Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Microfluidic Uranium Microspheres Production for TRISO and Advanced Fuel Concepts

The purpose of this project was to expand existing internal gelation sol-gel capabilities at PNNL to explore producing uranium dioxide spheres for potential use as fuel kernels in next generation Tri-isotropic (TRISO) particle fuel. This project expands on previous sol-gel efforts at PNNL by (1) increasing the size regime of sphere production from the micro-fluidic range to the milli-fluidic range, and (2) producing uranium spheres. The approach involved first scaling up the channel size of the fluidic system to the millimeter range, with radiation safety considerations in mind; testing and demonstration on non-radioactive surrogate material, cerium oxide; then transitioning to uranium production and finally optimizing system parameters. Commercially available fluidic chips in the desired size range were could not be found, therefore the project designed and fabricated a T-junction with 1mm channels for droplet production. Because the production process is temperature sensitive, prior efforts have involved performing droplet production in a lab freezer. To reduce radiological waste and footprint, two alternative chilling methods were explored using aluminum thermal beads as a chill bath and a custom aluminum block fit to reagent reservoir sizes. Both were successful in the cerium tests, however the aluminum block design outperformed the thermal bead bath and was further adapted for the radiological test and production run in the Radiochemical Processing Laboratory (RPL). Gelation trials were performed to determine an acceptable range of feed solution parameters for the uranium dioxide gels, characterized by R-values, which is determined by the ratio of uranium nitrate to Hexamethylenetetramine (HMTA)/urea in the feed solution. R-values ranging from 1.6-2 were examined in the gelation trials, with only the 1.8 condition being tested in production. The project was successful in demonstrating a proof of concept design for producing uranium dioxide spheres, however further optimization is needed to dial in production parameters and improve sphere quality and homogeneity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Additively manufactured radial turbine rotor with cooling manifolds

A turbine rotor includes a base and a plurality of blades. A central nose is radially inward of the blades and defines an axis of rotation. A plurality of cooling manifolds is disposed within the turbine rotor and includes impingement cooling jets extending through a rear surface of the turbine rotor. An internal cooling manifold extends radially inward of the impingement cooling jets and extends between the base and the rear surface of the turbine rotor. A central nose cooling manifold extends into the central nose and is fluidically connected to the internal cooling manifold. A base cooling manifold is fluidically connected to the central nose manifold and extends radially outward from the central nose cooling manifold. A blade cooling manifold is fluidically connected to the base cooling manifold and extends within the blade. Trailing edge jets extend from the blade cooling manifold and through the trailing edge of blades.

Dai, Zhongtao↗

Additively manufactured radial turbine rotor with cooling manifolds

A turbine rotor includes a base and a plurality of blades. A central nose is radially inward of the blades and defines an axis of rotation. A plurality of cooling manifolds is disposed within the turbine rotor and includes impingement cooling jets extending through a rear surface of the turbine rotor. An internal cooling manifold extends radially inward of the impingement cooling jets and extends between the base and the rear surface of the turbine rotor. A central nose cooling manifold extends into the central nose and is fluidically connected to the internal cooling manifold. A base cooling manifold is fluidically connected to the central nose manifold and extends radially outward from the central nose cooling manifold. A blade cooling manifold is fluidically connected to the base cooling manifold and extends within the blade. Trailing edge jets extend from the blade cooling manifold and through the trailing edge of blades.

Dai, Zhongtao↗

Low‐Volume Cores for Fabrication of Compact, Versatile, and Intelligent Soft Systems

Abstract This study introduces the low‐volume core (LVC) fabrication method, which enables the monolithic molding of compact, complex, versatile, and intelligent soft robotic systems. This method uses thin and flexible thermoplastic sheets to mold internal chambers in soft fluidic actuators, valves, and circuits. The LVC fabrication method creates low‐volume networks in soft actuators (LV‐net actuators) that can be made with compact and complex geometries, enabling both low actuation volume input and multi‐degree‐of‐freedom actuators. LVC fabrication can also be used for compact, completely soft, and monolithic logic components (valves with low‐volume core, also called as LV valves) to provide directional resistance as well as a switching mechanism that enables fluidic logic in soft systems. The compatibility of the fabrication methods for both soft actuators and valves facilitates the creation of compact, integrated, and versatile soft robotic systems with embodied intelligence. This study introduces two examples of such intelligent soft robotic systems that integrate both LV‐net actuators and LV valves to demonstrate capability for complex system fabrication.

Yu, Qifan↗

Self‐Propelling Macroscale Sheets Powered by Enzyme Pumps

Abstract Nanoscale enzymes anchored to surfaces act as chemical pumps by converting chemical energy released from enzymatic reactions into spontaneous fluid flow that propels entrained nano‐ and microparticles. Enzymatic pumps are biocompatible, highly selective, and display unique substrate specificity. Utilizing these pumps to trigger self‐propelled motion on the macroscale has, however, constituted a significant challenge and thus prevented their adaptation in macroscopic fluidic devices and soft robotics. Using experiments and simulations, we herein show that enzymatic pumps can drive centimeter‐scale polymer sheets along directed linear paths and rotational trajectories. In these studies, the sheets are confined to the air/water interface. With the addition of appropriate substrate, the asymmetric enzymatic coating on the sheets induces chemically driven, buoyancy flows that controllably propel the sheet's motion on the air/water interface. The directionality and speed of the motion can be tailored by changing the pattern of the enzymatic coating, type of enzyme, and nature and concentration of the substrate. This work highlights the utility of biocompatible enzymes for generating motion in macroscale fluidic devices and robotics and indicates their potential utility for in vivo applications.

Song, Jiaqi↗

Self‐Propelling Macroscale Sheets Powered by Enzyme Pumps

Nanoscale enzymes anchored to surfaces act as chemical pumps by converting chemical energy released from enzymatic reactions into spontaneous fluid flow that propels entrained nano‐ and microparticles. Enzymatic pumps are biocompatible, highly selective, and display unique substrate specificity. Utilizing these pumps to trigger self‐propelled motion on the macroscale has, however, constituted a significant challenge and thus prevented their adaptation in macroscopic fluidic devices and soft robotics. Using experiments and simulations, we herein show that enzymatic pumps can drive centimeter‐scale polymer sheets along directed linear paths and rotational trajectories. In these studies, the sheets are confined to the air/water interface. With the addition of appropriate substrate, the asymmetric enzymatic coating on the sheets induces chemically driven, buoyancy flows that controllably propel the sheet's motion on the air/water interface. The directionality and speed of the motion can be tailored by changing the pattern of the enzymatic coating, type of enzyme, and nature and concentration of the substrate. This work highlights the utility of biocompatible enzymes for generating motion in macroscale fluidic devices and robotics and indicates their potential utility for in vivo applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stretchable and wearable polymeric heaters and strain sensors fabricated using liquid metals

Wearable electronic devices (WEDs) are receiving significant attention because of the increasing interest in soft robotics, electronic skin, and wearable sensors. Liquid metals (LMs) are compelling for WEDs owing to their metallic conductivity, fluidic nature, and low toxicity. For this study, we fabricated stretchable and soft WEDs using LM (eutectic gallium-indium alloy) wires (LMWs) patterned via force wetting through custom-made stencils on an elastic substrate. LMWs can generate thermal energy via Joule heating upon current application and deliver it to the substrate, resulting in wearable polymeric heaters. The LM mixed with carbonyl iron particles (CIPs) can also be patterned while preserving fluidic behavior. The degree of thermal energy generated through the LMWs can be manipulated as a function of the CIP concentration in the LM and geometrical factors of the electrode patterns, i.e., width and length. An elastic film patterned with LMWs attached to the human body exhibits changes in the effective electrical resistance depending on applied strain, demonstrating potential as a wearable strain sensor. This LM utilized WED that can generate thermal energy upon current application through the LMWs and detect the bodily motion has significant potential for application in wearable thermotherapy, electronic skin, and soft sensors.

47 OTHER INSTRUMENTATION↗

Salt Sampling FY21 Technical Report

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches to enable high-precision in-process salt sample analysis to improve the timeliness of sampling-based accountancy measurements. Tools currently under development in support of this goal include (1) a modular vacuum sampler with an accompanying sample handling method for coupling vacuum sampling with high-precision at-line sample analysis, (2) a pneumatic sample generator that enables high-throughput sample analysis to improve the precision of existing analytical techniques, and (3) a windowless flow cell to enable on-line optical analysis of molten salt in a sampling loop. Compared to point sampling approaches (i.e., dip probes), vacuum sampling systems and on-line sampling loops facilitate access to a larger cross-section of a process fluid. This is known to improve the characterization of the process fluid by producing more representative samples and by enabling the analysis of a larger cross section of the fluid. A vacuum sampling approach for molten salts eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. In FY21, two methods for integrating a vacuum sampler with a pneumatic sample generator were tested. These included direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the extreme conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampler and pneumatic sample generator, respectively. While the charging mechanism will be deployed in FY22, the tube transfer method and discharge mechanism were tested in FY21. These were deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The method was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques. This will enable significant reductions in the time delay for sampling-based accountancy measurements by eliminating the need for manual off-line sample processing and analysis. On-line optical analysis of molten salt in a sampling loop would provide complementary information to at-line and in-situ techniques. In FY21, an open-aperture molten salt gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the refinement and performance testing of the on-line and at-line sampling tools, integration of additional analysis techniques, stakeholder outreach and collaboration, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deployment of salt sample extraction system at an engineering-scale electrorefiner

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness of sampling-based accountancy measurements. Two technologies under development in support of this goal are a vacuum sampling loop module and a high-throughput pneumatic sample generator module. Compared to traditional point sampling approaches (i.e., dip probes), the vacuum sampling loop facilitates the collection of a larger cross-section of the bulk salt in order to collect more representative samples. The vacuum sampling approach also eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. The pneumatic sample generator module is used to facilitate high-throughput sample analysis to improve the measurement precision of any given analytical technique by averaging out random sampling and measurement errors. In FY21, two methods for integrating these two modules were tested including direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampling loop and pneumatic sample generator modules, respectively. While the charging mechanism will be deployed in FY22, the discharge mechanism was tested in FY21 and is described here. The solid salt tube transfer method was deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The approach was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. To discharge salt from the sample tubes at the sampler generator, tube segments were inserted directly into the sample generator’s Helmholtz chamber and pressure pulse actuations were used to generate precision molten salt samples directly from the tube segments. The direct insertion of sample tubes into the sample generator enabled rapid loading of the salt and prevented salt from contacting most of the interior surfaces of the sample generator, which eliminated cross-contamination between runs. The vacuum sampling-loop tube charging mechanism will support high-throughput tube sampling operations by employing a dynamic vacuum filling process to fill short charge tubes that are configured to be rapidly connected and disconnected from the loop. The dynamic vacuum sampling operation will be automated, and sample tube handling can be executed with simple overhead actuation. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques which will enable significant reductions in the time delay for sampling-based high-precision accountancy measurements.

42 ENGINEERING↗

Microfluidic package and method of making the same

The present invention relates to encapsulated microfluidic packages and methods thereof. In particular embodiments, the package includes a device, a cradle configured to support the device, and a lid having a bonding surface configured to provide a fluidic seal between itself and the device and/or cradle. Other package configurations, as well as methods for making such fluidic seals, are described herein.

42 ENGINEERING↗

Check valves for microfluidic systems and methods thereof

The present invention relates to microfluidic check valves, as well as fluidic cartridges including such check valves. In particular examples, the check valve includes a pre-stressed spring formed from a planar substrate. Various characteristics of the valves, such as size, profile, opening pressure, etc., can be tuned to provide desired performance when employed within a fluidic cartridge.

Ball, Cameron Scott↗

OPTIMIZATION OF A NUCLEAR VESSEL OUTLET FOR INCIDENT MONITORING

Classical nuclear core fluidic design techniques require improvement to better align with modern technological innovations. The US Department of Energy’s Office of Nuclear Energy (DOE-NE) Transformational Challenge Reactor (TCR) program is deploying additive manufacturing and advanced modeling and simulation to reimagine these designs. With the aid of modern computing power, computerized design optimization can be implemented to remove unwanted pressure drop while simultaneously optimizing flow structures, resulting in new opportunities to enable advanced instrumentation and monitoring capabilities.Previous development of geometric specifications for the TCR pressure vessel’s outlet plenum used design optimization to (1) limit pressure losses below 3.5 kPa (~0.5 psi) and (2) create a fluidic plane in which the temperature variation would not exceed ±5°C. This significant limit of the allowable pressure drop stems from the overarching goal of the TCR program to apply cutting edge techniques and unconventional thinking to demonstrate potential opportunities in additive manufacturing (AM).This paper expands the previous work by optimizing thermowell locations for robust measurements by explicitly modeling them and the resulting flow impacts. Additionally, a single core coolant channel was chosen to represent an event that causes an increased bulk flow temperature increase of 100°C.High fidelity unsteady Reynolds-averaged Navier-Stokes (URANS) simulations of the conjugate heat transfer problem were run in Siemen’s Star-CCM+ for this study. Next, the bulk flow temperature of a single coolant channel was increased by 100°C and was allowed to converge again. Finally, statistical analysis using a sequential probability ratio test (SPRT) was used to determine the elapsed time the thermocouples took to discover the increased bulk flow temperature.

See, Nate↗

Flow-through electrode capacitive deionization cell

Disclosed here is a capacitive deionization device for removing ions from a target solution. The capacitive deionization device includes a first porous electrode, a second porous electrode, a first header plate, a second header plate, and a sealant. The second porous electrode is disposed below and spaced from the first porous electrode. The first header plate is disposed on the first porous electrode. The first header plate defines an input flow channel that is in fluidic communication with the first porous electrode. The second header plate is disposed below the second porous electrode. The second header plate defines an output flow channel that is in fluidic communication with the second porous electrode. The sealant is disposed between the first header plate and the second header plate and surrounds the first porous electrode and the second porous electrode.

Campbell, Patrick G.↗

Composition and method for capture and degradation of PFAS

Materials for binding per- and polyfluoroalkyl substances (PFAS) are disclosed. A fluidic device comprising the materials for detection and quantification of PFAS in a sample is disclosed. The fluidic device may be configured for multiplexed analyses. Also disclosed are methods for sorbing and remediating PFAS in a sample. The sample may be groundwater containing, or suspected of containing, one or more PFAS.

Motkuri, Radha K.↗

Microfluidic package and method of making the same

The present invention relates to encapsulated microfluidic packages and methods thereof. In particular embodiments, the package includes a device, a cradle configured to support the device, and a lid having a bonding surface configured to provide a fluidic seal between itself and the device and/or cradle. Other package configurations, as well as methods for making such fluidic seals, are described herein.

Branch, Darren W.↗

Gas sensor system

A gas sensing tube includes an outer surface, and an inner surface defining a passage. A sensor node is arranged along the sensing tube. The sensor node includes an inlet fluidically connected to the passage, an outlet fluidically connected to the passage, and an interior chamber arranged between the inlet and the outlet. A sensor cable extends along the sensing tube. The sensor cable includes a first conduit having a first connector coupled to the sensor node at the inlet and a second conduit having a second connector connected to the sensor node at the outlet. The sensor cable has a first conductor extending through the first conduit and being coupled to the first connector and a second conductor extending through the second conduit and being coupled to the second connector.

Challener, William Albert↗

Multi-spool CO2 aircraft power system for operating multiple generators

A CO 2 bottoming cycle system includes a first compressor operatively connected to a first turbine through a first shaft. A first generator is operatively connected to the first shaft. A second compressor is fluidically connected to the first compressor. The second compressor is operatively connected to a second turbine through a second shaft. A second generator is operatively connected to the second shaft. The first turbine is fluidically connected to the second turbine.

Taylor, Stephen H.↗