Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gene Transfer Techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

40 records · Page 3

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗

Truly incomplete and complex exchanges in prematurely condensed chromosomes of human fibroblasts exposed in vitro to energetic heavy ions

Confluent human fibroblast cells (AG1522) were irradiated with gamma rays, 490 MeV/nucleon silicon ions, or iron ions at either 200 or 500 MeV/nucleon. The cells were allowed to repair at 37 degrees C for 24 h after exposure, and a chemically induced premature chromosome condensation (PCC) technique was used to condense chromosomes in the G2 phase of the cell cycle. Incomplete and complex exchanges were analyzed in the irradiated samples. To verify that chromosomal breaks were truly unrejoined, chromosome aberrations were analyzed using a combination of whole-chromosome specific probes and probes specific for the telomere region of the chromosome. Results showed that the frequency of unrejoined chromosome breaks was higher after irradiation with the heavy ions of high LET, and consequently the ratio of incomplete to complete exchanges increased steadily with LET up to 440 keV/microm, the highest LET included in the present study. For samples exposed to 200 MeV/nucleon iron ions, chromosome aberrations were analyzed using the multicolor FISH (mFISH) technique, which allows identification of both complex and truly incomplete exchanges. Results of the mFISH study showed that 0.7 and 3 Gy iron ions produced similar ratios of complex to simple exchanges and incomplete to complete exchanges; these ratios were higher than those obtained after exposure to 6 Gy gamma rays. After 0.7 Gy of iron ions, most complex aberrations were found to involve three or four chromosomes, which is a likely indication of the maximum number of chromosome domains traversed by a single iron-ion track.

NASA Discipline Radiation Health↗

Light Energy Transduction in Green Sulfur Bacteria

Green sulfur bacteria (GSB) are exquisitely adapted for growth at extraordinarily low light intensities. They are important primary producers of biomass in many anoxic environments, and they contribute significantly to the biogeochemical cycling of carbon, nitrogen, and sulfur on Earth. Green bacteria more generally share the property of using chlorosomes for light-harvesting, and these unusual organelles have many unique features. These include the presence of a monolayer lipid-protein envelope, self-assembling bacteriochlorophylls (BChl) in which pigment-pigment interactions predominate, and the presence of redox components ([2Fe-2S] ferredoxins and quinones) that play a role in regulating excitation energy transfer to the type-1 homodimeric reaction centers. The reaction centers of GSB are related to Photosystem I of cyanobacteria and higher plants but also exhibit several unique structural and functional features. The long-term objectives of this research program are to understand the structure, functions, and biogenesis of the chlorosomes, reaction centers, and electron transport chains that carry out the photochemical transduction of light energy into chemical energy in the model green sulfur bacterium, Chlorobaculum (formerly Chlorobium) tepidum. Over a period of 26 years, we characterized chlorosomes in detail. We identified the proteins in the chlorosome envelopes of diverse organisms, identified the nearest neighbors of those proteins, and characterized the chlorosomes of mutant strains lacking one to five of these proteins. After the genome sequence of Cba. tepidum became available, we identified all genes encoding enzymes for BChl a , BChl c/d/e/ƒ , and Chl a biosynthesis Cba. tepidum . We additionally identified all genes encoding enzymes for carotenoid biosynthesis. By constructing a bchQRU mutant strain that produces [Et, Me]-BChl d , together with collaborators who are specialists in solid-state NMR and cryo-electron microscopy, we solved the structure of the BChls in chlorosomes. Using similar methods and chlorosomes containing [Et, Me]-BChl c , we then showed that alternative structures were possible using the same syn-anti BChl dimer. The structures were refined by introducing spectroscopic data from single-chlorosome measurements. Over the course of this project, we sequenced the genomes of approximately twenty GSB strains, which provided important information for comparative analyses. Through analyses of metagenomic data from Mushroom and Octopus Springs in Yellowstone National Park, we identified a novel chlorophototroph belonging to the phylum Acidobacteriota. We successfully isolated an axenic culture of this organism. We characterized the photosynthetic apparatus of this bacterium, named Chloracidobacterium thermophilum, in significant detail, in particular its type-1, homodimeric reaction centers. Surprisingly, these reaction centers contain three types of Chls, BChl a , Chl a , and Zn-BChl a' . We showed that a dimer of Zn-BChl a' is the primary donor and Chl a the primary acceptor of electrons in this reaction center by using advanced spectroscopic techniques. We isolated eight additional strains of Chloracidobacterium spp. from Mushroom Spring and Rupite hot springs in Bulgaria. Comparative genomes showed that these represent three species, Cab. thermophilum , Cab. aggregatum , and Cab. validum . By applying comparative genomics, genetic, biochemical biophysical and physiological approaches to study green bacteria, we produced a wealth of new information about the remarkable light-harvesting and energy transduction capabilities of these poorly characterized microorganisms.

59 BASIC BIOLOGICAL SCIENCES↗

Deep Space navigation for the BioSentinel spacecraft science orbit

BioSentinel is an astrobiology small spacecraft mission. The payload consists of two parts, the first has optical and microfluidics sensors, and the second is a Linear Energy Transfer spectrometer that has the objective to measure deep space radiation from events such as coronal mass ejections. The goal of the mission is to observe potential DNA damage due to the radiation in heliocentric space on the living organism Saccharomyces cerevisiae, which is a budding yeast. Two types of this living organism are included in the payload. The first is a natural type that is more radiation tolerant, while the second is a mutant strain that has a deficiency in a gene that allows DNA repair once damage occurs. The impact caused by the radiation on the DNA is compared to an identical sample aboard the International Space Station, as well as another identical sample at a laboratory on the ground. The BioSentinel mission consists of a 6U CubeSat currently ,as of January 2024, active in heliocentric orbit. The spacecraft was launched aboard the first SLS flight as part of the Artemis-I campaign in November 2022. After successful deployment from the launch vehicle, it performed a lunar flyby with an altitude of 406 km. The delta-V imparted by the flyby provided the necessary energy to achieve a heliocentric orbit, in an Earth-trailing pattern. The navigation analysis consisted of a Kalman-filter that utilized data from the Deep Space Network and the ESA Estrack network. All those antennas were needed since the Artemis-1 campaign included the deployment of several other cubesats, therefore the scheduling process required more antenna assets than usual due to simultaneous demands from various missions. The processed tracking data was later also refined with a smoother in order to obtain a more accurate solution. The type of tracking data included TCP, Sequential Range, Doppler and Range formats. The solar radiation pressure coefficient, as well as the delta-V from the deployment and the flyby were modeled to obtain suitable solutions that could decrease the position and velocity uncertainties at several steps along the mission concept of operations. The final product each time resulted in updated ephemeris files that were used by the mission and the antenna networks as the mission progressed. Once in the final science orbit, the utilized antennas are only from the DSN network and the data format is bounded to just TCP. Regular orbit determination is performed, every two weeks. The spacecraft is in a nominal well-known orbit, performing regular operations. This paper includes an analysis of the final science orbit, the techniques and procedures utilized to perform orbit determination and a description of the overall navigation campaign produced during the mission and, more specifically, during the final science operations in Deep Space.

BioSentinel↗