Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma-ray shielding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Gamma-ray and optical observations of the 1979 November 8 solar flare

The solar flare on 1979 November 8 11h 21m 28s UT was observed by the Tel Aviv telescope of the Big Bear Solar Observatory and the High Resolution Gamma-Ray Spectrometer on the High Energy Astronomy Observatory HEAO 3. Photographs in alpha hydrogen show the development of the flare and a subsequent Moreton wave. Although the flare was not detected with the high spectral resolution germanium detectors, the HEAO C-1 CsI shield detected a statistically significant signal above 80 keV, from 420 to 585 keV, and above 3.8 MeV. The temporal structure of microwave, optical, X-ray, and gamma-ray emission is consistent to within about 1 s with a simultaneous flare response at all energies. There is no evidence for either second-stage acceleration of charged particles (Bai and Ramaty, 1979) or a delay between gamma-ray and X-ray continuum emission due to energy-dependent electron energy loss times (Bai and Ramaty).

Riegler, G. R.↗

Gamma-ray burst observations by the HEAO-3 high-resolution gamma-ray spectrometer

Special attention is given to two bursts occurring on November 16, 1979. Because of the close temporal coincidence of the two events, the possibility that both originated from a single celestial source is considered, as is the possibility that the scanning motion of HEAO-3 (nominal spin period, 20 min) was such as to exclude the first from the (approximately 30 deg FWHM) field of view of the germanium detectors and include the second. Directional data from the relative response of the shield pieces and earth occultation constraint are found to be consistent with this interpretation, and high-resolution spectral data from the second burst are discussed in this light. It is noted that recent unpublished analyses of long-baseline timing data from interplanetary spacecraft reveal that the response in the HEAO high-resolution detectors is probably earth albedo scattering. This, it is noted, can be an important systematic effect in low-earth orbit.

Wheaton, W. A.↗

Electron trapping in rad-hard RCA IC's irradiated with electrons and gamma rays

Enhanced electron trapping has been observed in n-channels of rad-hard CMOS devices due to electron and gamma-ray irradiation. Room-temperature annealing results in a positive shift in the threshold potential far beyond its initial value. The slope of the annealing curve immediately after irradiation was found to depend strongly on the gate bias applied during irradiation. Some dependence was also observed on the electron dose rate. No clear dependence on energy and shielding over a delidded device was observed. The threshold shift is probably due to electron trapping at the radiation-induced interface states and tunneling of electrons through the oxide-silicon energy barrier to fill the radiation-induced electron traps. A mathematical analysis, based on two parallel annealing kinetics, hole annealing and electron trapping, is applied to the data for various electron dose rates.

Danchenko, V.↗

A high energy resolution experiment in the hard X-ray range

The Low Energy Gamma-Ray Spectrometer (LEGS), a joint project among NASA/GSFC, CEN-SACLAY, and Rice University, is designed to perform fine energy resolution measurements of astrophysical sources. In its low energy configuration (20-800 keV energy range) the instrument uses three planar detectors (effective area of 53 sq cm) surrounded by a combination of passive Fe and active NaI for shielding and collimation (FOW of about 5 x 10 deg FWHM). In a typical one-day balloon flight, LEGS sensitivity limit (3 sigma) for narrow line features is not greater than about 0.0003 ph/sq cm s (at 100 kev).

Paciesas, W.↗

HEAO 3 measurements of the atmospheric positron annihilation line

The atmospheric positron annihilation line at 511 keV was the first gamma-ray line observed which originates from processes of astrophysical importance. Measurements of the properties of a positron annihilation line make it possible to determine many of the physical conditions present at the source of emission. An investigation was conducted of the 511-keV line measured with the HEAO C-1 experiment. The HEAO C-1 experiment consisted of a cluster of four, large, high-purity germanium detectors surrounded by an active anticoincidence CsI shield. A strong atmospheric line was measured at 511.07 + or - 0.10 keV. The net atmospheric emission has been accurately determined as a function of geomagnetic latitude and varies from 0.01 photons/sq cm-sec-sr near the magnetic equator to 0.035 photons/sq cm-sec-sr at a latitude of 55 deg.

Mahoney, W. A.↗

High sensitivity high resolution double scatter 1-30 MeV gamma ray telescope

The design and performance of the double-scatter 1-30-MeV gamma-ray telescope developed at the University of California for balloon-borne observations are reported and illustrated with drawings, diagrams, and graphs. The telescope comprises an upper array of 16 6.03 x 6.03 x 100-cm plastic scintillator bars viewed by photomultiplier tubes (PMTs) at both ends, a lower array (at 100-cm distance) of 16 4.83 x 4.83 x 100-cm NaI(Tl) bars viewed at both ends by PMTs, and four 122 x 122 x 0.64-cm plastic sheets viewed by four PMTs each as charged-particle anticoincidence shielding. The operating principle of the telescope, the tests conducted on the NaI(Tl) bars, the on-board data-processing electronics, and the overall performance are characterized. Performance parameters include area 1 sq m, field of view pi sr, 4-sigma sensitivity above 1 MeV 0.00004 gamma/sq cm sec over 25 h, angular resolution about 3.5 deg FWHM, and energy resolution 10 percent at 1 MeV and 6 percent at 6 MeV.

Zych, A. D.↗

Cosmogeneic radionuclides in the Havero meteorite.

An 87-gram sample of the Havero ureilite has been analyzed by nondestructive gamma-ray spectrometry. The results of the measurements, in dpm/kg at time of fall, are: Na-22, 71 plus or minus 3; Al-26, 43 plus or minus 3; Sc-46, 3.4 plus or minus 2.1; Mn-54, 35 plus or minus 6; Co-60, less than or equal to 0.7, 2 sigma limit. Havero has 77 plus or minus 14% of the Al-26 activity calculated for its chemical composition. When averaged with previously reported analyses of Goalpara and Novo Urei, ureilites as a class have 74 plus or minus 7% of their expected Al-26 activity. The depletion in Al-26 could be the coincidental result of identical 'shielding' effects in three meteorites of apparently very different preatmospheric sizes. Alternatively, ureilites may have been exposed to a lower cosmic-ray flux than that experienced by most chondrites, probably the result of characteristically different orbits.

Cressy, P. J., Jr.↗

A study of the sensitivity of an imaging telescope (GRITS) for high energy gamma-ray astronomy

When a gamma-ray telescope is placed in Earth orbit, it is bombarded by a flux of cosmic protons much greater than the flux of interesting gammas. These protons can interact in the telescope's thermal shielding to produce detectable gamma rays, most of which are vetoed. Since the proton flux is so high, the unvetoed gamma rays constitute a significant background relative to some weak sources. This background increases the observing time required to pinpoint some sources and entirely obscures other sources. Although recent telescopes have been designed to minimize this background, its strength and spectral characteristics were not previously calculated in detail. Monte Carlo calculations are presented which characterize the strength, spectrum and other features of the cosmic proton background using FLUKA, a hadronic cascade program. Several gamma-ray telescopes, including SAS-2, EGRET and the Gamma Ray Imaging Telescope System (GRITS), are analyzed, and their proton-induced backgrounds are characterized. In all cases, the backgrounds are either shown to be low relative to interesting signals or suggestions are made which would reduce the background sufficiently to leave the telescope unimpaired. In addition, several limiting cases are examined for comparison to previous estimates and calibration measurements.

Yearian, Mason R.↗

The design of a source to simulate the gamma-ray spectrum emitted by a radioisotope thermoelectric generator

A simulated source was designed to duplicate the gamma spectrum of a uniform cylindrical 2200-watt Pu02 radioisotope thermoelectric generator containing 81% Pu-238 and 1.2 ppm Pu-236. Gamma rays from the decay of Pu-238, Am-241, Pu-239, and the 0-18(alpha,n)Ne-21 reaction were catalogued in broad energy groups. Two 46- and one 22-mc Th-228 sources provided simulation at various times in the life of the fuel capsule up to 18 years, which covers the time span of an outer planet mission. Emission from Th-228 represents the overwhelming contribution of the gamma spectrum after the first few years. The sources, in the form of 13-inch rods, were placed in a concentric hole in a cylinder of depleted uranium, which provided shielding equivalent to the self-shielding of the fuel capsule. The thickness of the U-238 cylinder (0.55cm) was determined by Monte Carlo calculations to insure that the spectrum emerging from the simulated source matched that of the fuel capsule.

Reier, M.↗

Nuclear radiation analysis

A study program of radiation shielding against the deleterious effects of nuclear radiation on man and equipment is reported. The methods used to analyze the radiation environment from bremsstrahlung photons are discussed along with the methods employed by transport code users. The theory and numerical methods used to solve transport of neutrons and gammas are described, and the neutron and cosmic fluxes that would be present on the gamma-ray telescope were analyzed.

Knies, R. J.↗

A directional low energy gamma-ray detector

The sensitivity of a directional gamma ray detector, which relies on blocking a source to determine its direction and energy spectrum, is calculated and compared to the more conventional well-shaped shielded detectors. It is shown that such an anticollimator detection system provides a basis for measuring the celestial diffuse gamma ray background, gamma ray sources and bursts with good energy, angular, and time resolution, and that additionally the system is 20 to 50 times as sensitive as conventional detectors when compared on a per unit mass basis.

Morfill, G.↗

A directional low energy gamma-ray detector

The sensitivity of a directional gamma ray detector, which relies on blocking a source to determine its direction and energy spectrum, is calculated and compared to the more conventional well shaped shielded detectors. It is shown that such an anticollimator detection system provides a basis for measuring the celestial diffuse gamma ray background, gamma ray sources and bursts with good energy, angular, and time resolution, and that additionally the system is 20 to 50 times as sensitive as conventional detectors when compared on a per unit mass basis.

Morfill, G.↗

A balloon-borne Ge/Li/ spectrometer for gamma-ray astronomy

On June 10, 1974, a new high-resolution gamma ray spectrometer operating in the energy range of 0.05 to 10 MeV was successfully balloon-flight tested. This system uses four 40 cu cm Ge(Li) crystals in a single cryostat as prime sensors. A 6.35 cm thick CsI (Na) shield provides background rejection and collimation, defining a solid angle of 0.095 sr. Cooling is provided by a liquid-nitrogen dewar. The system was highly stable with spectral resolution of better than 2.5 keV at 1 MeV for the flight duration. The background total count rate was about 20 counts/sec. Numerous lines were observed, most of which originated from secondary neutron interactions in the spectrometer. The sensitivity of the system to line emissions originating in cosmic point sources is 0.0001 to 0.001 photons per sq cm s over the energy range.

Jacobson, A. S.↗

The HEAO-3 high resolution gamma-ray spectrometer

Features and results produced by the HEAO 3 spacecraft gamma ray spectrometer are outlined. The instrument had high resolution germanium detectors, each 55 mm diam and 45 mm long, surrounded by a cesium iodide anticoincidence shield with four quadrants of well-crystal and a collimayor crystal. The crystals had a total effective area of 70 sq cm at 100 keV and 26.4 sq cm at .511 MeV with a spectral resolution at launch of .23 percent at 1.33 MeV. The spacecraft travels a circular orbit of 500 km altitude with an inclination of 43.6 deg. Solid methane and ammonia cryogenic fluids refrigerated the crystals for 8.5 mos, after which the shield crystals functioned as isotropic detectors for solar flare events and gamma ray bursts until mission termination in May 1981. A total of 37 solar flare type events were observed, with gamma ray events occurring with flares of class X1 or stronger.

Jacobson, A. S.↗

Gamma-ray burst variability above 4 MeV

The relationship between the hard X-ray and gamma ray emissions during four bursts using the anti-coincidence shields of the High Energy Astronomy Observatory 3 (HEAO 3) Gamma Ray Spectrometer is explored. Recent observations of gamma ray bursts by the Solar Maximum Mission Gamma Ray Spectrometer (GRS) have shown that high energy emission above 1 MeV is a common and energetically important feature (Matz et al. 1985). Time histories of four gamma ray bursts in 3 energy bands ( keV, around 511 keV, and 4 MeV) with 10.24 a resolution show that the 4 MeV flux is only weakly coupled to the spectrum below approximately 600 keV.

Schwartz, R. A.↗

A high-resolution gamma-ray and hard X-ray spectrometer for solar flare observations in Max 1991

A long duration balloon flight instrument for Max 1991 designed to study the acceleration of greater than 10 MeV ions and greater than 15 keV electrons in solar flares through high resolution spectroscopy of the gamma ray lines and hard X-ray and gamma ray continuum is described. The instrument, HIREGS, consists of an array of high-purity, n-type coaxial germanium detectors (HPGe) cooled to less than 90 K and surrounded by a bismuth germanate (BGO) anticoincidence shield. It will cover the energy range 15 keV to 20 MeV with keV spectral resolution, sufficient for accurate measurement of all parameters of the expected gamma ray lines with the exception of the neutron capture deuterium line. Electrical segmentation of the HPGe detector into a thin front segment and a thick rear segment, together with pulse-shape discrimination, provides optimal dynamic range and signal-to-background characteristics for flare measurements. Neutrons and gamma rays up to approximately 0.1 to 1 GeV can be detected and identified with the combination of the HPGe detectors and rear BGO shield. The HIREGS is planned for long duration balloon flights (LDBF) for solar flare studies during Max 1991. The two exploratory LDBFs carried out at mid-latitudes in 1987 to 1988 are described, and the LDBFs in Antarctica, which could in principle provide 24 hour/day solar coverage and very long flight durations (20 to 30 days) because of minimal ballast requirements are discussed.

Lin, R. P.↗

The GRAD high-altitude balloon flight over Antarctica

The Gamma Ray Advanced Detector (GRAD) consists of a n-type germanium detector inside an active bismuth-germanate Compton and charged particle shield with additional active plastic shielding across the aperture. It will be flown on a high-altitude balloon at 36 km altitude at a latitude of 78 deg S over Antarctica for observations of gamma radiation emitted by the radioactive decay of Co-56 in the supernova SN1987A, for assessment of the performance of bismuth-germanate scintillation material in the radiation environment of near space, for gathering information on the gamma-ray background over Antarctica, and for testing fault-tolerant software.

Eichhorn, G.↗