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Methods for Continuously Resolving Spectral Shifts in Distributed Optical Fiber Sensors Irradiated to Extreme Neutron Fluence

Optical frequency domain reflectometry (OFDR) is a technique for interrogating distributed optical fiber sensors (DOFS) and involves correlating changes in the Rayleigh backscatter fingerprint for a fiber under test (FUT) with a reference measurement. Recently, under the WIRE-21 experiment sponsored by Nuclear Science User Facilities (NSUF) and performed at the High-Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL), silica optical fibers were irradiated to a fast neutron fluence of 1x10^21 n/cm^2/s at temperatures from 200--400 C. As in the cases of high-temperature and high-strain conditions, such high levels of neutron bombardment result in a highly dynamic RBS that evades analysis with conventional methods. This work describes the further development and application of graphical signal processing techniques applied to OFDR-based distributed optical fiber sensors specifically deployed in in-pile applications. While the signal processing techniques developed in this work are applied to DOFS in nuclear environments, they provide a general framework for the analysis of OFDR measurements and a tangible method to yield higher quality data, without imposing additional hardware requirements.

Sweeney, Dan↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 167A

This report contains the thermal (2200 m/s) and fast (E>1 MeV) neutron fluence rate data for ATR Cycle 167A which were measure by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurement Works Order.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A MP-2 (Rev. 1)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A MP-2 which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A SR which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A MP-2

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A MP-2 which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thernal and Fast Neutron Fluence Rates ATR Cycles 171B MP-2 (Rev. 0)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171B AFC (Rev. 0)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗