Search NASA⌕ Search

SEARCH · Search NASA

Results for “HACKER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Protecting Smart Buildings with STIG

This is a submission for the 2022 Intern Poster Session. The abstract of the poster is: Smart buildings are getting more common, and so are hackers that target them. The physical systems in our businesses and homes are now vulnerable to cyber attacks. Using STIG, an INL program that turns cybersecurity data into graphs, buildings can be better protected.

99 GENERAL AND MISCELLANEOUS↗

Generating SBoMs Utilizing Structured Threat Information Expression JSON bundles

With cyber-attacks on the rise, information is one of the first lines of defense. Now more than ever, security experts and developers need efficient ways to know if their software may be outdated or vulnerable to emerging threats. By generating a Software Bill of Material based on STIX2/JSON bundles, security experts and developers can ensure that they know where to find what can go wrong with their systems before the hackers do. As part of the Infrastructure Expression project, Idaho National Laboratory (INL) is currently working on ways that can aid in the development of efficient SBOMs using Structured Threat Information Expression (STIX). Doing so can provide an efficient first line of defense for detection and monitoring that can be easily used by cyber personnel from beginners to highly skilled experts.

97 MATHEMATICS AND COMPUTING↗

Neural Network Based Intrusion Detection System for Critical Infrastructures

Resiliency and security in control systems such as SCADA and Nuclear plant’s in today’s world of hackers and malware are a relevant concern. Computer systems used within critical infrastructures to control physical functions are not immune to the threat of cyber attacks and may be potentially vulnerable. Tailoring an intrusion detection system to the specifics of critical infrastructures can significantly improve the security of such systems. The IDS-NNM – Intrusion Detection System using Neural Network based Modeling, is presented in this paper. The main contributions of this work are: 1) the use and analyses of real network data (data recorded from an existing critical infrastructure); 2) the development of a specific window based feature extraction technique; 3) the construction of training dataset using randomly generated intrusion vectors; 4) the use of a combination of two neural network learning algorithms – the Error-Back Propagation and Levenberg-Marquardt, for normal behavior modeling. The presented algorithm was evaluated on previously unseen network data. The IDS-NNM algorithm proved to be capable of capturing all intrusion attempts presented in the network communication while not generating any false alerts.

97 MATHEMATICS AND COMPUTING↗

Machine Learning in High Energy Physics Community White Paper

Machine learning is an important applied research area in particle physics, beginning with applications to high-level physics analysis in the 1990s and 2000s, followed by an explosion of applications in particle and event identification and reconstruction in the 2010s. In this document we discuss promising future research and development areas in machine learning in particle physics with a roadmap for their implementation, software and hardware resource requirements, collaborative initiatives with the data science community, academia and industry, and training the particle physics community in data science. The main objective of the document is to connect and motivate these areas of research and development with the physics drivers of the High-Luminosity Large Hadron Collider and future neutrino experiments and identify the resource needs for their implementation. Additionally we identify areas where collaboration with external communities will be of great benefit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving Wind Predictions in the Marine Atmospheric Boundary Layer through Parameter Estimation in a Single-Column Model

A current barrier to greater deployment of offshore wind turbines is the poor quality of numerical weather prediction model wind and turbulence forecasts over open ocean. The bulk of development for atmospheric boundary layer (ABL) parameterization schemes has focused on land, partly due to a scarcity of observations over ocean. The 100-m FINO1 tower in the North Sea is one of the few sources worldwide of atmospheric profile observations from the sea surface to turbine hub height. These observations are crucial to developing a better understanding and modeling of physical processes in the marine ABL. In this study, we use the WRF single column model (SCM), coupled with an ensemble Kalman filter from the Data Assimilation Research Testbed (DART), to create 100-member ensembles at the FINO1 location. The goal of this study is to determine the extent to which model parameter estimation can improve offshore wind forecasts.

17 WIND ENERGY↗

Volatility and lifetime against OH heterogeneous reaction of ambient isoprene-epoxydiols-derived secondary organic aerosol (IEPOX-SOA)

Abstract. Isoprene-epoxydiols-derived secondary organic aerosol (IEPOX-SOA) can contribute substantially to organic aerosol (OA) concentrations in forested areas under low NO conditions, hence significantly influencing the regional and global OA budgets, accounting, for example, for 16–36 % of the submicron OA in the southeastern United States (SE US) summer. Particle evaporation measurements from a thermodenuder show that the volatility of ambient IEPOX-SOA is lower than that of bulk OA and also much lower than that of known monomer IEPOX-SOA tracer species, indicating that IEPOX-SOA likely exists mostly as oligomers in the aerosol phase. The OH aging process of ambient IEPOX-SOA was investigated with an oxidation flow reactor (OFR). New IEPOX-SOA formation in the reactor was negligible, as the OFR does not accelerate processes such as aerosol uptake and reactions that do not scale with OH. Simulation results indicate that adding ∼ 100 µg m−3 of pure H2SO4 to the ambient air allows IEPOX-SOA to be efficiently formed in the reactor. The heterogeneous reaction rate coefficient of ambient IEPOX-SOA with OH radical (kOH) was estimated as 4.0 ± 2.0 × 10−13 cm3 molec−1 s−1, which is equivalent to more than a 2-week lifetime. A similar kOH was found for measurements of OH oxidation of ambient Amazon forest air in an OFR. At higher OH exposures in the reactor (> 1 × 1012 molec cm−3 s), the mass loss of IEPOX-SOA due to heterogeneous reaction was mainly due to revolatilization of fragmented reaction products. We report, for the first time, OH reactive uptake coefficients (γOH = 0.59 ± 0.33 in SE US and γOH = 0.68 ± 0.38 in Amazon) for SOA under ambient conditions. A relative humidity dependence of kOH and γOH was observed, consistent with surface-area-limited OH uptake. No decrease of kOH was observed as OH concentrations increased. These observations of physicochemical properties of IEPOX-SOA can help to constrain OA impact on air quality and climate.

Hu, Weiwei↗

Reply to Comment on Polymorphism in the 1:1 Charge-Transfer Complex DBTTF-TCNQ and Its Effects on Optical and Electronic Properties

In the article “Polymorphism in the 1:1 Charge-Transfer Complex DBTTF-TCNQ and Its Effects on Optical and Electronic Properties”,1 we reported on two polymorphs of the charge-transfer complex dibenzotetrathiafulvalene–7,7,8,8-tetracyanoquinodimethane (DBTTF-TCNQ). The X-ray photoelectron spectroscopy (XPS) measurements performed on each crystal type confirmed the donor:acceptor (D:A) stoichiometry for the previously known α-polymorph and identified it as the same (1:1) for the newly discovered β-polymorph. Selected area electron diffraction confirmed the uniqueness of the crystal structure of each polymorph, though the thin nature of the β-crystals precluded the complete determination of the crystal structure. Nonetheless, a combination of spectroscopic methods, including optical absorption, XPS, infrared (IR) spectroscopy, and density functional theory (DFT) allowed us to propose a crystal structure for the β-polymorph. The structural differences between the two polymorphs manifested themselves in a differing value of the degree of charge transfer between the donor and acceptor species, ρ, as determined via shifts in the agυ4 mode measured using Raman spectroscopy,2 and differing electrical properties. Additionally, when the crystals were used to fabricate field-effect transistors, the α-polymorph was found to be ambipolar with higher electron mobility than a hole mobility, while the β-polymorph was also found to be ambipolar, but with a higher hole mobility than electron mobility.

36 MATERIALS SCIENCE↗

Assessment of attenuation correction for myocardial PET imaging using combined PET/MRI

Objective: To evaluate the frequency of artifacts in MR-based attenuation correction (AC) maps and their impact on the quantitative accuracy of PET-based flow and metabolism measurements in a cohort of consecutive heart failure patients undergoing combined PET/MR imaging. Methods: Myocardial viability studies were performed in 20 patients following a dual-tracer protocol involving the assessment of myocardial perfusion ({sup 13}N-NH{sub 3}: 813 ± 86 MBq) and metabolism ({sup 18}F-FDG: 335 ± 38 MBq). All acquisitions were performed using a fully-integrated PET/MR system, with standard DIXON-attenuation correction (DIXON-AC) mapping for each PET scan. All AC maps were examined for spatial misalignment with the emission data, total lung volume, susceptibility artifacts, and tissue inversion (TI). Misalignment and susceptibility artifacts were corrected using rigid co-registration and retrospective filling of the susceptibility-induced gaps, respectively. The effects of the AC artifacts were evaluated by relative difference measures and perceived changes in clinical interpretations. Results: Average respiratory misalignment of (7 ± 4) mm of the PET-emission data and the AC maps was observed in 18 (90%) patients. Substantial changes in the lung volumes of the AC maps were observed in the test–retest analysis (ratio: 1.0 ± 0.2, range: 0.8-1.4). Susceptibility artifacts were observed in 10 (50%) patients, while six (30%) patients had TI artifacts. Average differences of 14 ± 10% were observed for PET images reconstructed with the artifactual AC maps. The combined artifact effects caused false-positive findings in three (15%) patients. Conclusion: Standard DIXON-AC maps must be examined carefully for artifacts and misalignment effects prior to AC correction of cardiac PET/MRI studies in order to avoid misinterpretation of biased perfusion and metabolism readings from the PET data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Complete revascularization determined by myocardial perfusion imaging could improve the outcomes of patients with stable coronary artery disease, compared with incomplete revascularization and no revascularization

Objectives: To compare the outcomes among patients treated by complete coronary revascularization (CCR) or incomplete coronary revascularization (ICR) and no coronary revascularization (NCR) by myocardial perfusion imaging (MPI), as well as to evaluate the impact of severity of ischemia on patients with coronary artery disease (CAD) by different therapy strategies. Background: Using myocardial ischemia severity determined by MPI guiding treatment strategies for CAD patients still lacks strong clinical evidences. Methods: Consecutive patients (N = 286) underwent clinical stress-rest SPECT MPI and were retrospectively followed-up. For assessment of outcome of treatment, all patients were classified into three groups (CCR, ICR, and NCR), and further divided into two subgroups as mild ischemia (< 10% ischemic myocardium) and moderate-severe ischemia (≥ 10% ischemic myocardium). All-cause death was defined as the primary endpoint, and the composite of deaths, nonfatal myocardial infarction, and repeat revascularization (MACE) as the secondary endpoint. Results: Two-hundred eighty-six patients were followed-up for 46 ± 21 months. Thirty deaths and 65 MACEs were recorded. Patients treated by revascularization had significantly lower MACE (P < .001) but not mortality (P = .158) than patients treated by NCR. Outcomes of CCR related to mortality rate were greater than ICR and NCR (death: P = .019, MACE: P < .001). In patients with moderate-severe ischemia, CCR showed improved outcomes than ICR and NCR (death: P = .034; and MACE: P < .001). In patients with mild ischemia, the outcomes of CCR, ICR, and NCR had no significant difference (P > .05). Multivariate regression Cox analysis revealed that summed difference score [death: HR 1.09 (1.03, 1.15), P = .004] was an independent risk factor and CCR was an independent negative predictor [death: HR 0.31 (0.12, 0.81), P = .017; MACE: HR 0.30 (0.16, 0.57), P < .001]. Conclusions: Outcomes of patients treated by CCR were most likely more promising in comparison with treatment of ICR and NCR, especially when patients had over 10% ischemic myocardium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alkaline Ethanol Oxidation Reaction on Carbon Supported Ternary PdNiBi Nanocatalyst using Modified Instant Reduction Synthesis Method

Direct ethanol fuel cells (DEFC) still lack active and efficient electrocatalysts for the alkaline ethanol oxidation reaction (EOR). In this work, a new instant reduction synthesis method was developed to prepare carbon supported ternary PdNiBi nanocatalysts with improved EOR activity. Synthesized catalysts were characterized with a variety of structural and compositional analysis techniques in order to correlate their morphology and surface chemistry with electrochemical performance. The modified instant reduction synthesis results in well-dispersed, spherical Pd85Ni10Bi5 nanoparticles on Vulcan XC72R support (Pd85Ni10Bi5/C(II-III)), with sizes ranging from 3.7 +/- 0.8 to 4.7 +/- 0.7 nm. On the other hand, the common instant reduction synthesis method leads to significantly agglomerated nanoparticles (Pd85Ni10Bi5/C-(I)). EOR activity and stability of these three different carbon supported PdNiBi anode catalysts with a nominal atomic ratio of 85:10:5 were probed via cyclic voltammetry and chronoamperometry using the rotating disk electrode method. Pd85Ni10Bi5/C-(II) showed the highest electrocatalytic activity (150 mA.cm(-2); 2678 mA.mg(-1)) with low onset potential (0.207 V) for EOR in alkaline medium, as compared to a commercial Pd/C and to the other synthesized ternary nanocatalysts Pd85Ni10Bi5/C-(I) and Pd85Ni10Bi5/C-(III). This new synthesis approach provides a new avenue to developing efficient, carbon supported ternary nanocatalysts for future energy conversion devices. The modified instant reduction method for synthesis of ternary Pd85Ni10Bi5/C-(II) nanocatalyst using Vulcan XC72R as carbon support initiates an agglomeration reduction, provides low average particle size, and enables enhanced activity for the alkaline ethanol oxidation reaction (EOR) compared to the common instant reduction method and to a commercial Pd/C catalyst.

Alkaline direct ethanol fuel cell↗

A generative machine learning model for designing metal hydrides applied to hydrogen storage

Developing new metal hydrides is a critical step toward efficient hydrogen storage in carbon-neutral energy systems. However, existing materials databases, such as the Materials Project, contain a limited number of well-characterized hydrides, which constrains the discovery of optimal candidates. This work presents a framework that integrates causal discovery with a lightweight generative machine learning model to generate novel metal hydride candidates that may not exist in current databases. Using a dataset of 450 samples (270 training, 90 validation, and 90 testing), the model generates 1000 candidates. After ranking and filtering, six previously unreported chemical formulas and crystal structures are identified, four of which are validated by density functional theory simulations and show strong potential for future experimental investigation. Overall, the proposed framework provides a scalable and time-efficient approach for expanding hydrogen storage datasets and accelerating materials discovery.

generative model↗

Restricted Field IMRT Dramatically Enhances IMRT Planning for Mesothelioma

Purpose: To improve the target coverage and normal tissue sparing of intensity-modulated radiotherapy (IMRT) for mesothelioma after extrapleural pneumonectomy. Methods and Materials: Thirteen plans from patients previously treated with IMRT for mesothelioma were replanned using a restricted field technique. This technique was novel in two ways. It limited the entrance beams to 200{sup o} around the target and three to four beams per case had their field apertures restricted down to the level of the heart or liver to further limit the contralateral lung dose. New constraints were added that included a mean lung dose of <9.5 Gy and volume receiving {>=}5 Gy of <55%. Results: In all cases, the planning target volume coverage was excellent, with an average of 97% coverage of the planning target volume by the target dose. No change was seen in the target coverage with the new technique. The heart, kidneys, and esophagus were all kept under tolerance in all cases. The average mean lung dose, volume receiving {>=}20 Gy, and volume receiving {>=}5 Gy with the new technique was 6.6 Gy, 3.0%, and 50.8%, respectively, compared with 13.8 Gy, 15%, and 90% with the previous technique (p < 0.0001 for all three comparisons). The maximal value for any case in the cohort was 8.0 Gy, 7.3%, and 57.5% for the mean lung dose, volume receiving {>=}20 Gy, and volume receiving {>=}5 Gy, respectively. Conclusion: Restricted field IMRT provides an improved method to deliver IMRT to a complex target after extrapleural pneumonectomy. An upcoming Phase I trial will provide validation of these results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Irradiation of the Postoperative Resection Cavity for Brain Metastasis: A Frameless Linear Accelerator-Based Case Series and Review of the Technique

Purpose: Whole-brain radiation therapy (WBRT) is the standard of care after resection of a brain metastasis. However, concern regarding possible neurocognitive effects and the lack of survival benefit with this approach has led to the use of stereotactic radiosurgery (SRS) to the resection cavity in place of WBRT. We report our initial experience using an image-guided linear accelerator-based frameless stereotactic system and review the technical issues in applying this technique. Methods and Materials: We retrospectively reviewed the setup accuracy, treatment outcome, and patterns of failure of the first 18 consecutive cases treated at Brigham and Women's Hospital. The target volume was the resection cavity without a margin excluding the surgical track. Results: The median number of brain metastases per patient was 1 (range, 1-3). The median planning target volume was 3.49 mL. The median prescribed dose was 18 Gy (range, 15-18 Gy) with normalization ranging from 68% to 85%. In all cases, 99% of the planning target volume was covered by the prescribed dose. The median conformity index was 1.6 (range, 1.41-1.92). The SRS was delivered with submillimeter accuracy. At a median follow-up of 12.7 months, local control was achieved in 16/18 cavities treated. True local recurrence occurred in 2 patients. No marginal failures occurred. Distant recurrence occurred in 6/17 patients. Median time to any failure was 7.4 months. No Grade 3 or higher toxicity was recorded. A long interval between initial cancer diagnosis and the development of brain metastasis was the only factor that trended toward a significant association with the absence of recurrence (local or distant) (log-rank p = 0.097). Conclusions: Frameless stereotactic irradiation of the resection cavity after surgery for a brain metastasis is a safe and accurate technique that offers durable local control and defers the use of WBRT in select patients. This technique should be tested in larger prospective studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Orally Active, Aminothiol Radioprotector-Free of Nausea and Hypotension Side Effects at Its Highest Radioprotective Doses

Purpose: A new aminothiol, PrC-210, was tested for orally conferred radioprotection (rats, mice; 9.0 Gy whole-body, which was otherwise lethal to 100% of the animals) and presence of the debilitating side effects (nausea/vomiting, hypotension/fainting) that restrict use of the current aminothiol, amifostine (Ethyol, WR-2721). Methods and Materials: PrC-210 in water was administered to rats and mice at times before irradiation, and percent-survival was recorded for 60 days. Subcutaneous (SC) amifostine (positive control) or SC PrC-210 was administered to ferrets (Mustela putorius furo) and retching/emesis responses were recorded. Intraperitoneal amifostine (positive control) or PrC-210 was administered to arterial cannulated rats to score drug-induced hypotension. Results: Oral PrC-210 conferred 100% survival in rat and mouse models against an otherwise 100% lethal whole-body radiation dose (9.0 Gy). Oral PrC-210, administered by gavage 30-90 min before irradiation, conferred a broad window of radioprotection. The comparison of PrC-210 and amifostine side effects was striking because there was no retching or emesis in 10 ferrets treated with PrC-210 and no induced hypotension in arterial cannulated rats treated with PrC-210. The tested PrC-210 doses were the ferret and rat equivalent doses of the 0.5 maximum tolerated dose (MTD) PrC-210 dose in mice. The human equivalent of this mouse 0.5 MTD PrC-210 dose would likely be the highest PrC-210 dose used in humans. By comparison, the mouse 0.5 MTD amifostine dose, 400 {mu}g/g body weight (equivalent to the human amifostine dose of 910 mg/m{sup 2}), when tested at equivalent ferret and rat doses in the above models produced 100% retching/vomiting in ferrets and 100% incidence of significant, progressive hypotension in rats. Conclusions: The PrC-210 aminothiol, with no detectable nausea/vomiting or hypotension side effects in these preclinical models, is a logical candidate for human drug development to use in healthy humans in a wide variety of radioprotection settings, including medical radiation, space travel, and nuclear accidents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 2 Study of Erlotinib Combined With Adjuvant Chemoradiation and Chemotherapy in Patients With Resectable Pancreatic Cancer

Purpose: Long-term survival rates for patients with resected pancreatic ductal adenocarcinoma (PDAC) have stagnated at 20% for more than a decade, demonstrating the need to develop novel adjuvant therapies. Gemcitabine-erlotinib therapy has demonstrated a survival benefit for patients with metastatic PDAC. Here we report the first phase 2 study of erlotinib in combination with adjuvant chemoradiation and chemotherapy for resected PDAC. Methods and Materials: Forty-eight patients with resected PDAC received adjuvant erlotinib (100 mg daily) and capecitabine (800 mg/m{sup 2} twice daily Monday-Friday) concurrently with intensity modulated radiation therapy (IMRT), 50.4 Gy over 28 fractions followed by 4 cycles of gemcitabine (1000 mg/m{sup 2} on days 1, 8, and 15 every 28 days) and erlotinib (100 mg daily). The primary endpoint was recurrence-free survival (RFS). Results: The median follow-up time was 18.2 months (interquartile range, 13.8-27.1). Lymph nodes were positive in 85% of patients, and margins were positive in 17%. The median RFS was 15.6 months (95% confidence interval [CI], 13.4-17.9), and the median overall survival (OS) was 24.4 months (95% CI, 18.9-29.7). Multivariate analysis with adjustment for known prognostic factors showed that tumor diameter >3 cm was predictive for inferior RFS (hazard ratio, 4.01; P=.001) and OS (HR, 4.98; P=.02), and the development of dermatitis was associated with improved RFS (HR, 0.27; P=.009). During CRT and post-CRT chemotherapy, the rates of grade 3/4 toxicity were 31%/2% and 35%/8%, respectively. Conclusion: Erlotinib can be safely administered with adjuvant IMRT-based CRT and chemotherapy. The efficacy of this regimen appears comparable to that of existing adjuvant regimens. Radiation Therapy Oncology Group 0848 will ultimately determine whether erlotinib produces a survival benefit in patients with resected pancreatic cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Baseline Metabolic Tumor Volume and Total Lesion Glycolysis Are Associated With Survival Outcomes in Patients With Locally Advanced Pancreatic Cancer Receiving Stereotactic Body Radiation Therapy

Purpose: Although previous studies have demonstrated the prognostic value of positron emission tomography (PET) parameters in other malignancies, the role of PET in pancreatic cancer has yet to be well established. We analyzed the prognostic utility of PET for patients with locally advanced pancreatic cancer (LAPC) undergoing fractionated stereotactic body radiation therapy (SBRT). Materials and Methods: Thirty-two patients with LAPC in a prospective clinical trial received up to 3 doses of gemcitabine, followed by 33 Gy in 5 fractions of 6.6 Gy, using SBRT. All patients received a baseline PET scan prior to SBRT (pre-SBRT PET). Metabolic tumor volume (MTV), total lesion glycolysis (TLG), and maximum and peak standardized uptake values (SUV{sub max} and SUV{sub peak}) on pre-SBRT PET scans were calculated using custom-designed software. Disease was measured at a threshold based on the liver SUV, using the equation Liver{sub mean} + [2 × Liver{sub sd}]. Median values of PET parameters were used as cutoffs when assessing their prognostic potential through Cox regression analyses. Results: Of the 32 patients, the majority were male (n=19, 59%), 65 years or older (n=21, 66%), and had tumors located in the pancreatic head (n=27, 84%). Twenty-seven patients (84%) received induction gemcitabine prior to SBRT. Median overall survival for the entire cohort was 18.8 months (95% confidence interval [CI], 15.7-22.0). An MTV of 26.8 cm{sup 3} or greater (hazard ratio [HR] 4.46, 95% CI 1.64-5.88, P<.003) and TLG of 70.9 or greater (HR 3.08, 95% CI 1.18-8.02, P<.021) on pre-SBRT PET scan were associated with inferior overall survival on univariate analysis. Both pre-SBRT MTV (HR 5.13, 95% CI 1.19-22.21, P=.029) and TLG (HR 3.34, 95% CI 1.07-10.48, P=.038) remained independently associated with overall survival in separate multivariate analyses. Conclusions: Pre-SBRT MTV and TLG are potential predictive factors for overall survival in patients with LAPC and may assist in tailoring therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lymphocyte-Sparing Effect of Stereotactic Body Radiation Therapy in Patients With Unresectable Pancreatic Cancer

Purpose: Radiation-induced lymphopenia (RIL) is associated with inferior survival in patients with glioblastoma, lung cancer, and pancreatic cancer. We asked whether stereotactic body radiation therapy (SBRT) decreases severity of RIL compared to conventional chemoradiation therapy (CRT) in locally advanced pancreatic cancer (LAPC). Methods and Materials: Serial total lymphocyte counts (TLCs) from patients enrolled in a prospective trial of SBRT for LAPC were compared to TLCs from an existing database of LAPC patients undergoing definitive CRT. SBRT patients received 33 Gy (6.6 Gy × 5 fractions). CRT patients received a median dose of 50.4 Gy (1.8 Gy × 28 fractions) with concurrent 5-fluorouracil (77%) or gemcitabine (23%) therapy. Univariate and multivariate analyses (MVA) were used to identify associations between clinical factors and post-treatment TLC and between TLC and survival. Results: Thirty-two patients received SBRT and 101 received CRT. Median planning target volume (PTV) was smaller in SBRT (88.7 cm{sup 3}) than in CRT (344.6 cm{sup 3}; P<.001); median tumor diameter was larger for SBRT (4.6 cm) than for CRT (3.6 cm; P=.01). SBRT and CRT groups had similar median baseline TLCs. One month after starting radiation, 71.7% of CRT patients had severe lymphopenia (ie, TLC <500 cells/mm{sup 3} vs 13.8% of SBRT patients; P<.001). At 2 months, 46.0% of CRT patients remained severely lymphopenic compared with 13.6% of SBRT patients (P=.007). MVA demonstrated that treatment technique and baseline TLCs were significantly associated with post-treatment TLC at 1 but not 2 months after treatment. Higher post-treatment TLC was associated with improved survival regardless of treatment technique (hazard ratio [HR] for death: 2.059; 95% confidence interval: 1.310-3.237; P=.002). Conclusions: SBRT is associated with significantly less severe RIL than CRT at 1 month in LAPC, suggesting that radiation technique affects RIL and supporting previous modeling studies. Given the association of severe RIL with survival in LAPC, further study of the effect of radiation technique on immune status is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recent advancements in high performance polymer electrolyte fuel cell electrode fabrication – Novel materials and manufacturing processes

The global effort to introduce polymer electrolyte fuel cells for clean and renewable energy to the market is increasing the demand for high performance, robust and affordable membrane electrode assemblies (MEAs). There is not yet a standard method for large scale production of MEAs, or the methods employed are generally unsatisfactory in terms of quality and performance. A large number of published data of newly developed catalyst and electrolyte materials, claim to improve the state of the art, but are often not fully comparable due to different experimental studies and experimental designs. This article summarizes the trends in material developments and emerging MEA-manufacturing techniques. The materials and techniques are systematically compared in terms of cell performance and scalability. Current and future scientific challenges are identified and analysed based on published findings over the past five years. Finally, the results of the cited papers have been quantitatively compared to each other and to the internal benchmarks used in each cited work to provide a complete picture of the state of the art in PEFC MEA manufacturing.

25 ENERGY STORAGE↗