Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas network operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Deployment of Dynamic Neural Network Optimization to Minimize Heat Rate During Ramping for Coal Power Plants (Final Technical Report)

Much success was achieved throughout the course of this project. A successful implementation of Dynamic Neural Network Optimization (D-NNO) was coupled with Adaptive Predictive Controls (APC) and a novel hardware installation comprised of an advanced sensor network (ASN) measuring mass-weighted averages of flue gas constituents above the horizontal superheater of a coal-fired utility boiler. From 2019 through 2023 (including an extension due to COVID delays), the team was able to prototype, evaluate, deploy, iterate, and ultimately finalize an advanced closed-loop control D-NNO system which demonstrated the ability to: •improve unit efficiency ~2.0% relative to unoptimized operation (represented as total fuel fired per MWh generated) •improve unit NOx emission rates 10%+ beyond static optimization baselines •improve unit temperature stability as much as 58% and on average 12% •improve operating load stability as much as 35% The culmination of this project has generated an advanced methodology of deploying specially designed recurrent neural networks (long short-term memory, gated recurrent unit, encoder-decoder networks, transformers, etc.), customized trajectory planning and closed-loop optimization modules capable of adapting to live electric grid responses and demands, self-tuning and adaptive expert controls constantly adjusting prediction parameters to real-time unit behavior, and a hardware/software package able to reliably calculate net unit heat rate (NUHR) in real-time using flue gas constituents, machine learning, and known combustion relationships. Through this real-time NUHR value, immediate feedback on system adjustments relative to operating efficiency was available, allowing for rapid improvements to system performance. In addition to development and deployment of the advanced D-NNO system, the approach methodology has been readily commercialized through the project platform Griffin Open Systems, LLC, the D-NNO software platform host. Similar methodologies to those developed by this project have already been deployed at 5 other units across the United States, with another 6 implementations scheduled, and more expected. Over the course of the project, multiple academic papers were submitted and accepted for publication within esteemed academic journals, and PhD students were trained and graduated, as well as undergraduate students becoming involved and participating to project objectives.

01 COAL, LIGNITE, AND PEAT↗

The Use of Machine Learning Models for Predicting the Dielectric Strength of Gases

Technological advancements in high voltage systems have pushed sulfur hexafluoride (SF6) to its operational limits. Furthermore, this gas has other drawbacks including a high liquefaction temperature and a high global warming potential. Therefore, there has been an urgent need to find alternative gases with high dielectric strength (DS). In this work, density functional theory (DFT) is used to calculate molecular descriptors that are fed into an artificial neural network (ANN) and a random forest (RF). These machine learning (ML) models are then used to predict the DS for hundreds of molecules. A finite element model (FEM) is also used to calculate the electric field profile of multiple simple electrode geometries as the applied voltage to the system is increased. Results indicate that the random forest model has better generalization to unseen data than the neural network. The highest DS value predicted by the RF was 2.16 relative to the experimental DS of SF6. The results also demonstrate how choosing a gas with a higher DS and a geometry with minimal edges and corners can significantly increase the operating voltage of an electrical system. Due to its superior generalization, the RF represents the most promising path toward an accurate DS predictor once sufficient experimental data are available.

Mileski, Matthew [AFIT]↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

Resilience assessment and planning in power distribution systems: Past and future considerations

High impact low probability (HILP) events such as hurricanes, heat waves, and floods have instigated widespread power outages and blackouts around the globe in the past decade. With the increasing challenges concerning the threats to the power distribution systems and the growing need to mitigate the impacts of the HILP events, resilience has become a crucial requirement for the power grid infrastructures. Numerous efforts have been made to define, measure, and characterize the resilience of power distribution systems. This study thoroughly reviews the state-of-the-art methods on the existing resilience evaluation framework and metrics. Here, the desirable characteristics of resilience metrics are highlighted, and the challenges associated with formulating, developing, and calculating such metrics are discussed. Next, we detail the state-of-the-art literature on planning solutions to ensure distribution system resilience. This paper aims to extract a deep insight into this challenging and critical research area and envision future opportunities that can guide the power distribution system operators/planners to formulate more effective mitigation strategies to enhance the resilience of power distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Natural Gas Vehicle Basics

Natural gas powers about 175,000 U.S. vehicles and more than 23 million vehicles worldwide [1]. Natural gas vehicles (NGVs) are a good choice for high-mileage (high fuel-use) fleets - such as buses, medium- and heavy-duty trucks, and refuse vehicles - that are centrally fueled or operate within a limited area or along a route with natural gas fueling stations. The advantages of natural gas as an alternative fuel include its domestic production, established distribution network, relatively low cost, and emissions benefits.

30 DIRECT ENERGY CONVERSION↗

Natural Gas Vehicle Basics

Natural gas powers about 175,000 U.S. vehicles and more than 23 million vehicles worldwide.1 Natural gas vehicles (NGVs) are a good choice for high-mileage (high fuel-use) fleets - such as buses, medium- and heavy-duty trucks, and refuse vehicles - that are centrally fueled or operate within a limited area or along a route with natural gas fueling stations. The advantages of natural gas as an alternative fuel include its domestic production, established distribution network, relatively low cost, and emissions benefits.

alternative fuel↗

Techno-Economic Analysis of Repurposing Natural Gas Transmission Pipeline Networks to Accommodate Hydrogen Blends

Blending hydrogen into natural gas infrastructure could supplement natural gas supply and increase resilience for applications such as ammonia production, peaking and load-following power plants, and heating. The United States has an extensive network of natural gas pipelines, but the feasibility of employing this infrastructure to transport hydrogen is unclear. We analyze the costs associated with repurposing three distinct natural gas transmission pipelines in different locations within the United States to carry blends of hydrogen up to 100% via three different pipeline network modification methods and compare against the cost of building a new dedicated hydrogen pipeline. We conduct a sensitivity analysis on the hoop stress limit of the existing pipe, techno-economic parameters, emissions, and relative capacity. The results show that the capital costs required to upgrade a pipeline can vary from tens of millions to billions of dollars depending on the length and capacity of the existing pipeline section, whether the existing pipeline already operates at or below its maximum allowable operating pressure, whether future demand is expected to increase or decrease, the network modification method selected, and pipe material costs. The delivered cost of energy to end users is impacted less by the levelized cost of transporting hydrogen blends than by the cost of the natural gas and hydrogen fuels being transported. The emissions impact of blending hydrogen into natural gas transmission networks scales proportionally with the amount of energy displaced with low-emission hydrogen (such as from natural gas with carbon capture and sequestration or electrolysis powered by nuclear, renewable, or geothermal electricity), therefore low blend ratios (e.g., < 20% vol. hydrogen) will result in low emissions impacts. Factors such as permitting and right-of-way costs, the proximity of the pipeline to hydrogen demand and production, and the compatibility of and/or retrofitting costs of end-use gas-fueled technologies will likely be greater drivers in determining whether converting a particular natural gas pipeline to carry hydrogen makes economic sense.

08 HYDROGEN↗

Optimizing the design and operation of water networks: Two decomposition approaches

We consider the design and operation of water networks simultaneously. Water network problems can be divided into two categories: the design problem and the operation problem. The design problem involves determining the appropriate pipe sizing and placements of pump stations, while the operation problem involves scheduling pump stations over multiple time periods to account for changes in supply and demand. Our focus is on networks that involve water co-produced with oil and gas. While solving the optimization formulation for such networks, we found that obtaining a primal (feasible) solution is more challenging than obtaining dual bounds using off-the-shelf mixed-integer nonlinear programming solvers. Therefore, we propose two methods to obtain good primal solutions. One method involves a decomposition framework that utilizes a convex reformulation, while the other is based on time decomposition. To test our proposed methods, we conduct computational experiments on a network derived from the PARETO case study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-Field Testing of Components for Feedback and Control of the ITER Disruption Mitigation System

Here, the shattered pellet injection (SPI) method has been chosen as the disruption mitigation system (DMS) for ITER. To protect the device from plasma disruptions that cause damaging heat and electromagnetic loads, SPI is used to inject high-Z material into the plasma. The process of SPI utilizes cryogenic cooling to form solid pellets. Pellets are accelerated down a barrel and into an angled surface, causing the pellet to shatter prior to entering the tokamak chamber. For the DMS to function reliably, the 27 separate shattered pellet injectors planned for ITER must rely on many components to provide accurate feedback data and for control functions. Each component in the DMS is exposed to an elevated background magnetic field depending on its placement and proximity to the plasma chamber. A Helmholtz coil test stand that is operated at Oak Ridge National Laboratory was utilized to test the components in relevant background field levels to assess component performance. This paper details the test design and results for in-field component operation for a variety of components. This list includes the following components: two different network switches for camera connectivity, a VAT fast shutter valve intended to reduce the flow of SPI propellant gas into the torus, a solenoid control valve intended for use in the pellet formation process, pressure/vacuum switches to be used for feedback and control, a printed circuit board piezo pressure sensor to be used to measure breech pressure, and various relays for the high-voltage pulsed power supply used to drive the SPI propellant valve.

Disruption mitigation↗

Defining Detection Limits for Continuous Monitoring Systems for Methane Emissions at Oil and Gas Facilities

Networks of fixed-point continuous monitoring systems are becoming widely used in the detection and quantification of methane emissions from oil and gas facilities in the United States. Regulatory agencies and operators are developing performance metrics for these systems, such as minimum detection limits. Performance characteristics, such as minimum detection limits, would ideally be expressed in emission rate units; however, performance parameters such as detection limits for a continuous monitoring system (CMS) will depend on meteorological conditions, the characteristics of emissions at the site where the CMS is deployed, the positioning of CMS devices in relation to the emission sources, and the amount of time allowed for the CMS to detect an emission source. This means that certifying the performance of a CMS will require test protocols with well-defined emission rates and durations; initial protocols are now being used in field tests. Field testing results will vary, however, depending on meteorological conditions and the time allowed for detection. This work demonstrates methods for evaluating CMS performance characteristics using dispersion modeling and defines an approach for normalizing test results to standard meteorological conditions using dispersion modeling.

Chen, Qining (ORCID:0000000316908091)↗

Regulating Gas Transport in Molecularly Engineered Polymer Membranes (Final Technical Report)

Energy-efficient separation processes are essential for a wide range of applications ranging from clean fuels (e.g., hydrogen purification) and petroleum refining (e.g., natural gas processing) to water purification and carbon capture. Membrane-mediated separations have shown tremendous promise in providing high productivity and high separation efficiency at significantly lower energy consumption, e.g., up to 90% less energy cost than traditional thermally driven processes such as distillation. Polymeric membranes–the dominant separation membrane materials–have yet to reach their full potential due to their limitations in long-term durability (e.g., productivity loss over the period of their lifetime due to physical aging) or insufficient stability under harsh conditions (e.g., high temperature, chemically complex feeds). This research seeks to establish a new paradigm in polymer membrane material design by harnessing crosslinked model networks with well-defined yet finely tailorable microstructure to facilitate fast and selective gas transport and simultaneously enhance membrane stability. Unlike traditional randomly crosslinked polymers, which suffer from structural inconsistencies and consequently suboptimal gas separation performance, crosslinked model network membranes prepared via a precisely controlled end-linking process enables the creation of previously unattainable microstructure tunability, which, in turn, results in versatile crosslinked membranes with high separation performance that meet the needs of various challenging gas separations. Using model network framework as a fundamental tool by applying this concept in diverse polymer categories, this work has led to the development of various innovative crosslinked membrane structures such as unimodal, bimodal and clustered model networks. These advanced crosslinked polymer membranes not only demonstrate exceptional gas separation performance that significantly outperform existing randomly crosslinked membranes, but also possess excellent long-term durability and robust stability under complex operating conditions. From a fundamental perspective, results from this research provide critical mechanistic insights into gas separation in crosslinked polymer membranes, addressing key knowledge gaps and opening new avenues for membrane design to meet various separation needs. The new membrane materials produced from this research enable the use of polymeric membranes for high temperature gas separations, offering substantial energy and cost savings by eliminating the need for repeated cooling-heating cycles in industrial processes.

02 PETROLEUM↗

Integrating the Design of Desalination Technologies into Produced Water Network Optimization

The oil and gas energy sector uses billions of gallons of water for hydraulic fracturing each year to extract oil and gas. The water injected into the ground for fracturing along with naturally occurring formation water from oil wells surfaces back in the form of produced water. Produced water can contain high concentrations of total dissolved solids and is unfit for reuse outside the oil and gas industry without desalination. In semi-arid shale plays, produced water desalination for beneficial reuse could play a crucial role in alleviating water shortages and addressing extreme drought conditions. In this poster we co-optimize the design and operation of desalination technologies along with operational decisions across produced water networks. A multi-period produced water network model with simplified split-fraction-based desalination nodes is developed. Rigorous steady-state desalination mathematical models based on mechanical vapor recompression are developed and embedded at the desalination sites in the network model. An optimal common design across all periods is ensured using global capacity constraints. The solution approach is demonstrated for multi-period planning problems on networks from the PARETO open-source library. Model formulation and challenges associated with scalability are discussed.

Naik, Sakshi↗

Integrating the Design of Desalination Technologies into Produced Water Network Optimization

The oil and gas energy sector uses billions of gallons of water for hydraulic fracturing each year to extract oil and gas. The water injected into the ground for fracturing along with naturally occur-ring formation water from the oil wells surfaces back in the form of produced water. Produced water can contain high concentrations of total dissolved solids and is unfit for reuse outside the oil and gas industry without desalination. In semi-arid shale plays, produced water desalination for beneficial reuse could play a crucial role in alleviating water shortages and addressing extreme drought conditions. In this paper we co-optimize the design and operation of desalination technologies along with operational decisions across produced water networks. A multi-period produced water network model with simplified split-fraction-based desalination nodes is developed. Rigorous steady-state desalination mathematical models based on mechanical vapor recompression are developed and embedded at the desalination sites in the network model. An optimal common design is ensured across all periods using global capacity constraints. The solution approach is demonstrated for multi-period planning problems on networks from the PARETO open-source library. Model formulation and challenges associated with scalability are discussed.

Naik, Sakshi↗

Oscillatory Spreading and Inertia in Power Grids

The increase in variable renewable generators (VRGs) in power systems has altered the dynamics from a historical experience. VRGs introduce new sources of power oscillations, and the stabilizing response provided by synchronous generators (SGs, e.g., natural gas, coal, etc.), which help avoid some power fluctuations, will lessen as VRGs replace SGs. These changes have led to the need for new methods and metrics to quickly assess the likely oscillatory behavior for a particular network without performing computationally expensive simulations. This work studies the impact of a critical dynamical parameter - the inertia value - on the rest of a power system's oscillatory response to representative VRG perturbations. We use a known localization metric in a novel way to quantify the number of nodes responding to a perturbation and the magnitude of those responses. This metric allows us to relate the spread and severity of a system's power oscillations with inertia. We find that as inertia increases, the system response to node perturbations transitions from localized (only a few close nodes respond) to delocalized (many nodes across the network respond). We introduce a heuristic computed from the network Laplacian to relate this oscillatory transition to the network structure. We show that our heuristic accurately describes the spread of oscillations for a realistic power-system test case. Using a heuristic to determine the likely oscillatory behavior of a system given a set of parameters has wide applicability in power systems, and it could decrease the computational workload of planning and operation.

dynamical systems↗

Development and Commercialization of Heavy-Duty Battery Electric Trucks Under Diverse Climate Conditions (DTNA EMG Innovation eCascadia 2.0 Final Technical Report)

During this project DTNA advanced heavy-duty transportation technologies to produce the eCascadia 2.0, a fully commercialized Class 7/8 electric tractor with the range and durability to meet the needs of 70% of freight movement in the United States. The eCascadia2.0 provides flexibility, operational performance, efficiency, and maintenance cost savings to the end user. The most direct outcome of this project is a commercially viable zero-emission heavy duty option with a 250-mile daily range and sufficient payload for regional haul duty cycles. The larger outcome is an acceleration of the market transformation away from petroleum-based fuels. DTNA’s comprehensive sales team, dealer network, customer network and maintenance and support teams will ensure that this is not a standalone zero-emission truck, but rather one that can be produced, marketed, and operated at scale to realize vast greenhouse gas and criteria pollutant emissions reductions, while also bringing zero emission vehicles closer to cost parity.

33 ADVANCED PROPULSION SYSTEMS↗

Network Optimization of the Electrosynthesis of Chemicals from CO2

Carbon dioxide electroreduction (ECO2R) is gaining attention due to its capacity to mitigate CO2 emissions while using electricity that would otherwise be curtailed. Its foreseeable industrial implementation requires of holistic methods to assess the technological and economic performance of ECO2R processes and integrate them in current chemical supply chains and power systems. Here, we combine techno-economic assessment and mathematical programming to find the optimal paths to electroreduce CO2 into valuable chemicals under variable electricity prices. The proposed approach is tested with a case study addressing the CO2 capture from flue gas or direct air and its electricity-powered reduction into carbon monoxide, formic acid or multi-carbon compounds. The results obtained demonstrate the ability of the framework to build ECO2R networks and provide operation profiles that respond to fluctuating electricity prices.

carbon dioxide↗

Grid-Integrated Production of Fischer-Tropsch Synfuels from Nuclear Power

Idaho National Laboratory (INL) investigates the relative economic profitability of an integrated energy system (IES) coupling an NPP with a synfuel production process at selected case study locations across the United States. In the synfuel IES, a high-temperature steam electrolysis (HTSE) plant is thermally and electrically coupled with an NPP to produce zero-carbon hydrogen. The synthetic fuel is produced from this H 2 combined with a CO 2 supply using the reverse water gas shift process followed by the Fischer-Tropsch (FT) reaction. This analysis considers a system in which the CO 2 is sourced from regional CO 2 emitters via the construction and operation of pipeline-based CO 2 supply networks. Locating the FT plant at the same site as the NPP and HTSE plants enables the NPP to provide zero-carbon heat and power to the HTSE plant and zero-carbon power to the FT plant as well as avoid the requirement for long-distance H 2 product transport from the HTSE plant to the FT plant. Hydrogen storage is used to enable the NPP to dispatch power to the electrical grid (instead of the HTSE plant) when grid demand increases, thus enabling the FT plant to continue to operate in a steady-state production mode. The ability to cease hydrogen production for several hours within each day enables the NPP to provide power to the grid to balance the electricity market during peak periods and maximize revenues for the nuclear synfuel IES. The FT process design considered has a 99% carbon conversion efficiency. The use of nuclear energy and nuclear energy-derived hydrogen enables synfuel production to achieve this high level of carbon utilization. Additionally, the life-cycle carbon emissions of the nuclear-based synfuel production process are very low, with WTW emissions of approximately 25 gCO 2 e/MJ, including steam credits (generated from FT process excess heat), and approximately 7 gCO 2 e/MJ, if steam credits are excluded. This compares favorably with the WTW emissions of 90.5 gCO 2 e/MJ for a compression-ignition, direct injection (CIDI) vehicle with a fuel economy of 31.6 miles per gallon gasoline equivalent (MPGGE), using low-sulfur diesel produced using conventional petroleum production and refining processes. Several NPPs in various regions of the U.S. are considered as case study analyses. Supply locations and transportation via pipeline of the CO 2 feedstock to the NPP site are analyzed through the National Energy Technology Laboratory (NETL) CO 2 Transport Cost model. The team finds that the amount of CO 2 generated by different sectors is sufficient for the synfuel production process at all locations considered. The CO 2 transportation costs are functions of the distance of the source to the NPP location, the CO 2 capture cost at the source, and the quantity of CO 2 transported. Historical electricity prices for the NPP case study locations are collected and analyzed. Monthly average prices, price range, and duration of negative-price periods vary among these locations. For each location, an auto-regressive moving average (ARMA) model is trained on historical electricity price data. ARMA validation is done to ensure the synthetic price distributions represent one of historical prices with high fidelity. Synthetic time series from these ARMA models are used in a coupled dispatch and system optimization in the Holistic Energy Resource Optimization Network (HERON) to compute the differential net present value (NPV) of the IES. The team finds that this econometric is positive, ranging from $14M–1.3bn (2020) depending on the location. The optimal synfuel IES configuration to obtain this increase in NPV often maximizes the size of the synfuel production process with regards to the size of the NPP. However, the team shows that the NPP still plays a stabilizing role for the grid: In periods of high prices and high loads, more electricity from the NPP is sent to the grid. A high variability of electricity prices and extreme maximum prices tend to drive up electricity production. While it requires significant investment, the synfuel IES could increase the economic profitability for the existing fleet of LWRs across the country while still maintaining the grid stabilizer role of NPPs. During its lifetime, the main costs for the nuclear synfuel IES are the carbon feedstock transportation costs, followed by the capital expenses (CAPEX) and operation and maintenance (O&M) costs while the revenue comes first from the IRA H 2 production tax credit (PTC) and then from the sales of synfuel products. The profitability of the synfuel IES is most sensitive to the value of the hydrogen PTC and the synfuel products as well as the cost of the carbon feedstock, highlighting the importance of governmental incentives regarding hydrogen, carbon emissions, and synfuel in driving the deployment of future nuclear synfuel IESs.

08 HYDROGEN↗