Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ground source heat pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Application of thermal energy storage with electrified heating and cooling in a cold climate

Ground source heat pumps (GSHPs) have been shown to be an effective means of decarbonizing building heating and cooling, but the operation of these systems at scale presents challenges to sites and the grid due to increases in peak demand. Here, in this study, we investigate how the use of Thermal Energy Storage (TES), in the form of stratified water storage, could reduce the peak daily demand associated with GSHP systems and thus improve their cost effectiveness. This system was compared to a Combined Heat and Power (CHP) plant, to investigate the potential cost and emissions impacts of electrification on large energy users transitioning from high efficiency fossil fuel equipment. This study builds on previous research by using a significant campus area, and investigating the various impacts of an electrified system versus a state of the art fossil fuel system. An established method of TRNSYS modeling is used for the heat pumps and borehole heat exchangers (BHEs), along with the TES. The GSHP system with TES is modeled to follow industry standards and sized to provide an optimal balance of capital and operating costs. Costs were investigated for a unique large energy user rate structure, as well as for a more common generalized rate structure. The results show that the addition of TES to the GSHP system could reduce operating costs by 4.5%, but still incurs a 5.64% cost increase from the baseline CHP system. It is also shown, however, that a tactical integration of heat pumps into the CHP system is the most cost effective solution, only increasing the operating costs by 4.71%. Likewise, the impacts of different rate structures are highlighted, with the TES only resulting in 0.75% cost savings under the generalized utility rate. Furthermore, it is shown that thermal storage has great potential for demand reduction, with the addition of storage incurring a decrease of 7–22% in annual peak demand kW, dependent on the rate structure.

25 ENERGY STORAGE↗

A dynamic 2D Borehole Thermal Energy Storage (BTES) model for enhanced computational efficiency

Progressing toward a future increasingly reliant on renewable energy sources, the development of effective, durable energy storage solutions becomes essential to balance supply and demand fluctuations. Borehole Thermal Energy Storage (BTES) is a long-duration thermal energy storage technology that captures excess heat generated from renewable energy sources and stores it underground for later use, enabling the efficient utilization of sustainable energy. This approach is particularly valuable in district energy networks when integrated with Ground Source Heat Pumps (GSHP) to provide stable heating and cooling. However, traditional three-dimensional (3D) numerical models of BTES systems demand extensive computational resources, limiting their practicality for real-time and large-scale applications. This study introduces a novel two-dimensional (2D) modeling approach that reduces computational costs while maintaining high accuracy. By employing a radial ring-based discretization method, the model simulates heat injection, retention, and retrieval dynamics over seasonal cycles. A new thermal-mass weighted-average temperature parameter is introduced to evaluate the performance of BTES systems. Model validation against FEFLOW simulations demonstrates a 17-fold improvement in computational speed compared to traditional Computational Fluid Dynamics (CFD) models while achieving a mean absolute percentage error (MAPE) of 2 % during charging and 4 % during discharging. Additionally, a trade-off analysis between computational efficiency and accuracy is conducted, ensuring the model's applicability for real-world scenarios. The findings of this research contribute to the development of computationally efficient BTES models, facilitating better optimization, control, and integration into renewable energy systems. This work provides a foundation for further studies in techno-economic analysis, multi-year performance evaluation, and real-time operational strategies for BTES applications, supporting a more sustainable energy future.

2D modeling↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GHEDesigner [SWR-23-33]

GHEDesigner is a Python package for designing ground heat exchangers (GHE) used with ground source heat pump (GSHP) systems.

Mitchell, Matt↗

Multicriteria screening evaluation of geothermal resources on mine lands for direct use heating

Abstract Direct use of geothermal energy is the oldest and most versatile form of utilizing geothermal energy. In the last decade, this utilization has significantly increased, especially with the installation of geothermal (ground-source) heat pumps. Many current and inactive mine land sites across the U.S. could be redeveloped with clean energy technologies such as direct use geothermal, which would revitalize former mining communities, help with reducing greenhouse gas emissions, and accelerate the transition to a clean energy economy. We present a multicriteria screening framework to evaluate various aspects of direct-use geothermal projects on mine lands. The criteria are divided into three categories: (1) technical potential, (2) demand and benefits, and (3) regulatory and permitting. We demonstrate the framework using publicly available data on a national scale (continental U.S.). Then, using an example of abandoned coal mines in Illinois and focusing on resource potential, we illustrate how this evaluation can be applied at the state or more local scales when a region’s characteristics drive spatial variability estimates. The strength of this approach is the ability to combine seemingly disparate parameters and inputs from numerous sources. The framework is very flexible—additional criteria can be easily incorporated and weights modified if input data support them. Vice versa, the framework can also help identify additional data needed for evaluating those criteria. The multicriteria screening evaluation methodology provides a framework for identifying potential candidates for detailed site evaluation and characterization.

15 GEOTHERMAL ENERGY↗

Assessing Low-Temperature Geothermal Play Types: Relevant Data and Play Fairway Analysis Methods

The U.S. Department of Energy (DOE) Geothermal Technologies Office (GTO) is supporting the Geothermal Heating and Cooling Geospatial Datasets and Analysis project conducted by the National Renewable Energy Laboratory (NREL) as part of a broader effort to demonstrate the multi-faceted value of integrating geothermal power and geothermal heating and cooling (GHC) technologies into national decarbonization plans and community energy plans. Currently, there is a need to establish baseline low-temperature geothermal resource datasets and evaluate methods for deploying these technologies to provide the basis for supporting private sector investment. This project is focused on collecting baseline datasets, updating conceptual models, and creating Play Fairway Analysis (PFA) workflows for low-temperature (<150 degrees Celsius) geothermal resources of different geothermal play types (i.e., sedimentary basin, orogenic belts, and radiogenic geothermal play types) that could be used for geothermal heating and cooling (GHC), combined heat and power (CHP), and other geothermal direct uses (GDU) applications. Low-temperature geothermal resources are defined as reservoirs - natural or engineered - with temperatures <150 degrees Celsius. While the focus in the NREL effort is on GHC, resources at the upper end of this temperature range can also be used for small-scale power generation. This project does not include Ground Source Heat Pumps (GSHPs) technologies because they can be effectively developed almost anywhere. Low-temperature geothermal resources have not been studied as extensively as higher- to medium-temperature geothermal resources, but there is recent interest in improving understanding of these types of resources with an uptick of interest in geothermal technologies for decarbonizing heating and cooling systems. In addition, Enhanced Geothermal Systems (EGS) and other emerging technologies for exploiting petrothermal resources have opened the possibility of utilizing deep sedimentary basin systems, where porous media provide permeability and high temperatures can be reached at great depths. This project takes the approach of classifying low- temperature geothermal resources by geothermal play type (GPT). We defined and characterized three major classes of low-temperature GPT: sedimentary basins, orogenic systems, and radiogenic systems. We develop methodologies for evaluating and analyzing the potential for these resources building off the PFA approach to de-risking geothermal exploration and characterization. The proposed PFA approach for low-temperature geothermal resources includes: 1) identifying relevant data (e.g., datasets such bottom-hole temperatures from oil and gas wells, heat flow data, Quaternary faults and stress field data, geophysical data, etc.); 2) grouping and weighting of relevant datasets into PFA criteria (e.g., geological, risk, and economic criteria); 3) uncertainty quantification; 4) developing favorability or common risk maps for low-temperature geothermal resources to identify potential locations for more focused data collection; and 5) estimating electric power generation and heating potential at those locations using the GeoRePORT Resource Size Assessment Tool (RSAT). This project should facilitate future deployment of GHC, CHP, and GDU by providing data, tools, and a workflow applicable to low-temperature geothermal resources. Increased deployment of GHC and GDU will help achieve national and local decarbonization goals.

15 GEOTHERMAL ENERGY↗

Zero-Emissions Roadmap for Oakland County

This document outlines a strategic pathway for Oakland County, Michigan to achieve zero emissions by 2050 under the Clean Energy to Communities (C2C) Program. The report encompasses analyses and high-level modeling to guide Oakland County in its emission reduction goals. Key methods include establishing an emissions inventory baseline with ongoing evaluation of future projects’ emissions impacts. Core elements include decommissioning old infrastructure, enhancing energy efficiency, deploying hybrid and ground-source heat pumps, and transitioning to electric fleets. It is proposed to structure the planning process into 5-year strategic plans to make the decarbonization process manageable. The document also emphasizes the need for reassessment of goals and periodic updates to remain adaptive to technological advancements and funding considerations. A matrixed approach for evaluating projects by cost and emissions savings is suggested to optimize decision-making given finite resources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Klickitat Valley Health Central Utility Plant Modernization

This project replaced legacy heating and cooling equipment at Klickitat Valley Health (KVH), a rural hospital in Goldendale, Washington. Work included constructing a new chiller building, installing modern hydronic piping systems, replacing the main Emergency Department air handler (Air Handlining Unit (AHU-1)), upgrading electrical systems, and converting the Emergency Department wing from electric reheat to hydronic heating and cooling. Commissioning, testing, adjusting, and balancing were completed under this grant. These upgrades improve energy efficiency, operational resilience, and system reliability while preparing the campus for future electrification and renewable energy integration. They also support growth in healthcare services for a rural population. The project directly reduces energy costs and provides a foundation for future decarbonization measures, including a FEMA-funded microgrid and a large-scale ground source heat pump (GSHP) project. These follow-on initiatives would not have been possible without the hydronic backbone built through this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Study on Charging and Discharging Performance of a Dual-Purpose Underground Thermal Battery

A dual-purpose underground thermal battery (DPUTB) was proposed for Grid-interactive Efficient Buildings. It integrates underground thermal energy storage with a shallow-buried ground heat exchanger (less than 6 m deep). The charging and discharging performance of a lab-scale DPUTB were experimentally investigated. The test results show that the lab-scale (1:125 in volume) DPUTB can provide 34 W cooling continuously for 3.7 h with a supply water temperature below 14°C. The water temperature rise of the inner tank was slowed down during the discharging process due to the phase change of the phase change material (PCM). Thermal storage capacity was increased by 156% using the PCM that only occupied 19% volume of the inner tank. The heat lost from the inner tank was recovered in the outer tank and led to the efficiency improvement of a ground source heat pump.

Wang, Lingshi↗

Geothermal Heat Pump Case Study: Autumn Gardens Apartment Complex

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Autumn Gardens Apartment Complex and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study↗

Geothermal Heat Pump Case Study: The Century Center

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on The Century Center and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study↗

Geothermal Heat Pump Case Study: College of Southern Idaho

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on College of Southern Idaho and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study↗

Geothermal Heat Pump Case Study: Dallas-Fort Worth U.S. 287 Bridge

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Dallas-Fort Worth U.S. 287 Bridge and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study↗

Geothermal Heat Pump Case Study: Greensburg, Kansas, City Hall

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Greensburg, Kansas, City Hall and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study↗

Geothermal Heat Pump Case Study: Marine Corps Logistics Base-Albany

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Marine Corps Logistics Base-Albany and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study↗

Cost and Performance Analysis for Five Existing Geothermal Heat Pump-Based District Energy Systems in the United States

District energy systems supplied by geothermal heat pumps (GHPs) have been deployed across the United States for both heating and cooling end uses. To better understand their performance and potential, the geothermal research team at the National Renewable Energy Laboratory analyzed cost and performance of five existing GHP-based district energy systems in the United States. The five systems selected are Ball State University in Indiana, Colorado Mesa University in Colorado, Miami University in Ohio, West Union in Iowa, and Whisper Valley in Texas. The necessary information, including district size, operation period, GHP performance, and costs, was collected through literature review and interviews. The survey results indicated the five systems studied consist of geothermal borehole field(s) and ground loop(s) connected to central loop. While the GHPs were in central plants at Ball State University and Miami University, the central loops at Colorado Mesa University, West Wood, and Whisper Valley were connected through service lines to individual heat pumps in each building. Our analysis indicates the systems have been operating reliably and cost-effectively and contributed to a reduction in carbon emissions.

15 GEOTHERMAL ENERGY↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗