Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gate selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Oxygen and germanium migration at low temperature influenced by the thermodynamic nature of the materials used in germanium metal-insulator-semiconductor structures

The influence of the reductive character of the metals used for the gate electrode on O migration in gate stacks and following reductive or oxidative reactions at an interface between a high permittivity (high-k) insulating layer and Ge or Si was investigated. The magnitude of the increase or decrease of Ge or Si oxides in the gate stacks caused by the metal layer deposition can be systematically correlated with the oxygen chemical potential (μ{sub O}) of gate metals for both Ge and Si systems. However, the influence of the gate metals on oxidative/reductive reactions of a semiconductor element is more significant for the Ge gate stacks than the Si system. Detailed investigations of Ge oxide as a function of depth were used to determine that the strong μ{sub O} dependence of the increase or decrease in the Ge oxide is because of the high diffusivity of Ge into the high-k oxide. In particular, migration of Ge into the high-k oxide occurs concurrently with O migration towards the reductive metal layer, and the strong reductive character of the metal significantly influences the decrease in the amount of Ge oxide. These results indicate the importance of the selection of gate metals based on μ{sub O} for controlling high-k/Ge interfacial structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of a breathing surrogate prediction algorithm for prospective pulmonary gating

Purpose: A major challenge of four dimensional computed tomography (4DCT) in treatment planning and delivery has been the lack of respiration amplitude and phase reproducibility during image acquisition. The implementation of a prospective gating algorithm would ensure that images would be acquired only during user-specified breathing phases. This study describes the development and testing of an autoregressive moving average (ARMA) model for human respiratory phase prediction under quiet respiration conditions. Methods: A total of 47 4DCT patient datasets and synchronized respiration records was utilized in this study. Three datasets were used in model development and were removed from further evaluation of the ARMA model. The remaining 44 patient datasets were evaluated with the ARMA model for prediction time steps from 50 to 1000 ms in increments of 50 and 100 ms. Thirty-five of these datasets were further used to provide a comparison between the proposed ARMA model and a commercial algorithm with a prediction time step of 240 ms. Results: The optimal number of parameters for the ARMA model was based on three datasets reserved for model development. Prediction error was found to increase as the prediction time step increased. The minimum prediction time step required for prospective gating was selected to be half of the gantry rotation period. The maximum prediction time step with a conservative 95% confidence criterion was found to be 0.3 s. The ARMA model predicted peak inhalation and peak exhalation phases significantly better than the commercial algorithm. Furthermore, the commercial algorithm had numerous instances of missed breath cycles and falsely predicted breath cycles, while the proposed model did not have these errors. Conclusions: An ARMA model has been successfully applied to predict human respiratory phase occurrence. For a typical CT scanner gantry rotation period of 0.4 s (0.2 s prediction time step), the absolute error was relatively small, 0.06{+-}0.02 s at peak inhalation and 0.05{+-}0.04 s at peak exhalation. The application of the ARMA model for prospective pulmonary gating has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conformational plasticity in the selectivity filter of the TRPV2 ion channel

Transient receptor potential vanilloid (TRPV) channels are activated by ligands and heat and are involved in various physiological processes. In contrast to the architecturally related voltage-gated cation channels, TRPV1 and TRPV2 subtypes possess another activation gate at the selectivity filter that can open widely enough to permeate large organic cations. Despite recent structural advances, the mechanism of selectivity filter gating and permeation for both metal ions and large molecules by TRPV1 or TRPV2 is not well known. Here, we determined two crystal structures of rabbit TRPV2 in its Ca 2+ -bound and resiniferatoxin (RTx)- and Ca 2+ -bound forms, to 3.9 Å and 3.1 Å, respectively. Notably, our structures show that RTx binding leads to two-fold symmetric opening of the selectivity filter of TRPV2 that is wide enough for large organic cation permeation. Furthermore,combined with functional characterizations, our studies reveal a structural basis for permeation of Ca 2+ and large organic cations in TRPV2.

59 BASIC BIOLOGICAL SCIENCES↗

2π1ν states populated in 135Te from 9Be-induced reactions with a 132Sn beam

γ-ray transitions in 134Te, 135Te, and 136Te were measured from 9Be-induced reactions with a radioactive 132Sn beam at a sub-Coulomb barrier energy of 3 MeV per nucleon using particle-γ coincidence spectroscopy. The transitions were selected by gating on alpha-like particles in a CsI detector following a combination of (9Be,α1n), (9Be,α2n), and (9Be,α3n) incomplete fusion-evaporation reactions. Distorted-wave Born approximation calculations suggest little to no contribution from the (9Be,7He), (9Be,6He), and (9Be,5He) direct reactions.γ-ray transitions from previously known 2+Ⓧν2f7/2 and 4+Ⓧν2f7/2 multiplet members in 135Te are observed. A new γ ray is observed, assigned to the third-excited state in 135Te, and new 2+Ⓧν2f7/2 multiplet members are suggested. In addition, spin assignments are made by using recent one-neutron transfer data. The updated experimental data for 135Te are compared to shell-model calculations for a relatively complete set of states up to the yrast 15/2-,4+Ⓧν2f7/2 multiplet member at 1505 keV.

Allmond, James M.↗

Majorana pair based qubits for fault tolerant quantum computing architecture using superconducting gold surface states

Under certain conditions, a fermion in a superconductor can separate in space into two parts known as Majorana zero modes, which are immune to decoherence from local noise sources and are attractive building blocks for quantum computers. Here we disclose a metal-based heterostructure platform to produce these Majorana zero modes which utilizes the surface states of certain metals in combination with a ferromagnetic insulator and a superconductor. This platform has the advantage of having a robust energy scale and the possibility of realizing complex circuit designs using lithographic methods. The Majorana zero modes are interrogated using planar tunnel junctions and electrostatic gates to selectively tunnel into designated pairs of Majorana zero modes. We give example of qubit designs and circuits that are particularly suitable for the metal-based heterostructures.

Moodera, Jagadeesh S.↗

Mechanism of activation gating in the full-length KcsA K[superscript +] channel

Using a constitutively active channel mutant, we solved the structure of full-length KcsA in the open conformation at 3.9 {angstrom}. The structure reveals that the activation gate expands about 20 {angstrom}, exerting a strain on the bulge helices in the C-terminal domain and generating side windows large enough to accommodate hydrated K{sup +} ions. Functional and spectroscopic analysis of the gating transition provides direct insight into the allosteric coupling between the activation gate and the selectivity filter. We show that the movement of the inner gate helix is transmitted to the C-terminus as a straightforward expansion, leading to an upward movement and the insertion of the top third of the bulge helix into the membrane. We suggest that by limiting the extent to which the inner gate can open, the cytoplasmic domain also modulates the level of inactivation occurring at the selectivity filter.

99 GENERAL AND MISCELLANEOUS↗

Ion Gating in Nanopore Electrode Arrays with Hierarchically Organized pH-Responsive Block Copolymer Membranes

Inspired by biological ion channels, artificial nanopore-based architectures have been developed for smart ion/molecular transport control with potential applications to iontronics and energy conversion. Advances in nanofabrication technology enable simple, versatile construction methods, and post-fabrication functionalization delivers nanochannels with unique ion transport-control attributes. Here, we characterize a pH-responsive, charge-selective dual-gating block copolymer (BCP) membrane composed of polystyrene-b-poly(4-vinylpyridine) (PS 48400 -b-P4VP 21300 ), capable of self-organizing into highly ordered nanocylindrical domains. Because the PS-b-P4VP membrane exhibits pH-dependent structural transitions, it is suitable for designing intelligent pH-gated biomimetic channels, for example, exhibiting on–off transport switching at pH values near the pK a of P4VP with excellent anion permselectivity at pH < pK a . Introducing the BCP membrane onto nanopore electrode arrays (BCP@NEAs) allows the BCP to serve as a pH-responsive gate controlling ion transfer into the NEA nanopores. Such selectively transported and confined ions are detected by using a 100 nm gap dual-ring nanoelectrode structure capable of enhancing current output by efficient redox cycling with an amplification factor >10 2 . In addition, BCP@NEAs exhibit extraordinary pH-gated ion selectivity, resulting in a 3380-fold current difference between anion and cation probes at pH 3.0. Furthermore, this hierarchically organized BCP-gated NEA system can serve as a template for the development of other stimulus-responsive ion gates, for example, those based on temperature and ligand gating, thus exploiting the intrinsic advantages of NEAs, such as enhanced sensitivity based on redox cycling, which may lead to technological applications such as engineered biosensors and iontronic devices.

36 MATERIALS SCIENCE↗

Crystal structure of the ATP-gated P2X[subscript 4] ion channel in the closed state

P2X receptors are cation-selective ion channels gated by extracellular ATP, and are implicated in diverse physiological processes, from synaptic transmission to inflammation to the sensing of taste and pain. Because P2X receptors are not related to other ion channel proteins of known structure, there is at present no molecular foundation for mechanisms of ligand-gating, allosteric modulation and ion permeation. Here we present crystal structures of the zebrafish P2X{sub 4} receptor in its closed, resting state. The chalice-shaped, trimeric receptor is knit together by subunit-subunit contacts implicated in ion channel gating and receptor assembly. Extracellular domains, rich in {beta}-strands, have large acidic patches that may attract cations, through fenestrations, to vestibules near the ion channel. In the transmembrane pore, the 'gate' is defined by an {approx}8 {angstrom} slab of protein. We define the location of three non-canonical, intersubunit ATP-binding sites, and suggest that ATP binding promotes subunit rearrangement and ion channel opening.

36 MATERIALS SCIENCE↗

Gate-controlled ultraviolet photo-etching of graphene edges

The chemical reactivity of graphene under ultraviolet (UV) light irradiation is investigated under positive and negative gate electric fields. Graphene edges are selectively etched when negative gate voltages are applied while the reactivity is significantly suppressed for positive gate voltages. Oxygen adsorption onto graphene is significantly affected by the Fermi level of the final state achieved during previous electrical measurements. UV irradiation after negative-to-positive gate sweeps causes predominant oxygen desorption while UV irradiation after gate sweeps in the opposite direction causes etching of graphene edges.

36 MATERIALS SCIENCE↗

Non-gated laser-induced breakdown spectroscopy in bulk water by position-selective detection

Temporal and spatial evolutions of the laser-induced plasma in bulk water are investigated using fast imaging and emission spectroscopic techniques. By tightly focusing a single-pulse nanosecond Nd: YAG laser beam into the bulk water, we generate a strongly expanded plasma with high reproducibility. Such a strong expanding plasma enables us to obtain well-resolved spectral lines by means of position-selective detection; hence, the time-gated detector becomes abdicable. The present results suggest not only a possible non-gated approach for underwater laser-induced breakdown spectroscopy but also give an insight into the plasma generation and expansion in bulk water.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum calculations on water in the KcsA channel cavity with permeant and non-permeant ions

Different ions in the pore of the KcsA channel behave differently, and we relate this to their solvation. We show that the selectivity is dependent, in part, on the solvation in the cavity (sometimes referred to as the vestibule, it is the region containing water molecules between the intracellular gate and the selectivity filter at the extracellular end of the pore). We have shown earlier that potassium is more dependent at the upper end of the cavity region on solvation by the threonines there, while sodium ion has more water molecules as ligands. In addition, sodium ion is placed asymmetrically, while potassium is nearly exactly symmetric with respect to the four-fold symmetry of the channel. We have now extended these calculations to rubidium and cesium ions, and find that rubidium solvation resembles that of potassium (and both are permeant ions), while cesium resembles sodium (and both are non-permeant), in terms of the geometry of up to eight hydrating, and four non-hydrating, water molecules. In each case, a maximum of 12 water molecules are relevant to the calculation. The placement of the water molecules in the two cases is essentially the same as found from the electron density in the X-ray structure of Zhou and MacKinnon. For Na+ and K+, we show that energy decreases from bulk to the cavity to the lowest position in the selectivity filter (accurate energy could not be calculated for the heavier ions). A separate calculation shows that fixing the Na+ ion at the position of the K+ minimum, followed by re-optimization produced a significantly modified system, not something that could be produced by thermal fluctuations. Moving the K+ into the Na+ position in the upper cavity led to a small increase in energy, ≈ 3 kBT, but was accompanied by large shifts in the positions of hydrating waters, which would create a major kinetic barrier. Therefore, thermal fluctuations could not invalidate the conclusions of the main calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Reduction of skin effect losses in double-level-T-gate structure

We developed a T-gate technology based on selective wet etching yielding 200 nm wide T-gate structures used for fabrication of High Electron Mobility Transistors (HEMT). Major advantages of our process are the use of only standard photolithographic process and the ability to generate T-gate stacks. A HEMT fabricated on AlGaN/GaN/sapphire with gate length L{sub g} = 200 nm and double-stacked T-gates exhibits 60 GHz cutoff frequency showing ten-fold improvement compared to 6 GHz for the same device with 2 μm gate length. HEMTs with a double-level-T-gate (DLTG) structure exhibit up to 35% improvement of f{sub max} value compared to a single T-gate device. This indicates a significant reduction of skin effect losses in DLTG structure compared to its standard T-gate counterpart. These results agree with the theoretical predictions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Let Each Quantum Bit Choose Its Basis Gates

Near-term quantum computers are primarily limited by errors in quantum operations (or gates) between two quantum bits (or qubits). A physical machine typically provides a set of basis gates that include primitive 2-qubit (2Q) and 1-qubit (1Q) gates that can be implemented in a given technology. 2Q entangling gates, coupled with some 1Q gates, allow for universal quantum computation. In superconducting technologies, the current state of the art is to implement the same 2Q gate between every pair of qubits (typically an XX-or XY-type gate). This strict hardware uniformity requirement for 2Q gates in a large quantum computer has made scaling up a time and resource-intensive endeavor in the lab. We propose a radical idea – allow the 2Q basis gate(s) to differ between every pair of qubits, selecting the best entangling gates that can be calibrated between given pairs of qubits. This work aims to give quantum scientists the ability to run meaningful algorithms with qubit systems that are not perfectly uniform. Scientists will also be able to use a much broader variety of novel 2Q gates for quantum computing. We develop a theoretical framework for identifying good 2Q basis gates on “nonstandard” Cartan trajectories that deviate from “standard” trajectories like XX. We then introduce practical methods for calibration and compilation with nonstandard 2Q gates, and discuss possible ways to improve the compilation. To demonstrate our methods in a case study, we simulated both standard XY-type trajectories and faster, nonstandard trajectories using an entangling gate architecture with far-detuned transmon qubits. We identify efficient 2Q basis gates on these nonstandard trajectories and use them to compile a number of standard benchmark circuits such as QFT and QAOA. Furthermore, our results demonstrate an 8x improvement over the baseline 2Q gates with respect to speed and coherence-limited gate fidelity.

quantum computing↗

Fast Sideband Control of a Weakly Coupled Multimode Bosonic Memory

Circuit quantum electrodynamics (cQED) with superconducting cavities coupled to nonlinear circuits like transmons offers a promising platform for hardware-efficient quantum information processing. We address critical challenges in realizing this architecture by weakening the dispersive coupling while also demonstrating fast, high-fidelity multimode control by dynamically amplifying gate speeds through transmon-mediated sideband interactions. This approach enables transmon-cavity SWAP gates, for which we achieve speeds up to 30 times larger than the bare dispersive coupling. Combined with transmon rotations, this allows for efficient, universal state preparation in a single cavity mode, though achieving unitary gates and extending control to multiple modes remains a challenge. In this work, we overcome this by introducing two sideband control strategies: (1) a shelving technique that prevents unwanted transitions by temporarily storing populations in sideband-transparent transmon states and (2) a method that exploits the dispersive shift to synchronize sideband transition rates across chosen photon-number pairs to implement transmon-cavity SWAP gates that are selective on photon number. We leverage these protocols to prepare Fock and binomial code states across any of ten modes of a multimode cavity with millisecond cavity coherence times. We demonstrate the encoding of a qubit from a transmon into arbitrary vacuum and Fock state superpositions, as well as entangled NOON states of cavity mode pairs— a scheme extendable to arbitrary multimode Fock encodings. Furthermore, we implement a new binomial encoding gate that converts arbitrary transmon superpositions into binomial code states in $\qty{4}{\micro\second}$ (less than $1/\chi$), achieving an average post-selected final state fidelity of $\qty{96.3}{\percent}$ across different fiducial input states.

Huang, Jordan [Rutgers U., Piscataway]↗

SU-E-T-403: Evaluation of the Beam Performance of a Varian TrueBeam Linear Accelerator Under External Device-Based Gated Delivery Conditions

Purpose: To examine the beam performance of a Varian TrueBeam linear accelerator under external device-based gated delivery conditions. Methods: Six gating cycles were used to evaluate the gating performance of a standard production TrueBeam system that was not specially tuned in any way. The system was equipped with a factory installed external gating interface (EXGI). An in-house EXGI tester box was used to simulate the input gating signals. The gating cycles were selected based on long beam-on and short beam-off times, short beam-on and long beam-off times, or equal beam on and off times to check linac performance. The beam latencies were measured as the time difference between the logic high gating signal and the first or last target pulses with an oscilloscope. Tissue-Phantom Ratio, beam flatness, and dose distributions from 5 different plans were measured using the 6 different gating durations and the un-gated irradiation. A PTW 729 2-D array was used to compare 5 plans versus the un-gated delivery with a 1%/1mm gamma index passing criteria. Results: The beam latencies of the linac were based off of 20 samples for beam-on and beam-off, for each gating cycle. The average beam-on delays were measured to be between 57 and 66msec, with a maximum of 88 msec. The beam off latencies averaged between 19 and 26msec, with a maximum of 48 msec. TPR20,10 measurements showed beam energy stability within 0.5% of the un-gated delivery. Beam flatness was better than 2.5% for all gated cycles. All but two deliveries, the open field with 4 seconds on, 1 second off, and a five field IMRT plan with 0.5 seconds on, 2.5 seconds off, had >90% passing rate. Conclusion: TrueBeam demonstrates excellent beam stability with minimal beam latencies under external device-based gated operations. Dosimetric measurements show minimal variation in beam energy, flatness, and plan delivery. Authors are employees of Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

Cyclic Nucleotide Gated Channels 7 and 8 Are Essential for Male Reproductive Fertility

The Arabidopsis thaliana genome contains 20 CNGCs, which are proposed to encode cyclic nucleotide gated, non-selective, Ca 2+ -permeable ion channels. CNGC7 and CNGC8 are the two most similar with 74% protein sequence identity, and both genes are preferentially expressed in pollen. Two independent loss-of-function T-DNA insertions were identified for both genes and used to generate plant lines in which only one of the two alleles was segregating (e.g., cngc7-1+/-/cngc8-2-/- and cngc7-3-/-/cngc8-1+/-). While normal pollen transmission was observed for single gene mutations, pollen harboring mutations in both cngc7 and 8 were found to be male sterile (transmission efficiency reduced by more than 3000-fold). Pollen grains harboring T-DNA disruptions of both cngc7 and 8 displayed a high frequency of bursting when germinated in vitro. The male sterile defect could be rescued through pollen expression of a CNGC7 or 8 transgene including a CNGC7 with an N-terminal GFP-tag. However, rescue efficiencies were reduced ~10-fold when the CNGC7 or 8 included an F to W substitution (F589W and F624W, respectively) at the junction between the putative cyclic nucleotide binding-site and the calmodulin binding-site, identifying this junction as important for proper functioning of a plant CNGC. Using confocal microscopy, GFP-CNGC7 was found to preferentially localize to the plasma membrane at the flanks of the growing tip. Together these results indicate that CNGC7 and 8 are at least partially redundant and provide an essential function at the initiation of pollen tube tip growth.

59 BASIC BIOLOGICAL SCIENCES↗

Dosimetric evaluation of the interplay effect in respiratory-gated RapidArc radiation therapy

Purpose: Volumetric modulated arc therapy (VMAT) with gating capability has had increasing adoption in many clinics in the United States. In this new technique, dose rate, gantry rotation speed, and the leaf motion speed of multileaf collimators (MLCs) are modulated dynamically during gated beam delivery to achieve highly conformal dose coverage of the target and normal tissue sparing. Compared with the traditional gated intensity-modulated radiation therapy technique, this complicated beam delivery technique may result in larger dose errors due to the intrafraction tumor motion. The purpose of this work is to evaluate the dosimetric influence of the interplay effect for the respiration-gated VMAT technique (RapidArc, Varian Medical Systems, Palo Alto, CA). Our work consisted of two parts: (1) Investigate the interplay effect for different target residual errors during gated RapidArc delivery using a one-dimensional moving phantom capable of producing stable sinusoidal movement; (2) Evaluate the dosimetric influence in ten clinical patients’ treatment plans using a moving phantom driven with a patient-specific respiratory curve. Methods: For the first part of this study, four plans were created with a spherical target for varying residual motion of 0.25, 0.5, 0.75, and 1.0 cm. Appropriate gating windows were applied for each. The dosimetric effect was evaluated using EDR2 film by comparing the gated delivery with static delivery. For the second part of the project, ten gated lung stereotactic body radiotherapy cases were selected and reoptimized to be delivered by the gated RapidArc technique. These plans were delivered to a phantom, and again the gated treatments were compared to static deliveries by the same methods. Results: For regular sinusoidal motion, the dose delivered to the target was not substantially affected by the gating windows when evaluated with the gamma statistics, suggesting the interplay effect has a small role in respiratory-gated RapidArc therapy. Varied results were seen when gated therapy was performed on the patient plans that could only be attributed to differences in patient respiratory patterns. Patients whose plans had the largest percentage of pixels failing the gamma statistics exhibited irregular breathing patterns including substantial interpatient variation in depth of respiration. Conclusions: The interplay effect has a limited impact on gated RapidArc therapy when evaluated with a linear phantom. Variations in patient breathing patterns, however, are of much greater clinical significance. Caution must be taken when evaluating patients’ respiratory efforts for gated arc therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recent Progress on Exciton Polaritons in Layered Transition-Metal Dichalcogenides

Exciton polaritons (EPs) are half-light, half-matter quasiparticles formed due to the coupling between photons and excitons in semiconductors. Their uniqueness lies at the strong light–matter interactions and long-distance transport, thus promising for many novel applications in photonics, information, and quantum technologies. Recently, EPs in group-VI transition-metal dichalcogenides (TMDs) have attracted a lot of research interest due to their room-temperature stability, long-distance propagation, and controllability through electric gating, valley-selective optical pumping, and precise thickness control. Here, recent studies of EPs in TMDs are reviewed, highlighting their key properties and functionalities, and then discussing the potential directions for future research.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗