At least 55 records · Page 3

X-ray Phase Contrast analysis - Digital wavefront development

Optical schemes that enable imaging of the phase shift produced by an object have become popular in the x-ray region, where phase can be the dominant contrast mechanism. The propagation-based technique consists of recording the interference pattern produced by choosing one or several sample-to-detector distances. Pioneering studies, carried out making use of synchrotron radiation, demonstrated that this technique results in a dramatic increase of image contrast and detail visibility, allowing the detection of structures invisible with conventional techniques. An experimental and theoretical study of in-line hard x-ray phase-contrast imaging had been performed. The theoretical description of the technique is based on Fresnel diffraction. As an illustration of the potential of this quantitative imaging technique, high-resolution x-ray phase contrast images of simple objects will be presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct and alignment-insensitive measurement of cantilever curvature

We analytically derive and experimentally demonstrate a method for the simultaneous measurement of deflection for large arrays of cantilevers. The Fresnel diffraction patterns of a cantilever independently reveal tilt, curvature, cubic, and higher order bending of the cantilever. It provides a calibrated absolute measurement of the polynomial coefficients describing the cantilever shape, without careful alignment and could be applied to several cantilevers simultaneously with no added complexity. We show that the method is easily implemented, works in both liquid media and in air, for a broad range of displacements and is especially suited to the requirements for multi-marker biosensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coating considerations for mirrors of CPV devices

One of the different optical concepts for concentrator devices is to place a focussing primary mirror behind a transparent front plate. In addition (also in case of Fresnel-diffractive main optics), further 'secondary' reflectors may be used further along the beam path. Such mirrors are usually implemented as coating stacks of a highly reflective metal - usually silver - and protective layers. The protective layers are preferably designed as reflection enhancing interference stack. The design of such protective layer stacks yields two difficulties, which are addressed in this paper: (a) vacuum coating of three-dimensional parts will result in a thickness distribution and the optical design of the stack should thus be tolerant to layer thickness variations, and (b) different places of the mirror will have different angle-of-incidence of the sunlight under operating conditions. As result, the layer stack has a different design at different places of the mirror.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Semiclassical estimates of electromagnetic Casimir self-energies of spherical and cylindrical metallic shells

The leading semiclassical estimates of the electromagnetic Casimir stresses on a spherical and a cylindrical metallic shell are within 1% of the field theoretical values. The electromagnetic Casimir energy for both geometries is given by two decoupled massless scalars that satisfy conformally covariant boundary conditions. Surface contributions vanish for smooth metallic boundaries, and the finite electromagnetic Casimir energy in leading semiclassical approximation is due to quadratic fluctuations about periodic rays in the interior of the cavity only. Semiclassically, the nonvanishing Casimir energy of a metallic cylindrical shell is almost entirely due to Fresnel diffraction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward an integrated platform for characterizing laser-driven, isochorically heated plasmas with 1 µm spatial resolution

Warm dense matter is a region of phase space that is of high interest to multiple scientific communities ranging from astrophysics to inertial confinement fusion. Further understanding of the conditions and properties of this complex state of matter necessitates experimental benchmarking of the current theoretical models. We discuss the development of an x-ray radiography platform designed to measure warm dense matter transport properties at large laser facilities such as the OMEGA Laser Facility. Our platform, Fresnel Diffractive Radiography, allows for high spatial resolution imaging of isochorically heated targets, resulting in notable diffractive effects at sharp density gradients that are influenced by transport properties such as thermal conductivity. We discuss initial results, highlighting the capabilities of the platform in measuring diffractive features with micron-level spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Higher-order phase shift reconstruction approach

Purpose: Biological soft tissues encountered in clinical and preclinical imaging mainly consists of atoms of light elements with low atomic numbers and their elemental composition is nearly uniform with little density variation. Hence, x-ray attenuation contrast is relatively poor and cannot achieve satisfactory sensitivity and specificity. In contrast, x-ray phase-contrast provides a new mechanism for soft tissue imaging. The x-ray phase shift of soft tissues is about a thousand times greater than the x-ray absorption over the diagnostic x-ray energy range, yielding a higher signal-to-noise ratio than the attenuation contrast counterpart. Thus, phase-contrast imaging is a promising technique to reveal detailed structural variation in soft tissues, offering a high contrast resolution between healthy and malignant tissues. Here the authors develop a novel phase retrieval method to reconstruct the phase image on the object plane from the intensity measurements. The reconstructed phase image is a projection of the phase shift induced by an object and serves as input to reconstruct the 3D refractive index distribution inside the object using a tomographic reconstruction algorithm. Such x-ray refractive index images can reveal structural features in soft tissues, with excellent resolution differentiating healthy and malignant tissues. Methods: A novel phase retrieval approach is proposed to reconstruct an x-ray phase image of an object based on the paraxial Fresnel-Kirchhoff diffraction theory. A primary advantage of the authors' approach is higher-order accuracy over that with the conventional linear approximation models, relaxing the current restriction of slow phase variation. The nonlinear terms in the autocorrelation equation of the Fresnel diffraction pattern are eliminated using intensity images measured at different distances in the Fresnel diffraction region, simplifying the phase reconstruction to a linear inverse problem. Numerical experiments are performed to demonstrate the accuracy and stability of the proposed approach. Results: The proposed reconstruction formula is a generalization of the transport of intensity equation (TIE). It has the second-order accuracy compared to the linear model used in the conventional phase retrieval approach. The numerical experiments demonstrate that the accuracy and stability of the proposed phase reconstruction method outperforms the TIE-based reconstruction method. Conclusions: A novel approach has been proposed to retrieve an x-ray phase shift image induced by an object from intensity images measured at different distances in the Fresnel diffraction region. The authors' approach has the second-order accuracy and is able to retrieve the phase shift of an object stably, overcoming the restriction of slow phase variation assumed by the conventional phase retrieval techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical study of a spectrum splitting solar concentrator based on a combination of a diffraction grating and a Fresnel lens

This paper presents recent improvements of our new solar concentrator design for space application. The concentrator is based on a combination of a diffraction grating (blazed or lamellar) coupled with a Fresnel lens. Thanks to this diffractive/refractive combination, this optical element splits spatially and spectrally the light and focus approximately respectively visible light and IR light onto electrically independent specific cells. It avoid the use of MJs cells and then also their limitations like current matching and lattice matching conditions, leading theoretically to a more tolerant system. The concept is reminded, with recent optimizations, ideal and more realistic results, and the description of an experimental realization highlighting the feasibility of the concept and the closeness of theoretical and experimental results.

14 SOLAR ENERGY↗

Use of Justified Constraints in Coherent Diffractive Imaging

We demonstrate the use of physically justified object constraints in x-ray Fresnel coherent diffractive imaging on a sample of nanoporous gold prepared by dealloying. Use of these constraints in the reconstruction algorithm enabled highly reliable imaging of the sample's shape and quantification of the 23- to 52-nm pore structure within it without use of a tight object support constraint.

36 MATERIALS SCIENCE↗

Trajectory-Based Interpretation of Laser Light Diffraction by a Sharp Edge

In the diffraction pattern produced by a half-plane sharp edge when it obstructs the passage of a laser beam, two characteristic regions are noticeable. There is a central region, where the diffraction of laser light appears in the region of geometric shadow, while intensity oscillations are observed in the non-obstructed area. On both sides of the edge, there are also very long light traces along the normal to the edge of the obstacle. The theoretical explanation of this phenomenon is based on the Fresnel–Kirchhoff diffraction theory applied to the Gaussian beam propagation behind the obstacle. In this paper, we supplement this explanation by considering electromagnetic flow lines, which provide a more complete interpretation of the phenomenon in terms of electric and magnetic fields and flux lines; at the same time, that can be related to average photon paths. © 2018, Springer Science+Business Media, LLC, part of Springer Nature.

43 PARTICLE ACCELERATORS↗

Improved filters for angular filter refractometry

Angular filter refractometry is an optical diagnostic that measures the absolute contours of a line-integrated density gradient by placing a filter with alternating opaque and transparent zones in the focal plane of a probe beam, which produce corresponding alternating light and dark regions in the image plane. Identifying transitions between these regions with specific zones on the angular filter (AF) allows the line-integrated density to be determined, but the sign of the density gradient at each transition is degenerate and must be broken using other information about the object plasma. Additional features from diffraction in the filter plane often complicate data analysis. Here, in this paper, we present an improved AF design that uses a stochastic pixel pattern with a sinusoidal radial profile to minimize unwanted diffraction effects in the image caused by the sharp edges of the filter bands. We also present a technique in which a pair of AFs with different patterns on two branches of the same probe beam can be used to break the density gradient degeneracy. Both techniques are demonstrated using a synthetic diagnostic and data collected on the OMEGA EP (extended performance) laser.

47 OTHER INSTRUMENTATION↗

Materials for x-ray refractive lenses minimizing wavefront distortions

Refraction through curved surfaces, reflection from curved mirrors in grazing incidence, and diffraction from Fresnel zone plates are key hard x-ray focusing mechanisms. In this article, we present materials used for refractive x-ray lenses. Important properties of such x-ray lenses include focusing strength, shape, and the material’s homogeneity and absorption coefficient. Both the properties of the initial material and the fabrication process result in a lens with imperfections, which can lead to unwanted wavefront distortions. Different fabrication methods for one-dimensional and two-dimensional focusing lenses are presented, together with the respective benefits and inconveniences that are mostly due to shape fidelity. Different materials and material grades have been investigated in terms of their homogeneity and the absence of inclusions. Single-crystalline materials show high homogeneity, but suffer from unwanted diffracted radiation, which can be avoided using amorphous materials. Lastly, we show that shape imperfections can be corrected using a correction lens.

36 MATERIALS SCIENCE↗

Transformation of double-half inverse Gaussian hollow beams into superposition of finite Airy beams using an optical Airy transform

In the present work, we investigate theoretically the transformation of a double-half inverse Gaussian hollow (DHIGH) beam into a superposition of finite Airy beams by using an optical Airy transform system. The analytical expression of the generated finite Airy beam is derived by means of the generalized Huygens–Fresnel integral diffraction. Numerical calculations show that the optical Airy transform system converts the central dark spot of the hollow incident beam into peak intensity. It is demonstrated that the characteristics of the transverse intensity distribution of the output finite Airy beam are determined by the phase pattern’s constants of the Airy transform system and the radius size of the incident DHIGH beam. Moreover, it is shown that the profile of the central peak intensity of the generated beam can be controlled by means of the radius size of the incident hollow DHIGH beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shape error analysis for reflective nano focusing optics

Focusing performance of reflective x-ray optics is determined by surface figure accuracy. Any surface imperfection present on such optics introduces a phase error in the outgoing wave fields. Therefore converging beam at the focal spot will differ from the desired performance. Effect of these errors on focusing performance can be calculated by wave optical approach considering a coherent wave field illumination of optical elements. We have developed a wave optics simulator using Fresnel-Kirchhoff diffraction integral to calculate the mirror pupil function. Both analytically calculated and measured surface topography data can be taken as an aberration source to outgoing wave fields. Simulations are performed to study the effect of surface height fluctuations on focusing performances over wide frequency range in high, mid and low frequency band. The results using real shape profile measured with long trace profilometer (LTP) suggest that the shape error of {lambda}/4 PV (peak to valley) is tolerable to achieve diffraction limited performance. It is desirable to remove shape error of very low frequency as 0.1 mm{sup -1} which otherwise will generate beam waist or satellite peaks. All other frequencies above this limit will not affect the focused beam profile but only caused a loss in intensity.

43 PARTICLE ACCELERATORS↗

TIA: A forward model and analyzer for Talbot interferometry experiments of dense plasmas

Interferometry is one of the most sensitive and successful diagnostic methods for plasmas. However, owing to the design of most common interferometric systems, the wavelengths of operation and, therefore, the range of densities and temperatures that can be probed are severely limited. Talbot–Lau interferometry offers the possibility of extending interferometry measurements to x-ray wavelengths by means of the Talbot effect. While there have been several proof-of-concept experiments showing the efficacy of this method, it is only recently that experiments to probe High Energy Density (HED) plasmas using Talbot–Lau interferometry are starting to take place. To improve these experimental designs, we present here the Talbot-Interferometry Analyzer (TIA) tool, a forward model for generating and postprocessing synthetic x-ray interferometry images from a Talbot–Lau interferometer. Although TIA can work with any two-dimensional hydrodynamic code to study plasma conditions as close to reality as possible, this software has been designed to work by default with output files from the hydrodynamic code FLASH, making the tool user-friendly and accessible to the general plasma physics community. Here, the model has been built into a standalone app, which can be installed by anyone with access to the MATLAB runtime installer and is available upon request to the authors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase retrieval for refraction-enhanced x-ray radiography using a deep neural network

X-ray refraction-enhanced radiography (RER) or phase contrast imaging is widely used to study internal discontinuities within materials. The resulting radiograph captures both the decrease in intensity caused by material absorption along the x-ray path, as well as the phase shift, which is highly sensitive to gradients in density. A significant challenge lies in effectively analyzing the radiographs to decouple the intensity and phase information and accurately ascertain the density profile. Conventional algorithms often yield ambiguous and unrealistic results due to difficulties in including physical constraints and other relevant information. We have developed an algorithm that uses a deep neural network to address these issues and applied it to extract the detailed density profile from an experimental RER. To generalize the applicability of our algorithm, we have developed a technique that quantitatively evaluates the complexity of the phase retrieval process based on the characteristics of the sample and the configuration of the experiment. Accordingly, this evaluation aids in the selection of the neural network architecture for each specific case. Beyond RER, the model has potential applications for other diagnostics where phase retrieval analysis is required.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Onset of nuclear structure effects in near-barrier elastic scattering of weakly bound nuclei: {sup 6}He and {sup 6}Li compared

The elastic scattering of the halo nucleus {sup 6}He from heavy targets at incident energies near the Coulomb barrier displays a marked deviation from the standard Fresnel-type diffraction behavior. This deviation is due to the strong Coulomb dipole breakup coupling produced by the Coulomb field of the heavy target, a specific feature of the nuclear structure of {sup 6}He. We have performed Continuum Discretized Coupled Channels calculations for the elastic scattering of {sup 6}He and {sup 6}Li from {sup 58}Ni, {sup 120}Sn, {sup 144}Sm, {sup 181}Ta and {sup 208}Pb targets in order to determine the range of Z{sub T} where this nuclear-structure specific coupling effect becomes manifest. We find that the strong Coulomb dipole breakup coupling effect is only clearly experimentally distinguishable for targets of Z{sub T}{approx_equal}80.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

(U) Estimating the Photonics Budget, Resolution, and Signal Requirements for a Multi-Monochromatic X-ray Imager

This document examines the performance of a generic flat-mirror multimonochromatic imager (MMI), with special emphasis on existing instruments at NIF and Omega. We begin by deriving the standard equation for the mean number of photons detected per resolution element. The pinhole energy bandwidth is a contributing factor; this is dominated by the finite size of the source and may be considerable. The most common method for estimating the spatial resolution of such a system (quadrature addition) is, technically, mathematically invalid for this case. However, under the proper circumstances it may produce good estimates compared to a rigorous calculation based on the convolution of point-spread functions. Diffraction is an important contribution to the spatial resolution. Common approximations based on Fraunhofer (farfield) diffraction may be inappropriate and misleading, as the instrument may reside in multiple regimes depending upon its configuration or the energy of interest. It is crucial to identify the correct diffraction regime; Fraunhofer and Fresnel (near-field) diffraction profiles are substantially different, the latter being considerably wider. Finally, we combine the photonics and resolution analyses to derive an expression for the minimum signal level such that the resulting images are not dominated by photon statistics. This analysis is consistent with observed performance of the NIF MMI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of a multilevel THz Fresnel lens by femtosecond laser ablation

The possibility of fabricating a silicon diffractive fourlevel THz Fresnel lens by laser ablation is studied. For a microrelief to be formed on the sample surface, use is made of a femtosecond Yb : YAG laser with a high pulse repetition rate (f = 200 kHz). Characteristics of the diffractive optical element are investigated in the beam of a 141-mm free-electron laser. The measured diffraction efficiency of the lens is in good agreement with the theoretical estimate. (laser technologies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗