LANL Countroom Gamma-Gamma Coincidence Capabilities [Slides]
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Presentation to be presented during the first annual Prompt Radiation Detection and Imaging Workshop, hosted by the NNSS Dynamic Instruments Team, April 25–28, 2022, at NLV C-01 Auditorium and via Webex.
Explore the source record for details and available documents.
The properties of the 2$^+_1$ and 2$^+_2$ excited states in 14 C were studied in an experiment conducted at Argonne National Laboratory. A 9 Be( 6 Li,pγ) fusion-evaporation reaction and the GRETINA-ORRUBA setup were employed to populate states of 14 C and detect γ-particle coincidence events. Finally, the precise determination of the 2$^+_1$ level energy, complemented by the estimation of the γ-ray branch of the 2$^+_2$ near-threshold state, will serve as a benchmark to test the Shell Model Embedded in the Continuum calculations.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A novel modelling methodology has been developed for the creation of a realistic plasma gamma-ray source for Monte Carlo transport simulations in the tokamak JET. The methodology couples the TRANSP code for plasma transport calculations with the MCNP Monte Carlo particle transport code, thus connecting plasma physics with gamma-ray transport. Here, we present the validation of the developed source methodology by comparing calculated gamma-ray spectra with measurements performed at JET. The validation focuses on gamma-ray spectra measured by the tangential gamma-ray spectrometer during two JET three ion RF scenario discharges, performed in the JET 2019 deuterium experimental campaign. For validation the calculated plasma gamma-ray spectrum was combined with the neutron induced prompt gamma-ray background, originating in the vacuum vessel, and scaled to absolute values calculating the total number of plasma gamma-ray and neutron emitting reactions. The comparison between calculated and measured gamma-ray spectra shows good agreement with the shape of the calculated gamma-ray spectra matching that of measurements for both studied discharges. Moreover, the calculated absolute values of the gamma-ray spectra were of the same order of magnitude at the position of the gamma-ray detector located at the end of a long line-of-sight in a biological shield. Finally, the comparison has validated the developed plasma gamma-ray source methodology for MCNP photon transport calculations at JET. The validation provides a basis for the developed plasma gamma-ray source to be used as a support for the development of future tokamaks such as DEMO.
Gamma survey techniques are an especially powerful decommissioning tool at naturally occurring radioactive material (NORM) sites due to both the low cost to obtain data over a large spatial scale and the abundance of gamma emitters in the uranium and thorium decay series. Gamma surveys are executed by coupling a detector - most often a sodium iodide crystal - to a global positioning system (GPS), then reporting a location and gross gamma reading coincidentally to a data logger. Systems may be carried by workers or mounted to a car, all-terrain vehicle, or unmanned aerial system (UAS). The resulting data set provides a high-resolution but low precision map of the gamma radiation field over the area surveyed. Frequently this map is also correlated to soil concentrations of NORM radionuclides (most often, Ra-226) and/or exposure rate. Gamma survey parameters such as movement speed, transect spacing, and data logging frequency define the spatial resolution of the resulting surface, and can be optimized depending on the desired survey sensitivity. This paper examines gamma survey as a tool for decommissioning NORM sites and provides an overview of current gamma survey technology designed to improve the efficiency and effectiveness of the decommissioning process. Topics to be discussed in the paper include: - An overview of gamma survey systems, and the utility of different delivery vehicles depending on desired cost, desired spatial resolution, and site topography. - The influence of physical detector characteristics on detection sensitivity and survey planning. - The tradeoff between high-resolution and large spatial extent, but inherently uncertain data, and low-resolution, low spatial extent, but highly certain data, as well as the specific utility of each of these types of data during NORM facility decommissioning. - Confounding variables that may limit the utility of gamma survey at some sites (e.g., radon gas and spatial heterogeneity / hot spots), and methods to plan for and control these conditions. Results show that the confounding variables, such as radon and data output can greatly influence the overall data quality associated with the decommissioning process. In addition, the use of real-time and aerial survey platforms provides a method for ensuring proper spatial extent of the data. When applied thoughtfully, gamma survey is a powerful tool for detecting NORM radionuclides in the environment and a cost-effective technique for identifying areas requiring remediation. However, entities performing or using gamma survey as a decommissioning tool must be aware of both its advantages and its limitations before basing remediation or regulatory action on gamma survey results. (authors)
Gamma spectrometry is a key element in much of the post-irradiation examination (PIE) work performed under the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program (Demkowicz et al. 2015; Stempien et al. 2021). Gamma spectrometers are integrated into three major capabilities used at the Oak Ridge National Laboratory (ORNL) Irradiated Fuels Examination Laboratory (IFEL) for PIE of tristructural-isotropic (TRISO) coated particles and fuel compacts: the Core Conduction Cooldown Test Facility (CCCTF), the Vertical Counting System (VCS), and the Irradiated Microsphere Gamma Analyzer (IMGA). The CCCTF includes liquid-nitrogen-cooled traps to extract 85 Kr out of the He sweep gas that passes through the furnace in which the fuel compacts are heated during safety testing. Analysis of the 85 Kr activity in the traps is the primary indicator for TRISO failure during safety testing. The VCS is a system used to accurately measure gamma emission from components placed in a lead-shielded chamber. It is used to count the CCCTF deposition cups after removal from furnace. Each cup resides in the CCCTF furnace for typically 12–24 h and is periodically replaced with a fresh cup throughout the safety test. Metallic fission products collect on the water-cooled cups and several gamma-emitting isotopes ( 110 mAg, 134 Cs, 137 Cs, 154 Eu, and 155 Eu) are often measured and provide indication of the retention performance of the TRISO coatings. The VCS is also used to measure the presence of these isotopes on the CCCTF tantalum liner and sweep gas inlet tube for the determination of cup collection efficiency, as well as support other gamma spectrometry needs related to calibration of the 85 Kr fission gas traps and various other special PIE tasks. The IMGA uses gamma spectrometry to measure the inventory of gamma-emitting isotopes in individual TRISO particles. An automated particle handling system within the IMGA hot cell removes each particle from a source vial and positions it in front of a gamma detector, and output from the gamma spectrometer is used by the IMGA software to determine a destination vial such that particles are sorted according to their inventory and retention characteristics. At the conclusion of the AGR-1 and AGR-2 PIE campaigns, the gamma spectrometer systems used at ORNL to support that PIE had reached the end of its life cycle due to gradual obsolescence of the hardware and software. Upgrade of the Canberra Genie 2000 software used by these systems to a Windows 10 version was not a viable option, because the newest Windows 10 version offered by Mirion (the new owner of the Canberra technology) did not include the dynamic-link libraries (DLLs) needed for integration with the custom PIE software used with the CCCTF and IMGA, and Mirion had no current plans for development and release of Windows 10 versions of these DLLs with the Model S560 Genie 2000 Programming Library. Ultimately a switch was made to ORTEC gamma spectrometry systems, which appeared to be a more sustainable solution due to more proactive vendor support. The ORTEC conversion involved replacing the aging detector preamplifier and multichannel analyzer (MCA) hardware, upgrading the obsolete Windows 7 computers to Windows 10 compatible models, adopting ORTEC GammaVision software, and extensive modification of the ORNL-developed Visual Basic .NET (VB.NET) programs that provide the CCCTF and IMGA user interfaces.
Thermal and simultaneous thermal and gamma radiation aging experiments were conducted on an industry grade cross-linked polyethylene (XLPE) cable insulation material, which is a composite material with XLPE as polymer matrix and various additives and fillers. Reverse engineering was conducted to identify and quantify the material composition given that this information was not revealed by the cable manufacture. Samples were then aged at temperatures of 60, 90, and 115 °C, exposed to gamma radiation for total doses of 0 to 324 kGy, and at dose rates of 0 to 540 Gy/h. Aging mechanisms were studied using various materials characterization techniques including pyrolysis gas chromatography mass spectrometry (Py-GCMS), differential scanning calorimetry (DSC), nuclear magnetic resonance spectroscopy (NMR), and gel-fraction tests. Results show that the flame-retardant components were decomposed into smaller molecules when the material was exposed to gamma radiation, while no changes were observed when the samples were aged thermally without gamma radiation. With exposure to gamma radiation, the crystalline phase of the XLPE were damaged by gamma radiation introducing defects in the crystals, resulting in smaller and less perfect crystals. The dominance of chain scission or chain reformation process largely depends on the chain mobility, which is decided by the aging temperature. Chain scission was seen to dominate when the material was exposed to gamma radiation at 60 °C. Chain cross-linking slightly dominated when the material was exposed to gamma radiation at 90 °C and became more dominant with exposure to gamma radiation at 115 °C. No significant change to the XLPE polymer matrix was observed when the samples were exposed to thermal aging without gamma radiation. Finally, antioxidant is more effective in protecting the XLPE polymer matrix under thermal aging, but less effective with sample exposure to gamma radiation.
The results from gamma spectrometry examination of the different components from the combined third and fourth U.S. Advanced Gas Reactor (AGR) TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail (DTF) particles surrounded by inner and outer graphite and/or graphitic matrix rings and a graphite sink ring were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (i.e., Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. The inner and outer rings were also examined by gamma spectrometry to evaluate the total fission product inventory of the rings, and gamma emission computed tomography (GECT) was used to investigate the spatial distribution of gamma-emitting fission products within the rings. This report focuses on results obtained via the Precision Gamma Scanner (PGS) for the compacts and inner and outer rings. These non-destructive gamma measurements are currently being compared to recent destructive measurements of spatial fission product distributions in the rings and to predictions made via mathematical modeling. A separate report discusses the entire AGR-3/4 fission product mass balance for all irradiation capsule components including the inner and outer rings, graphite sink rings, capsule spacers, capsule foils, through tubes, and felts. This report is similar to the conference proceedings: Harp, J.M., Demkowicz, P.A., and Stempien, J.D., “Initial gamma spectrometry examination of the AGR-3/4 irradiation,” International Topical Meeting High Temperature Reactor Technology (HTR 2016), Las Vegas, NV, USA, November 2016, Paper HTR2016-18593, but it has been updated to reflect all the data that has been collected on AGR-3/4 using PGS. The Appendices contain extensive data from the collected gamma spectra.
The results from gamma spectrometry examination of the different components from the combined third and fourth U.S. Advanced Gas Reactor (AGR) TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail (DTF) particles surrounded by inner and outer graphite and/or graphitic matrix rings and a graphite sink ring were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (i.e., Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. The inner and outer rings were also examined by gamma spectrometry to evaluate the total fission product inventory of the rings, and gamma emission computed tomography (GECT) was used to investigate the spatial distribution of gamma-emitting fission products within the rings. This report focuses on results obtained via the Precision Gamma Scanner (PGS) for the compacts and inner and outer rings. These non-destructive gamma measurements are currently being compared to recent destructive measurements of spatial fission product distributions in the rings and to predictions made via mathematical modeling. A separate report discusses the entire AGR-3/4 fission product mass balance for all irradiation capsule components including the inner and outer rings, graphite sink rings, capsule spacers, capsule foils, through tubes, and felts. This report is similar to the conference proceedings: Harp, J.M., Demkowicz, P.A., and Stempien, J.D., “Initial gamma spectrometry examination of the AGR-3/4 irradiation,” International Topical Meeting High Temperature Reactor Technology (HTR 2016), Las Vegas, NV, USA, November 2016, Paper HTR2016-18593, but it has been updated to reflect all the data that has been collected on AGR-3/4 using PGS. The Appendices contain extensive data from the collected gamma spectra.
Screening and inspection of cargo containers are two essential methods to nondestructively examine the contents of shipment. These methods enable the detection of illicit transportation of unauthorized materials such as nuclear and radioactive materials, explosives, drugs, and so on, typically at borders or secure facilities. Although high-energy X-ray transmission is a standard system and is widely used for cargo inspection, the inherent challenges of high false-positive rates and high attenuation factors necessitate the development of complementary techniques that can increase the detection efficiency and accuracy in large and dense materials. Gamma-rays, which possess higher penetration characteristics because of their high energy, offer an alternative nonintrusive modality for cargo scanning. They represent a promising inspection method when compared to X-rays for three reasons: (1) improved ability to detect nuclear and radioactive materials, (2) higher inspection throughput rates, and (3) lower false-positive rates. Currently, there are two main gamma-ray inspection techniques, active and passive interrogation. Active interrogation can be further grouped into (1) gamma-ray transmission imaging and (2) neutron-induced gamma-ray emission detection. Gamma-ray transmission imaging utilizes differences in material densities for mapping the shipment contents and detecting anomalies. It is analogous to the X-ray transmission method; however, the high-energy photons make it more difficult to shield against, which enables more efficient performance in large and dense material inspection. Neutron-induced gamma-ray emission inspection is designed for the detection of nuclear and radioactive material because those materials emit characteristic gamma-rays when they are activated by neutron absorption. On the other hand, passive interrogation techniques rely on high-efficiency detectors to detect radiation emitted from hidden special nuclear or other radioactive materials. Similar to passive interrogation, cosmic ray muon monitoring and imaging are relatively new techniques that do not require external radioactive sources. These techniques have received attention as a potential next-generation radiographic probe to identify illicit transportation of nuclear and radioactive materials in cargo containers. Cosmic ray muons have unique features, (1) much higher energies than X-rays or gamma-rays (on the order of 10−1—104 GeV), (2) enhanced penetration capability, and (3) natural occurrence, thereby eliminating the need for induced radiation sources. These features enable cosmic ray muons to be utilized for detection of special nuclear materials in high-background-noise environments. By analyzing incoming and outgoing muon trajectories, scattering angles, and energies, it has been shown that it would be possible to locate hidden and well-shielded materials in cargo containers via three-dimensional muon tomography images or signal analysis. Gamma-rays, cosmic ray muons, and other nonintrusive cargo inspection modalities are complementary to each other, allowing them to address various cargo inspection conditions (i.e., scanning time, cost, radiation exposure level, and types of target materials). This chapter presents a detailed review of the theoretical fundamentals and technical principles behind the current gamma-ray and cosmic ray muon modalities for cargo inspection. Additionally, critical assessments and suggestions for the future directions to advance the use of gamma and muon modalities are discussed.
We have applied positron annihilation induced Auger-gamma coincidence spectroscopy to identify important mechanisms responsible for the emission of low energy electrons following the sudden creation of holes in bilayer graphene on copper substrate. The novel surface spectroscopic method measures the energy of the Doppler shifted annihilation gamma photon in coincidence with the Auger electron emitted following the relaxation of the hole created by the annihilation of a surface electron with a surface trapped positron. By extracting and theoretically modelling the annihilation gamma spectra coincident with low energy electrons, we associate majority of the intensity in the low energy (7 eV–25 eV) region of the Auger spectrum to electron emission following Auger decays of 2s holes in adsorbed oxygen and deep valence holes in graphene. We provide additional support to this conclusion by showing that most of the Auger electrons with energy less than ~ 25 eV are coincident with gamma photons with small Doppler shift (511 keV–512 keV) indicating that the primary electron whose annihilation resulted in low energy Auger electron emission had small momentum parallel to the gamma emission direction. On the other hand, majority of the Auger electrons measured in coincidence with the photons having maximum Doppler shift (515 keV–521 keV) were emitted following the decay of core holes (C 1s and O 1s). Furthermore, by selecting annihilation gamma photons coincident only with the O KVV (from surface adsorbed oxygen), C KVV (graphene), and Cu MVV (copper substrate) Auger electrons, we have also experimentally derived the energy spectrum of Doppler shifted gamma photons resulting from the annihilation of positrons with 1s electrons of O, 1s electrons of C and 3p electrons of Cu respectively. Model Doppler broadened gamma spectra produced using ab-initio calculations agree well with the experimentally derived line shapes. This demonstrates the ability of Auger-gamma coincidence method to experimentally resolve the Doppler broadened annihilation gamma spectrum from surfaces into its veiled electronic level constituents which has, heretofore, relied solely on theoretical analysis. Our results also demonstrate that the line shape of the Doppler broadened annihilation gamma peak reflect the chemical composition of the topmost atomic layer and can thus be used to characterize both external and inaccessible surfaces of porous materials.
Nuclear reactors that rely upon the fission reaction have two modes of thermal energy deposition in the reactor system: neutron absorption and gamma absorption. The gamma rays are typically generated by neutron capture reactions or during the fission process which means the primary driver of energy production is of course the neutron interactions. The GAMSOR program was first built in the mid 1980s to properly account for the gamma heating in an operating reactor core on core internals. The GAMSOR code is sequence of DIF3D calculations to compute the neutron and gamma flux and combine them to define both the neutron and gamma heating throughout the modeled domain. The goal of this manuscript is to present the software verification of GAMSOR. The first step of the GAMSOR sequence of calculations involves of a modified version of DIF3D (called DIF3D-GAMSOR) which generates a gamma source distribution for the follow-on DIF3D gamma transport calculation (step 2). This modified version of DIF3D increases the burden of maintenance and verification work on GAMSOR as one must reverify the DIF3D capabilities which is undesirable. Because the calculation of the gamma source is the only unique aspect of GAMSOR beyond the regular DIF3D capabilities, that part was put in a standalone code called GAMSRC such that one can use the verified DIF3D code in step 1 followed by GAMSRC to carry out the same GAMSOR calculation step. As a consequence, this manuscript is focused on verification of the gamma source files generated by GAMSRC. The verification of the modified version of DIF3D (DIF3D-GAMSOR) will be done less rigorously in that it will be verified that it produces the same output that GAMSRC does and thus GAMSRC is equivalent to GAMSOR on the problems studied here. Hand calculations and independent numerical calculations of the gamma source generation are used for the verification work. This work follows the same methodology of GAMSRC. As expected, the results agree well with those calculated by GAMSRC as will be shown.
Nuclear reactors that rely upon the fission reaction have two modes of thermal energy deposition in the reactor system: neutron absorption and gamma absorption. The gamma rays are typically generated by neutron capture reactions or during the fission process which means the primary driver of energy production is of course the neutron interactions. The GAMSOR program was first built in the mid 1980s to properly account for the gamma heating in an operating reactor core on core internals. The GAMSOR code is sequence of DIF3D calculations to compute the neutron and gamma flux and combine them to define both the neutron and gamma heating throughout the modeled domain. The goal of this manuscript is to present the software verification of GAMSOR. The first step of the GAMSOR sequence of calculations involves of a modified version of DIF3D (called DIF3D-GAMSOR) which generates a gamma source distribution for the follow-on DIF3D gamma transport calculation (step 2). This modified version of DIF3D increases the burden of maintenance and verification work on GAMSOR as one must reverify the DIF3D capabilities which is undesirable. Because the calculation of the gamma source is the only unique aspect of GAMSOR beyond the regular DIF3D capabilities, that part was put in a standalone code called GAMSRC such that one can use the verified DIF3D code in step 1 followed by GAMSRC to carry out the same GAMSOR calculation step. As a consequence, this manuscript is focused on verification of the gamma source files generated by GAMSRC. The verification of the modified version of DIF3D (DIF3D-GAMSOR) will be done less rigorously in that it will be verified that it produces the same output that GAMSRC does and thus GAMSRC is equivalent to GAMSOR on the problems studied here. Hand calculations and independent numerical calculations of the gamma source generation are used for the verification work. This work follows the same methodology of GAMSRC. As expected, the results agree well with those calculated by GAMSRC as will be shown.
The measurement of diffuse PeV gamma-ray emission from the Galactic plane would provide information about the energy spectrum and propagation of Galactic cosmic rays, and the detection of a pointlike source of PeV gamma-rays would be strong evidence for a Galactic source capable of accelerating cosmic rays up to at least a few PeV. This paper presents several unbinned maximum-likelihood searches for PeV gamma-rays in the Southern Hemisphere using 5 yr of data from the IceTop air shower surface detector and the in-ice array of the IceCube Observatory. The combination of both detectors takes advantage of the low muon content and deep shower maximum of gamma-ray air showers and provides excellent sensitivity to gamma-rays between ~0.6 and 100 PeV. Our measurements of pointlike and diffuse Galactic emission of PeV gamma-rays are consistent with the background, so we constrain the angle-integrated diffuse gamma-ray flux from the Galactic plane at 2 PeV to 2.61 × 10 -19 cm -2 s -1 TeV -1 at 90% confidence, assuming an E -3 spectrum, and we estimate 90% upper limits on pointlike emission at 2 PeV between 10 -21 and 10 -20 cm -2 s -1 TeV -1 for an E -2 spectrum, depending on decl. Furthermore, we exclude unbroken power-law emission up to 2 PeV for several TeV gamma-ray sources observed by the High Energy Spectroscopic System and calculate upper limits on the energy cutoffs of these sources at 90% confidence. We also find no PeV gamma-rays correlated with neutrinos from IceCube's high-energy starting event sample. Lastly, these are currently the strongest constraints on PeV gamma-ray emission.
There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.