Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Connection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An adaptive DC-bus stabilizer for single-phase grid-connected renewable energy source system

This paper proposes an adaptive DC-bus stabilizer for single-phase grid-connected voltage source converter (VSC) with small-scale renewable energy integration. To enhance converter's power density, the conventional active power decoupling (APD) techniques were adopted to reduce the DC capacitance by compensating the inherent second-order harmonic power ripples in the single-phase VSC. However, it would potentially make the DC voltage vulnerable to transient power ripples, which is a critical issue for the grid-connected renewable energy source (RES) system during grid faults. The proposed DC-bus stabilizer can not only compensate the second-order harmonic power ripples at normal operation, but also enhance the fault ride-through capability of the converter. The circuit topology and its corresponding control strategy are presented, and then simulation results are provided to demonstrate the feasibility and validity of the proposed DC-bus stabilizer under normal operation and grid fault condition.

Zeng, Rong↗

Novel control solutions for DoS attack delay mitigation in grid-connected and standalone inverters

This paper introduces two novel control solutions, which allow localised delay compensation for grid-connected and standalone inverters. As the prediction horizon of the existing controllers are quite small as compared to large communication delays and information unavailability due to denial-of-service (DoS) attacks, the proposed strategy offers a robust delay mitigation range using localized dynamics. Its design philosophy is leveraged via a prediction policy using the inner control loop dynamics. Based on different control objectives in grid-connected and standalone mode, the proposed solutions have been augmented into the control system accordingly. Finally, its robustness under various communication delay and DoS attacks have been tested.

Roig Greidanus, Mateo D.↗

Modular Cascaded H-Bridge Multilevel PV Inverter with Distributed MPPT for Grid-Connected Applications

This paper presents a modular cascaded H-bridge multilevel photovoltaic (PV) inverter for single- or three-phase grid-connected applications. The modular cascaded multilevel topology helps to improve the efficiency and flexibility of PV systems. To realize better utilization of PV modules and maximize the solar energy extraction, a distributed maximum power point tracking (MPPT) control scheme is applied to both single-phase and three-phase multilevel inverters, which allows the independent control of each dc-link voltage. For three-phase grid-connected applications, PV mismatches may introduce unbalanced supplied power, leading to unbalanced grid current. To solve this issue, a control scheme with modulation compensation is also proposed. An experimental three-phase 7-level cascaded H-bridge inverter has been built utilizing 9 H-bridge modules (3 modules per phase). Each H-bridge module is connected to a 185 W solar panel. Simulation and experimental results are presented to verify the feasibility of the proposed approach.

14 SOLAR ENERGY↗

Influence of Insulation Level on Electric Power Quality and Transformation Efficiency of Grid-Connected Photovoltaic Power Plants

The paper considers the influence of the insolation level on the electric power quality indicators and efficiency of a grid-tie inverter operating as part of a grid-connected photovoltaic power plant. Over the course of a year, data were recorded for Moscow on incoming solar radiation and the grid-tie inverter input and output capacity provided by a 1 kW grid-connected photovoltaic power plant. The insolation threshold values for a Solar River 1100 TL inverter are experimentally established, corresponding to both the beginning and end of stable inverter operation, as well as the required phase angle value for the electric energy supplied to the grid.

14 SOLAR ENERGY↗

Control of a Three-Phase Grid-Connected Voltage-Sourced Converter Using Long Short-Term Memory Networks

With the rise of inverter-based resources (IBRs) within the power system, the control of grid-connected converters (GCCs) has become pertinent due to the fact they interface IBRs to the grid. The conventional method of control for a GCC such as the voltage-sourced converter (VSC) is through a decoupled control loop in the synchronous reference frame. However, this model-based control method is sensitive to parameter changes causing deterioration in controller performance. Data-driven approaches such as machine learning can be utilized to design controllers that are capable of operating GCCs in various system conditions. This work explores a deep learning-based control method for a three-phase grid-connected VSC, specifically utilizing a long short-term memory (LSTM) network for robust control. Simulations of a conventional controlled VSC are conducted using Simulink to collect data for training the LSTM-based controller. The LSTM model is built and trained using the Keras and TensorFlow libraries in Python and tested in Simulink. The performance of the LSTM-based controller is evaluated under different case studies and compared to the conventional method of control. Simulation results demonstrate the effectiveness of this approach by outperforming the conventional controller and maintaining stability under different system parameter changes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Modular Multilevel Converter with Power Mismatch Control for Grid-Connected Photovoltaic Systems

A modular multilevel power converter configuration for grid connected photovoltaic (PV) systems is proposed. The converter configuration replaces the conventional bulky line frequency transformer with several high frequency transformers, potentially reducing the balance of systems cost of PV systems. The front-end converter for each port is a neutral-point diode clamped (NPC) multi-level dc-dc dual-active bridge (ML-DAB) which allows maximum power point tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is a NPC inverter. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e., 13.8 kV). The cascaded NPC (CNPC) inverters have the inherent advantage of using lower rated devices, smaller filters and low total harmonic distortion required for PV grid interconnection. The proposed converter system is modular, scalable, and serviceable with zero downtime with lower foot print and lower overall cost. A novel voltage balance control at each module based on power mismatch among N-ports, have been presented and verified in simulation. Analysis and simulation results are presented for the N-port converter. The converter performance has also been verified on a hardware prototype.

14 SOLAR ENERGY↗

Impedance-Based Prediction of Distortions Generated by Resonance in Grid-Connected Converters

Small-signal impedance-based analysis can effectively predict the frequency and damping of resonance modes in power electronic systems. However, it cannot predict the magnitude of resonance or explain resonance-generated distortions in the absence of an external disturbance at the resonance frequency. This paper presents an impedance-based theory for the prediction of the magnitude of resonance or resonance-generated distortions in grid-connected converters. It is discovered that the impedance response of a converter starts changing with the magnitude of resonance at its terminals. The changing converter impedance response may stabilize an unstable growing resonance mode beyond a certain magnitude, at which point the converter enters a limit cycle mode of sustained oscillations. The proposed theory uses large-signal impedance for the prediction of resonance-generated distortions; the large-signal impedance of an electrical equipment represents its impedance response for different magnitudes of perturbation injected at its terminals. Large-signal impedance-based prediction of resonance-generated distortions is demonstrated for a three-phase grid-connected voltage-source converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-connected heat pump water heater benefits for low-income households in the Southeastern United States

Energy efficient heat pump water heaters (HPWHs) reduce customer energy costs; grid-connected controls further increase HPWH value by enabling energy storage and shifting demand to cheaper, off-peak periods. However, a HPWH’s first cost premium can put it out of reach for low-income customers. This paper will present results of an ongoing study exploring the benefits of load shifting HPWHs for 24 low-income households, aiming to support increased product deployment in this demographic. The study uses EcoPort modules to shift HPWH load for a study sample consisting primarily of low-income adults and seniors in North Carolina. Building upon prior studies, the study’s HPWH operating schedules are designed to maximize shifted energy and minimize participant electricity costs based on local time-of-use rates. The study documents load profiles of grid-connected HPWHs in a less-studied demographic group and explores how certain groups may have particularly flexible loads due to their unique usage profiles. The results are relevant for HPWH product performance in the Southeast. The study will quantify HPWH load shifting performance during North Carolina’s hot summer, temperate shoulder, and occasionally sub-freezing winter seasons, and the study includes installations in conditioned, semi-conditioned, and unconditioned spaces. Finally, study results will also explore how controlled HPWHs can provide value to the regional grid by reducing seasonal peaks via demand response. Lessons learned include HPWH acceptance for low-income and senior users, best practices for maintaining HPWH connectivity among users without prior product experience, and strategies to leverage remote monitoring to ensure optimal operation and enhance HPWH reliability.

Urigwe, Daniela↗

High-efficiency grid-connected photovoltaic module integrated converter system with high-speed communication interfaces for small-scale distribution power generation

This paper presents a high-efficiency grid-connected photovoltaic (PV) module integrated converter (MIC) system with reduced PV current variation. The proposed PV MIC system consists of a high-efficiency step-up DC-DC converter and a single-phase full-bridge DC-AC inverter. An active-clamping flyback converter with a voltage-doubler rectifier is proposed for the step-up DC-DC converter. The proposed step-up DC-DC converter reduces the switching losses by eliminating the reverse-recovery current of the output rectifying diodes. To reduce the PV current variation introduced by the grid-connected inverter, a PV current variation reduction method is also suggested. The suggested PV current variation reduction method reduces the PV current variation without any additional components. Moreover, for centralized power control of distributed PV MIC systems, a PV power control scheme with both a central control level and a local control level is presented. The central PV power control level controls the whole power production by sending out reference power signals to each individual PV MIC system. The proposed step-up DC-DC converter achieves a high-efficiency of 97.5% at 260 W output power to generate the DC-link voltage of 350 V from the PV voltage of 36.1 V. The PV MIC system including the DC-DC converter and the DC-AC inverter achieves a high-efficiency of 95% with the PV current ripple less than 3% variation of the rated PV current. (author)

14 SOLAR ENERGY↗

Decentralized Energy Management System for Networked Microgrids in Grid-connected and Islanded Modes

This paper proposes a decentralized energy management system (EMS) for the coordinated operation of networked Microgirds (MGs) in a distribution system. In the grid-connected mode, the distribution network operator (DNO) and each MG are considered as distinct entities with individual objectives to minimize their own operation costs. It is assumed that both dispatchable and renewable energy source (RES)-based distributed generators (DGs) exist in the distribution network and the networked MGs. In order to coordinate the operation of all entities, we apply a decentralized bi-level algorithm to solve the problem with the first level to conduct negotiations among all entities and the second level to update the non-converging penalties. In the islanded mode, the objective of each MG is to maintain a reliable power supply to its customers. In order to take into account the uncertainties of DG outputs and load consumption, we formulate the problems as two-stage stochastic programs. The first stage is to determine base generation setpoints based on the forecasts and the second stage is to adjust the generation outputs based on the realized scenarios. Case studies of a distribution system with networked MGs demonstrate the effectiveness of the proposed methodology in both grid-connected and islanded modes.

Distributed Generator (DG)↗

A novel islanding detection technique for grid connected photovoltaic system

Islanding detection is the major issue in Grid Connected Photovoltaic (PV) System and still it remains a challenge for researchers to interconnect the PV system with the Grid. The algorithms which are listed in the literature are failed to identify the Islanding phenomena for the several source configuration. In this paper a novel islanding detection technique is presented to reduce the non-detection zone (NDZ) at the point of common coupling (PCC) and it can be widely used for various renewable energy system configurations. The simulations have been carried out in Matlab/Simulink for several test conditions. The simulations results are presented to confirm the effectiveness of the proposed method.

14 SOLAR ENERGY↗

Model-Based Detection Scheme for Spoofed Sensor Data in Grid-Connected Inverters

In this article, a novel method to detect spoofed sensor data (SSD) for grid-connected inverters is proposed. First, a Kalman filter is used to estimate the inverter status in the proposed method. Then, the impact of SSD on the residual between estimation and control reference is analyzed. By leveraging the standard error of residual, an adaptive cumulative sum (CUSUM) chart is developed to achieve fast SSD detection and improve robustness. In addition, the proposed SSD detection method is verified by the hardware experiment. A comparative experiment with a conventional method also demonstrates the rapidity and robustness of the proposed method. Lastly, the performance of the proposed method under different noise covariance matrices is analyzed. Comprehensive analysis shows that the proposed method meets the detection requirement in IEEE 1547 Standard.

42 ENGINEERING↗

Advancing Dynamic Modeling of Grid-Connected PV Inverter Using Bi-LSTM-Based AI Model

Power electronic converters (PECs) are widely used in modern power systems to facilitate the interconnection between various AC or DC sources and loads. Because of the extensive integration, the power system has grown into a more dynamic system in which the dynamics of the PECs must be adequately modeled. The paper presents a new bidirectional long short-term memory (Bi-LSTM) method for evaluating grid-connected inverter-based resources (IBR) dynamics. The method is tested using real hardware data from a grid -connected commercial inverter in laboratory experiments. Results show the Bi-LSTM model accurately reproduces the detailed IBR model's dynamics, even when the internal structure is unknown and parameters are unknown, preventing the disclosure of the manufacturer's confidential data.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

Flicker Mitigation for a Grid-Connected Tidal and River Power Generator Using the BESS

In the grid-connected tidal and river power generation, the water turbulence and the grid condition can induce the fluctuating output power. This power fluctuation may cause a power quality issue such as flicker, or voltage fluctuations, during the continuous operation. Hence, it is important to assess flicker emission and to mitigate flicker in order to solve this power quality issue. This paper proposes a Battery Energy Storage System (BESS)installed between the power converters of the tidal and river power system in order to mitigate flickers in different grid conditions. The BESS smooths the active power fluctuations and reduces flicker even from the weak grid with the low impedance angle in the distribution network. The feasibility of the proposed BESS system has been tested using a simplified simulation model with interconnected inverters developed in the validated simulation tool of PSCAD/EMTDC, and the obtained results from the case studies are presented.

16 TIDAL AND WAVE POWER↗

Adaptive Internal Model Based Current Control with Embedded Active Damping of a Three-Phase Grid-Connected Inverter with LCL Filter for PV Application

This paper presents an internal model based controller with embedded active damping for a three-phase grid-connected inverter with LCL filter. A strategy to control the grid current based on the internal model principle is presented in this paper. It is known that a third-order LCL filter apart from providing better attenuation also poses the problem of initiating unwanted resonance oscillations especially during transients. To address this problem, an active damping strategy based on virtual resistance emulation on the grid side filter is implemented. Also, to ensure effective active damping, an online parameter update strategy is implemented for the filter parameters. The proposed method provides better attenuation to oscillation damping and achieves good tracking performance without adversely affecting the bandwidth. The architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.

grid-connected inverter↗

Advanced Distributed Wind Turbine Controls Series: Part 3-Wind Energy in Grid-Connected Deployments – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years the technical ability and requirement for distributed wind turbines to provide grid support services beyond maximum energy production has increased. Ancillary services leveraged through advance controls of a wind turbine support grid reliability and resilience. One ancillary service that is significant to a grid-connected wind turbine deployment is fault ride through (FRT) in response to the voltage and frequency events in the power system. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, the wind turbine's FRT capabilities to support stable grid operation. We establish that the wind turbine models exceed FRT performance requirements stipulated in IEEE 1547-2018, regarding interconnection and interoperability of distributed energy resources. Utilizing a standalone CART2 (600 kW) wind turbine connected to the NREL's Flatirons Campus grid, we study voltage and frequency FRT utilizing various test cases. One of the test cases under study is a Category III voltage fault defined in IEEE 1547-2018 and derived from CA Rule 21. Some distributed wind turbines were unable to connect to the grid following the Rule 21 enforcement in California. Even if this is not a general requirement elsewhere, the grid codes might evolve in this direction. This study illustrates how a distributed wind turbine can provide some of these FRT services and enable a pathway toward a higher contribution of renewable energy in a distribution grid.

17 WIND ENERGY↗

Value Gradient Learning Approach in Power and Frequency Regulation of Grid-Connected Synchronverters

In this paper, a neural network adaptive critic design (ACD) method based on value gradient learning (VGL) is used to optimally control a grid-connected synchronverter. The main drawback of the traditional synchronverters is their infeasibility to face non-inductive grids. To be able to implement a synchronverter technique in any impedance angle, a neural network-based adaptive controller is used. The advantage of adaptive dynamic programing is its ability to adjust itself when it faces changes and uncertainties in the power system. The proposed VGL consists of two subnetworks: the critic network and the action network. The action network is trained during the operation, and the critic network can be pretrained offline or can be simultaneously trained with the action network. To compare the effectiveness of the traditional synchronverter to the VGL-based synchronverter, the simulation results are provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technical, economic, and load-following capabilities assessment of grid-connected geothermal and geothermal-solar hybrid systems

The technical and economic performance as well as the load-following capabilities of grid-connected geothermal hybrid systems were assessed in this work. The analyzed geothermal hybrid configuration is composed of a binary geothermal plant integrated with a concentrating solar-thermal system and underground thermal energy storage (UTES) through a primary heat exchanger. Physics-based models for the hybrid system for plant generation capacities of 1, 25, and 50 MW were developed from validated models for each subsystem. Also, an economic model was developed that accounts for different hybrid system capabilities, solar field sizes, and thermal storage duration. The advantage of the geothermal hybrid system was assessed by comparing the performance with the baseline benchmark geothermal plant with a similar configuration and generation capacity. It was found that hybridizing geothermal plants with concentrating solar and thermal energy storage not only improves the thermal efficiency by up to 8 percentage points when additional heat from the solar-UTES loop rises the evaporator temperatures from 70 to 125 °C, but also enhances the load-following capability for the geothermal plant, which can meet a typical residential load profile with a power rate of change 0.25 kW/s with an absolute error under 13 kW for a 1 MW plant. Other benefits of hybridization include resource preservation and a potential LCOE reduction of up to 56% for a 50 MW geothermal hybrid plant having a 50% solar share, a 1.4 solar multiple, and 24-h storage capacity. The results presented in this work demonstrate that hybridizing geothermal systems transforms them into a flexible and cost-effective solution for addressing the dynamic requirements of modern electric grids.

15 GEOTHERMAL ENERGY↗