Search NASA⌕ Search

SEARCH · Search NASA

Results for “Godiva”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Godiva IV Shielding Benchmark Overview [Slides]

This presentation shows that Integral experiments increase the level of realism from that of data measurements. Further, Godiva IV is capable of intensities to activate foils. IER 498 uses a relative measurement to provide an intermediate level of realism. With reproducibility and room return management are key components. The test matrix put forward in CED-2 enables numerous cross-comparisons. IER 498 facilitates various additional works using a room return shield to isolate the source. IER 557 demonstrated burst reproducibility sufficient for IER 498.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Godiva 4 CAAS Shielding Benchmark: Pre CED-3A Overview [Slides]

Thiis presentation shows the character of an integral experiment. It covers the question why Godiva 4? Additionally, this presentation touches on the IER 498 benchmark quantity, activities facilitated by IER 498, proposed CED-2 test matrix, and what happened during the IER 498’s gap year.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation Characterization Summary: Godiva IV Critical Assembly Environments at the In-Core, Top Hat, 1m, and 2m Irradiation Locations

This document presents the facility-recommended characterization of the neutron, prompt gamma ray, and delayed gamma ray radiation fields at the Godiva IV critical assembly at the National Criticality Experiments Research Center (NCERC). The environments assessed include the In-Core location, a location on the Top Hat, 1m away from the assembly, and 2m away from the assembly. The neutron, prompt gamma ray, and delayed gamma ray energy spectra, uncertainties, and covariance matrices are presented as well as radial and axial neutron and gamma ray fluence profiles on the Top Hat surrounding the critical assembly. Recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse operations are presented with conversion examples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

R-Value Measurements Performed on Actinide Targets Irradiated using the GODIVA IV Critical Assembly in FY22

The separation and characterization of two irradiated uranium targets, a depleted uranium (DU) and a highly enriched uranium (HEU) target as well as a plutonium (Pu) target, was conducted in April of 2022. The three targets were assembled at Los Alamos National Laboratory (LANL) and irradiated using the GODIVA critical assembly at the National Criticality Experiments Research Center (NCERC). Splits of the dissolved targets were received by Pacific Northwest National Laboratory (PNNL) after which the PNNL and LANL teams chemically separated the solutions using independent separation schemes and analyzed the separated fractions for short lived actinides and fission products. Chemical separations were traced with stable or radioactive tracers to allow for the determination of chemical yields, analyzing using either inductively coupled plasma optical emission spectroscopy (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS) or gamma emission analysis (GEA) depending on the nature of the tracer. The Pu target solution was traced with stable elements at LANL to follow elemental fractionation during a Pu removal step. Many analytical techniques were used by PNNL including kinetic phosphorescence analysis (KPA), ICP-OES, ICP-MS, GEA, and thermal ionization mass spectrometry (TIMS) depending on the analyte’s need.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Why Lady Godiva Should be Replaced as the Default Validation Experiment for U-235 Nuclear Data

For the past seven decades the Lady Godiva benchmark (HEU-MET-FAST-001) has been the primary experiment used for 235 U nuclear data validation. The papers associated with large nuclear data library releases such as ENDF/B-VII.1 and ENDF/B-VIII.0 refer to it frequently. The reasons why HEU-MET-FAST-001 has been used as the primary validation experiment for 235 U nuclear data validation will be discussed in the following section. However, as discussed among the benchmark community, the standards associated with International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluations have changed throughout time; this is subject of the OECD/NEA WPEC (Working Party on Nuclear Criticality Safety) Subgroup 8. HEU-MET-FAST-001 is an older benchmark (issued during the inaugural year of ICSBEP in 1996 with only minor revisions occurring since then) and (along with many of the other benchmarks from this era) does not meet the standards for a modern benchmark. This work explores why HEU-MET-FAST-001 is useful for 235 U nuclear data validation and discusses other alternative validation experiments.

07 ISOTOPE AND RADIATION SOURCES↗

CAAS-3S Radiation Testing for Y-12 and UPF with Godiva-IV

Goals: 1) Qualify the CAAS-3S system to a mixed-field radiation dose and dose rate, and 2) Extend the Y-12 Shielding MCNP Validation to rad-si. This paper represents the efforts of Y-12 and UPF personnel, and their interpretation of the test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IER 268 CED-3b Report

The goal of IER 268 was to collect information from the operation of the Godiva IV super-prompt critical assembly to support multi-physics modeling efforts. There were two types of systems deployed. One was a Photo-Doppler Velocimetry (PDV) system which used the reflection of laser light on the surface of the Godiva IV core. The other consisted of an MHD 240 detector with two other detectors (an MHD-241 and an Eljen EJ-325A) used for reference as the MHD-240 detector was moved. The collection is referred to as the MHD Detector in the narrative log. There were two types of Godiva operations performed to gather data. A series of super-prompt critical bursts were performed and data collected on both systems, tied to a common trigger. Separately, a series of delayed critical operations at various power levels was performed for a combination of MHD detector distances from Godiva and the presence and absence of a shield in the line of sight between Godiva and the MHD detector. This data was collected to determine the contribution of room return during the burst measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National Criticality Experiments Research Center (NCERC) - capabilities and recent measurements

The National Criticality Experiments Research Center (NCERC) located at the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS) and operated by Los Alamos National Laboratory (LANL) is home to four critical assemblies which are used to support of range of missions, including nuclear criticality safety and nuclear nonproliferation. Additionally, subcritical systems can also be assembled at NCERC. NCERC is providing critical and subcritical experiments valuable to the nuclear data community and experiments performed at NCERC are often published as benchmarks in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. This manuscript will give a broad overview of recent experiments performed at NCERC, upcoming experiments, and why integral measurements are important and useful to the nuclear data community. The four critical assemblies are GODIVA IV, FLATTOP, COMET, and PLANET. GODIVA IV is a cylindrical metal fast burst reactor, the fourth in the GODIVA series that dates back to the 1950’s. FLATTOP is an highly enriched uranium (HEU) or Pu core reflected by natural uranium. COMET and PLANET are vertical lift assemblies, where one half of the reactor can be lifted to the upper half of the reactor to create a critical system. Some recent experiments include various critical intermediate energy assemblies with lead, and subcritical measurements of plutonium reflected by copper, tungsten, and nickel. Work is also underway to make a better measurement of the critical mass of neptunium, using a neptunium sphere surrounded by nickel shells. Additionally, measurements will be performed next year with HEU shells from Rocky Flats. These HEU shells will be stacked together to make larger systems, allowing for a large range of criticality (from subcritical to delayed critical). Other upcoming measurements include an HEU critical assembly sensitive to intermediate energy neutrons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

PNNL Measurement Results for the 2018 FlatTop Criticality Nuclear Accident Dosimetry Exercise at the Nevada National Security Site (IER-253)

The Pacific Northwest National Laboratory (PNNL) participated in the FlatTop exercise IER-253 at the National Nuclear Security Site (NNSS) during the week of May 21, 2018. This report summarizes the measurements of the personal nuclear accident dosimeters (PNAD). Additionally, portable survey instrument readings and measurements of the simulated biological samples are included. The FlatTop exercise (IER-253) tested only PNADs and did not include fixed nuclear accident dosimeters (FNAD). Previous PNAD results obtained in 2016 at the Godiva-IV exercise IER-148 were summarized in PNNL Measurement Results for the 2016 Criticality Accident Dosimetry Exercise at the Nevada National Security Site IER-148 (PNNL-26497). The results clearly indicated that the previous dose conversions were a historical legacy of the Hanford Site and corresponded closer to kerma dose (or first collision dose, and not to Hp(10) dose). The technical basis for PNAD dose was based on the Godiva-IV exercise and documented in A New Dose Calculation Methodology for New PNAD and FNAD Designs at PNNL (PNNL-27023). The configuration of the PNAD was described in these two documents. The FlatTop exercise was the first time PNNL tested this new dose calculation methodology. Results were generally favorable with some results conservatively over reported that fell above the performance criteria. The reported gamma dose results fell non-conservatively low because only the default parameters obtained from the Godiva-IV exercise were used, and because the OSL gamma dosimeter has an energy dependency. The results from the simulated biological samples were also favorable, and in several cases conservatively over reported.

61 RADIATION PROTECTION AND DOSIMETRY↗

UPF and Y-12 Criticality Accident Alarm System (CAAS) Radiation Testing Report

This report documents the experimental conditions and results for the testing of the Mirion Technologies CAAS-3S Criticality Accident Alarm System (CAAS) for the Y-12 National Security Complex (Y-12) and Uranium Processing Facility (UPF). The testing was conducted at the Godiva IV Burst Reactor at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site (NNSS) during the week of January 11, 2021. The testing was conducted in accordance with 25774-QL-POA-JR00-00002-VDE-27.0, CAAS-3S Radiation Testing of Cabinet Components Test Plan. The tests subjected the CAAS-3S system to intense and short duration mixed neutron and gamma radiation fields and to high integrated radiation doses. The purpose of the test was to environmentally qualify various CAAS-3S components in a radiation environment. Successful completion of the tests was predicated on the collaborative efforts of several organizations. Sandia National Laboratory (SNL) and Lawrence Livermore National Laboratory (LLNL) provided dosimetry to estimate photon and neutron dose. Los Alamos National Laboratory (LANL) manages the NCERC facility, operated the Godiva IV reactor, and provided field support for CAAS-3S placement and communications interface for data acquisition systems supplied by Mirion Technologies. Throughout the test campaign, Y-12 and UPF personnel provided technical support in determining changes to the test schedule, as needed, interpretation of the results, and comparison between the measured dosimetry data and predicted results. Throughout the test campaign, Mirion personnel provided technical support in the operation of the CAAS-3S system itself.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation characterization summary for the WSMR fast burst reactor environment at the 6-inch location

The characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields for the White Sands Missile Range (WSMR) Fast Burst Reactor, also known as molybdenum-alloy Godiva (Molly-G) has been assessed at the 6-inch irradiation location. The neutron energy spectra, uncertainties, and common radiation metrics are presented. Code-dependent recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. The Molly-G core was designed and configured similarly to Godiva II, as an unreflected, unmoderated, cylindrical annulus of uranium-molybdenum-alloy fuel with molybdenum loading of 10%. At the 6-inch position, the axial fluence maximum is about 2.4×10 13 n/cm 2 per MJ of reactor energy; about 0.1% of the neutron fluence is below 1 keV and 96% is above 100 keV. The 1-MeV Damage-Equivalent Silicon (DES) fluence is estimated at 2.2×10 13 n/cm 2 per MJ of reactor energy. The prompt gamma-ray dose is roughly 2.5E+03 rad(Si) per MJ and the delayed gamma-ray dose is about 1.3E+03 rad(Si) per MJ.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nuclear pumped electronic transition laser studies

An experiment is proposed that should yield unambiguous absolute results on the production efficiency of rare gas excimers from fission fragments. Laser threshold efficiency is parameterized and calculations indicate that some lasers can be operated using relatively simple experimental apparatus adjacent to GODIVA. Operation of a KrF excimer laser adjacent to GODIVA appears to be possible, although the neutron pulse width is not well matched to the laser pulse duration. However, calculation indicates that KrF excimer laser output on the order of a joule may be possible.

Hughes, W. M.↗

Hands-On Experimental Training [Slides]

Training provided includes: Nuclear Criticality Safety Fundamentals, Sub-Critical "Hands On" Demonstration, Hand-Stacking and Remote Approach to Critical Using the Planet Assembly, Flattop Free-Run Demonstration, and Godiva-IV Critical Assembly Demonstration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗