Search NASA⌕ Search

SEARCH · Search NASA

Results for “Geysers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

43 records · Page 3

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY24 Report on Water NSTF Testing: Lower Tank Inlet Piping Configuration

The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.

42 ENGINEERING↗

Streamlining Energy Sprawl: Assessment of Geothermal Impacts on Public Lands

Renewable energy power generation, including geothermal, solar photovoltaics (PV), and wind, can have significant land use impacts depending on the technology and the size of the facility. At the same time, innovations across these renewable technologies are working to improve plant efficiency per acre of disturbance. Through a survey of satellite imagery and other sources, this analysis reevaluates the impact of geothermal power generation and examines the variations in land use for different geothermal technologies (binary, flash, and dry steam). Geothermal operations on Bureau of Land Management (BLM) sites serve as the focus for this analysis - i.e., only active sites with federal mineral ownership for which the BLM receives royalties from power production. The results show significant variation in direct land disturbance across the operations sites and across these three geothermal technologies. Although there is variation across plants within the same geothermal technology category, dry steam plants (The Geysers) were shown to have the lowest impact, in acres per megawatt capacity and acres per gigawatt-hour generation, followed by flash steam and binary plants. Overall, direct land impacts relative to capacity and generation have declined 16-27% for facilities constructed since 2000 as compared to those constructed prior, even though most new facilities are binary plants (which traditionally had higher land disturbance). Additionally, capacity factors based on actual net production data were found to average only 50% across all operations sites, suggesting that previous estimates based on nameplate capacity only may lead to an undercounting of generation-based land disturbance metrics. Should the geothermal industry capture additional market share, improving land disturbance metrics through accurate net production and capacity data and further minimizing impacts will be increasingly important as competition over land use intensifies.

GEOTHERMAL ENERGY↗

The Impacts of Geothermal Operations on Groundwater

In 2018, the Bureau of Land Management's (BLM's) National Renewable Energy Coordination Office, through its Geothermal Program, funded the National Renewable Energy Laboratory (NREL) to review existing literature for potential cases in which geothermal wells contributed to groundwater contamination. NREL conducted an extensive literature review but was unable to find any cases of groundwater contamination resulting from geothermal operations. This paper includes cases in which wellbore failures did not affect groundwater and areas where geothermal operations may have affected other resources, such as hot springs and geysers.

BLM↗

Shallow Geothermal Resources for Cooling Applications at the University of Hawai'i

Drilling activities account for 30% to 57% of the cost to develop and install a geothermal plant. Therefore, an accurate representation of the cost to drill a well is paramount in techno-economic analysis to determine the feasibility of a geothermal power project. In 2022, the National Renewable Energy Laboratory (NREL) endeavored to revise the U.S. Department of Energy (DOE) GeoVision baseline drilling cost curves due to extensive improvement in drilling rates at the Utah Frontier Observatory Research in Geothermal Energy (FORGE) demonstration site. That effort did not culminate in the recommendation of new curves because the actual project costs did not match the reported performance improvements and were at or above the GeoVision baseline. The need for another iteration of this analysis has arisen from industry record drilling performance reported by recent commercial field-scale and demonstration projects, including Fervo Energy's Cape Station, the Utah FORGE 16B(78)-32 demonstration and the Geysers Power Company's GDC-36 demonstration. Therefore, in this work, we have estimated the resulting industry average rate of penetration (ROP) and bit life and applied these parameters as inputs to the Well Cost Simplified model used in the GeoVision analysis. The resulting revised cost curves show a significant decline from the GeoVision baseline. For vertical wells, the magnitude of cost decline ranges between 12% and 24% while for deviated wells, cost reductions between 18% and 26% are estimated. The revised cost curves are in good agreement with actual cost data and therefore, quantify the economic impact of the utilization of (and advances in) polycrystalline diamond compact (PDC) bit technology and the application of physics-based methodologies that optimize mechanical specific energy.

building cooling↗

2025 Geothermal Drilling Cost Curves Update: Preprint

Drilling activities account for 30% to 57% of the cost to develop and install a geothermal plant. Therefore, an accurate representation of the cost to drill a well is paramount in techno-economic analysis to determine the feasibility of a geothermal power project. In 2022, the National Renewable Energy Laboratory (NREL) endeavored to revise the U.S. Department of Energy (DOE) GeoVision baseline drilling cost curves due to extensive improvement in drilling rates at the Utah Frontier Observatory Research in Geothermal Energy (FORGE) demonstration site. That effort did not culminate in the recommendation of new curves because the actual project costs did not match the reported performance improvements and were at or above the GeoVision baseline. The need for another iteration of this analysis has arisen from industry record drilling performance reported by recent commercial field-scale and demonstration projects, including Fervo Energy’s Cape Station, the Utah FORGE 16B(78)-32 demonstration and the Geysers Power Company’s GDC-36 demonstration. Therefore, in this work, we have estimated the resulting industry average rate of penetration (ROP) and bit life and applied these parameters as inputs to the Well Cost Simplified model used in the GeoVision analysis. The resulting revised cost curves show a significant decline from the GeoVision baseline. For vertical wells, the magnitude of cost decline ranges between 12% and 24% while for deviated wells, cost reductions between 18% and 26% are estimated. The revised cost curves are in good agreement with actual cost data and therefore, quantify the economic impact of the utilization of (and advances in) polycrystalline diamond compact (PDC) bit technology and the application of physics-based methodologies that optimize mechanical specific energy.

15 GEOTHERMAL ENERGY↗

Phenomena Identification and Ranking Table (PIRT) for Heat Pipes

This Phenomena Identification and Ranking Table (PIRT) report provides an evaluation of key phenomena affecting the performance and operational regimes of heat pipes, particularly in the context of heat pipe microreactors (HPMRs). Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in the heat pipe, including phase change, turbulent transition, and compressibility effects, among others, there is high uncertainty in identifying and ranking the important phenomena affecting the operation of heat pipes and the current knowledge for their modeling and simulation and experimental measurements and instrumentation. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. The report analyzes phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics, discussing challenges and future research directions for improving their modeling and simulation and experimental measurements. Additionally, the report addresses phenomena with low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geysering, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. This comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗