Search NASA⌕ Search

SEARCH · Search NASA

Results for “Geothermal Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dixie Valley Engineered Geothermal System Exploration Methodology Project, Baseline Conceptual Model Report

The Engineered Geothermal System (EGS) Exploration Methodology Project is developing an exploration approach for EGS through the integration of geoscientific data. The Project chose the Dixie Valley Geothermal System in Nevada as a field laboratory site for methodlogy calibration purposes because, in the public domain, it is a highly characterized geothermal systems in the Basin and Range with a considerable amount of geoscience and most importantly, well data. This Baseline Conceptual Model report summarizes the results of the first three project tasks (1) collect and assess the existing public domain geoscience data, (2) design and populate a GIS database, and (3) develop a baseline (existing data) geothermal conceptual model, evaluate geostatistical relationships, and generate baseline, coupled EGS favorability/trust maps from +1km above sea level (asl) to -4km asl for the Calibration Area (Dixie Valley Geothermal Wellfield) to identify EGS drilling targets at a scale of 5km x 5km. It presents (1) an assessment of the readily available public domain data and some proprietary data provided by Terra-Gen Power, LLC, (2) a re-interpretation of these data as required, (3) an exploratory geostatistical data analysis, (4) the baseline geothermal conceptual model, and (5) the EGS favorability/trust mapping. The conceptual model presented applies to both the hydrothermal system and EGS in the Dixie Valley region.

15 GEOTHERMAL ENERGY↗

Three-Dimensional Geologic Characterization of a Great Basin Geothermal System: Astor Pass, Nevada

The Great Basin, western USA, exhibits anomalously high heat flow (~75±5 mWm-2) and active faulting and extension, resulting in ~430 known geothermal systems. Recent studies have shown that steeply dipping normal faults in transtensional pull-aparts are a common structural control of these Great Basin geothermal systems. The Astor Pass blind (no surface expression) geothermal system, Nevada, lies along the boundary between the Basin and Range to the east and the Walker Lane to the west. Across this boundary, strain is transferred from dextral shear in the Walker Lane to west-northwest directed extension in the Basin and Range, resulting in a transtensional setting consisting of both northwest-striking, left-stepping dextral faults and northerly striking normal faults. Previous studies indicate that Astor Pass was controlled by the intersection of a northwest-striking dextral normal fault and north-northwest striking normal-dextral fault bounding the western side of the Terraced Hills. Drilling (to ~1200 m) has revealed fluid temperatures of ~94°C, confirming a blind geothermal system. Expanding upon previous work and employing interpretation of 2D seismic reflection data, additional detailed geologic mapping, and well cuttings analysis, a 3-dimensional geologic model of the Astor Pass geothermal system was constructed. The 3D model indicates a complex interaction/intersection area of three discrete fault zones: a northwest-striking dextral-normal fault, a north-northwest-striking normal-dextral fault, and a north-striking west-dipping normal fault. These two discrete, critically-stressed intersection areas plunge moderately to steeply to the NW-NNW and probably act as conduits for upwelling geothermal fluids.

15 GEOTHERMAL ENERGY↗

A conceptual geochemical model of the geothermal system at Surprise Valley, CA

Characterizing the geothermal system at Surprise Valley (SV), northeastern California, is important for determining the sustainability of the energy resource, and mitigating hazards associated with hydrothermal eruptions that last occurred in 1951. Previous geochemical studies of the area attempted to reconcile different hot spring compositions on the western and eastern sides of the valley using scenarios of dilution, equilibration at low temperatures, surface evaporation, and differences in rock type along flow paths. These models were primarily supported using classical geothermometry methods, and generally assumed that fluids in the Lake City mud volcano area on the western side of the valley best reflect the composition of a deep geothermal fluid. In this contribution, we address controls on hot spring compositions using a different suite of geochemical tools, including optimized multicomponent geochemistry (GeoT) models, hot spring fluid major and trace element measurements, mineralogical observations, and stable isotope measurements of hot spring fluids and precipitated carbonates. We synthesize the results into a conceptual geochemical model of the Surprise Valley geothermal system, and show that high-temperature (quartz, Na/K, Na/K/Ca) classical geothermometers fail to predict maximum subsurface temperatures because fluids re-equilibrated at progressively lower temperatures during outflow, including in the Lake City area. We propose a model where hot spring fluids originate as a mixture between a deep thermal brine and modern meteoric fluids, with a seasonally variable mixing ratio. The deep brine has deuterium values at least 3 to 4‰ lighter than any known groundwater or high-elevation snow previously measured in and adjacent to SV, suggesting it was recharged during the Pleistocene when meteoric fluids had lower deuterium values. The deuterium values and compositional characteristics of the deep brine have only been identified in thermal springs and groundwater samples collected in proximity to structures that transmit thermal fluids, suggesting the brine may be thermal in nature. On the western side of the valley at the Lake City mud volcano, the deep brine-meteoric water mixture subsequently boils in the shallow subsurface, precipitates calcite, and re-equilibrates at about 130 °C. On the eastern side of the valley, meteoric fluid mixes to a greater extent with the deep brine, cools conductively without boiling, and the composition is modified as dissolved elements are sequestered by secondary minerals that form along the cooling and outflow path at temperatures <130 °C. Re-equilibration of geothermal fluids at lower temperatures during outflow explains why subsurface temperature estimates based on classical geothermometry methods are highly variable, and fail to agree with temperature estimates based on dissolved sulfate-oxygen isotopes and results of classical and multicomponent geothermometry applied to reconstructed deep well fluids. Furthermore, the proposed model is compatible with the idea suggested by others that thermal fluids on the western and eastern side of the valley have a common source, and supports the hypothesis that low temperature re-equilibration during west to east flow is the major control on hot spring fluid compositions, rather than dilution, evaporation, or differences in rock type.

15 GEOTHERMAL ENERGY↗

Geophysical Investigations of a Blind Geothermal System in Southern Gabbs Valley, Nevada

Southern Gabbs Valley in west-central Nevada, is a blind geothermal system located 5 km north of the Gabbs Valley Range and ~15 km southeast of the Don A. Campbell geothermal power plant. Previous geologic, geophysical, and geochemical studies in the Nevada play fairway project had identified a favorable setting for a blind geothermal system, documented elevated subsurface temperatures, and established the structural framework of the area. Further high resolution geophysical surveys were therefore conducted to aid in characterizing both the intrabasinal structure of the area and potential geothermal system. A total of 480 gravity stations, 300 km of ground magnetic data, and 24 magnetotelluric (MT) stations were collected. These data support the previous interpretation that the thermal anomaly occurs at the intersection of two faults bounding an intra-basin gravity high, and also show that a conductive zone (potential cap) and magnetic low coincide with this anomaly. If the magnetic low is a result of hydrothermal alteration that has demagnetized the surrounding rock, this would suggest that this is a relatively long lived geothermal system, adding to the viability of the resource.

15 GEOTHERMAL ENERGY↗

Discovering Geothermal Systems in the Great Basin Region: An Integrated Geologic, Geochemical, and Geophysical Approach for Establishing Geothermal Play Fairways

The Great Basin currently hosts ~24 geothermal power plants with more than 600 MW of capacity, but estimates suggest that the region is capable of producing much greater amounts of geothermal energy. Recent studies indicate that a combination of geological, geochemical, and geophysical features characterize the most robust geothermal systems. Considering that most of the geothermal resources in this region are blind, it is imperative that the favorable characteristics for geothermal activity be synthesized and techniques perfected for the discovery of new viable systems. We therefore utilized a multi-disciplinary approach and synthesized 9 geologic, geochemical, and geophysical parameters to produce a new detailed geothermal play fairway map of a large transect across the Great Basin region (96,000 km2) from west-central to eastern Nevada, with the primary objective of facilitating discovery of commercial-grade, blind geothermal fields (i.e. systems with no surface hot springs or fumaroles). Our analysis included: 1) structural settings (i.e., patterns of faulting), 2) age of recent faulting, 3) slip rates on recent faults, 4) regional-scale strain rates, 5) the tendency of faults to slip or dilate based on their orientation in the regional stress field, 6) earthquake density, 7) gravity data, 8) temperature at 3 km depth, and 9) geochemistry from springs and wells. These parameters were grouped into subsets to delineate rankings for local permeability, regional permeability, and heat, which collectively defined the geothermal play fairways (i.e., most likely locations for significant geothermal fluid flow). A major challenge was developing appropriate weightings of individual data types to best predict permeability and overall geothermal potential. Rigorous statistical methods, utilizing 34 benchmarks of known relatively high-temperature (>130°C) geothermal systems in the region, were employed to determine the hierarchal weights of each parameter. The new geothermal potential maps will help to reduce the risks in prospecting for new geothermal systems throughout the region.

15 GEOTHERMAL ENERGY↗

STRUCTURAL CONTROLS OF THE EMERSON PASS GEOTHERMAL SYSTEM, NORTHWESTERN NEVADA: CHARACTERIZATION OF A "BLIND" SYSTEM

The Pyramid Lake area is favorable for geothermal development due to the tectonic setting of the region. The Walker Lane belt, a dextral shear zone that accommodates ~20% relative motion between the Pacific and North American plates, terminates northwestward in northeast California. NW-directed dextral shear is transferred to WNW extension accommodated by N-to -NNE striking normal faults of the Basin and Range. As a consequence, enhanced dilation occurs on favorably oriented faults generating high geothermal potential in the northwestern Great Basin. The NW-striking right-lateral Pyramid Lake fault, a major structure of the northern Walker Lane, terminates at the southern end of Pyramid Lake and transfers strain to the NNE-striking down to the west Lake Range fault, resulting in high geothermal potential. Known geothermal systems in the area have not been developed due to cultural considerations of the Pyramid Lake Paiute Tribe. Therefore, exploration has been focused on discovering blind geothermal systems elsewhere on the reservation by identifying structurally favorable settings and indicators of past geothermal activity. One promising area is the northeast end of Pyramid Lake, where a broad left step between the west-dipping range-bounding faults of the Lake and Fox Ranges has led to the formation of a broad, faulted relay ramp. Furthermore, tufa mounds, mineralized veins, and altered Miocene rocks occur proximal to a thermal anomaly discovered by a 2-m shallow temperature survey at the north end of the step-over in Emerson Pass. Detailed geologic mapping has revealed a system of mainly NNE-striking down to the west normal faults. However, there are three notable exceptions to this generality, including 1) a prominent NW-striking apparent right-lateral fault, 2) a NW-striking down to the south fault which juxtaposes the base of the mid-Miocene Pyramid sequence against younger late Tertiary sedimentary rocks, and 3) a NNE-striking down to the east normal fault, which accommodates motion such that the Mesozoic Nightingale sequence is juxtaposed with late Tertiary sedimentary rocks. The NW dextral fault, the NNE-down to east fault, and several NNE-down to the west faults intersect roughly at the thermal anomaly in Emerson Pass. This suggests that fault intersections locally control upwelling of geothermal fluids within the step-over. Based on this assumption, it is proposed that the area near Buckbrush Springs be investigated further for geothermal potential. At this location, a NNE-down to the west normal fault, with >1 km of offset, intersects a NW-striking down to the south fault at a small left step in the NNE fault. Further studies will include collection of available kinematic indicators near the shallow thermal anomaly in Emerson Pass, geothermometry on Buckbrush Spring, and possibly drilling of temperature gradient wells in Emerson Pass and at Buckbrush Spring.

15 GEOTHERMAL ENERGY↗

Geo-Responsive Chemomechanics in Aluminum Oxyhydroxide via Alkali-Driven Dehydroxylation for Supercritical Geothermal Systems

Widespread use of enhanced geothermal systems can revolutionize global renewable electrical power access, yet its advancement is hindered by the inherent instability of Portland cement-based chemistries for geothermal well construction under high-temperature corrosive conditions. Here, in this work, we demonstrate the tunable mechanical performance of aluminum oxyhydroxides as cementitious materials through an alkali-controlled dehydroxylation reaction pathway for long-term applications under supercritical geothermal environments. Notably, the synthesized aluminum oxyhydroxides demonstrate remarkable stability, maintaining superior mechanical performance under supercritical conditions for over 30 days. Synchrotron X-ray diffraction, spectroscopy measurements and geochemical thermodynamic modeling uncover that the gibbsite dehydroxylation pathway functions as a key dial for tuning the chemomechanics, rendering the aluminum oxyhydroxide a strong cementitious material. By uncovering the mechanistic role of alkali-driven dehydroxylation, this work proposes a cementitious chemistry distinct from conventional Portland cement and geopolymer-dominated alkali-activated systems, laying the groundwork for developing next-generation cementitious materials for supercritical geothermal energy exploitation.

15 GEOTHERMAL ENERGY↗

3D characterization of the Astor Pass geothermal system, Nevada

The Astor Pass geothermal system resides in the northwestern part of the Pyramid Lake Paiute Reservation, on the margins of the Basin and Range and Walker Lane tectonic provinces in northwestern Nevada. Seismic reflection interpretation, detailed analysis of well cuttings, stress field analysis, and construction of a 3D geologic model have been used in the characterization of the stratigraphic and structural framework of the geothermal area. The area is primarily comprised of middle Miocene Pyramid sequence volcanic and sedimentary rocks, nonconformably overlying Mesozoic metamorphic and granitic rocks. Wells drilled at Astor Pass show a ~1 km thick section of highly transmissive Miocene volcanic reservoir with temperatures of ~95°C. Seismic reflection interpretation confirms a high fault density in the geothermal area, with many possible fluid pathways penetrating into the relatively impermeable Mesozoic basement. Stress field analysis using borehole breakout data reveals a complex transtensional faulting regime with a regionally consistent west-northwest-trending least principal stress direction. Considering possible strike-slip and normal stress regimes, the stress data were utilized in a slip and dilation tendency analysis of the fault model, which suggests two promising fault areas controlling upwelling geothermal fluids. Both of these fault intersection areas show positive attributes for controlling geothermal fluids, but hydrologic tests show the ~1 km thick volcanic section is highly transmissive. Thus, focused upwellings along discrete fault conduits may be confined to the Mesozoic basement before fluids diffuse into the Miocene volcanic reservoir above. This large diffuse reservoir in the faulted Miocene volcanic rocks is capable of sustaining high pump rates. Understanding this type of system may be helpful in examining large, permeable reservoirs in deep sedimentary basins of the eastern Basin and Range and the highly fractured volcanic geothermal reservoirs in the Snake River Plain.

15 GEOTHERMAL ENERGY↗

Numerical modeling of injection, stress and permeability enhancement during shear stimulation at the Desert Peak Enhanced Geothermal System

Creation of an Enhanced Geothermal System relies on stimulation of fracture permeability through self-propping shear failure that creates a complex fracture network with high surface area for efficient heat transfer. In 2010, shear stimulation was carried out in well 27-15 at Desert Peak geothermal field, Nevada, by injecting cold water at pressure less than the minimum principal stress. An order-of-magnitude improvement in well injectivity was recorded. In this work, we describe a numerical model that accounts for injection-induced stress changes and permeability enhancement during this stimulation. We use the coupled thermo-hydrological–mechanical simulator FEHM to (i) construct a wellbore model for non-steady bottom-hole temperature and pressure conditions during the injection, and (ii) apply these pressures and temperatures as a source term in a numerical model of the stimulation. A Mohr–Coulomb failure criterion and empirical fracture permeability is developed to describe permeability evolution of the fractured rock. The numerical model is calibrated using laboratory measurements of material properties on representative core samples and wellhead records of injection pressure and mass flow during the shear stimulation. The model captures both the absence of stimulation at low wellhead pressure (WHP ≤1.7 and ≤2.4 MPa) as well as the timing and magnitude of injectivity rise at medium WHP (3.1 MPa). Results indicate that thermoelastic effects near the wellbore and the associated non-local stresses further from the well combine to propagate a failure front away from the injection well. Elevated WHP promotes failure, increases the injection rate, and cools the wellbore; however, as the overpressure drops off with distance, thermal and non-local stresses play an ongoing role in promoting shear failure at increasing distance from the well.

15 GEOTHERMAL ENERGY↗

Using Dark Fiber and Distributed Acoustic Sensing to Characterize a Geothermal System in the Imperial Valley, Southern California

The Imperial Valley, CA, is a tectonically active transtensional basin located south of the Salton Sea; the area hosts numerous geothermal fields, including significant hidden hydrothermal resources without surface manifestations. Development of inexpensive, rugged, and highly sensitive exploration techniques for undiscovered geothermal systems is critical for accelerating geothermal power deployment as well as unlocking a low-carbon energy future. We present a case study utilizing distributed acoustic sensing (DAS) and ambient noise interferometry for geothermal reservoir imaging, utilizing unlit fiber-optic telecommunication infrastructure (dark fiber). The study exploits two days of passive DAS data acquired in early November 2020 over a ~28-km section of fiber from Calipatria, CA to Imperial, CA. We apply ambient noise interferometry to retrieve coherent signals from DAS records and develop a bin stacking technique to attenuate the effects from persistent localized noise sources and to enhance retrieval of coherent surface waves. As a result, we are able to obtain high-resolution two-dimensional (2D) S wave velocity ($V_s$) structure to 3 km depth, based on joint inversion of both the fundamental and higher overtones. We observe a previously unmapped high $V_s$ and low $V_p$/$V_s$ ratio feature beneath the Brawley geothermal system, which we interpret to be a zone of hydrothermal mineralization and lower porosity. This interpretation is consistent with a host of other measurements including surface heat flow, gravity anomalies, and available borehole wireline data. These results demonstrate the potential utility of DAS deployed on dark fiber for geothermal system exploration and characterization in the appropriate geological settings.

Vp/Vs imaging↗

Role of pH and Eh in geothermal systems: Thermodynamic examples and impacts on scaling and corrosion

The global demand for sustainable and clean renewable energy sources is rapidly increasing to meet growing energy demands while curtailing the CO2 emissions from fossil fuels. Harnessing the natural heat or geothermal energy of the Earth's interior can simultaneously address both issues by offering a clean and renewable energy source. Enhanced geothermal systems require the movement and cycling of fluid through a porous rock media. Further, this process requires understanding the chemistry occurring at the fluid-rock and fluid-metal interfaces both in the deep subsurface and surface, where fluid is circulated for energy transfer or storage. In this review paper, we evaluate the current state of research on how two key variables, pH and Eh, control the fluid-rock reactions controlling mineral scaling and the steel corrosion reactions associated with geothermal systems. These variables are frequently used in geochemical modeling to predict chemical reactions in geothermal systems. Prediction of the fluid-rock behavior can be utilized to formulate new strategies for extending the lifespan and efficiency of heat extraction and utilization and maximizing the safety of geothermal systems.

15 GEOTHERMAL ENERGY↗

Code Comparison Study Fosters Confidence in the Numerical Simulation of Enhanced Geothermal Systems

Numerical simulation has become a standard analytical tool for scientists and engineers to evaluate the potential and performance of enhanced geothermal systems. A variety of numerical simulators developed by industry, universities, and national laboratories are currently available and being applied to better understand enhanced geothermal systems at the field scale. To yield credible predictions and be of value to site operators, numerical simulators must be able to accurately represent the complex coupled processes induced by producing geothermal systems, such as fracture aperture changes due to thermal stimulation, fracture shear displacement with fluid injection, rate of thermal depletion of reservoir rocks, and permeability alteration with mineral precipitation or dissolution. A suite of numerical simulators was exercised on a series of test problems that considered coupled thermal, hydraulic, geomechanical, and geochemical (THMC) processes. Problems were selected and designed to isolate selected coupled processes, to be executed on workstation class computers, and have simple but illustrative metrics for result comparisons. This paper summarizes the initial suite of seven benchmark problems, describes the code comparison activities, provides example results for problems and documents the capabilities of currently available numerical simulation codes to represent coupled processes that occur during the production of geothermal resources. Code comparisons described in this paper use the ISO (International Organization for Standardization) standard ISO-13538 for proficiency testing of numerical simulators. This approach was adopted for a recent code comparison study within the radiation transfer-modeling field of atmospheric sciences, which was focused on canopy reflectance models. This standard specifies statistical methods for analyzing laboratory data from proficiency testing schemes to demonstrate that the measurement results do not exhibit evidence of an unacceptable level of bias.

benchmark problems↗

Effect of Glacial/Interglacial Recharge Conditions on Flow of Meteoric Water Through Deep Orogenic Faults: Insights Into the Geothermal System at Grimsel Pass, Switzerland

Many meteoric-recharged, fault-hosted geothermal systems in amagmatic orogenic belts have been active through the Pleistocene glacial/interglacial climate fluctuations. The effects of such climate-induced recharge variations on fluid flow patterns and residence times of the thermal waters are complex and may influence how the geothermal and mineralization potential of the systems are evaluated. We report systematic thermal–hydraulic simulations designed to reveal the effects of recharge variations, using a model patterned on the orogenic geothermal system at Grimsel Pass in the Swiss Alps. Fault-bound circulation of meteoric water through the Grimsel fault is driven to depths of ~10 km by the high alpine topography. Simulations suggest that the current single pass flow is typical of interglacial periods, during which 1) meteoric recharge into the fault is high (above tens of centimeters per year), 2) conditions are at or somewhat below the critical Rayleigh number, and 3) the hydraulic connectivity along the fault plane is extensive (an extent of at least 10 km into increasingly higher terrain is required to explain the 10 km penetration depth). The subcritical condition constrains the bulk fault permeability to < 1e-14 m2. In contrast, the limited recharge during the numerous Pleistocene glaciation events likely induced a layered flow system with single pass flow confined to shallow depths while non-Rayleigh convection occurred in the deep fault. The same layering can be observed at low aspect ratios (length/depth) of the fault plane, when the available recharge area limits the flux through the fault.

58 GEOSCIENCES↗

Completion Design Considerations for a Horizontal Enhanced Geothermal System

The petroleum industry has had considerable success in recent decades in developing unconventional shale plays using horizontal drilling and multi-zonal isolation and stimulation techniques to fracture tight formations to enable the commercial production of oil and gas. Similar well completions could be used in Enhanced Geothermal Systems (EGS) to create multiple fractures from horizontal wells. This study assesses whether well completion techniques used in the unconventional shale industry to create multi-stage fractures can be applied to an enhanced geothermal system, with a focus on the completion of the EGS injection well. This study assumes an Enhanced Geothermal System (EGS) consisting of a central horizontal injection well flanked on each side by horizontal production wells, connected to the injection well by multiple fractures. The focus is on the design and completion of the horizontal well. For the purpose of developing design criteria, a reservoir temperature of 200 degrees C (392 degrees F) and an injection well flow rate of 87,000 barrels per day (160 kg/s), corresponding to production well flow rates of 43,500 barrels per day (80 kg/s) is assumed. The analysis found that 9-5/8 inches 53.5 pounds per foot (ppf) P110 casing string with premium connections meets all design criteria for the horizontal section of injection well. A P110 grade is fairly common and is often used in horizontal sections of shale development wells in petroleum operations. Next, several zonal isolation systems commonly used in the shale gas industry were evaluated. Three techniques were evaluated -- a 'plug and perf' design, a 'sand and perf' design, and a 'packer and port' design. A plug and perf system utilizes a cemented casing throughout the length of the injector wellbore. The sand and perf system is identical to the plug and perf system, but replaces packers with sand placed in the casing after stimulation to screen out the stimulated perforated zones and provide zonal isolation. The packer and port completion approach utilizes an open horizontal hole that zonally isolates areas through the use of external packers and a liner. A review of technologies used in these systems was performed to determine if commercially available equipment from the petroleum industry could be used at the temperatures, pressures, and sizes encountered in geothermal settings. The study found no major technical barriers to employing shale gas multi-zonal completion techniques in a horizontal well in a geothermal setting for EGS development. For all techniques considered, temperature limitations of equipment are a concern. Commercially available equipment designed to operate at the high temperatures encountered in geothermal systems are available, but is generally unproven for geothermal applications. Based on the study, further evaluation of adapting oil and gas completion techniques to EGS is warranted.

15 GEOTHERMAL ENERGY↗

Outcomes from a Collaborative Approach to a Code Comparison Study for Enhanced Geothermal Systems

A code comparison study, supported by the U.S. Department of Energy, Geothermal Technologies Office, has recently been completed whose stated purpose was to test, diagnose differences, and demonstrate the state of modeling capabilities developed at national laboratories and academic institutes within the United States for modeling enhanced geothermal systems. This three-year study comprised two sets of problems; those classified as benchmark problems and those classified as challenge problems. The benchmark problems were structured to test the ability of the collection of numerical simulators to solve various combinations of coupled thermal, hydrologic, geomechanical, and geochemical processes. This class of problems was strictly defined in terms of properties, driving forces, initial conditions, and boundary conditions. Study participants submitted solutions to problems for which their simulation tools were deemed capable or nearly capable. Some participating codes were originally developed for EGS applications whereas some others were designed for different applications but can simulate processes similar to those in EGS. Solution submissions from both were encouraged. In some cases participants made small incremental changes to their numerical simulation codes to address specific elements of the problem, and in other cases participants submitted solutions with existing simulation tools, acknowledging the limitations of the code. The challenge problems were based on the enhanced geothermal systems research conducted in hot dry rock at Fenton Hill, near Los Alamos, New Mexico, between 1974 and 1995, covering two research stimulation, development and circulation phases in two separate reservoirs. Both challenge problems have specific questions to be answered via numerical simulation in three topical areas: 1) reservoir creation/stimulation, 2) reactive and passive transport, and 3) thermal recovery. Whereas the benchmark class of problems were designed to test capabilities for modeling coupled processes under strictly specified conditions, the stated objective for the challenge class of problems was to demonstrate what new understanding of the Fenton Hill experiments could be realized via the application of modern numerical simulation tools by recognized expert practitioners. Critical observations and data from the Fenton Hill experiments were varied and scattered among a number of individual experiments, and numerical simulation solutions were sought that satisfied as many observations at possible. Achieving agreement in multiple experimental observations from Fenton Hill often required participants to critically think about stimulation mechanisms involving natural and hydraulic fractures and re-evaluate their conceptual models and numerical solution approaches. This process has yielded new insights to Fenton Hill reservoirs and direction for future EGS research. The keys to the success of this study were the high quality numerical simulation tools available, the expertise of the developers and practitioners, and the collaborative approach to reporting preliminary results among the study participants. This paper describes results submitted to the challenge problems and the outcomes of a collaborative approach to conducting a code comparison study.

Enhanced Geothermal Systems, numerical simulation,↗

Geophysical Imaging of Geothermal Systems Spanning Various Geologic Settings

Despite the wide range of geologic settings in which geothermal systems reside, many systems share characteristics that can be targeted by geophysical techniques. Over the last few years, the authors have used potential field and magnetotelluric (MT) methods to jointly image and characterize numerous geothermal systems in various geologic and tectonic settings. This includes systems in the Basin and Range, Washington Cascade Range, Northeastern Oregon, and the Snake River Plain. The principal geothermal targets are areas of elevated temperatures near fault interactions that promote permeability and fluid flow. Gravity, magnetic, and MT data are all sensitive to different physical parameters that together form a complementary set of tools for characterizing subsurface structure and identifying favorable geothermal targets. In general, potential fields delineate important geologic structures and MT locates fluids and zones of hydrothermal alteration. Joint interpretation of these complementary methods, along with other geologic information, provides a robust framework for geothermal prospecting and understanding a hydrothermal system. Specifically, common geothermal targets lie along potential field gradients and are associated with an electrically conductive anomaly that resides in the less-dense, less-magnetic material.

15 GEOTHERMAL ENERGY↗

Integrating Magnetotellurics, Soil Gas Geochemistry and Structural Analysis to Identify Hidden, High Enthalpy, Extensional Geothermal Systems

Our research group comprising personnel from University of Utah/EGI (UU/EGI), University of Nevada at Reno (UNR) and Lawrence Berkeley National Laboratory (LBNL) has been applying magnetotellurics (MT), diagnostic structural affiliations, and soil gas flux and geochemistry to assist in identifying hidden, high-enthalpy geothermal systems in extensional regimes of the U.S. Great Basin. We are specifically looking for upwelling low-resistivity and geologic structures that can carry fluids from magmatic or high-grade metamorphic conditions in the deep crust upward to exploitable depths, and to verify the nature of the deep sources through soil gas geochemical compositions. The project was motivated by prior MT transect coverage of western and central Nevada centered upon the Dixie Valley geothermal system where such favorable indicators were first recognized. The high-angle structures are taken to be fluidized fault zones connecting deep magmatic/metamorphic activity with the geothermal system but the concept requires verification by testing at other systems. The project was set up with a two-phased organization. Phase I was carried out at the McGinness Hills system, central Nevada, where Ormat’s flagship power facility is located and a considerable amount of pre-existing data was available. Transect MT data also showed a strong low-resistivity upwelling originating from interpreted deep crustal magmatic underplating. Controlling structures on production as indicated by Ormat data and new mapping by UNR were favorable to dilatency being an accommodation zone between major normal faults of opposing dip. A 3D MT survey and inversion confirmed the existence of the steep low-resistivity zone dipping ESE toward the deep crust and placed N-S bounds upon the feature. Ormat personnel cooperated with PI Wannamaker in the field in providing fluid samples from the production intervals for He isotope composition. Elevated 3He was verified through analysis at LBNL confirming that there was a magmatic connection into the producing system. High CO2 soil gas flux including possibly metamorphic 13C and 14C component was measured over the area of dilatent structures. Hence, the triad of indicators posed above was confirmed in Phase I. Subsequently, Phase II of the project proceeded in the greenfield Kumiva-Blackrock Desert district of northwestern Nevada to see if a new system could be identified. Transect MT data also showed a strong low-resistivity upwelling originating from interpreted deep crustal magmatic underplating. However, given that there was no exploitable geothermal system recognized at the outset in the region, the collection of new geoscientific data was required. An areal MT survey of 131 sites over the Kumiva-Blackrock Desert district was completed, and a 3D inversion produced using the in-house, DOE-supported finite element inversion algorithm. Particular MT low resistivity upwellings that received followup study occurred under the west flank of the Seven Troughs Range, under the playa immediately west of the Blue Wing Mountains, and under northern Granite Springs Valley. Structural assessment of the project area by Co-I J. Faulds at UNR provided numerous favorable Quaternary fault settings, which were correlated to the MT upwelling structures. Extensive profiling for CO2 soil gas flux over favorable geophysical and geological structure was performed by LBNL personnel. Soil gas flux anomalies generally were not large but did show correlation with MT upwelling structure and favorably dilatent geological structures. Isotope analyses showed presence of possible inorganic/metamorphic 13C but 14C concentrations did not exceed background values. We view the initial concept of a confluence of MT low-resistivity upwelling, favorably dilatent 3D geological structure, and elevated soil gas flux including 13C component to be supported by the further evidence of this project although the indicators in the Phase II study were more diffuse. The northern Granite Springs Valley structure is receiving followup in the UNR Play Fairway Analysis, being in the southern termination of a major normal fault with silicified soil and warm temperature probe results

15 GEOTHERMAL ENERGY↗