Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluorescent Dyes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Plasmodesmal-mediated cell-to-cell transport in wheat roots is modulated by anaerobic stress

Cell-to-cell transport of small molecules and ions occurs in plants through plasmodesmata. Plant roots are frequently subjected to localized anaerobic stress, with a resultant decrease in ATP. In order to determine the effect of this stress on plasmodesmal transport, fluorescent dyes of increasing molecular weight (0.46 to 1OkDa) were injected into epidermal and cortical cells of 3-day-old wheat roots, and their movement into neighboring cells was determined by fluorescence microscopy. Anaerobiosis was generated by N2 gas or simulated by the presence of sodium azide, both of which reduced the ATP levels in the tissue by over 80%. In the absence of such stress, the upper limit for movement, or size exclusion limit (SEL), of cortical plasmodesmata was <1 kDa. The ATP analogue TNP-ADP (mw 681) moved across the plasmodesmata of unstressed roots, indicating that plasmodesmata may be conduits for nucleotide (ATP and ADP) exchange between cells. Upon imposition of stress, the SEL rose to between 5 and 10 kDa. This response of plasmodesmata to a decrease in the level of ATP suggests that they are constricted by an ATP-dependent process so as to maintain a restricted SEL. When roots are subjected to anaerobic stress, an increase in SEL may permit enhanced delivery of sugars to the affected cells of the root where anaerobic respiration could regenerate the needed ATP.

NASA Discipline Plant Biology↗

Detecting Cracks on Inner Surfaces

Microscopic cracks or flaws in surface of a workpiece are often detected with fluorescent dye. Dye is spread over surface to be inspected and then washed off. When piece is viewed under ultraviolet light, a glow is seen from dye trapped in any flaws. Intensity of fluorescence gives a rough indication of depth of defect. Fluorescent inspection procedure is fast, inexpensive and simple to perform.

Sax, A.↗

Permeation of halide anions through phospholipid bilayers occurs by the solubility-diffusion mechanism

Two alternative mechanisms are frequently used to describe ionic permeation of lipid bilayers. In the first, ions partition into the hydrophobic phase and then diffuse across (the solubility-diffusion mechanism). The second mechanism assumes that ions traverse the bilayer through transient hydrophilic defects caused by thermal fluctuations (the pore mechanism). The theoretical predictions made by both models were tested for halide anions by measuring the permeability coefficients for chloride, bromide, and iodide as a function of bilayer thickness, ionic radius, and sign of charge. To vary the bilayer thickness systematically, liposomes were prepared from monounsaturated phosphatidylcholines (PC) with chain lengths between 16 and 24 carbon atoms. The fluorescent dye MQAE (N-(ethoxycarbonylmethyl)-6-methoxyquinolinium bromide) served as an indicator for halide concentration inside the liposomes and was used to follow the kinetics of halide flux across the bilayer membranes. The observed permeability coefficients ranged from 10(-9) to 10(-7) cm/s and increased as the bilayer thickness was reduced. Bromide was found to permeate approximately six times faster than chloride through bilayers of identical thickness, and iodide permeated three to four times faster than bromide. The dependence of the halide permeability coefficients on bilayer thickness and on ionic size were consistent with permeation of hydrated ions by a solubility-diffusion mechanism rather than through transient pores. Halide permeation therefore differs from that of a monovalent cation such as potassium, which has been accounted for by a combination of the two mechanisms depending on bilayer thickness.

NASA Discipline Exobiology↗

Imaging Dot Patterns for Measuring Gossamer Space Structures

A paper describes a photogrammetric method for measuring the changing shape of a gossamer (membrane) structure deployed in outer space. Such a structure is typified by a solar sail comprising a transparent polymeric membrane aluminized on its Sun-facing side and coated black on the opposite side. Unlike some prior photogrammetric methods, this method does not require an artificial light source or the attachment of retroreflectors to the gossamer structure. In a basic version of the method, the membrane contains a fluorescent dye, and the front and back coats are removed in matching patterns of dots. The dye in the dots absorbs some sunlight and fluoresces at a longer wavelength in all directions, thereby enabling acquisition of high-contrast images from almost any viewing angle. The fluorescent dots are observed by one or more electronic camera(s) on the Sun side, the shade side, or both sides. Filters that pass the fluorescent light and suppress most of the solar spectrum are placed in front of the camera(s) to increase the contrast of the dots against the background. The dot image(s) in the camera(s) are digitized, then processed by use of commercially available photogrammetric software.

Dorrington, A. A.↗

Molecules for Fluorescence Detection of Specific Chemicals

A family of fluorescent dye molecules has been developed for use in on-off fluorescence detection of specific chemicals. By themselves, these molecules do not fluoresce. However, when exposed to certain chemical analytes in liquid or vapor forms, they do fluoresce (see figure). These compounds are amenable to fixation on or in a variety of substrates for use in fluorescence-based detection devices: they can be chemically modified to anchor them to porous or non-porous solid supports or can be incorporated into polymer films. Potential applications for these compounds include detection of chemical warfare agents, sensing of acidity or alkalinity, and fluorescent tagging of proteins in pharmaceutical research and development. These molecules could also be exploited for use as two-photon materials for photodynamic therapy in the treatment of certain cancers and other diseases. A molecule in this family consists of a fluorescent core (such as an anthracene or pyrene) attached to two end groups that, when the dye is excited by absorption of light, transfer an electron to the core, thereby quenching the fluorescence. The end groups can be engineered so that they react chemically with certain analytes. Upon reaction, electrons on the end groups are no longer available for transfer to the core and, consequently, the fluorescence from the core is no longer quenched. The chemoselectivity of these molecules can be changed by changing the end groups. For example, aniline end groups afford a capability for sensing acids or acid halides (including those contained in chemical warfare agents). Pyridine or bipyridyl end groups would enable sensing of metal ions. Other chemicals that can be selectively detected through suitable choice of end groups include glucose and proteins. Moreover, the fluorescent cores can be changed to alter light-absorption and -emission characteristics: anthracene cores fluoresce at wavelengths around 500 nm, whereas perylene cores absorb and emit at wavelengths of about 600 nm.

Fedor, Steve↗

Absolute tracer dye concentration using airborne laser-induced water Raman backscatter

The use of simultaneous airborne-laser-induced dye fluorescence and water Raman backscatter to measure the absolute concentration of an ocean-dispersed tracer dye is discussed. Theoretical considerations of the calculation of dye concentration by the numerical comparison of airborne laser-induced fluorescence spectra with laboratory spectra for known dye concentrations using the 3400/cm OH-stretch water Raman scatter as a calibration signal are presented which show that minimum errors are obtained and no data concerning water mass transmission properties are required when the laser wavelength is chosen to yield a Raman signal near the dye emission band. Results of field experiments conducted with an airborne conical scan lidar over a site in New York Bight into which rhodamine dye had been injected in a study of oil spill dispersion are then indicated which resulted in a contour map of dye concentrations, with a minimum detectable dye concentration of approximately 2 ppb by weight.

Hoge, F. E.↗

Enhancement Of Penetrant-Inspection Images

Proposed computerized video system processes images of fluorescent dyes absorbed in flaws in welds. Video camera, held by operator or by remote manipulator, views weld illuminated by visible white and ultraviolet light. Images of penetrating dye in cracks and voids in weld joint appear on video monitor. Fluorescent features enhanced by software to facilitate identification of true flaws and record important data.

Wilson, Rhonda C.↗

Concentration Measurements in a Cold Flow Model Annular Combustor Using Laser Induced Fluorescence

A nonintrusive concentration measurement method is developed for determining the concentration distribution in a complex flow field. The measurement method consists of marking a liquid flow with a water soluble fluorescent dye. The dye is excited by a two dimensional sheet of laser light. The fluorescent intensity is shown to be proportional to the relative concentration level. The fluorescent field is recorded on a video cassette recorder through a video camera. The recorded images are analyzed with image processing hardware and software to obtain intensity levels. Mean and root mean square (rms) values are calculated from these intensity levels. The method is tested on a single round turbulent jet because previous concentration measurements have been made on this configuration by other investigators. The previous results were used to comparison to qualify the current method. These comparisons showed that this method provides satisfactory results. 'Me concentration measurement system was used to measure the concentrations in the complex flow field of a model gas turbine annular combustor. The model annular combustor consists of opposing primary jets and an annular jet which discharges perpendicular to the primary jets. The mixing between the different jet flows can be visualized from the calculated mean and rms profiles. Concentration field visualization images obtained from the processing provide further qualitative information about the flow field.

Morgan, Douglas C.↗

Validation of fluorescent-labeled microspheres for measurement of relative blood flow in severely injured lungs

The aim of the study was to validate a nonradioactive method for relative blood flow measurements in severely injured lungs that avoids labor-intensive tissue processing. The use of fluorescent-labeled microspheres was compared with the standard radiolabeled-microsphere method. In seven sheep, lung injury was established by using oleic acid. Five pairs of radio- and fluorescent-labeled microspheres were injected before and after established lung injury. Across all animals, 175 pieces were selected randomly. The radioactivity of each piece was determined by using a scintillation counter. The fluorescent dye was extracted from each piece with a solvent without digestion or filtering. The fluorescence was determined with an automated fluorescent spectrophotometer. Perfusion was calculated for each piece from both the radioactivity and fluorescence and volume normalized. Correlations between flow determined by the two methods were in the range from 0.987 +/- 0.007 (SD) to 0.991 +/- 0.002 (SD) after 9 days of soaking. Thus the fluorescent microsphere technique is a valuable tool for investigating regional perfusion in severely injured lungs and can replace radioactivity.

Non-NASA Center↗

Method of Making Dye-Doped Polystyre Microparticles

Various embodiments provide dye-doped polystyrene microspheres generated using dispersion polymerization. Polystyrene microspheres may be doped with fluorescent dyes, such as xanthene derivatives including kiton red 620 (KR620), using dispersion polymerization. Certain functionalities, such as sodium styrene sulfonate, may be used to shift the equilibrium distribution of dye molecules to favor incorporation of the dye into the particles. Polyelectrolyte materials, such as poly(diallyldimethyl ammonium chloride), PolyDADMAC, may be used to electrostatically trap and bind dye molecules within the particles. A buffer may be used to stabilize the pH change of the solution during dye-doped polystyrene microsphere generation and the buffer may be selected depending on the pKa of the dye being incorporated. The various embodiments may provide dye-doped polystyrene microspheres, such as KR620-doped polystyrene microspheres that are non-toxic and non-carcinogenic. These non-toxic and non-carcinogenic dye-doped polystyrene microspheres may be suitable for use in wind tunnel testing.

Wohl, Jr., Christopher J.↗

Fluorescence-Doped Particles for Simultaneous Temperature and Velocity Imaging

Polystyrene latex microspheres (PSLs) have been used for particle image velocimetry (PIV) and laser Doppler velocimetry (LDV) measurements for several decades. With advances in laser technologies, instrumentation, and data processing, the capability to collect more information about fluid flow beyond velocity is possible using new seed materials. To provide additional measurement capability, PSLs were synthesized with temperature-sensitive fluorescent dyes incorporated within the particle. These multifunctional PSLs would have the greatest impact if they could be used in large scale facilities with minimal modification to the facilities or the existing instrumentation. Consequently, several potential dyes were identified that were amenable to existing laser systems currently utilized in wind tunnels at NASA Langley Research Center as well as other wind and fluid (water) tunnels. PSLs incorporated with Rhodamine B, dichlorofluorescein (DCF, also known as fluorescein 548 or fluorescein 27) and other dyes were synthesized and characterized for morphology and spectral properties. The resulting particles were demonstrated to exhibit fluorescent emission, which would enable determination of both fluid velocity and temperature. They also would allow near-wall velocity measurements whereas laser scatter from surfaces currently prevents near-wall measurements using undoped seed materials. Preliminary results in a wind tunnel facility located at Virginia Polytechnic Institute and State University (Virginia Tech) have verified fluorescent signal detection and temperature sensitivity of fluorophore-doped PSLs.

Danehy, Paul M.↗

FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D

Astronauts lose 1.0 to 1.5% of their bone mass per month on long-duration spaceflights. NASA wishes to monitor the bone loss onboard spacecraft to develop nutritional and exercise countermeasures, and make adjustments during long space missions. On Earth, the same technology could be used to monitor osteoporosis and its therapy. Aptamers bind to targets against which they are developed, much like antibodies. However, aptamers do not require animal hosts or cell culture and are therefore easier, faster, and less expensive to produce. In addition, aptamers sometimes exhibit greater affinity and specificity vs. comparable antibodies. In this work, fluorescent dyes and quenchers were added to the aptamers to enable pushbutton, one-step, bind-and-detect fluorescence resonance energy transfer (FRET) assays or tests that can be freeze-dried, rehydrated with body fluids, and used to quantitate bone loss of vitamin D levels with a handheld fluorometer in the spacecraft environment. This work generated specific, rapid, one-step FRET assays for the bone loss marker C-telopeptide (CTx) when extracted from urine, creatinine from urine, and vitamin D congeners in diluted serum. The assays were quantified in nanograms/mL using a handheld fluorometer connected to a laptop computer to convert the raw fluorescence values into concentrations of each analyte according to linear standard curves. DNA aptamers were selected and amplified for several rounds against a 26- amino acid form of CTx, creatinine, and vitamin D. The commonalities between loop structures were studied, and several common loop structures were converted into aptamer beacons with a fluorophore and quencher on each end. In theory, when the aptamer beacon binds its cognate target (CTx bone peptide, creatinine, or vitamin D), it is forced open and no longer quenched, so it gives off fluorescent light (when excited) in proportion to the amount of target present in a sample. This proportional increase in fluorescence is called a "lights on" FRET response. The vitamin D aptamer beacon gives a "lights off" or inversely proportional fluorescence response to the amount of vitamin D present in diluted serum. These FRET-aptamer assays are rapid (<30 minutes), sensitive (low ng/mL detection limits), and quite easy to carry out (add sample, mix, and detect in the handheld reader). Benefits include the speed of the assays as well as the small amount of space taken up by the handheld reader and cuvette assays. The aptamer DNA sequences represent novel additional features of the existing (patent-pending) FRET-aptamer assay platform.

Bruno, John G.↗

The state of the art of conventional flow visualization techniques for wind tunnel testing

Conventional wind tunnel flow visualization techniques which consist of surface flow methods, tracers, and optical methods are presented. Different surface flow methods are outlined: (1) liquid films (oil and fluorescent dye and UV lighting, renewable film via porous dispenser in model, volatile carrier fluid, cryogenic colored oil dots, oil film interferometry); (2) reactive surface treatment (reactive gas injection, reversible dye); (3) transition and heat transfer detectors (evaporation, sublimation, liquid crystals, phase change paints, IR thermography); and (4) tufts (fluorescent mini tufts, cryogenic suitability). Other methods are smoke wire techniques, vapor screens, and optical methods.

Settles, G. S.↗

Measuring Liquid Drops In Gas Flow

Nonintrusive optical technique enables measurement of drops of water ingested through aircraft-engine nacelle. Drops photographed by light of laser beam directed across nacelle inlet. Beam shaped by beam expander and slit into sheet 9 mm thick. Exposure time only 10 ns- length of laser pulse, and drop motion therefore frozen in each of series of photographs. Fluorescent dye added to water improves edge definition of photographic images of drops; scattered laser light and its interference effects filtered out and only light at fluorescence wavelength photographed. Technique used in research on ingestion of water from heavy rain or wheel spray, but adapts to any droplet-laden gas stream.

Parikh, Pradip G.↗

Filter Enhances Fluorescent-Penetrant-Inspecting Borescope

Slip-on eyepiece for commercial ultraviolet-light borescope reduces both amount of short-wave ultraviolet light that reaches viewer's eye and apparent intensity of unwanted reflections of white light from surfaces undergoing inspection. Fits on stock eyepiece of borescope, which illuminates surface inspected with intense ultraviolet light. Surface, which is treated with fluorescent dye, emits bright-green visible light wherever dye penetrates - in cracks and voids. Eyepiece contains deep-yellow Wratten 15 (G) filter, which attenuates unwanted light strongly but passes yellow-green fluorescence so defects seen clearly.

Molina, Orlando G.↗

Biosensors for Real-Time Monitoring of Radiation-Induced Biologic Effects in Space

This work seeks to develop cellular biosensors based on dendritic polymers. Nanoscale polymer structures less than 20 nm in diameter will be used as the basis of the biosensors. The structures will be designed to target into specific cells of an astronaut and be able to monitor health issues such as exposure to radiation. Multiple components can be assembled on the polymers including target directors, analytical devices (such as molecular probes), and reporting agents. The reporting will be accomplished through fluorescence signal monitoring, with the use of multispectral analysis for signal interpretation. These nanosensors could facilitate the success and increase the safety of extended space flight. The design and assembly of these devices has been pioneered at the Center for Biologic Nanotechnology in the University of Michigan. This period, synthesis of the test-bed biosensors continued. Studies were performed on the candidate fluorescent dyes to determine which might be suitable for the biosensor under development. Development continued on producing an artificial capillary bed as a tool for the use in the production of the fluorescence signal monitor. Work was also done on the in vitro multispectral analysis system, which uses the robotic microscope.

Baker, James R.↗

A laser fluorescence anemometer system for the Langley 16- by 24-inch water tunnel

A laser fluorescence anemometer which comprises a three-component laser Doppler velocimeter system with a fourth channel to measure fluorescent dye concentration has been installed in the NASA Langley 16- by 24-in water tunnel. The system includes custom designed optics, data acquisition, and traverse control instruments and a custom software package. Feasibility studies demonstrated how water tunnels can be used in conjunction with advanced optical techniques to provide nonintrusive detailed flow field measurements of complex fluid flows with a minimum of expense. The measurements show that the laser fluorescence anemometer can provide new insight into the structure, entrainment, control and of mixing vortical and shear layer flows.

Owen, F. K.↗