Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Statistical Estimation of EV Driver Charging Behavior and Influential Factors

INL received data collected via telematics from battery electric vehicles (BEVs), and these vehicles were owned by retail customers who had entered into a telematics user agreement. The goal of analyzing these data was to develop mathematical models to characterize how different sets of BEV drivers use charging infrastructure at home and away from home (i.e., public charging) and quantify how various factors influence BEV drivers’ decision to charge and use available infrastructure. The data used in this analysis are unique because they provide real world BEV driving and charging behavior at the individual driving and parking event level. In this study we seek to leverage this data to quantify BEV charging and driving metrics to help inform models that predict quantities like the specific times when loads are imposed on the electrical grid due to BEV charging. Most models that have been developed to predict electrical grid load due to BEV charging, use simulations of BEV driving events and rely on assumptions such as every vehicle charges every night. Using a statistical modelling framework, we seek to investigate BEV charging behavior and quantitatively assess these common assumptions of BEV charging behavior.

33 - ADVANCED PROPULSION SYSTEMS↗

Hybrid-RL-MPC4CLR (Hybird-Reinforcement-Learning-Model-Predictive-Control-for-Reserve-Policy-Assisted-Critical-Load-Restoration-in-Distribution-Grids)

Hybrid-RL-MPC4CLR was developed as a hybrid controller for active distribution grid critical load restoration, combining deep reinforcement learning (RL) and model predictive control (MPC) aiming at maximizing total restored load following an extreme event. The RL determines a policy for quantifying operating reserve requirements, thereby hedging against uncertainty, while the MPC models grid operations incorporating the RL policy actions (i.e., reserve requirements), renewable (wind and solar) power predictions, and load demand forecasts. The developers formulated the reserve requirement determination problem as a sequential decision-making problem based on the Markov Decision Process (MDP) and design an RL learning environment based on the OpenAI Gym framework and MPC simulation. The RL agent reward and MPC objective function aim to maximize and monotonically increase total restored load and minimize load shedding and renewable power curtailment. The software is developed using various software packages in Python. The MPC's optimal power flow (OPF) model is implemented using the Pyomo package, the RL simulation environment is implemented using the MPC simulation with various scenarios of renewable energy and load demand profiles and power outage beginning times, based on the OpenAI Gym framework. The RL agent training is performed using the RLlib Ray package. The RL algorithm is trained offline using historical forecasts of renewable generation and load demand profiles. Simulation analysis and performance tests are conducted using a modified IEEE 13-bus distribution test feeder containing wind turbine, photovoltaic, microturbine, and battery.

Eseye, Abinet Tesfaye↗

TranAir applications to predicting transonic aircraft/store loads

During a recent AIWS wind tunnel test for the F-18, the AIWS grid loads were in substantial disagreement with carriage loads measured on the opposite pylon at M = 0.95. Carriage loads indicated that the AIWS configuration might impact the fuel tank mounted on the inboard pylon during jettison at M = 0.95, while CTS data indicated this to be a safe jettison condition. An attempt was made to determine the correct loads for this condition. On the basis of PAN AIR and TranAir calculations, it appears that the carriage loads are correct, while the CTS measured grid data may be subject to sting-fuel tank interference effects at transonic speeds.

Cenko, A.↗

Grid scheduling divisible loads from two sources

To date closed form solutions for optimal finish time and job allocation are largely obtained only for network topologies with a single load originating (root) processor. However in large-scale data intensive problems with geographically distributed resources, load is generated from multiple sources. This paper introduces a new divisible load scheduling strategy for single level tree networks with two load originating processors. Solutions for an optimal allocation of fractions of load to nodes in single level tree networks are obtained via linear programming. A unique scheduling strategy that allows one to obtain closed form solutions for the optimal finish time and load allocation for each processor in the network is also presented. The tradeoff between linear programming and closed form solutions in terms of underlying assumptions is examined. Finally, a performance evaluation of a two source homogeneous single level tree network with concurrent communication strategy is presented.

97 MATHEMATICS AND COMPUTING↗

A Decision Support Framework for Grid-Aware Electric Bus Charge Scheduling

While there are many advantages to electric public transit vehicles, they also pose new challenges for fleet operators. One key challenge is defining a charge scheduling policy that minimizes operating costs and power grid disruptions while maintaining schedule adherence. An uncoordinated policy could result in some buses running out of charge before completing their trip, while a grid agnostic policy might incur higher energy costs or cause an adverse impact on the grid’s distribution system. We present a grid aware decision-theoretic framework for electric bus charge scheduling that accounts for energy price, grid load, and bus status. The framework connects environmental models for traffic (SUMO) and the electric grid (GridLAB-D) to a planner, which evaluates bus charging decisions with regard to their long-term effect on grid reliability and cost. The framework has been evaluated on a simulation of Richland, WA’s bus and grid network, and compared to greedy methods.

EV, machine leaning, EV-Grid, Transportation, Grid↗

Optimal Discrete Net-Load Balancing in Smart Grids with High PV Penetration

Mitigating supply-demand mismatch is essential for smooth power grid operation. Traditionally, load curtailment techniques such as demand response have been used for this purpose. However, these cannot be the only component of a net-load balancing framework for smart grids with high PV penetration. These grids sometimes exhibit supply surplus, causing overvoltages. Currently, these are mitigated using voltage manipulation techniques such as Volt-Var Optimizations, which are computationally expensive, thereby increasing the complexity of grid operations. Taking advantage of recent technological developments that enable rapid selective connection of PV modules of an installation to the grid, we develop a unified net-load balancing framework that performs both load and solar curtailment. We demonstrate that when the available curtailment values are discrete, this problem is NP-hard and we develop bounded approximation algorithms. Our algorithms produce fast solutions, given the tight timing constraints required for grid operation, while ensuring that practical constraints such as fairness, network capacity limits, and so forth are satisfied. We also develop an online algorithm that performs net-load balancing using only data available for the current interval. Using both theoretical analysis and practical evaluations, we show that our net-load balancing algorithms provide solutions that are close to optimal in a small amount of time.

14 SOLAR ENERGY↗

Applying Utility's Advanced Grid Technologies to Improve Resiliency of a Critical Load

The US DOE Office of Electricity's Energy Storage Program's joint R&D work with the Cordova Electric Cooperative (CEC) has deployed several advanced grid technologies that are providing benefits today to Cordova Alaska's electricity users. Advanced grid technologies deployed through DoE co-funded R&D include a 1MW Battery Energy Storage System (BESS), and enhanced monitoring including Phasor Measurement Units (PMU's) to help better understand the operational impacts of the added BESS. This paper will highlight key accomplishments to-date in deploying and using advanced grid technologies, and then outline the next phase of work that will use these technologies to implement an operating scheme to reconfigure the utility's distribution system and utility resources including BESS to provide emergency back-up power to a critical load: the Cordova Community Medical Center (CCMC). This paper will include additional insights on the use of utility resources to support critical loads via case study examples by the National Rural Electric Cooperative Assoc. (NRECA).

BESS↗

Characterizing electrical panel capacity, breaker space, and loads in U.S. single-family homes

Electrical panels distribute electricity to appliances, equipment, and other building loads and maintain safety by preventing overloads of branch circuits, feeders, and utility service wires connecting homes to the grid. Load calculations in the National Electrical Code (NEC) determine the capacity of installed electrical panels in the United States, which are rated in amps (A). Circuit breakers within electrical panels affect the magnitude and number of loads that panels can serve. In home retrofits and renovations, existing electrical panels may not accommodate new electrical loads, either due to insufficient electrical capacity or a lack of available breaker spaces. Homes with these panel constraints may need to replace existing panels with new panels that have greater capacity and breaker space.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Tied Photovoltaic Power System

A grid-tied photovoltaic (PV) power system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility. Operating costs of a PV power system are low compared to conventional power technologies. This method can displace the highest-cost electricity during times of peak demand in most climatic regions, and thus reduce grid loading. Net metering is often used, in which independent power producers such as PV power systems are connected to the utility grid via the customers main service panels and meters. When the PV power system is generating more power than required at that location, the excess power is provided to the utility grid. The customer pays the net of the power purchased when the on-site power demand is greater than the onsite power production, and the excess power is returned to the utility grid. Power generated by the PV system reduces utility demand, and the surplus power aids the community. Modern PV panels are readily available, reliable, efficient, and economical, with a life expectancy of at least 25 years. Modern electronics have been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy equal to the modern PV panels. The grid-tied PV power system was successfully designed and developed, and this served to validate the basic principles developed, and the theoretical work that was performed. Grid-tied PV power systems are reliable, maintenance- free, long-life power systems, and are of significant value to NASA and the community. Of particular value are the analytical tools and capabilities that have been successfully developed. Performance predictions can be made confidently for grid-tied PV systems of various scales. The work was done under the NASA Hybrid Power Management (HPM) Program, which is the integration of diverse power devices in an optimal configuration for space and terrestrial applications.

Eichenberg, Dennis J.↗

K-anonymity applied to the energy grid of things distributed energy resource management system

Smart grid infrastructure relies on information exchange between multiple actors in order to ensure system reliability. These actors include but are not limited to smart loads, grid control, and energy management technologies. As information exchange between these actors is susceptible to cyber-attacks, security and privacy issues are indispensable to ensure a reliable and stable grid. This position paper proposes a privacypreserving, trust-augmented secure scheme for a smart grid implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Privacy-preserving Information Security for the Energy Grid of Things

Smart grid infrastructure relies on information exchange between multiple actors in order to ensure system reliability. These actors include but are not limited to smart loads, grid control, and energy management technologies. Further, as information exchange between these actors is susceptible to cyber-attacks, security and privacy issues are indispensable to ensure a reliable and stable grid. This position paper proposes a privacy-preserving, trust-augmented secure scheme for a smart grid implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spatial Impacts of Electric Vehicle Charging on Power Grid Stability: A Downtown Atlanta Case Study

The rapid increase in electric vehicle (EV) charging demand poses a potential risk to power grid stability, particularly as the spatial distribution of this demand remains underexplored. Existing research often focuses on technical optimization models while overlooking the geographic and human dynamics that affect energy consumption. This study addresses this gap by incorporating mobility data to estimate both building energy use and EV charging demand while also considering geographic factors for a better understanding of grid load. Using agent-based simulations and the Open-Source Distribution System Simulator, the study evaluates the effect of various EV penetration scenarios on grid voltage and unbalance. The results show that, although voltage remains within acceptable limits at lower EV penetration rates, significant voltage drop and unbalance occur as EV penetration exceeds 40%, particularly in residential areas with high charging demand. This study offers a framework for integrating spatial analysis and mobility data in power network simulations, providing insights for future EV infrastructure planning.

Pan, Melrose [ORNL] (ORCID:000000031627448X)↗

Optimal net-load balancing in smart grids with high PV penetration

Mitigating mismatches in supply demand curve is critical for smooth power grid operation. Traditionally, load curtailment techniques such as Demand Response (DR) have been used for this purpose. However, smart grids with high PV penetration sometimes exhibit supply surplus causing over-voltages. Thus, load curtailment techniques cannot be the only component of a net-load balancing framework. Supply curtailment techniques such as Volt-Var Optimizations are complex and computationally expensive. This increases the complexity of net-load balancing systems used by the grid operator and limits their scalability. Recently, new technologies have been developed that enable the rapid and selective connection of PV modules of an installation to the grid. Taking advantage of these advancements, we develop a unified optimal net-load balancing framework which performs both load and solar curtailment. We show that when the available curtailment values are discrete, this problem is NP-hard and develop bounded approximation algorithms for minimizing the curtailment cost. Our algorithms produce fast solutions, given the tight timing constraints required for grid operation. We also incorporate the notion of fairness to ensure that curtailment is evenly distributed among all the nodes. Finally, we develop an online algorithm which performs net-load balancing using only data available for the current interval. Using both theoretical analysis and practical evaluations, we show that our net-load balancing algorithms provide solutions which are close to optimal in a small amount of time.

14 SOLAR ENERGY↗

Community Energy: Analysis of Hydrogen Distributed Energy Systems with Photovoltaics for Load Leveling and Vehicle Refueling

Energy storage could complement PV electricity generation at the community level. Because PV generation is intermittent, strategies must be implemented to integrate it into the electricity system. Hydrogen and fuel cell technologies offer possible PV integration strategies, including the community-level approaches analyzed in this report: (1) using hydrogen production, storage, and reconversion to electricity to level PV generation and grid loads (reconversion scenario); (2) using hydrogen production and storage to capture peak PV generation and refuel hydrogen fuel cell electric vehicles (FCEVs) (hydrogen fueling scenario); and (3) a comparison scenario using a battery system to store electricity for EV nighttime charging (electric charging scenario).

08 HYDROGEN↗

An MILP framework for optimizing demand response operation of air separation units

Renewable electricity generation and consumer demand are desynchronized in time, posing a challenge for grid operators. Industrial demand response (DR), has emerged as a strong candidate for mitigating demand variability. In this paper, we demonstrate the application of DR to an air separation unit (ASU), a chemical process that consumes significant amounts of electricity. We develop a novel optimal production scheduling framework that accounts for day-ahead electricity prices to modulate the grid load presented by the plant. Our framework accounts for the dynamics of the plant using a novel dynamic modeling framework. Further, we present a new decomposition scheme that allows us to solve the corresponding optimization problem in a matter of minutes. Extensive simulation results show significant reductions in operating costs (that benefit the plant) and reductions in peak power demand (which benefits the grid).

24 POWER TRANSMISSION AND DISTRIBUTION↗

3D-FE Modeling of 316 SS under Strain-Controlled Fatigue Loading and CFD Simulation of PWR Surge Line

In financial year 2017, we are focusing on developing a mechanistic fatigue model of surge line pipes for pressurized water reactors (PWRs). To that end, we plan to perform the following tasks: (1) conduct stress- and strain-controlled fatigue testing of surge-line base metal such as 316 stainless steel (SS) under constant, variable, and random fatigue loading, (2) develop cyclic plasticity material models of 316 SS, (3) develop one-dimensional (1D) analytical or closed-form model to validate the material models and to understand the mechanics associated with 316 SS cyclic hardening and/or softening, (4) develop three-dimensional (3D) finite element (FE) models with implementation of evolutionary cyclic plasticity, and (5) develop computational fluid dynamics (CFD) model for thermal stratification, thermal-mechanical stress, and fatigue of example reactor components, such as a PWR surge line under plant heat-up, cool-down, and normal operation with/without grid-load-following. This semi-annual progress report presents the work completed on the above tasks for a 316 SS laboratory-scale specimen subjected to strain-controlled cyclic loading with constant, variable, and random amplitude. This is the first time that the accurate 3D-FE modeling of the specimen for its entire fatigue life, including the hardening and softening behavior, has been achieved. We anticipate that this work will pave the way for the development of a fully mechanistic-computer model that can be used for fatigue evaluation of safety-critical metallic components, which are traditionally evaluated by heavy reliance on time-consuming and costly test-based approaches. This basic research will not only help the nuclear reactor industry for fatigue evaluation of reactor components in a cost effective and less time-consuming way, but will also help other safety-related industries, such as aerospace, which is heavily dependent on test-based approaches, where a single full-scale fatigue test can cost millions of dollars and require years of effort to conduct. Toward our goal of demonstration of fully mechanistic fatigue evaluation of reactor components, we also started work on developing a component-level computer model of reactor components, such as 316 SS surge line pipe. This requires developing a thermal-mechanical stress analysis model of the reactor surge line, which, in turn, requires time-dependent temperature and stratification information along the boundary of the pipe. Toward that goal, CFD models of surge lines are being developed. In this report, we also present some preliminary results showing the temperature conditions along the surge line wall under reactor heat-up, cool-down, and steady-state power operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improvement of Transmission Line Ampacity Utilization by Weather-Based Dynamic Line Rating

Most of the existing overhead transmission lines (TLs) are assigned a static rating by considering the conservative environmental conditions (e.g., high ambient temperature and low wind speed). Such a conservative approach often results in underutilization of line ampacity because the worst conditions prevail only for a short period of time during the year. Dynamic line rating (DLR) utilizes local meteorological conditions and grid loadings to adaptively compute additional line ampacity headroom that may be available due to favorable local environmental conditions. This paper details Idaho National Laboratory-developed weather-based DLR, which utilizes a state-of-the-art general line ampacity state solver for real-time computation of thermal ratings of TLs. Performance of the proposed DLR solution is demonstrated in existing TL segments at AltaLink, Canada, and the potential benefits of the proposed DLR for enhanced transmission ampacity utilization are quantified. Moreover, we investigated a hypothetical case for emulating the impact of an additional wind plant near the test grid. Furthermore, the results for the given system and data configurations demonstrated that real-time ratings were above the seasonal static ratings for at least 76.6% of the time, with a mean increase of 22% over the static rating, thereby demonstrating huge potential for improvement on ampacity utilization.

17 WIND ENERGY↗

Recent Advances in Scalable, High‐Mass Loaded Electrodes for Grid‐Scale Energy Storage

Abstract The increasing electrification of daily life as well as the intermittent characteristic of renewable energy sources require viable solutions for grid‐scale energy storage. Critical considerations for grid storage applications are electrode mass loading and electrode thickness as these features govern battery pack energy density, an important factor in determining manufacturing costs. For this reason, there is increased interest in finding new ways of creating electrodes with high mass loading. In this review, various high‐mass loading fabrication approaches are considered for positive electrode materials used in batteries. The benchmark used for high mass loading is above 20 mg cm −2 , which is higher than the practical limit of conventional tape‐cast electrodes. Several different electrode approaches are described including templating, laser patterning, direct ink writing, and electrodeposition. A variety of materials are covered with the most prominent being LiFe(PO 4 ) (LFP), LiCoO 2 (LCO), and MnO 2 . In research to date, scalable electrochemical performance has been achieved with mass loadings over 100 mg cm −2 . Areal capacities as high as 14.7 mAh cm −2 at 1.82 mA cm −2 have been achieved in non‐aqueous electrolytes and 9.8 mAh cm −2 at 10 mA cm −2 in aqueous electrolytes. These results establish that the mass loading of electrodes can be scaled up without compromising their electrochemical properties.

White, Makena [Department of Materials Science and↗