Search NASASearch

SEARCH · Search NASA

Results for “Fourier Transform Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

CIRS-lite, a Fourier Transform Spectrometer for Low-Cost Planetary Missions

Passive spectroscopic remote sensing of planetary atmospheres and surfaces in the thermal infrared is a powerful tool for obtaining information about surface and atmospheric temperatures, composition, and dynamics (via the thermal wind equation). Due to its broad spectral coverage, the Fourier transform spectrometer (FTS) is particularly suited to the exploration and discovery of molecular species. NASA's Goddard Space Flight Center (GSFC) developed the CIRS (Composite Infrared Spectrometer) FTS for the NASA/ESA Cassini mission to the Saturnian system. CIRS observes Saturn, Titan, icy moons such as Enceladus, and the rings in thermal self-emission over the spectral range of 7 to 1000 ell11. CIRS has given us important new insights into stratospheric composition and jets on Jupiter and Saturn, the cryo-geyser and thermal stripes on Enceladus, and the winter polar vortex on Titan. CIRS has a mass of 43 kg, contrasted with the earlier GSFC FTS, pre-Voyager IRIS (14 kg). Future low-cost planetary missions will have very tight constraints on science payload mass, thus we must endeavor to return to IRIS-level mass while maintaining CIRS-level science capabilities ("do more with less"). CIRS-lite achieves this by pursuing: a) more sensitive infrared detectors (high Tc superconductor) to enable smaller optics. b) changed long wavelength limit from 1000 to 300 microns to reduce diffraction by smaller optics. c) CVD (chemical vapor deposition) diamond beam-splitter for broad spectral coverage. d) single FTS architecture instead of a dual FTS architecture. e) novel materials, such as single crystal silicon for the input telescope primary.

Brasunas, J.

High resolution infrared spectroscopy of planetary molecules using diode lasers and Fourier transform spectrometers

Modern observations of infrared molecular lines in planets are performed at spectral resolutions which are as high as those available in the laboratory. Analysis of such data requires laboratory measurements at the highest possible resolution, which also yield accurate line positions and intensities. For planetary purposes the spectrometer must be coupled to sample cells which can be reduced in temperature and varied in pressure. An approach which produces the full range of required molecular line parameters uses a combination of tunable diode lasers and Fourier transform spectrometers (FTS). The FTS provides board spectral coverage and good calibration accuracy, while the diode laser can be used to study those regions which are not resolved by the FTS.

Jennings, Donald E.

Measurements of (C-12)H4 nu-4 band halfwidths using a tunable diode laser system and a Fourier transform spectrometer

Air-broadened and N2-broadened halfwidths at room temperature for twenty-five transitions in the nu-4 fundamental band of (C-12)H4 have been determined from IR absorption spectra recorded with a tunable diode laser spectrometer. Two tunable diode lasers operating in the 1250-1380-kayser region were used to obtain these data. Air-broadened halfwidths for twenty of these lines were also determined from additional spectra recorded at 0.01-kayser resolution with the Fourier transform spectrometer in the McMath solar telescope complex on Kitt Peak. The air-broadened halfwidths obtained from these two techniques are very consistent with agreement better than 3 percent in most cases.

Devi, V. M.

Radiometric Modeling and Calibration of the Geostationary Imaging Fourier Transform Spectrometer (GIFTS)Ground Based Measurement Experiment

The ultimate remote sensing benefits of the high resolution Infrared radiance spectrometers will be realized with their geostationary satellite implementation in the form of imaging spectrometers. This will enable dynamic features of the atmosphere s thermodynamic fields and pollutant and greenhouse gas constituents to be observed for revolutionary improvements in weather forecasts and more accurate air quality and climate predictions. As an important step toward realizing this application objective, the Geostationary Imaging Fourier Transform Spectrometer (GIFTS) Engineering Demonstration Unit (EDU) was successfully developed under the NASA New Millennium Program, 2000-2006. The GIFTS-EDU instrument employs three focal plane arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The GIFTS calibration is achieved using internal blackbody calibration references at ambient (260 K) and hot (286 K) temperatures. In this paper, we introduce a refined calibration technique that utilizes Principle Component (PC) analysis to compensate for instrument distortions and artifacts, therefore, enhancing the absolute calibration accuracy. This method is applied to data collected during the GIFTS Ground Based Measurement (GBM) experiment, together with simultaneous observations by the accurately calibrated AERI (Atmospheric Emitted Radiance Interferometer), both simultaneously zenith viewing the sky through the same external scene mirror at ten-minute intervals throughout a cloudless day at Logan Utah on September 13, 2006. The accurately calibrated GIFTS radiances are produced using the first four PC scores in the GIFTS-AERI regression model. Temperature and moisture profiles retrieved from the PC-calibrated GIFTS radiances are verified against radiosonde measurements collected throughout the GIFTS sky measurement period. Using the GIFTS GBM calibration model, we compute the calibrated radiances from data collected during the moon tracking and viewing experiment events. From which, we derive the lunar surface temperature and emissivity associated with the moon viewing measurements.

Tian, Jialin

Fourier-Transform Infrared Spectrometer

Fourier-transform spectrometer provides approximately hundredfold increase in luminosity at detector plane over that achievable with older instruments of this type. Used to analyze such weak sources as pollutants and other low-concentration substances in atmosphere. Interferometer creates fringe patterns on two distinct arrays of light detectors, which observe different wavelength bands. Objective lens focuses scene on image plane, which contains optical chopper. To make instrument less susceptible to variations in scene under observation, field and detector lenses focus entrance aperture, rather that image, onto detector array.

Schindler, R. A.

A Fourier transform spectrometer for visible and near ultra-violet measurements of atmospheric absorption

The development of a prototype, ground-based, Sun-pointed Michelson interferometric spectrometer is described. Its intended use is to measure the atmospheric amount of various gases which absorb in the near-infrared, visible, and near-ultraviolet portions of the electromagnetic spectrum. Preliminary spectra which contain the alpha, 0.8 micrometer, and rho sigma tau water vapor absorption bands in the near-infrared are presented to indicate the present capability of the system. Ultimately, the spectrometer can be used to explore the feasible applications of Fourier transform spectroscopy in the ultraviolet where grating spectrometers were used exclusively.

Parsons, C. L.

Fourier transform spectrometer observations of solar carbon monoxide. II - Simultaneous cospatial measurements of the fundamental and first-overtone bands, and Ca II K, in quiet and active regions

Fourier transform spectrometry has yielded simultaneous cospatial measurements of important diagnostics of thermal structure in the high solar photosphere and low chromosphere. It is noted that the anomalous behavior of the fundamental bands of CO in quiet areas near the limb is accentuated in an active region plage observed close to the limb. The difference between the core temperatures of the CO fundamental bands in a plage and a nearby quiet region at the limb is larger than the corresponding brightness temperature differences in the inner wings of the Ca II line measured in a quiet region and several plages closer to the disk center. Numerical simulations indicate that the disparate behavior of the CO bands with respect to Ca II K cannot be reconciled with existing single component thermal structure models; a two-component atmosphere is required.

Ayres, T. R.

JPL Fourier transform ultraviolet spectrometer

The Fourier Transform Ultraviolet Spectrometer (FTUVS) is a new high resolution interferometric spectrometer for multiple-species detection in the UV, visible and near-IR. As an OH sensor, measurements can be carried out by remote sensing (limb emission and column absorption), or in-situ sensing (long-path absorption or laser-induced fluorescence). As a high resolution detector in a high repetition rate (greater than 10 kHz) LIF system, OH fluorescence can be discriminated against non-resonant background emission and laser scatter, permitting (0, 0) excitation.

Cageao, R. P.

Focal-plane optimization for detector noise limited performance in cryogenic Fourier transform spectrometer /FTS/ sensors

A study was performed to determine the optimum focal plane configuration including optics, filters and detector-preamplifier selection. The configuration was optimized particularly with respect to minimizing the noise level, but fabrication considerations for a cryogenic environment were also taken into account. The noise terms from source, background, detector electronics and charged particle radiation were quantitatively evaluated. It appears that noise equivalent spectral radiance less than 10 to the -11th W/sq cm per sr per kayser can be achieved between 2.5 and 20 microns.

Mcguirk, M.

Optical alignment of high resolution Fourier transform spectrometers

Remote sensing, high resolution FTS instruments often contain three primary optical subsystems: Fore-Optics, Interferometer Optics, and Post, or Detector Optics. We discuss the alignment of a double-pass FTS containing a cat's-eye retro-reflector. Also, the alignment of fore-optics containing confocal paraboloids with a reflecting field stop which relays a field image onto a camera is discussed.

Breckinridge, J. B.

Exact modeling of lineshape and wavenumber variations for off-axis detectors in Fourier transform spectrometers (FTS) sensor systems

The utilization of detector arrays in the focal planes of FTS sensor systems allows simultaneous spectral and spatial measurements. However, spectral lineshapes and wavenumber locations depend upon the size and location of the detector elements with respect to the Haidinger fringe pattern of the FTS sensor. These spectral distortions can be generalized as a shift and shape change of the FTS sensor lineshape. Depending on the distortions that can be tolerated, a degree of field-widening can be obtained for a given Haidinger fringe pattern. An exact model for predicting the FTS lineshape distortions is presented. The model is applied to several contemporary applications in order to quantify the magnitude of distortions to be expected.

Niple, E.

Detection of the 267 GHz J = 1-0 rotational transition of PH3 in Saturn with a new Fourier transform spectrometer

In recent observations at the Caltech Submillimeter Observatory, the highly pressure-broadened (FWHM = 11.2 GHz) J = 1-0 rotational transition of PH3 (phosphine) was detected on Saturn. By modeling the Saturnian atmosphere with a radiative transfer code, the observed line profile was consistent with a constant PH3 mole fraction of 3.0 plus or minus 1.0 ppm in the upper troposphere. A best-fit to the depth of the line implies a cutoff at high altitudes, with no PH3 present at pressures approximately less than 100 mbar. The observed line depth, combined with the lack of a detectable emission core, implies that a cutoff in the PH3 abundance occurs at a pressure between 13 and 140 mbar. PH3 in Jupiter was not detected, nor any other molecular lines between 195 and 295 GHz (1.54 mm and 1.02 mm, respectively) in either Jupiter or Saturn.

Weisstein, Eric W.

A cryogenic scan mechanism for use in Fourier transform spectrometers

This paper describes the requirements, design, assembly and testing of the linear Scan Mechanism (SM) of the Composite Infrared Spectrometer (CIRS) Instrument. The mechanism consists of an over constrained flexible structure, an innovative moving magnet actuator, passive eddy current dampers, a Differential Eddy Current (DEC) sensor, Optical Limit Sensors (OLS), and a launch lock. Although all the components of the mechanism are discussed, the flexible structure and the magnetic components are the primary focus. Several problems encountered and solutions implemented during the development of the scan mechanism are also described.

Hakun, Claef F.