Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAS CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Measuring Solvation Interactions of Deep Eutectic Solvents Formed by Metal Chlorides and an Imidazolium Salt by Inverse Gas Chromatography

Deep eutectic solvents (DESs) represent a class of solvents that offer a number of advantages including minimal toxicity, affordability, low vapor pressure, and simple, environmentally friendly preparation methods. They have found utility in areas, such as gas absorption, metal plating, and extractions. However, the relationship between their solvation properties and chemical composition remains poorly understood. In this study, a broad range of Type I DESs composed of metal chlorides and an imidazolium salt were prepared, employed as gas chromatographic stationary phases, and characterized using the Abraham solvation parameter model by inverse gas chromatography. The Abraham solvation parameter model allows for the study of DES solvation properties and the effects of varying structural components on system constants using a linear-free energy relationship. The DESs were investigated by systematically varying their composition, including the type of metal chloride and the molar ratio between the metal chloride and the imidazolium salt. The results show that hydrogen bond acidity, hydrogen bond basicity, and dipolarity/polarizability interactions are strongly influenced by the type of metal chloride within the DES and the ratio of metal chloride to imidazolium salt in the eutectic mixture. Furthermore, a column pretreatment procedure is presented that enables the effective coating of highly polar DESs onto open tubular capillary gas chromatography columns.

deep eutectic solvent↗

Development of a Gas Chromatography with High-Resolution Time-of-Flight Mass Spectrometry Methodology for BDNPA/F

Analysis of thermally labile compounds such as bis(2,2-dinitropropyl) acetal/formal (BDNPA/F), an energetic plasticizer, is usually performed via liquid chromatography (LC) as opposed to gas chromatography (GC) due to thermal decomposition in the inlet or the analytical column. While LC is a powerful technique, the analysis of volatile and semivolatile compounds is best suited to GC. Herein, a method was developed for a gas chromatograph coupled to high-resolution mass spectrometer (GC-HRMS), utilizing a programmable temperature vaporizer (PTV) inlet. A subset of the native compounds and several produced by the thermal decomposition of BDNPA/F in the inlet were evaluated by using multiple PTV inlet parameters to determine the optimal ramp rate and final temperature of the inlet (60 °C/min from 60 to 325 °C). The optimized GC-HRMS method nearly reduced all thermal decomposition, allowing for an excellent separation to be obtained. Furthermore, multiple ionization methods, including electron impact (EI), negative chemical ionization (NCI), and positive chemical ionization (PCI), were used to explore the many chemical differences between the BDNPA/F samples. A preliminary investigation of the benefits of using GC-HRMS to evaluate the chemical differences between unaged and aged BDNPA/F samples for unique insight was evaluated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas chromatography: Possible application of advanced instrumentation developed for solar system exploration to space station cabin atmospheres

Gas chromatography (GC) technology was developed for flight experiments in solar system exploration. The GC is a powerful analytical technique with simple devices separating individual components from complex mixtures to make very sensitive quantitative and qualitative measurements. It monitors samples containing mixtures of fixed gases and volatile organic molecules. The GC was used on the Viking mission in support of life detection experiments and on the Pioneer Venus Large Probe to determine the composition of the venusian atmosphere. A flight GC is under development to study the progress and extent of STS astronaut denitrogenation prior to extravehicular activity. Advanced flight GC concepts and systems for future solar system exploration are also studied. Studies include miniature ionization detectors and associated control systems capable of detecting from ppb up to 100% concentration levels. Further miniaturization is investigated using photolithography and controlled chemical etching in silicon wafers. Novel concepts such as ion mobility drift spectroscopy and multiplex gas chromatography are also developed for future flight experiments. These powerful analytical concepts and associated hardware are ideal for the monitoring of cabin atmospheres containing potentially dangerous volatile compounds.

Carle, G. C.↗

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]↗

Capillary gas chromatography with two new moderately high temperature phases.

Gas chromatography test results are presented for two new moderately high-temperature phases of Dexsil 400-GC with free hydroxyl end groups (uncapped) and with end groups covered by trimethyl silyl groups (capped). The two Dexsil 400-GC phases were tested for their ability to resolve N-TFA-DL-(+)-2-butyl esters and n-butyl esters, as well as fatty acid methyl esters and hydrocarbon standards. Generally the more polar uncapped phase was superior to the capped phase in all separation comparisons, except for the hydrocarbons.

Pollock, G. E.↗

Physicochemical Gas–Solid Sorption Properties of Geologic Materials Using Inverse Gas Chromatography

The goal of this study was to determine the physicochemical properties of a variety of geologic materials using inverse gas chromatography (IGC) by varying probe gas selection, temperature, carrier gas flow rate, and humidity. This is accomplished by measuring the level of interaction between the materials of interest and known probe gases. Identifying a material’s physicochemical characteristics can help provide a better understanding of the transport of gaseous compounds in different geologic materials or between different geological layers under various conditions. Our research in this study focused on measuring the enthalpy (heat) of adsorption, Henry’s constant, and diffusion coefficients of a suite of geologic materials, including two soil types (sandy clay-loam and loam), quartz sand, salt, and bentonite clay, with various particle sizes. The reproducibility of IGC measurements for geologic materials, which are inherently heterogeneous, was also assessed in comparison to the reproducibility for more homogeneous synthetic materials. This involved determining the variability of physicochemical measurements obtained from different IGC approaches, instruments, and researchers. For the investigated IGC-determined parameters, the need for standardization became apparent, including the need for application-relevant reference materials. The inherent physical and chemical heterogeneities of soil and many geologic materials can make the prediction of sorption properties difficult. Characterizing the properties of individual organic and inorganic components can help elucidate the primary factors influencing sorption interactions in more complex mixtures. This research examined the capabilities and potential challenges of characterizing the gas sorption properties of geologic materials using IGC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hot-wire detector for chemically active materials used in gas chromatography

Hot-filament detector analyzes chemically active materials used in gas chromatography. The detector reacts chemically with the effluent vapors in the gas chromatographic apparatus to change the electrical resistance of the filament as a function of the affluent composition. Due to the changes produced by chemical action on the filament, the system is often calibrated.

Source record↗

Highly crosslinked silicon polymers for gas chromatography columns

A new highly crosslinked silicone polymer particle for gas chromatography application and a process for synthesizing such copolymer are described. The new copolymer comprises vinyltriethoxysilane and octadecyltrichlorosilane. The copolymer has a high degree of crosslinking and a cool balance of polar to nonpolar sites in the porous silicon polymer assuring fast separation of compounds of variable polarity.

Shen, Thomas C.↗

Miniaturized GC/MS instrumentation for in situ measurements: micro gas chromatography coupled with miniature quadrupole array and paul ion trap mass spectrometers

Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.

GC/MC miniature mass spectrometry MEMS↗

In Situ Analysis of Martian Regolith with the SAM Experiment During the First Mars Year of the MSL Mission: Identification of Organic Molecules by Gas Chromatography from Laboratory Measurements

The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover, is specifically designed for in situ molecular and isotopic analyses of martian surface materials and atmosphere. It contributes to the Mars Science Laboratory (MSL) missions primary scientific goal to characterize the potential past, present or future habitability of Mars. In all of the analyses of solid samples delivered to SAM so far, chlorinated organic compounds have been detected above instrument background levels and identified by gas chromatography coupled to mass spectrometry (GC-MS) (Freissinet et al., 2015; Glavin et al., 2013). While some of these may originate from reactions between oxychlorines and terrestrial organic carbon present in the instrument background (Glavin et al., 2013), others have been demonstrated to originate from indigenous organic carbon present in samples (Freissinet et al., 2015). We present here laboratory calibrations that focused on the analyses performed with the MXT-CLP GC column (SAM GC-5 channel) used for nearly all of the GC-MS analyses of the martian soil samples carried out with SAM to date. Complementary to the mass spectrometric data, gas chromatography allows us to separate and identify the species analyzable in a nominal SAM-GC run time of about 21 min. To characterize the analytical capabilities of this channel within the SAM Flight Model (FM) operating conditions on Mars, and their implications on the detection of organic matter, it is required to perform laboratory experimental tests and calibrations on spare model components. This work assesses the SAM flight GC-5 column efficiency, confirms the identification of the molecules based on their retention time, and enables a better understanding of the behavior of the SAM injection trap (IT) and its release of organic molecules. This work will enable further optimization of the SAM-GC runs for additional samples to be analyzed during the MSL mission.

analysis↗

Crosslinked polymeric ionic liquid stationary phases incorporating a combination of silver(I) and copper(II) ions for olefin separations by gas chromatography

The development of efficient and selective olefin separation technologies is a critical challenge within the chemical industry given the high energy demands of conventional cryogenic distillation methods. To address this, the study explores the effectiveness of polymeric ionic liquid (PIL) stationary phases in gas chromatography (GC) that incorporate both silver(I) ([Ag + ]) and copper(II) ([Cu 2+ ]) ions for enhanced olefin separation via π-complexation interactions. Further, the effects of both non-crosslinked and crosslinked PIL stationary phases containing varying ratios of [Ag⁺] and [Cu²⁺] ions were systematically investigated to evaluate their impact on the separation of olefins from paraffins and structurally similar olefins. Retention measurements using a broad range of olefinic probes revealed that [Ag⁺] ions provided stronger and more consistent π-complexation in PIL-based stationary phases, while [Cu²⁺] ions preferentially enhance olefin retention in crosslinked systems. Furthermore, thermal stability studies showed that [Ag + ]-containing PIL stationary phases maintain stable olefin separation efficiency over prolonged exposure under elevated temperatures, while crosslinked PIL stationary phases containing [Cu 2+ ] ions exhibited stronger retention due to increased surface adsorption. These findings provide insight into the tunability of metal–olefin interactions using PIL-based stationary phases and suggest design strategies for achieving thermally stable and highly selective chromatographic separations of unsaturated hydrocarbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metal-Organic Framework Thin Films as Stationary Phases in Microfabricated Gas-Chromatography Columns.

The overarching goal of this project is to integrate Sandia's microfabricated gas-chromatography ( GC) columns with a stationary phase material that is capable of retaining high-volatility chemicals and permanent gases. The successful integration of such a material with GCs would dramatically expand the repertoire of detectable compounds for Sandia's various microanalysis systems. One such promising class of candidate materials is metal-organic frameworks (MOFs). In this report we detail our methods for controlled deposition of HKUST-1 MOF stationary phases within GC columns. We demonstrate: the chromatographic separation of natural gas; a method for determining MOF film thickness from chromatography alone; and the first-reported GC x GC separation of natural gas -- in general -- let alone for two disparate MOF stationary phases. In addition we determine the fundamental thermodynamic constant for mass sorption, the partition coefficient, for HKUST-1 and several light hydrocarbons and select toxic industrial chemicals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗