Search NASA⌕ Search

SEARCH · Search NASA

Results for “GASKET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

Toilet↗

Heat and Pressure Seal for Doors

Proposed tubular gasket for doors performs dual function: seals in pressure, and seals out heat. Composed of quartz fabric filled with alumina matting, gasket is bonded with room-temperature-vulcanizing material to periphery of door. When door is closed, gasket is compressed like O-ring: fills gap between door and frame; and prevents leakage of air and heat.

Gillespie, C. A.↗

Hermetic edge sealing of photovoltaic modules

The feasibility of using an electrostatic bonding (ESB) and ultrasonic welding process to produce hermetic edge seals on terrestrial solar cell modules was investigated. The fabrication sequence is to attach an aluminum foil "gasket' to the perimeter of a glass sheet. A cell circuit is next encapsulated inside the gasket, and its aluminum foil back cover is seam welded ultrasonically to the gasket. An ESB process for sealing aluminum to glass was developed in an ambient air atmosphere, which eliminates the requirement for a vacuum or pressure vessel. An ultrasonic seam welding process was also developed which did not degrade the quality of the ESB seal. Good quality welds with minimal deformation were produced. The effectiveness of the above described sealing techniques was tested by constructing 400 sq cm (8 x 8 s64 sq in) sample modules, and then subjecting them to nondestructive fine and gross leak tests. The gross leak tests identified several different causes of leaks which were then eliminated by modifying the assembly process.

Nowlan, M. J.↗

Helium Balloon Valve Improvement

The NASA Balloon Program Office (BPO), located at Wallops Flight Facility asked the Mechanical Systems Branch (Code 548) to improve the design of their balloon valve. BPO uses two main types of balloons, Zero Pressure Balloon (ZPB) and Super Pressure Balloon (SPB), which both use the valve. It is used for termination of the ZPB, and inflation and termination of the SPB. During launch campaigns the valve showed signs of helium leakage which lead the BPO to ask for an improvement. As part of a Professional Readiness Engineering Program (PREP), research and review of the current valve was conducted and a new design was prepared. The current custom designed valve consists of a "pie" plate that is actuated up and down via a gear rack that is driven by a globe motor. When closed the knife edge of the pie plate bites into a silicone gasket to seal the structure. Unfortunately, the gasket material permanently deforms after being compressed and the plate itself bends under the force induced by the motor, introducing two possible helium leak paths. The new custom designed valve utilizes o-rings instead of one gasket to reduce the possibility of leakage from permanent deformation. One o-ring seals the valve structure to its mating surface and a spring energized o-ring is used in a piston design to seal the valve once it's closed. The design also utilizes different materials to increase stiffness and strength so that it is less likely to bend under the force from the motor. Currently the new valve has finished the design and analysis phases and is proceeding towards manufacturing and testing.

Seo, Lindsey↗

Redesign of Nuclear Material Storage Container with Additive Manufacturing

The goal of this project is to reduce worker dose and improve criticality safety by improving nuclear material storage containers. The current method of medium to long term (up to 15 years) storage of small amounts of nuclear material is to store it in a stainless-steel flat tube with a copper crush gasket. These containers use 10 bolts to fasten the lid, and the crush gasket must be replaced after every use. Stainless-steel acts as a gamma shield, but there is not any material to account for neutron dose. A redesign of this container should prioritize reducing radiation doses to handlers of the container by reducing the amount of time handlers are exposed to the container and introducing material with effective neutron and gamma shielding mechanics.

42 ENGINEERING↗

Liquid-hydrogen/nuclear-radiation resistant seals

Seal employs aromatic heterocyclic polymer, polyquinoxaline, and features resin starved laminate consisting of alternate layers of woven glass fabric and polymer film. Design gives gasket a mechanical spring characteristic, eliminating cold flow and resulting in elastic recovery when gasket is unloaded.

Van Auken, R.↗

Copper emissions from a high volume air sampler

High volume air samplers (hi vols) are described which utilize a brush-type electric motor to power the fans used for pulling air through the filter. Anomalously high copper values were attributed to removal of copper from the commutator into the air stream due to arcing of the brushes and recirculation through the filter. Duplicate hi vols were set up under three operating conditions: (1) unmodified; (2) gasketed to prevent internal recirculation; and (3) gasketed and provided with a pipe to transport the motor exhaust some 20 feet away. The results of 5 days' operation demonstrate that hi vols can suddenly start emitting increased amounts of copper with no discernible operational indication, and that recirculation and capture on the filter can take place. Copper levels found with hi vols whose exhaust was discharged at a distance downwind were among the lowest found, and apparently provides a satisfactory solution to copper contamination.

King, R. B.↗

Window with integral seal

Installation concept needed for airtight, watertight, laminated window does away with O-rings and sealants needed for effective edge seal. Pliable inner layer of laminating adhesive extends to form build-in gasket. Technique is usable for plastic or glass windows where space for gaskets and sealing rings is limited, canopies, and shields for military, marine, and land transportation vehicles.

Behar, J. M.↗

Pressure-Assisted Seal for Castings

Modification of widely used pressure-assisted gasket ensures tight seal even when one sealed surface somewhat rough or porous. Modified U-cross-section gasket has thin lips increasing sealing area and conform to slightly rough surface. Lips provide wider sealing area and extend highly loaded region at tip. Coating of polytetrafluoroethylene on tip and lip augments conformance.

Stuck, Donald E.↗

The stability of a sample in a diamond anvil cell

A theoretical analysis of the stability of a gasketed sample in a diamond anvil cell is reported, demonstrating that the stability of the sample depends principally on the yield strength and the thickness of the gasket, the bulk modulus and the radius of the sample, and the geometry of the culet. The results yield a simple methodology that can be used to obtain stable samples in a diamond anvil cell.

Moss, William C.↗

Igniter adapter-to-igniter chamber deflection test

Testing was performed to determine the maximum RSRM igniter adapter-to-igniter chamber joint deflection at the crown of the inner joint primary seal. The deflection data was gathered to support igniter inner joint gasket resiliency predictions which led to launch commit criteria temperature determinations. The proximity (deflection) gage holes for the first test (Test No. 1) were incorrectly located; therefore, the test was declared a non-test. Prior to Test No. 2, test article configuration was modified with the correct proximity gage locations. Deflection data were successfully acquired during Test No. 2. However, the proximity gage deflection measurements were adversely affected by temperature increases. Deflections measured after the temperature rise at the proximity gages were considered unreliable. An analysis was performed to predict the maximum deflections based on the reliable data measured before the detectable temperature rise. Deflections to the primary seal crown location were adjusted to correspond to the time of maximum expected operating pressure (2,159 psi) to account for proximity gage bias, and to account for maximum attach and special bolt relaxation. The maximum joint deflection for the igniter inner joint at the crown of the primary seal, accounting for all significant correction factors, was 0.0031 in. (3.1 mil). Since the predicted (0.003 in.) and tested maximum deflection values were sufficiently close, the launch commit criteria was not changed as a result of this test. Data from this test should be used to determine if the igniter inner joint gasket seals are capable of maintaining sealing capability at a joint displacement of (1.4) x (0.0031 in.) = 0.00434 inches. Additional testing should be performed to increase the database on igniter deflections and address launch commit criteria temperatures.

Cook, M.↗

Effect of Fuel Composition, Engine Operating Variables, and Spark-Plug Type and Condition on Preignition-Limited Performance of an R-2800 Cylinder

The preignition characteristics of the R-2800 cylinder, as effected by fuel consumption, engine operating variables, and spark plug type and condition, were evaluated. The effects on preignition-limited performance of various percentages of aromatics (benzene, toluene, cumene, xylene) in a base fuel of triptane were investigated. Two paraffins (triptane and S + 6.0 ml TEL/gal) and two refinery blends (28-R and 33-R) were preignition rated. The effect of changes in the following engine operating variables on preignition limit was determined: inlet-air temperature, rear spark plug gasket temperature, engine speed, spark advance, tappet clearance, and oil consumption. Preignition limits of the R-2800 cylinder using Champion C34S and C35S and AC-LS86, LS87, and LS88 spark plugs were established and the effect of spark plug deterioration was investigated. No definite trends in preignition-limited indicated mean effective pressure were indicated for aromatics as a class when increased percentages of different aromatics were added to a base fuel of triptane. Three types of fuel (aromatics, paraffins, and refinery blends) showed a preignition range for this cylinder from 65 to 104 percent when based on the performance of S plus 6.0 ml TEL per gallon as 100 percent. The R-2800 cylinder is therefore relatively insensitive to fuel composition when compared to a CFR F-4 engine, which had a pre-ignition range from 72 to 100 percent for the same fuels. Six engine operating variables were investigated with the following results: preignition-limited indicated mean effective pressure decreased, with increases in engine speed, rear spark plug gasket temperature, inlet-air temperature, and spark advance beyond 20 F B.T.C. and was unaffected by rate of oil consumption or by tappet clearance. Spark plugs were rated over a range of preignition-limited indicated mean effective pressure from 200 to 390 pounds per square inch at a fuel-air ratio of 0.07 in the following order of increased resistance to preignition: AC-LS97, AC-LS88, Champion C358, AC-LS86, and Champion C34S. Spark plug deterioration in the form of cracks in the porcelain had been broken away from the center electrode and were retained in the spark plug cavity, the preignition limit was decreased as much as 57 percent. When the broken pieces had been removed, the preignition limit increased from that of the undamaged porcelain as the weight of removed porcelain was increased.

Pfender, John F.↗

Enclosure for thermoelectric refrigerator and method

An enclosed structure is provided for use with a refrigerator having a door assembly. The enclosed structure preferably contains superinsulation materials and a plurality of matching drawers. The enclosed structure preferably includes corner joints which minimize thermal energy transfer between adjacent superinsulation panels. The refrigerator may include a cooling system having a thermoelectric device for maintaining the temperature within the refrigerator at selected values. If desired, a fluid cooling system and an active gasket may also be provided between the door assembly and the enclosed structure. The fluid cooling system preferably includes a second thermoelectric device to maintain the temperature of fluid flowing through the active gasket at a selected value. The drawers associated with the refrigerator may be used for gathering, processing, shipping and storing food or other perishable items.

Park, Brian V.↗

Hexavalent Chrome Free Coatings for Electronics Electromagnetic Interference (EMI) Shielding Effectiveness (SE) Interim Test Report

Test specimen configuration was provided by Parker Chomerics. The EMI gasket used in this project was Cho-Seal 6503E. Black oxide alloy steel socket head bolts were used to hold the plates together. Non-conductive spacers were used to control the amount of compression on the gaskets. The following test fixture specifications were provided by Parker Chomerics. The CHO‐TP09 test plate sets selected for this project consist of two aluminum plates manufactured to the specifications detailed in CHO­‐TP09. The first plate, referred to as the test frame, is illustrated in Figure 1. The test frame is designed with a cutout in the center and two alternating bolt patterns. One pattern is used to bolt the test frame to the corresponding test cover plate (Figure 2), forming a test plate set. The second pattern accepts the hardware used to mount the fully assembled test plate set to the main adapter plate (Figure 3).

trivalent chromium↗

Final Test Report: Hexavalent Chrome Free Coatings for Electronics Electromagnetic Interference (EMI) Shielding Effectiveness (SE)

The test results for Salt Spray Resistance, Static Heat and Humidity and Marine Environment can be found in Sections 3.1.3.3, 3.1.4.3 and 3.1.5.3 respectively. In summary, both the Metalast TCP and SurTec 650 Type 2 conversion coatings perform very similar to the incumbent Type 1 conversion coating against both 6061 and 5052 aluminum under all three test conditions. Significant prior work was performed to select the aluminum and conversion coating included within this test cycle; Reference - NASA GSDO Program Hexavalent Chrome Alternatives Final Pretreatments Test Report Task Order: NNH12AA45D September 01, 2013. As illustrated in the data, the 6061 aluminum panels SLIGHTLY out-performed the 5052 aluminum panels. Individual shielding effectiveness graphs for each panel are included within Appendix C and D. One other notable effect found during review of the data is that the Test Panels exposed to B117 Salt Fog reduced in shielding effectiveness significantly more than the Marine Environment Test Panels. The shielding effectiveness of the Marine Test Panels was approximately 20dB higher than the Test Panels that underwent B117 Salt Fog Exposure. The intent of this evaluation was not to maximize shielding effectiveness values. The same Parker Chomerics Cho-Seal 6503 gasket material was used for all panels with aluminum and conversion coating variants. A typical EMI gasket design for corrosive environments would be done quite differently. The intent was to execute a test that would provide the best possible evaluation of different aluminum materials and conversion coatings in corrosive environments. The test program achieved this intent. The fact that the two aluminums and two Type II conversion coatings performed similar to the incumbent Type 1 conversion coating is a positive outcome. It was desired to have an outcome that further differentiation the performance of two aluminum types and two conversion coating types but this could not be extracted by the test results. Further analysis of the test plates may be done by X-Ray Photoelectron Spectroscopy (XPS) or Electrochemical Impedance Spectroscopy (EIS). Feasibility of this is under review.

Kessel, Kurt R.↗