Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluid Shifts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Novel Geochemistry Determined from High Pressure, High Temperature Simulation Experiments of Hydraulic Fracture Test Site 2

A standard method in unconventional oil and gas production is the process of hydraulic fracturing followed by a shut-in period, during which the fracture fluid remains pressurized in the reservoir for up to three weeks before production begins. Despite this widely used process, very little is known about what occurs in the reservoir during this shut-in process. In order to properly delineate potential reservoir reactions that may occur during shut-in that would lead to corrosion and scaling events, experiments were conducted in high pressure, high temperature reactors to simulate conditions of the Wolfcamp Formation in the Delaware Basin. Experimental design allowed the assessment of the effect of proppant, microbiology, and time on the mineralogy and fluid chemistry in the reservoir. Results suggest the biggest impact on fluid chemistry and shale mineralogy during shut-in is time. Analyses demonstrate dissolution of the shale material, with maximum dissolved ions occurring after 7 days of the shut-in period. After 21 days, results suggest precipitation occurs. The Delaware Basin is demonstrated to be high in sulfate content, which further increases in the fluid due to dissolution reactions during shut-in. The pressure vessel experiments suggest there was no significant contribution to reactions from microbiology during the shut-in period. Furthermore, early production samples demonstrate a significant selection of the microorganism Caminicella, a genus of which has previously been correlated to corrosion and sulfide production. Results suggest shut-in conditions may provide high sulfate concentrations that could later be utilized by a shifted microbial community to drive potential well infrastructure failure. This is the first study to incorporate microbiology, mineralogy, and fluid chemistry to investigate the fundamental geochemical reactions that occur during shut-in and early phase production of the Delaware Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/2-21URTC/D021S032R001/2477425/urtec-2021-5219-ms.pdf/1 by Carol Worster on 28 February 2022 Basin. Results from this study can complement observations from the Hydraulic Fracture Test Site 2 observations

58 GEOSCIENCES↗

Temperature and CO 2 interactively drive shifts in the compositional and functional structure of peatland protist communities

Microbes affect the global carbon cycle that influences climate change and are in turn influenced by environmental change. Here, we use data from a long-term whole-ecosystem warming experiment at a boreal peatland to answer how temperature and CO 2 jointly influence communities of abundant, diverse, yet poorly understood, non-fungi microbial Eukaryotes (protists). These microbes influence ecosystem function directly through photosynthesis and respiration, and indirectly, through predation on decomposers (bacteria and fungi). Using a combination of high-throughput fluid imaging and 18S amplicon sequencing, we report large climate-induced, community-wide shifts in the community functional composition of these microbes (size, shape, and metabolism) that could alter overall function in peatlands. Importantly, we demonstrate a taxonomic convergence but a functional divergence in response to warming and elevated CO 2 with most environmental responses being contingent on organismal size: warming effects on functional composition are reversed by elevated CO 2 and amplified in larger microbes but not smaller ones. Furthermore, these findings show how the interactive effects of warming and rising CO 2 levels could alter the structure and function of peatland microbial food webs—a fragile ecosystem that stores upwards of 25% of all terrestrial carbon and is increasingly threatened by human exploitation.

54 ENVIRONMENTAL SCIENCES↗

Multi-fluid, earth battery energy systems and methods

The present disclosure relates to a system for storing and time shifting at least one of excess electrical power from an electrical power grid, excess electrical power from the power plant itself, or heat from a heat generating source, in the form of pressure and heat, for future use in assisting with a production of electricity. An oxy-combustion furnace is powered by a combustible fuel source, plus excess electricity, during a charge operation to heat a reservoir system containing a quantity of a thermal storage medium. During a discharge operation, a discharge subsystem has a heat exchanger which receives heated CO 2 from the reservoir system and uses this to heat a quantity of high-pressure, supercritical CO 2 (sCO 2 ) to form very-high-temperature, high-pressure sCO 2 at a first output thereof. The very-high-temperature, high-pressure sCO 2 is used to drive a Brayton-cycle turbine, which generates electricity at a first output thereof for transmission to a power grid. The Brayton-cycle turbine also outputs a quantity of sCO 2 which is reduced in temperature and pressure to a heat recuperator subsystem. The heat recuperator subsystem circulates the sCO 2 and re-heats and re-pressurizes the sCO 2 before feeding it back to the heat exchanger to be even further reheated, and then output to the Brayton-cycle turbine as a new quantity of very-high-temperature, high-pressure sCO 2 , to assist in powering the Brayton-cycle turbine.

Buschek, Thomas A.↗

On multidomain multiscale modeling and simulation of a novel partial pressure and temperature swing adsorptive reactor ($\mathrm{PPTSAR}$) with application to the water gas shift reaction

Here in this work, a dynamic, multidomain, multiscale model of a novel Partial Pressure and Temperature Swing Adsorptive Reactor (PPTSAR) Process is developed and simulated for a Water Gas Shift Reaction (WGSR) application. The proposed model couples the reactor wall, catalyst/adsorbent pellet, and fluid mixture domains at their respective scales to comprehensively model mass, momentum, and energy transport phenomena occurring within each domain. The resulting model elucidates the PPTSAR’s start-up, transient, and long-term, periodic, dynamic behavior, during both adsorption/reaction and desorption operating modes. In the WGSR application considered, the use of two PPTSARs is shown to allow continuous operation that delivers CO conversion greater than 95% with simultaneous complete CO 2 capture.

42 ENGINEERING↗

Time-Domain Nuclear Magnetic Resonance Determination of Wettability Alteration: Analysis for Low-Salinity Water

Wettability has been shown to influence oil recovery. This property has become central to low-salinity (LSW) and smart (SWF) water flooding recovery mechanisms research. The challenge lies in the fact that oil recovery results from the combined effects of solid-liquid and liquid-liquid interactions. This demands methods that allow an independent interpretation of wettability alteration contributions. The primary objective of this work is to assess changes in wettability through the application of Time-Domain Nuclear Magnetic Resonance (TD-NMR) T 2 distribution and diffusion coefficient, starting with a well-controlled porous system, that is, glass beads, and then a model rock (Berea), in the presence of one phase, either oil or brine exclusively. Subsequently, two-phase fluid saturation was tested. For the glass beads, dimethyldichlorosilane was used to induce a hydrophobic response, as confirmed by contact angle experiments on slides of the same material. Sodium sulfate was used for its known positive influence on oil recovery during LSW and SWF. In cases where alteration of surface properties was expected, a leftward shift of the average T 2 distribution curve modes, accompanied by a reduction on the diffusion coefficient during the aging process was observed. The results of this work confirm that fluid-solid interactions during LSW and SWF, namely a shift in wettability, take place after the injection of low-salinity water.

42 ENGINEERING↗

The evolution of seafloor venting from hydrate-sealed gas reservoirs

Here we use 3D seismic data to show that three rows of seafloor gas mounds can be traced downward to leak points that lie at the hydrate-gas contact within three individual dipping coarse-grained sand bodies in the Terrebonne Basin, Walker Ridge block 313, northern Gulf of Mexico. We predict the overpressure within the sand bodies by assuming that the gas pressure at the vent points equal the least principal stress. We interpret that free gas accumulates at the base of the hydrate stability zone, trapped by the overlying sand which has a high methane hydrate saturation. The free gas accumulates until the gas pressure at the base of the hydrate stability zone reaches the least principal stress in the overlying mudrock, whereupon hydraulic fractures form and fluids are vented to the surface. The warm rising fluids and perhaps localized exothermic formation of hydrate raise the local salinity and temperature. This process progressively shifts the base of the hydrate stability zone to shallower depths and dissociates the hydrate seal within the sand, which creates new leak points and results in the observed migration of the seafloor vents. Within the southwest corner of the Terrebonne Basin, this process has repeated multiple times within the Blue, Orange, and Green sands. Here this study shows how the hydrate stability zone can influence the location of fluid expulsion and in turn be affected by the warm, rising, saline fluids sealed by hydrate.

58 GEOSCIENCES↗

Assessing the fidelity of shallow-water carbonates as records of the Ni isotope composition of surface seawater

Nickel is a bioessential metal that is used in enzymes important to the C, N, and O cycles, and changes in its marine abundance and bioavailability may have affected the evolutionary trajectory of early life. Changes over time in the Ni isotope composition (δ 60 Ni) of surface seawater, which reflects biological demand for Ni, could allow for the reconstruction of the dynamics of Ni demand over Earth’s history, but this approach would require geologic records of surface seawater. Here, we investigate the fidelity of shallow-water carbonates as a record of the Ni isotope composition of surface seawater by determining how Ni is first partitioned into natural carbonates and then how post-depositional processes influence the Ni signal. Our samples come from the Great Bahama Bank, which is a well-studied, modern carbonate platform often used to study ancient platforms. We found that Ni is fractionated from seawater upon incorporation into carbonates capturing shallow (<18 cm), recent deposition (0.1 ‰–0.4 ‰ lighter than seawater). Variation among these [Ni] and δ 60 Ni values may be controlled by variation in mineral proportions. Meteoric diagenesis shifts δ 60 Ni to lower values, which we attribute to isotopically light meteoric fluids. In contrast, carbonates that experienced sediment-buffered marine diagenesis with respect to Ca isotopes and Sr/Ca ratios do not appear to differ in δ 60 Ni values from sediments generally representative of their initial deposition. The sensitivity of δ 60 Ni to diagenetic reset in these samples appears comparable to the sensitivities of Ca isotopes and Sr/Ca ratios, to first order. Thus, in general, carbonates that experienced sediment-buffered marine diagenesis with respect to these elements may hold the most promise as a record of the δ 60 Ni of coeval surface seawater. Additionally, we use our results to infer that the fraction of Ni removed from seawater into carbonates is less than 10 % of the total Ni output from the global oceans and incorporation of this Ni sink into global biogeochemical models will only have a minor impact on the modeled modern Ni budget.

Great Bahama Bank carbonates↗

A weighted Shifted Boundary Method for free surface flow problems

The Shifted Boundary Method (SBM) belongs to the class of unfitted (or immersed, or embedded) finite element methods and was recently introduced for the Poisson, linear advection/diffusion, Stokes, Navier-Stokes, acoustics, and shallow-water equations. By reformulating the original boundary value problem over a surrogate (approximate) computational domain, the SBM avoids integration over cut cells and the associated problematic issues regarding numerical stability and matrix conditioning. Accuracy is maintained by modifying the original boundary conditions using Taylor expansions. Hence the name of the method, that shifts the location and values of the boundary conditions. In this article, we extend the SBM to the simulation of incompressible Navier-Stokes flows with moving free-surfaces, by appropriately weighting its variational form with the elemental volume fraction of active fluid. This approach prevents spurious pressure oscillations in time, which would otherwise be produced if the total active fluid volume were to change abruptly over a time step. In fact, the proposed weighted SBM method induces small mass (i.e., volume) conservation errors, which converge quadratically in the case of piecewise-linear finite element interpolations, as the grid is refined. Finally, we present an extensive set of two- and three-dimensional tests to demonstrate the robustness and accuracy of the method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel Geochemistry Determined from High P-T Simulation Experiments of HFTS 2

A standard method in unconventional oil and gas production is the process of hydraulic fracturing followed by a shut-in period, during which the fracture fluid remains pressurized in the reservoir for up to three weeks before production begins. Despite this widely used process, very little is known about what occurs in the reservoir during this shut-in process. In order to properly delineate potential reservoir reactions that may occur during shut-in that would lead to corrosion and scaling events, experiments were conducted in high pressure, high temperature reactors to simulate conditions of the Wolfcamp Formation in the Delaware Basin. Experimental design allowed the assessment of the effect of proppant, microbiology, and time on the mineralogy and fluid chemistry in the reservoir. Results suggest the biggest impact on fluid chemistry and shale mineralogy during shut-in is time. Analyses demonstrate dissolution of the shale material, with maximum dissolved ions occurring after 7 days of the shut-in period. After 21 days, results suggest precipitation occurs. The Delaware Basin is demonstrated to be high in sulfate content, which further increases in the fluid due to dissolution reactions during shut-in. The pressure vessel experiments suggest there was no significant contribution to reactions from microbiology during the shut-in period. However, early production samples demonstrate a significant selection of the microorganism Caminicella, a genus of which has previously been correlated to corrosion and sulfide production. Results suggest shut-in conditions may provide high sulfate concentrations that could later be utilized by a shifted microbial community to drive potential well infrastructure failure. This is the first study to incorporate microbiology, mineralogy, and fluid chemistry to investigate the fundamental geochemical reactions that occur during shut-in and early phase production of the Delaware Basin. Results from this study can complement observations from the Hydraulic Fracture Test Site 2 observations.

Gulliver, Djuna↗

Oxygen isotope evidence for input of magmatic fluids and precipitation of Au-Ag-tellurides in an otherwise ordinary adularia-sericite epithermal system in NE China

Abstract Tellurium-rich (Te) adularia-sericite epithermal Au-Ag deposits are an important current and future source of precious and critical metals. However, the source and evolution of ore-forming fluids in these deposits are masked by traditional bulk analysis of quartz oxygen isotope ratios that homogenize fine-scale textures and growth zones. To advance understanding of the source of Te and precious metals, herein, we use petrographic and cathodoluminescence (CL) images of such textures and growth zones to guide high spatial resolution secondary ion mass spectroscopy (SIMS) oxygen isotope analyses (10 µm spot) and spatially correlated fluid inclusion microthermometric measurements on successive quartz bands in contemporary Te-rich and Te-poor adularia-sericite (-quartz) epithermal Au-Ag vein deposits in northeastern China. The results show that large positive oxygen isotope shifts from –7.1 to +7.7‰ in quartz rims are followed by precipitation of Au-Ag telluride minerals in the Te-rich deposit, whereas small oxygen isotope shifts of only 4‰ (–2.2 to +1.6‰) were detected in quartz associated with Au-Ag minerals in the Te-poor deposits. Moreover, fluid-inclusion homogenization temperatures are higher in comb quartz rims (avg. 266.4 to 277.5 °C) followed by Au-Ag telluride minerals than in previous stages (~250 °C) in the Te-rich deposit. The Te-poor deposit has a consistent temperature (~245 °C) in quartz that pre- and postdates Au-Ag minerals. Together, the coupled increase in oxygen isotope ratios and homogenization temperatures followed by precipitation of Au-Ag tellurides strongly supports that inputs of magmatic fluid containing Au, Ag, and Te into barren meteoric water-dominated flow systems are critical to the formation of Te-rich adularia-sericite epithermal Au-Ag deposits. In contrast, Te-poor adularia-sericite epithermal Au-Ag deposits show little or no oxygen isotope or fluid-inclusion evidence for inputs of magmatic fluid.

Geochemistry & Geophysics↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

Demonstration of Microwave Resonant Cavity Transducer Performance in Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TEM 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fluid-like shock compression of dilute polymer nanocomposites

The shock Hugoniot of heterogenous mixtures of discrete particles has been experimentally investigated for porous agglomerates and fluids, while the study of full-density solids has been primarily limited to compressed powders and high-dimensional composites. By dispersing ceria nanoparticles in a polyethylene matrix, we are able to examine the hydrodynamic behavior of a nonporous, heterogenous solid in thermal equilibrium during weak shock compression. Phase-driven discontinuities in the Hugoniot particle velocity–shock velocity (u−D) relationship of pure polyethylene are replicated in the nanocomposites but are shifted to lower velocity and to higher pressure with higher particle concentration. The results are explained using an isothermal, two-velocity fluid model under the hydrodynamic approximation. The model, which assumes a theoretical equation-of-state for ceria and either a low-order or high-order fit to the measured polyethylene Hugoniot, reasonably predicts the Hugoniot for two different polyethylene/ceria nanocomposites. Using the model, the mixture Hugoniot is shown to be insensitive to the Hugoniot of the stiffer constituent when the moduli are sufficiently disparate, while dependence on particle density and volume fraction is preserved through fluid-like motion.

Moore, Nathan W. [Sandia National Laboratories (SN↗

Bridging confined phase behavior of CH 4 -CO 2 binary systems across scales

Phase behavior of confined fluids may deviate significantly from that of the bulk fluid due to the fluid-wall interactions being a significant portion of all intermolecular interactions under confinement. Despite recent advancements in understanding confined phase behavior of pure fluids, confined phase behavior of mixtures remains an understudied topic. In this work, we examine the confined phase behavior of a CH 4 -CO 2 binary system by combining Monte Carlo (MC) simulations, a cubic equation of state (EoS), and the lattice Boltzmann method (LBM). First, the effects of confinement on density and phase distribution in nano-size pores are established using Gibbs Ensemble MC calculations, which produce precise results of liquid and vapor confined pressures and account for the modification of the phase change location. By comparing the phase envelopes of bulk and confined mixtures at a fixed temperature, here it is observed that the phase envelopes shrink with reductions in pore size. Based on this observation, we extend a modified Peng-Robinson EoS, which was originally developed for pure fluids under confinement, to mixtures via van-der-Waals-type mixing rules and by accounting for shifts in the critical properties of confined CH 4 -CO 2 . The resulting phase envelopes are in good agreement with the MC data. In addition, a local density model is used in combination with the confined EoS to calculate adsorption isotherms of CH 4 -CO 2 mixtures and to characterize the behavior of confined matter in nanopores. Finally, we incorporate this EoS in a multicomponent multiphase LBM that uses a pseudopotential model to represent intermolecular forces. This workflow utilizes multiscale simulation techniques to bridge the behavior of multicomponent systems across scales and to shed light on the confined phase behavior of CH 4 -CO 2 binary systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An alternative electrode design for accurate spectral induced polarization measurements in variably saturated porous media

SUMMARY Applications of spectral induced polarization (SIP) require electrodes that maintain hydrologic contact with surrounding soils to capture small electrical responses, often observed as phase shifts in milliradians. For unsaturated soils, electrodes must overcome increased electrical contact impedance due to reduced pore fluid. Traditional designs use a ceramic membrane electrode (CME) with a water reservoir and metal conductor, requiring periodic maintenance to retain electrolytic solution. For field applications where maintenance is impractical, alternative designs are needed. This study evaluated a new electrode design (silica flour electrode, SFE) alongside a CME. SFEs use packed silica flour to store water via capillary forces against a metal conductor. This study examined both designs in three variably saturated soils at soil suctions up to 700 mbar and soil water contents below 1 percent, with SIP measurements across 0.01 to 10 000 Hz frequencies. SFEs match CMEs at high frequencies and perform better at lower frequencies, without requiring ongoing maintenance, making them ideal for field use. In water-only experiments, CMEs produced errors and high noise below 1.5 Hz, whereas SFEs were more accurate. However, CMEs performed better above 300 Hz. In fine sand, SFEs performed better due to the relatively lower contact impedance as compared to CMEs. Both electrode types performed comparably in silty sand and silt loam soils, although CMEs required ongoing maintenance, suggesting potential for long-term reliability issues.

58 GEOSCIENCES↗

Comprehensive single-shot biophysical cytometry using simultaneous quantitative phase imaging and Brillouin spectroscopy

Abstract Single-cell analysis, or cytometry, is a ubiquitous tool in the biomedical sciences. Whereas most cytometers use fluorescent probes to ascertain the presence or absence of targeted molecules, biophysical parameters such as the cell density, refractive index, and viscosity are difficult to obtain. In this work, we combine two complementary techniques—quantitative phase imaging and Brillouin spectroscopy—into a label-free image cytometry platform capable of measuring more than a dozen biophysical properties of individual cells simultaneously. Using a geometric simplification linked to freshly plated cells, we can acquire the cellular diameter, volume, refractive index, mass density, non-aqueous mass, fluid volume, dry volume, the fractional water content of cells, both by mass and by volume, the Brillouin shift, Brillouin linewidth, longitudinal modulus, longitudinal viscosity, the loss modulus, and the loss tangent, all from a single acquisition, and with no assumptions of underlying parameters. Our methods are validated across three cell populations, including a control population of CHO-K1 cells, cells exposed to tubulin-disrupting nocodazole, and cells under hypoosmotic shock. Our system will unlock new avenues of research in biophysics, cell biology, and medicine.

Steelman, Zachary A.↗

CO 2 induced changes in Mount Simon sandstone: Understanding links to post CO 2 injection monitoring, seismicity, and reservoir integrity

The purpose of this study is to quantify geochemical reactions of CO 2 and brine with subsurface samples taken from the Mt. Simon sandstone and identify any potential alterations of the geomechanical rock properties that could lead to changes observable in seismic monitoring or result in changes of micro seismicity such as those observed at the Illinois Basin-Decatur Project (IBDP) site. Two Mt. Simon sandstone samples from 6919.3 feet (2109.0 m) and 6926.1 feet (2111.1 m) depth were exposed to supercritical CO 2 (scCO 2 ) dissolved in brine at in-situ reservoir conditions for one month. Geochemical, spectral, scanning electron microscopy, and petrophysical methods were used to analyze the samples before and after the one-month exposure. Significant changes were observed. Multiple geomechanical properties were chosen to form the framework against which to interrogate the petrophysical data: Young’s modulus (E), Poisson’s ratio (ν), lambda·rho (λρ), and mu·rho (μρ). In this study we conclude that framework composition, porosity, heterogeneities, effective pressure, and reactive geochemistry are first order controls on trends in the E-μ and λρ-μρ cross plot spaces. Changes in porosity, permeability, dynamic moduli, and brittleness with exposure to these fluids were observed. No change in ultrasonic P-wave attenuation (Q P ) was observed. Geochemical alteration causes a distinct shift in λρ-μρ in both samples as well as changes in E, ν, and P and S wave seismic velocity values. Furthermore, these observations could provide insight into subsurface monitoring using seismic methods including amplitude variation with offset (AVO) classification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗