Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Fluidic Oscillator Having Decoupled Frequency and Amplitude Control

A fluidic oscillator having independent frequency and amplitude control includes a fluidic-oscillator main flow channel having a main flow inlet, a main flow outlet, and first and second control ports disposed at opposing sides thereof. A fluidic-oscillator controller has an inlet and outlet. A volume defined by the main flow channel is greater than the volume defined by the controller. A flow diverter coupled to the outlet of the controller defines a first fluid flow path from the controller's outlet to the first control port and defines a second fluid flow path from the controller's outlet to the second control port.

Koklu, Mehti↗

Topology optimization of additively manufactured fluidic components free of internal support structures

This report integrates projection-based approaches for implementing overhang constraints with fluid topology optimization to design additively manufactured fluidic components that do not require internal support structures. Internal support structures are challenging, potentially impossible to remove in complex fluid networks, yet would degrade fluidic performance if left within the part. This presents a major challenge in coupling topology optimization with additive manufacturing in the design of fluid components. The proposed approach leverages past work in overhang constraints for solid mechanics, including projection formulations and adjoint sensitivity analysis, and considers incompressible Navier–Stokes equations for laminar fluid flow. The approach is demonstrated on 2D and 3D fluid topology optimization problems to minimize pressure drop and constrain mass flow rates in pipes and manifolds. Resulting designs are crisp, logical, satisfy performance constraints, and satisfy overhang constraints, eliminating the need for internal support structures.

42 ENGINEERING↗

Hierarchical Composites Patterned via 3D Printed Cellular Fluidics

Additive manufacturing of freeform structures containing multiple materials with deterministic spatial arrangement and interactions remains a challenge for most 3D printing processes, due to complex fabrication tool requirements and limitations in printability of some material classes. Here, in this paper, a versatile method is reported to produce architected composites using the concept of cellular fluidics, in which lattices of unit cells are used as templating scaffolds to guide flowable infill materials in a programmed spatial pattern, upon which they are cured in place to produce a deterministically ordered multimaterial solid. The lattice design relies on the unit cell size, type, strut diameter, surface wetting, and distribution of cellular structures to control liquid flow and retention. Individual unit cells are tuned to achieve reliable infilling and combined into higher-order architectures to achieve multiscale composite materials with disparate mechanical properties, including those considered non-printable. Lattice design considerations for leveraging capillary phenomena and demonstrate several methods of patterning polymers in 3D-printed cellular fluidic structures are presented. The concept of tuning the compressive response of an architected composite using a flexible-elastomer as the lattice and a stiff-epoxy as the infill material is illustrated.

36 MATERIALS SCIENCE↗

Highly Rectifying Fluidic Diodes Based on Asymmetric Layer-by-Layer Nanofilms on Nanochannel Membranes

Nanochannel-based fluidic diodes display ion selectivity and ion-current rectification (ICR), which may prove important in energy harvesting and biosensors. This paper reports asymmetric functionalization of the outer surface of a flexible nanochannel polymer membrane to create fluidic diodes that give ICR. Layer-by-layer (LbL) adsorption with cross-linking of only the underlying part of the polyelectrolyte nanofilm leads to a porosity step across the film. The combination of a high effective surface-charge density and the porosity step in the film leads to a remarkable maximum ICR factor of ~200 with a pH gradient across the film. Incorporation of pH-sensitive polyelectrolyte components enables the ICR factor to increase an order of magnitude on going from pH 8 to pH 3. Furthermore, the coated membrane shows excellent anion-selectivity. Thus, LbL adsorption with partial cross-linking provides a simple method for creating coated nanochannel membranes that serve as pH-responsive ionic diodes for potential chemical/biosensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational Characterization and Boundary Condition Models of a Jet Interaction Fluidic Oscillator

Fluidically oscillating jet actuators that generate sweeping jets when supplied with a pressurized fluid have been used to mitigate separation and reduce drag in a range of flow control applications. Their implementation in future flight vehicles would require fundamental understanding and accurate predictive techniques of the physics of their internal flow and jet formation. The present investigations focus on high-fidelity, time-accurate simulations to characterize the flow physics of the actuator in quiescent conditions. An important element of the present simulations is to demonstrate the ability of the computational fluid dynamics (CFD) solver to predict the jet characteristics and provide a basis for the development of improved boundary conditions (BC) without entirely resolving the geometrical features of the fluidic device. The CFD-predicted oscillation frequencies of the engendered jets were found to be in excellent agreement with experiments, even on two-dimensional meshes. The study revealed that three-dimensional simulations are required to capture some of the flow features of the sweeping jet such as the double peak in time-averaged velocity distributions downstream of the actuator’s orifice that were measured in experiments. Furthermore, several approaches for modeling the actuator were implemented and assessed in quiescent conditions. The evaluation of a boundary condition at the device throat, based on the phase-averaged flow variables, provides the basis for devising surface-based boundary conditions. The influence and necessity of including turbulent characteristics as part of the boundary conditions have also been identified.

42 ENGINEERING↗

Fluidic-thermochromic display device

Fluidic decoder and display device has low-power requirements for temperature control of thermochromic materials. An electro-to-fluid converter translates incoming electrical signals into pneumatics signal of sufficient power to operate the fluidic logic elements.

Grafstein, D.↗

Fluidic displays

Fluidic display, discussing applications for fluidic computers and control systems

Van Der Heyden, J.↗

Fluidic Ignition Detection

Ignition sensor, utilizing fluidic oscillator device and its ability to react to flow system's molecular weight and temperature changes, detects propellant ignition. Commercial applications include fields of fire protection equipment and fluidics.

Henry, C. S.↗

Fluidic pressure regulators

Three basic areas for possible application of fluidic control to rocket engine subsystems were identified and six subsystem configurations were analyzed for study. Results provide indication of tradeoffs involved between conventional and fluidic regulators and should be of interest to control and applications engineers who need to make similar analyses.

Mangion, C.↗

Indexing film with a fluidic sensor

Fluidic sensor is used to measure passage of film without mechanical contact with counting device. Same sensor system may be used for different sizes of film. System has two fluidic sensors and operates on principle of electrically recording interruptions in air stream.

Maciel, A., Jr.↗

Development of a three axis fluidic airspeed sensor

A three axis fluidic airspeed sensor system has been fabricated and wind tunnel tested. The complete system consists of the fluidic sensor, air power supply and instrumentation and readout. The system is adapted to aircraft and requires only the standard aircraft 28V dc supply to function.

Neradka, V. F.↗

Fluidic emergency roll control system

A fluidic emergency roll control system for aircraft stabilization in the event of primary flight control failure was evaluated. The fluidic roll control units were designed to provide roll torque proportional to an electrical command as operated by two diametrically opposed thrust nozzles located in the wing tips. The control package consists of a solid propellant gas generator, two diametrically opposed vortex valve modulated thrust nozzles, and an electromagnetic torque motor. The procedures for the design, development, and performance testing of the system are described.

Haefner, K. B.↗

The feasibility of a fluidic respiratory flow meter

A study was undertaken to determine the feasibility of adapting a fluidic airspeed sensor for use as a respiratory flowmeter. A Pulmonary Function Testing Flowmeter was developed which should prove useful for mass screening applications. The fluidic sensor threshold level was not reduced sufficiently to permit its adaptation to measuring the low respiratory flow rates encountered in many respiratory disorders.

Neradka, V. F.↗

Fluidic hydrogen detector production prototype development

A hydrogen gas sensor that can replace catalytic combustion sensors used to detect leaks in the liquid hydrogen transfer systems at Kennedy Space Center was developed. A fluidic sensor concept, based on the principle that the frequency of a fluidic oscillator is proportional to the square root of the molecular weight of its operating fluid, was utilized. To minimize sensitivity to pressure and temperature fluctuations, and to make the sensor specific for hydrogen, two oscillators are used. One oscillator operates on sample gas containing hydrogen, while the other operates on sample gas with the hydrogen converted to steam. The conversion is accomplished with a small catalytic converter. The frequency difference is taken, and the hydrogen concentration computed with a simple digital processing circuit. The output from the sensor is an analog signal proportional to hydrogen content. The sensor is shown to be accurate and insensitive to severe environmental disturbances. It is also specific for hydrogen, even with large helium concentrations in the sample gas.

Roe, G. W.↗

Wind tunnel tests of the dynamic characteristics of the fluidic rudder

The fourth phase is given of a continuing program to develop the means to stabilize and control aircraft without moving parts or a separate source of power. Previous phases have demonstrated the feasibility of (1) generating adequate control forces on a standard airfoil, (2) controlling those forces with a fluidic amplifier and (3) cascading non-vented fluidic amplifiers operating on ram air supply pressure. The foremost objectives of the fourth phase covered under Part I of this report were to demonstrate a complete force-control system in a wind tunnel environment and to measure its static and dynamic control characteristics. Secondary objectives, covered under Part II, were to evaluate alternate configurations for lift control. The results demonstrate an overall response time of 150 msec, confirming this technology as a viable means for implementing low-cost reliable flight control systems.

Belsterling, C. A.↗