Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Detection of Anomalies in Gamma Background Radiation Data with K-Means and Self-Organizing Map Clustering Algorithms (Consortium on Nuclear Security Technologies (CONNECT) Q1 Report)

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. The challenge is that spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gamma radiation-induced defects in KCl, MgCl 2 , and ZnCl 2 salts at room temperature

Room temperature post-irradiation measurements of diffuse reflectance and electron paramagnetic resonance spectroscopies were made to characterize the long-lived radiation-induced species formed from the gamma irradiation of solid KCl, MgCl 2 , and ZnCl 2 salts up to 100 kGy. The method used showed results consistent with those reported for electron and gamma irradiation of KCl in single crystals. Thermal bleaching of irradiated KCl demonstrated accelerated disaggregation of defect clusters above 400 K, due to decomposition of Cl 3 - . The defects formed in irradiated MgCl 2 comprised a mixture of Cl 3 - , F-centers, and Mg + associated as M-centers. Further, Mg metal cluster formation was also observed at 100 kGy, in addition to accelerated destruction of F-centers above 20 kGy. Irradiated ZnCl 2 afforded the formation of Cl 2 - due to its high ionization potential and crystalline structure, which decreases recombination. The presence of aggregates in all cases indicates the high diffusion of radicals and the predominance of secondary processes at 295 K. Additionally, thermal bleaching studies showed that chloride aggregates’ stability increases with the ionization potential of the cation present. The characterization of long-lived radiolytic transients of pure salts provides important information for the understanding of complex salt mixtures under the action of gamma radiation.

36 MATERIALS SCIENCE↗

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation Aging of Cable Insulation Systems to Support Extension of Cable Electrical Assessment Techniques - CRADA 562 (Final Report)

Radiation aging (primarily gamma radiation) affects a small subset of the LV cable population based on a 40-year operation. Increasing plant operating life to 60 or 80 years will result in additional cables experiencing degradation, either from radiation or from combined thermal and radiation effects. Previous research work done by EPRI and other researchers focuses on electrical diagnostics of thermal effects. However, the electrical diagnostic response of the cable system to radiation aging is minimally understood. In order to study the electrical responses from XLPE and EPR cabling and correlate these responses with radiation dose and level of thermal exposure, gamma radiation testing was performed at Pacific Northwest National Laboratory (PNNL). This report covers the radiation testing performed at PNNL, which involved irradiation of 30-foot long cables and short witness samples. The cabling was irradiated, at room temperature, using cobalt-60 gamma-rays to intervals of 10 million rads (10 Mrads), for a maximum of 70 Mrads. The results can be used to determine cable conditions (extent of damage) more accurately and localize where the degradation exists along the length of the cable (axial location). These insights can provide operators with the options to focus repair, mitigation, or replacement efforts locally.

36 MATERIALS SCIENCE↗

Scintillator based nuclear photovoltaic batteries for power generation at microwatts level

A nuclear photovoltaic battery uses scintillator to convert radiation into visible light, which is then collected by a photovoltaic (PV) cell to generate electricity. If the radiation is gamma-rays emitted from external sources, the battery may also be referred as gammavoltaic battery. In this study, a polycrystalline CdTe solar cell was optically coupled with a 2.0 cm × 2.0 cm × 1.0 cm Gadolinium Aluminum Gallium Garnet (GAGG) scintillator, and the resulting device was tested using intense gamma radiation fields from a Cs-137 (1.5 kRad/h) and a Co-60 (10 kRad/h) irradiator. Measurements with Cs-137 provided a maximum power output (P max ) of ~288 nW, with a short-circuit current density (J sc ) of ~1.22 μA/cm 2 and an open-circuit voltage (V oc ) of ~0.34 V. In contrast, Co-60 irradiator gave a P max of 1.5 μW, with a J sc of ~4.73 μA/cm 2 and a V oc of ~0.38 V. The CdTe was also paired with a Lutetium-Yttrium Oxyorthosilicate (LYSO) crystal and tested with the Cs-137 source. The experiment presents a scalable option to reach to higher power outputs by harvesting gamma radiation fields in many cases where high radiation field demands heavy shielding and is often regarded as unwanted waste.

25 ENERGY STORAGE↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

Anomaly Detection in Gamma Spectra Using Hopfield Neural Network with B-SAT and Grover’s Algorithm on a Quantum Computing Simulator

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. In principle, gamma radiation sources can be detected and identified by their unique spectral lines. However, detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. In recent prior work, we have developed a Hopfield Neural Network (HNN) in conjunction with an image processing algorithm to detect a weak signal anomaly hidden among the highly fluctuating background spectra. The objective of this work is to explore quantum computing methods to increase the speed of HNN. The approach is based on the Grover’s search algorithm in conjunction with a 3-SAT problem formalism. The Grover’s algorithm is implemented on a quantum computing simulator using Qiskit software. Performance of HNN algorithm is benchmarked using search data from an environmental screening campaign, where the anomaly is a subset of measurements containing a 137 Cs source. Results indicate that using Grover’s algorithm on a quantum simulator reduces runtime of HNN by two orders of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flexible 3D printed silicones for gamma and neutron radiation shielding

Here, resin formulations for direct ink write (DIW) additive manufacturing (AM) were developed for facile customization to shield radiation signatures consisting of a range of gamma radiation and neutron energies in a variety of applications. The resin developed in this work has been formulated to accommodate very high loadings of shielding filler materials: up to 40 wt% bismuth (Bi) metal for gamma radiation shielding, and up to 60 wt% boron-10 ( 10 B) metal for neutron shielding. We report the first instance of a printable resin containing 60 wt% 10 B, which remains flexible after curing despite the high solids content. We demonstrate that these resins can not only tolerate formulation modulation for radiation profile-matched shielding, but they can also be printed in a variety of geometries such that mechanical properties of the printed shield are readily tuned to specific applications. In contrast, most existing shielding materials are rigid, bulky, and do not allow for the complex shapes and mechanical flexibility needed in high-usage applications. This work demonstrates the successful development of a tunable resin for additively manufactured, flexible radiation shielding material, containing high loadings of shielding filler, which can be utilized in harsh radiation environments associated with nuclear materials.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of Irradiation on Corrosion Performance of Hybrid Organic/Inorganic Coatings on Austenitic Stainless Steel

The effects of gamma radiation on the performance of two corrosion-resistant coatings applied to stainless-steel 304L (SS304L) surfaces are presented. Specifically, the ability of the coatings to mitigate corrosion of SS304L surfaces as a function of the dose received (0–1300 Mrad) and dose rate (176 compared to 1054 rad/s) is evaluated using electrochemical methods, spectroscopy, and microscopy. Coating A, an organic/inorganic hybrid coating consisting of a two-part silica ceramic component and a polymer linker was evaluated in comparison to Coating B, which utilized Coating A as a topcoat for a commercial, off-the-shelf, Zn-rich primer. Post irradiation, Coating A demonstrated some corrosion protection following exposure to low levels of gamma radiation, but coating degradation occurred with an increased exposure dose and resulted in isolated regions of corrosion initiation. For Coating B, greater corrosion resistance was observed compared to Coating A due to the sacrificial nature of the Zn at elevated doses of gamma radiation. No effect of the dose rate (for the single dose examined) was observed for either coating. It is proposed for Coating B that as the polymer coating thermally degrades above 250 °C (bond scission of the polymer occurs), the remaining Zinc layer adhered to the SS304L post-irradiation enables enhanced corrosion resistance as compared to Coating A, which displays solely polymer degradation. The results presented herein establish an understanding of coating behavior with radiation exposure, specifically the relationship between corrosion coating performance and radiation dose, and can inform ageing and lifetime management for various applications.

degradation↗

Mixed Material Scintillator Systems for Neutron Detection

Scintillators are a fundamental technology that enables radiation detection. Their use has historically enabled the detection of incoming gamma radiation, with recent advances in plastic scintillator development enabling detection and discrimination of neutron and gamma radiation through pulse shape discrimination. However, scintillators have so far consisted of a single material, typically one primary dye and one secondary dye embedded in a plastic matrix. Based on the simulation studies described previously, mixed material scintillator systems with multiple secondary dyes arranged in alternating, periodic micro-sized regions opens the door for scintillators with a wide variety of different capability, such as directional sensing, positional reconstruction, particle identification, and pulse shape discrimination. However, fabrication of a mixed material scintillator system by conventional manufacturing methods is difficult to manufacture and scale, creating a barrier to their wide spread implementation. On the other hand, additive manufacturing additive manufacturing presents itself as the optimal method for fabricating mixed material scintillator systems based on its flexibility, ability to fabricate fine features, and potential for multimaterial fabrication.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation Simulation using Wi-Fi Signal Strength and Frequency

For routine radiological operations, lost radioactive sources, decommissioning and cleanup of nuclear facilities, and radiological terrorist events such as Radioactive Dispersive Devices (RDDs) or Radiological Exposure Devices (REDs), individuals are tasked with accurately locating both point and distributed sources of radiation. Radiation workers must often practice these tasks, whether part of initial training or periodically as part of formal or informal exercises or drills. In such circumstances, it is desirable to have an accurate recreation of a radioactive source, including a method of detecting it, which does not include dangerous amounts of radiation. The goal of this research was to develop a radiation simulation technology that uses IEEE 802.11x W-LAN protocol, i.e. Wi-Fi sources and detectors for these, as an inexpensive, precise and accurate method of replicating sources of gamma radiation. For this work, existing 802.11x sources were used. Software was developed for use with an Android smartphone to detect the presence of these sources. The measurements followed the expected behavior as a function of distance from the sources, mimicking that of gamma radiation, thus demonstrating the fundamental principle of operation. The ultimate system will be used in an outreach program to interest students in the radiation protection field.

07 ISOTOPE AND RADIATION SOURCES↗

Nuclear Fuel and Pu Redox Studies from The Glenn T. Seaborg Institute at Idaho National Laboratory

The Glenn T. Seaborg Institute at Idaho National Laboratory (INL-GTSI) focuses on advancing fundamental research in the actinide sciences by providing unique opportunities to early career scientists and engineers to gain experience studying the actinide elements and their associated systems. The INL-GTSI is built from three focus areas that are based on the expertise and supporting infrastructure at INL and include solid state chemistry and physics, solution phase chemistry and physics, and forensic and isotope science. INL is the lead Laboratory for nuclear energy research and development in the U. S. and the research on nuclear fuels performed under the INL-GTSI gives good examples of solid state studies. Uranium-Molybdenum (U-Mo) alloys are leading fuel candidates for conversion of high performance research and test reactors to low-enriched fuels. During irradiation, generated fission gas accumulates into bubbles and self-organizes into a gas bubble superlattice (GBS) that effectively stores fission gases and inhibits fuel swelling. A study on the early self- organizing behavior of the GBS shows that not only grain boundaries but the interfaces between the U-Mo matrix and uranium carbide (UC) impurities are important to GBS formation.[1] In solution, understanding the complex redox behavior of plutonium in aqueous environments is critical for establishing optimized nuclear waste reprocessing solvent systems and storage tank environments. INL-GTSI researchers have produced an experimentally validated multi-scale model of the gamma radiation induced behavior of plutonium ions in concentrated aqueous HNO3 solutions.[2] Here, gamma radiation effected only minimal steady state changes in the redox distribution of the plutonium oxidation states. The redox cycling between Pu(IV) and Pu(III) is demonstrated to be mediated by the •OH/NO3• radical oxidation of Pu(III) and the H2O2/HNO3 driven reduction of Pu(IV). The INL-GTSI offers young researchers the unique chance to work directly with actinide bearing materials in a U. S. National Laboratory environment. Further topical areas of interest to the INL-GTSI include, but are not limited to, fundamental actinide properties, structure/property (electronic, magnetic, thermal) relations, actinide quantum criticality, f- electron interactions, electron correlations, computational studies, new phases, defect effects, interface interactions, isotope production and separation, forensic analytical chemistry, structure and dynamic properties of actinides in non-aqueous media, separations chemistry and kinetics for advanced nuclear fuel cycles, radiation effects, and innovative and advanced ligand design for complexation of the actinides.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of natural gamma background radiation on portal monitor radioisotope unmixing

It is well known that national security relies on several layers of protection. One of the most important is the traffic control at borders and ports that exploits Radiation Portal Monitors (RPMs) to detect and deter potential smuggling attempts. Most portal monitors rely on plastic scintillators to detect gamma rays. Despite their poor energy resolution, their cost effectiveness and the possibility of growing them in large sizes make them the gamma-ray detector of choice in RPMs. Unmixing algorithms applied to organic scintillator spectra can be used to reliably identify the bare and unshielded radionuclides that triggered an alarm, even with fewer than 1000 detected counts and in the presence of two or three nuclides at the same time. In this work, we experimentally studied the robustness of a state-of-the-art unmixing algorithm to different radiation background spectra, due to varying atmospheric conditions, in the 16 °C to 28 °C temperature range. In the presence of background, the algorithm is able to identify the nuclides present in unknown radionuclide mixtures of three nuclides, when at least 1000 counts from the sources are detected. With fewer counts available, we found larger differences of approximately 35.9% between estimated nuclide fractions and actual ones. In these low count rate regimes, the uncertainty associated by our algorithm with the identified fractions could be an additional valuable tool to determine whether the identification is reliable or a longer measurement to increase the signal-to-noise ratio is needed. Moreover, the algorithm identification performances are consistent throughout different data sets, with negligible differences in the presence of background types of different intensity and spectral shape.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

New, low-energy excitations in 107 Mo and 109 Mo

New ground-state level with spin-parity 1/2 + is established in 109 Mo, 69.8 keV below the previously reported 5/2(+) ground state in this nucleus, based on precise spectroscopy measurements of gamma radiation following spontaneous fission of 248 Cm performed using the Eurogam2 array of anti-Compton spectrometers. Analogous measurement of gamma radiation following spontaneous fission of 252 Cf, performed using the Gammasphere array, confirms the new 1/2 + ground state of 107 Mo, proposed recently and establishes the isomeric character of the 5/2 + first excited state in 107 Mo. Two beta-decaying isomers are suggested in 111 Mo nucleus based on regular energy systematics, supporting previous predictions. Low-energy excitations in Mo isotopes are interpreted and compared to calculations reported in the literature. The results suggest shape transition from prolate to oblate deformation at N >= 67.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constitutive Model of Radiation Aging Effects in Filled Silicone Elastomers under Strain

Filled silicone elastomers, an essential component in many technological applications, are often subjected to controlled or unintended radiation for a variety of reasons. Radiation exposure can lead to permanent mechanical and structural changes in the material, which is manifested as altered mechanical response, and in some cases, a permanent set. For unfilled elastomers, network theories developed and refined over decades can explain these effects in terms of chain-scission and cross-link formation and a hypothesis involving independent networks formed at different strain levels of the material. In this work, we expose a filled silicone rubber to gamma radiation while being under finite elongational strain and show that the observed mechanical and structural changes can be quantitatively modeled within the same theoretical framework developed for unfilled elastomers as long as nuances associated with the Mullins effect are accounted for in a consistent manner. In this work, we employ Ogden’s incompressible hyperelastic model within the framework of Tobolsky’s two-network scheme to describe the observed permanent set and mechanical modulus changes as a function of radiation dosage. In the process, we conclude that gamma radiation induces both direct cross-linking at chain crossings (H-links) and main-chain-scission followed by cross-linking (Y-links). We provide an estimate of the ratio of chain-scission to cross-linking rates, which is in reasonable agreement with previous experimental estimate from Charlesby–Pinner analysis. We use density functional theory (DFT)-based quantum mechanical calculations to explore the stability of –Si and –SiO radicals that form upon a radiation-induced chain-scission event, which sheds light on the relative rates of Y-linking and H-linking processes.

36 MATERIALS SCIENCE↗

Monitoring Degradation of Nuclear Cable Insulation Subjected To Sequential and Simultaneous Thermal and Radiation Aging

Predicting useful remaining life of cables in nuclear power plants is a topic of growing interest as plant continue to age. A typical electrical cable consists of polymeric materials, such as the cable jacket and insulation, which are susceptible to degradation due to exposure to both elevated temperatures and gamma irradiation over decades of service. In this work two insulation materials, crosslinked polyethylene (XLPE) and ethylene propylene diene (EPDM) elastomer, were characterized to quantify aging using total color difference and indenter modulus. Since the effects of thermal and gamma radiation are not additive but coupled, the effects of different aging scenarios including sequential and simultaneous aging were also evaluated. In the case of sequential aging, two aging scenarios were explored where the order in which thermal and gamma radiation received were altered. Total color difference of XLPE showed that sequentially aged insulation specimens, which received radiation first, degraded slightly more at maximum exposure than specimens which received thermal first. Similarly, in the case of EPDM, the extent of degradation evaluated using total color difference was found to be most severe in the case of sequentially aged insulation specimens which received radiation first. Indenter modulus was found to be insensitive to aging for XLPE but trended for EPDM. The largest variations were observed for the sequentially aged insulation specimens which received radiation first, similar to what was observed for total color difference.

Pallaka, Madhusudhan Reddy↗