Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

ON WEAK REDSHIFT DEPENDENCE OF GAMMA-RAY SPECTRA OF DISTANT BLAZARS

Line-of-sight interactions of cosmic rays provide a natural explanation of the hard gamma-ray spectra of distant blazars, which are believed to be capable of producing both gamma rays and cosmic rays. For sources with redshifts z {approx}> 0.1, secondary gamma rays produced in cosmic-ray interactions with background photons close to an observer can dominate over primary gamma rays originating at the source. The transition from one component to another is accompanied by a change in the spectral index depending on the source redshift. We present theoretical predictions and show that they agree with the data from Fermi Large Area Telescope. This agreement, combined with the spectral data from Atmospheric Cherenkov Telescopes, provides evidence of cosmic-ray acceleration by active galactic nuclei and opens new opportunities for studying photon backgrounds and intergalactic magnetic fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of Gamma-Ray-Spectra Analysis Method Utilizing the Fireworks Algorithm for Various Error Measures

The analysis of measured data plays a significant role in enhancing nuclear nonproliferation mainly by inferring the presence of patterns associated with special nuclear materials. Among various types of measurements, gamma-ray spectra is the widest utilized type of data in nonproliferation applications. In this paper, a method that employs the fireworks algorithm (FWA) for analyzing gamma-ray spectra aiming at detecting gamma signatures is presented. In particular, FWA is utilized to fit a set of known signatures to a measured spectrum by optimizing an objective function, where non-zero coefficients express the detected signatures. FWA is tested on a set of experimentally obtained measurements optimizing various objective functions—MSE, RMSE, Theil-2, MAE, MAPE, MAP—with results exhibiting its potential in providing highly accurate and precise signature detection. Finally and furthermore, FWA is benchmarked against genetic algorithms and multiple linear regression, showing its superiority over those algorithms regarding precision with respect to MAE, MAPE, and MAP measures.

97 MATHEMATICS AND COMPUTING↗

Draft Specification for Representing Gamma Radiation Spectra in QR codes

This document defines a proposed specification for representing gamma radiation spectra, as commonly produced by handheld Radioisotope Identifiers, as a QR code, or as a Uniform Resource Identifier (URI). The intended primary application is transferring spectra between locations or devices using standard smart-phone capabilities when data transmission would otherwise be challenging or not possible. The proposed encoding also enables embedding of spectra within other documents as hyperlinks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monitoring Aqueous Reprocessing Systems for Detection of Facility Misuse

Traditional approaches to material control and accounting at used nuclear fuel reprocessing facilities relies in large part on laboratory-based destructive assay of periodic samples taken from key stages. These techniques are highly accurate, but limited inspection frequency may limit the size and operation of a reprocessing facility. Online monitoring techniques using inline detectors can be applied to fuel reprocessing systems to improve the situational awareness as the facility is operating to provide additional indicators of the evolving state of the facility between normal inspection periods, potentially alerting regulators to the need for additional inspection. The Multi-Isotope Process (MIP) Monitor combines medium-resolution gamma detectors with statistical data analysis techniques to monitor reprocessing systems for anomalous conditions resulting from process control issues or malfeasance. Gamma spectra collected from the H-Canyon reprocessing facility were modeled using principal component analysis to demonstrate the efficacy of the MIP Monitor for detecting notional diversion scenarios.

safeguards, nuclear fuel reprocessing, gamma spect↗

IDB Loader

SAND2024-08428O The IDB Loader is a database designed to hold gamma spectra. IDB is a web-accessible database of reference gamma spectra for measuring uranium (U) and plutonium (Pu) isotopic composition. The database, developed by the International Atomic Energy Agency (IAEA), provides access to well-characterized groups of gamma spectra curated by international experts in gamma spectroscopy. It was created to promote sustainability and maintenance of software used to determine the isotopic abundances of U and Pu. The IDB Loader works by uploading one set of spectral data into an existing IDB. The Data Loader package includes documentation describing the IDB's table, the format of the spectral data, and a description of the loader program. The IDB is currently hosted by the IAEA at: https://nds.iaea.org/idb Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Schwartz, Steven↗

Short-lived fission product measurements from >0.1 MeV neutron-induced fission using boron carbide.

A boron carbide shield was designed, custom fabricated, and used to create a fast fission energy neutron spectrum. The fissionable isotopes 233, 235, 238U, 237Np, and 239Pu were separately placed inside of this shield and irradiated under pulsed conditions at the Washington State University 1 MW TRIGA reactor. A unique set of fission product gamma spectra were collected at short times (4 minutes to 1 week) post-fission. Gamma spectra were collected on single-crystal high purity germanium detectors and on Pacific Northwest National Laboratory's (PNNL's) Direct Simultaneous Measurement (DSM) system composed of HPGe detectors connected in coincidence. This work defines the experimental methods used to produce and collect the gamma data, and demonstrates the validity of the measurements. It is important to fully document this information so the data can be used with high confidence for the advancement of nuclear science and non-proliferation applications. The gamma spectra collected in these and other experiments will be made publicly available at https://spcollab.pnl.gov/sites/gammadata or via the link at http://rdnsgroup.pnl.gov. A revised version of this publication will be posted with the data to make the experimental details available to those using the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 238U neutron-capture cross section and gamma-emission spectra from 10 eV to 100 keV using the DANCE detector at LANSCE

A careful new measurement of the {sup 238}U(n,{gamma}) cross section from 10 eV to 100 keV has been made using the DANCE detector at LANSCE. DANCE is a 4{pi} calorimetric scintillator array consisting of 160 BaF{sub 2} crystals. Measurements were made on a 48 mg/cm{sup 2} depleted uranium target. The cross sections are in general good agreement with previous measurements. The gamma-ray emission spectra, as a function of gamma multiplicity, were also measured and compared to model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A heuristic approach to rapid, automatic identification of uranium in high-resolution gamma-ray spectra

Our rule-based expert system, HPGe ID, is used to rapidly and automatically identify well over 200 radioactive sources in less than one second from their gamma-ray signatures in high-resolution gamma-ray spectra. One of the most important sources, uranium, is the most complex in terms of natural or processed form, enrichment grade, and even reactor fuel cycle. To determine these attributes, HPGe ID does not require knowledge of the detector efficiency, the source-to-detector distance, or the geometry of the inspected radiation source—including any shielding. Here we discuss the approach taken with HPGe ID to detect and determine these uranium attributes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Imprint of the Extragalactic Background Light in the Gamma-Ray Spectra of Blazars

The light emitted by stars and accreting compact objects through the history of the universe is encoded in the intensity of the extragalactic background light (EBL). Knowledge of the EBL is important to understand the nature of star formation and galaxy evolution, but direct measurements of the EBL are limited by galactic and other foreground emissions. In this paper, we report an absorption feature seen in the combined spectra of a sample of gamma-ray blazars out to a redshift of z ~ 1.6. Finally, this feature is caused by attenuation of gamma rays by the EBL at optical to ultraviolet frequencies and allowed us to measure the EBL flux density in this frequency band.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid, autonomous analysis of HPGe gamma-ray spectra III: Plutonium identification and characterization

RadID is a gamma-ray spectrum analysis program originally written to assist in the detection of the illicit movement of nuclear material. It is specific to the rapid analysis of HPGe gamma-ray data to reveal the radionuclide signatures of interest that may be present in the spectra. It is an autonomous, rule-based heuristic system that can identify well over 200 radioactive sources in about one second. RadID does not require knowledge of the detector efficiency, the source-todetector distance, or the geometry of the inspected radiation source—including any shielding. In this third of a three-document series we discuss how RadID detects the presence of plutonium isotopes and determines a number of its characteristics, most notably: the spectral characteristics of weapons-grade plutonium, reactor-grade plutonium, and heat-source plutonium used in radioisotope thermoelectric generators.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Criticality Accident Alarm System Shielding Benchmark: Integral Experiment Request 498, Critical Engineering Decision 1 Report

This report supports Critical/Subcritical Experiment Decision 1 (CED-1) for Integral Experiment Request (IER) 498, a shielding benchmark produced using the Godiva IV critical assembly at the National Critical Experiments Research Center (NCERC). Shielding benchmarks are datasets collected to provide a comparison for computer models that simulate the effect of shielding on radiation transmission from a source to a detector. The purpose of a CED-1 report is to produce a conceptual design for an integral experiment and to identify the long lead-time items. The design presented in this report favors certain detailed design options such as material selections. However, alternative options can be selected as the project evolves. Dimensions are specified only as needed to evaluate feasibility and performance. Development of Criticality Accident Alarm System (CAAS) shielding benchmarks supports two main programmatic needs. The first need is to improve confidence in models of facilities that house nuclear material handling operations. Better models can support effective CAAS detector placement when criticality may result in dose, and it enables more accurate analysis of criticality accident impacts at various locations in a facility. A key quantity that can be verified is the secondary gamma production caused by neutron interactions with various materials. The second programmatic need supported by shielding benchmarks is the ongoing development of methods being integrated into nuclear simulation codes such as the Monte Carlo N-Particle (MCNP) transport code and the SCALE code system used in efforts funded by the Nuclear Criticality Safety Program (NCSP). Previous work performed under the International Criticality Safety Benchmark Experimental Program (ICSBEP) to produce shielding benchmark data is primarily limited to a set of measurements at the SILENE critical assembly at the Valduc facility in France. The experiment used an open configuration and a burst mode operation, which limited detector options to thermoluminescent dosimeters (TLDs) and activation foils. Because TLDs do not record gamma spectra, it was difficult to verify the gamma energy spectrum from the experiment. In this work, the Godiva IV assembly will be used because it is a fast system capable of producing a wide range of source strengths, including super-prompt critical bursts. The room return for the facility is expected to be substantial and challenging to characterize, so a more closed, shielded experimental configuration is considered. Furthermore, because the physics of radiation transport outside the assembly does not change between the burst mode and the delayed critical mode, it is anticipated that most measurements will be made with the Godiva IV assembly in delayed critical mode, operating within a range that will allow electronic counters to collect accurate data. Scoping calculations concluded that a workable room return shield is comprised of 40 cm of 5% borated polyethylene backed by 7 cm of lead. This configuration was shown to produce a ratio of signal–to–room return of over 100 for up to 2 mean free paths of shield sample material, and over 10 for up to 4 mean free paths of shield sample material, ensuring that useful results can be obtained. With no shielding sample in the room return shield, it was shown that the neutron and gamma spectra do not appreciably change with a change in room size. This scoping calculation does not preclude the use of tungsten powder in a binder, some other effective gamma shielding material, or a hybrid design. Dose rates for various source intensities at an unshielded detector are listed herein to inform detector selection during CED-2, and calibration chains are identified. Preliminary estimates of costs and schedules are outlined but remain to be verified. Values could double or triple as estimates become more accurate and are principally included here to demonstrate feasibility. Preliminary estimates indicate that the apparatus can be installed within a feasible schedule and budget. Two measurements per day are assumed. Producing a shielding benchmark at NCERC using the Godiva IV assembly has been shown to be feasible, with manageable uncertainties and risks. A clear, continuing need for shielding benchmark data remains present, and this report identifies and evaluates a method for creating integrated shielding benchmark datasets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Anomaly Detection Algorithms for Field-Acquired Gamma Energy Spectra

The Remote Sensing Laboratory (RSL) is developing a tactical, networked radiation detection system that will be agile, reconfigurable, and capable of rapid threat assessment with a high degree of fidelity and certainty. Our design is driven by the needs of users such as law enforcement personnel who must make decisions by evaluating threat signatures in urban settings. The most efficient tool available to identify the nature of the threat object is real-time gamma spectroscopic analysis, as it is fast and has a very low probability of producing false positive alarm conditions. Urban radiological searches are inherently challenged by the rapid and large spatial variation of background gamma radiation, the presence of benign radioactive materials in terms of the normally occurring radioactive materials (NORM), and shielded and/or masked threat sources. Multiple spectral anomaly detection algorithms have been developed by national laboratories and commercial vendors. For example, the Gamma Detector Response and Analysis Software (GADRAS) a one-dimensional deterministic radiation transport software capable of calculating gamma ray spectra using physics-based detector response functions, was developed at Sandia National Laboratories. The nuisance-rejection spectral comparison ratio anomaly detection algorithm (or N-SCRAD), developed at Pacific Northwest National Laboratory, uses spectral comparison ratios to detect deviation from benign medical and NORM radiation source and can work in spite of strong presence of NORM and or medical sources. RSL has developed its own wavelet-based gamma energy spectral anomaly detection algorithm called WAVRAD. Test results and relative merits of these different algorithms will be discussed and demonstrated.

networked sensor, gamma spectroscopy, false alarm ↗

Data-Driven Performance Optimization of Gamma Spectrometers With Many Channels

In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe (CZT) spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in non-destructive assay (NDA) for nuclear safeguards, and explore trends in performance versus parameters such as clustering algorithm type. We also compare the NMF + clustering pipeline to several non-machine-learning (ML) algorithms, including several greedy algorithms. Although, we find that the NMF + clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the unoptimized spectra, but that a greedy accumulation of spectra segmented by detector depth can, in some cases, give similar performance improvements in much less computation time.

Energy resolution↗

An automated isotope identification and quantification algorithm for isotope mixtures in low-resolution gamma-ray spectra

There is a need to develop an automated isotope identification and quantification algorithm that can perform well using low-resolution gamma-ray detectors. The algorithm should be able to perform well on spectra that contain a mixture of many isotopes as well as in cases where spectral features are difficult to analyze. Due to the low resolution of these detectors, spectra of isotope mixtures becomes complicated to identify when features overlap. Previous research applying machine learning algorithms to isotope identification has been promising. Further work is needed to demonstrate the limits of machine learning algorithms when applied to identifying mixtures of isotopes and spectra where features are not obvious. Because machine learning algorithms use abstract features of the spectrum, such as the shape of overlapping peaks and Compton continuum, they are a natural choice for analyzing isotope mixtures. In this work, an artificial neural network (ANN) has be trained to calculate the relative activities of 29 isotopes in a spectrum. The ANN is trained with simulated gamma-ray spectra, allowing custom datasets to be generated for specific identification tasks. The algorithms performance on simulated spectra without apparent features and on simulated isotope mixtures are both analyzed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A laser-induced repetitive fast neutron source applied for gold activation analysis

A laser-induced repetitively operated fast neutron source was developed for applications in laser-driven nuclear physics research. The developed neutron source, which has a neutron yield of approximately 4 Multiplication-Sign 10{sup 5} n/pulse and can be operated up to a pulse repetition rate of 10 Hz, was applied for a gold activation analysis. Relatively strong delayed gamma spectra of the activated gold were measured at 333 keV and 355 keV, and proved the possibility of the neutron source for activation analyses. In addition, the nuclear reactions responsible for the measured gamma spectra of gold were elucidated by the 14 MeV fast neutrons resulting from the D(t,n)He{sup 4} nuclear reaction, for which the required tritium originated from the primary fusion reaction, D(d,p)T{sup 3}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rapid, autonomous analysis of HPGe gamma-ray spectra II: Uranium identification and characterization

RadID is a gamma-ray spectrum analysis program originally written to assist in the detection of the illicit movement of nuclear material. In this second of the three-document series we discuss how RadID detects the presence of uranium isotopes and determines a number of its characteristics, most notably or processed material and enriched estimates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single crystals of (FeIn{sub 2}S{sub 4}){sub x} · (CuIn{sub 5}S{sub 8}){sub 1–x} alloys: Crystal structure, nuclear gamma resonance spectra, and thermal expansion

FeIn{sub 2}S{sub 4} and CuIn{sub 5}S{sub 8} compounds and (FeIn{sub 2}S{sub 4}){sub x} · (CuIn{sub 5}S{sub 8}){sub 1–x} alloy single crystals are grown by planar crystallization. It is shown that both of the initial FeIn{sub 2}S{sub 4} and CuIn{sub 5}S{sub 8} compounds and alloys on their basis crystallize with the formation of the cubic spinel structure. It is established that the unit-cell parameter a linearly varies with the composition parameter x. By means of nuclear gamma resonance spectroscopy in the transmission mode of measurements, the local states of iron ions in the alloys are studied. For the single crystals grown in the study, thermal expansion is explored using the dilatometry technique, the thermal-expansion coefficients are determined, and the Debye temperature and rms (root-mean-square) dynamic displacements are calculated.

36 MATERIALS SCIENCE↗