Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Signal processing methodologies for an acoustic fetal heart rate monitor

Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively 'trained' in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a series of patients. Comparative data provides favorable indications of the feasibility of the acoustic monitor for clinical use.

Pretlow, Robert A., III↗

Keeping a Beat on the Heart

Feel the relief of a patient suffering from heart arrhythmia, who is able to return home while having her heart monitored by health professionals 24 hours a day, without the fear that she will miss an important indicator and suffer a fatal heart attack - using technology originally developed to conduct experiments on the Space Shuttle. Approximately 400,000 Americans die every year from sudden heart attacks . Medical research revealed that patterns of electrical activity in the heart can act as predictors of these lethal cardiac events known as arrhythmias. Fortunately, certain arrhythmias such as ventricular fibrillation (loss of regular heartbeat and subsequent loss of function) and ventricular tachycardia (rapid heartbeats), can be detected and appropriately treated. Today, patients at moderate risk of arrhythmias can benefit from technology that would permit long- term continuous monitoring of electrical cardiac rhythms outside the hospital environment in the comfort of their own homes. Medical telemetry systems, also known as telemedicine, are evolving rapidly as wireless communication technology advances, evidenced by the commercial products and research prototypes for remote health monitoring that have appeared in recent years. Wireless systems allow patients to move freely in their home and work environment while being monitored remotely by health care professionals.

Liszka, Kathy J.↗

Bluetooth(Registered Trademark) Heart Rate Monitors for Spaceflight

Heart rate monitoring is required during exercise for crewmembers aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data is required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth® heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health on board ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) was worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_RHM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the two data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. REULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6%error), followed by CS4 (3.3%error), CS3 (6.4%error), and CS2 (9.2%error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to get the best quality data. CS2 will be used in an ISS Bluetooth validation study, because it simultaneously transmits Magnetic Pulse which is integrated with existing exercise hardware on ISS. The simultaneous data streams allow for beat to beat comparison between the current ISS standard and CS2.Upon Bluetooth(Registered Trademark) validation aboard ISS, down select of a new BT_HRM for operational use will be made.

Buxton, Roxanne E.↗

Bluetooth Heart Rate Monitors For Spaceflight

Heart rate monitoring is required for crewmembers during exercise aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data are required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health aboard the ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) were worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_HRM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the 2 data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. RESULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6% error), followed by CS4 (3.3% error), CS3 (6.4% error), and CS2 (9.2% error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, but unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to obtain the best quality data. CS2 will be used in an ISS Bluetooth validation study, because it simultaneously transmits magnetic pulse that is integrated with existing exercise hardware on ISS. The simultaneous data streams allow for beat-to-beat comparison between the current ISS standard and CS2. Upon Bluetooth validation aboard ISS, the research team will down select a new BT_HRM for operational use.

Buxton, R. E.↗

Alterations in left ventricular diastolic function in conscious dogs with pacing-induced heart failure

We investigated in conscious dogs (a) the effects of heart failure induced by chronic rapid ventricular pacing on the sequence of development of left ventricular (LV) diastolic versus systolic dysfunction and (b) whether the changes were load dependent or secondary to alterations in structure. LV systolic and diastolic dysfunction were evident within 24 h after initiation of pacing and occurred in parallel over 3 wk. LV systolic function was reduced at 3 wk, i.e., peak LV dP/dt fell by -1,327 +/- 105 mmHg/s and ejection fraction by -22 +/- 2%. LV diastolic dysfunction also progressed over 3 wk of pacing, i.e., tau increased by +14.0 +/- 2.8 ms and the myocardial stiffness constant by +6.5 +/- 1.4, whereas LV chamber stiffness did not change. These alterations were associated with increases in LV end-systolic (+28.6 +/- 5.7 g/cm2) and LV end-diastolic stresses (+40.4 +/- 5.3 g/cm2). When stresses and heart rate were matched at the same levels in the control and failure states, the increases in tau and myocardial stiffness were no longer observed, whereas LV systolic function remained depressed. There were no increases in connective tissue content in heart failure. Thus, pacing-induced heart failure in conscious dogs is characterized by major alterations in diastolic function which are reversible with normalization of increased loading condition.

NASA Discipline Cardiopulmonary↗

Leptin modulates gene expression in the heart, cardiomyocytes and the adipose tissue thus mitigating LPS-induced damage

Highlights: • LPS enhanced expression of the leptin gene in mouse tissues and cardiomyocytes. • Leptin downregulated pro-inflammatory genes in vivo and in cardiomyocytes after LPS treatment. • Leptin upregulated expression of antioxidant genes in vivo and in cardiomyocytes after LPS treatment. • Leptin reduced ROS levels in cardiomyocytes after LPS treatment. • Leptin acts to counteract LPS-induced damage in the heart and cardiomyocytes by modulating gene expression. • Anti-inflammatory effects of leptin in transgenic aMUPA mice overexpressing leptin surpassed that of wild type mice. Leptin is an adipokine of pleiotropic effects linked to energy metabolism, satiety, the immune response, and cardioprotection. We have recently shown that leptin causally conferred resistance to myocardial infarction-induced damage in transgenic αMUPA mice overexpressing leptin compared to their wild type (WT) ancestral mice FVB/N. Prompted by these findings, we have investigated here if leptin can counteract the inflammatory response triggered after LPS administration in tissues in vivo and in cardiomyocytes in culture. The results have shown that LPS upregulated in vivo and in vitro all genes examined here, both pro-inflammatory and antioxidant, as well as the leptin gene. Pretreating mice with leptin neutralizing antibodies further upregulated the expression of TNFα and IL-1β in the adipose tissue of both mouse types, and in the αMUPA heart. The antibodies also increased the levels of serum markers for cell toxicity in both mouse types. These results indicate that under LPS, leptin actually reduced the levels of these inflammatory-related parameters. In addition, pretreatment with leptin antibodies reduced the levels of HIF-1α and VEGF mRNAs in the heart, indicating that under LPS leptin increased the levels of these mRNAs. In cardiomyocytes, pretreatment with exogenous leptin prior to LPS reduced the expression of both pro-inflammatory genes, enhanced the expression of the antioxidant genes HO-1, SOD2 and HIF-1α, and lowered ROS staining. In addition, results obtained with leptin antibodies and the SMLA leptin antagonist indicated that endogenous and exogenous leptin can inhibit leptin gene expression. Together, these findings have indicated that under LPS, leptin concomitantly downregulated pro-inflammatory genes, upregulated antioxidant genes, and lowered ROS levels. These results suggest that leptin can counteract inflammation in the heart and adipose tissue by modulating gene expression.

60 APPLIED LIFE SCIENCES↗

Distribution of plutonium and radium in the human heart

Since 1968, the United States Transuranium and Uranium Registries (USTUR) has studied the biokinetics and tissue dosimetry of uranium and transuranium elements in nuclear workers. As part of the USTUR collaboration with the Million Person Study of Low-Dose Health Effects, radiation dose to different parts of the human heart is being estimated for workers with documented intakes of 239 Pu or 226 Ra. The study may be expanded for workers with intakes of 238 U and other radionuclides. The distribution of radionuclides, expressed in terms of concentration (Bq per kg of tissue) serves as an important parameter for estimating radiation dose. Based on available organs from workers who donated their bodies or tissues for research, nine undissected hearts were selected: seven from USTUR registrants with plutonium exposure (males) and two individuals with radium intakes (female and male). For the plutonium workers, estimated 239 Pu systemic deposition ranged from <74 Bq to 1765 Bq. Estimated 226 Ra ‘initial systemic intakes’ were 10.1 MBq and 14.8 kBq for the female patient and male worker, respectively. Organ dissection was based on a heart model published by Borrego et al (2019 J. Radiol. Prot. 39 950–65). This model includes nine cardiac substructures: aorta, left main coronary artery, left atrium, left anterior descending artery, left circumflex artery, left ventricle, right atrium, right coronary artery, and right ventricle. In addition, heart valves, fat attached to epicardium, fluids, and a coronary bypass graft were collected resulting in 111 samples that are currently undergoing radiochemical analyses and mass-spectrometric measurements. The 239 Pu and 226 Ra evaluations are not completed. The results of this study are intended to support radiation worker health studies by improving associated dosimetric and epidemiological models.

USTUR↗

A dual-input nonlinear system analysis of autonomic modulation of heart rate

Linear analyses of fluctuations in heart rate and other hemodynamic variables have been used to elucidate cardiovascular regulatory mechanisms. The role of nonlinear contributions to fluctuations in hemodynamic variables has not been fully explored. This paper presents a nonlinear system analysis of the effect of fluctuations in instantaneous lung volume (ILV) and arterial blood pressure (ABP) on heart rate (HR) fluctuations. To successfully employ a nonlinear analysis based on the Laguerre expansion technique (LET), we introduce an efficient procedure for broadening the spectral content of the ILV and ABP inputs to the model by adding white noise. Results from computer simulations demonstrate the effectiveness of broadening the spectral band of input signals to obtain consistent and stable kernel estimates with the use of the LET. Without broadening the band of the ILV and ABP inputs, the LET did not provide stable kernel estimates. Moreover, we extend the LET to the case of multiple inputs in order to accommodate the analysis of the combined effect of ILV and ABP effect on heart rate. Analyzes of data based on the second-order Volterra-Wiener model reveal an important contribution of the second-order kernels to the description of the effect of lung volume and arterial blood pressure on heart rate. Furthermore, physiological effects of the autonomic blocking agents propranolol and atropine on changes in the first- and second-order kernels are also discussed.

NASA Discipline Regulatory Physiology↗

Augmented baroreflex heart rate gain after moderate-intensity, dynamic exercise

The occurrence of a sustained vasodilation and hypotension after acute, dynamic exercise suggests that exercise may alter arterial baroreflex mechanisms. Therefore, we assessed systemic hemodynamics, baroreflex regulation of heart rate, and cardiac vagal tone after 60 min of cycling at 60% peak oxygen consumption in 12 healthy, untrained men and women (ages 21-28 yr). We derived sigmoidal carotid-cardiac baroreflex relations by measurement of R-R interval changes induced by ramped, stepwise, R-wave-triggered changes in external neck pressure from 40 to -65 mmHg. We estimated tonic cardiac vagal control with power spectral analysis of R-R interval variability in the respiratory frequency band (0.2-0.3 Hz) during frequency- and tidal volume-controlled breathing. Both mean arterial pressure and total peripheral resistance were reduced postexercise [pressure: from 86 +/- 2 (mean +/- SE) to 81 +/- 2 mmHg; resistance: from 23 +/- 2 to 16 +/- 1 units; both P < 0.05]. Cardiac output was increased postexercise (from 3.9 +/- 0.3 to 5.5 +/- 0.5 l/min, P < 0.05). Both slope and range of the carotid-cardiac baroreflex relation were increased postexercise (slope: from 4.7 +/- 0.7 to 6.1 +/- 0.9 ms/mmHg; range: from 186 +/- 23 to 238 +/- 30 ms, P < 0.05). Respiratory R-R interval variability (cardiac vagal tone) was not changed at any time after exercise, whereas heart rate and plasma norepinephrine levels were elevated. Thus moderate-intensity, dynamic exercise increases heart rate and cardiac output, reduces peripheral vascular resistance, and augments baroreflex responsiveness. Our data suggest that augmented baroreflex heart rate gain restrains rather than contributes to postexercise hypotension, which appears to be mediated predominately by vasodilation.

NASA Discipline Cardiopulmonary↗

Augmented catecholamine uptake by the heart during hemorrhage in the conscious dog

Changes in arterial and coronary sinus concentrations of norepinephrine (NE) and epinephrine (E) in response to hemorrhage were examined in conscious dogs. Hemorrhage (45 +/- 3.2 ml/kg) decreased mean arterial pressure by 47 +/- 6%, left ventricular (LV) dP/dt by 38 +/- 6%, and mean left circumflex coronary blood flow by 47 +/- 6%, while heart rate increased by 44 +/- 13%. Increases in concentrations of arterial NE (5,050 +/- 1,080 from 190 +/- 20 pg/ml) and E (12,700 +/- 3,280 from 110 +/- 20 pg/ml) were far greater than increases in coronary sinus NE (1,700 +/- 780 from 270 +/- 50 pg/ml) and E (4,300 +/- 2,590 from 90 +/- 10 pg/ml). Net release of NE from the heart at rest was converted to a fractional extraction of 66 +/- 9% after hemorrhage. Fractional extraction of E increased from 16 +/- 6% at rest to 73 +/- 8% after hemorrhage. In cardiac-denervated dogs, hemorrhage (46 +/- 2.8 ml/kg) decreased mean arterial pressure by 39 +/- 15%, LV dP/dt by 36 +/- 10%, and mean left circumflex coronary blood flow by 36 +/- 13%, while heart rate increased by 24 +/- 10%. Hemorrhage increased arterial NE (1,740 +/- 150 from 210 +/- 30 pg/ml) and E (3,050 +/- 880 from 140 +/- 20 pg/ml) more than it increased coronary sinus NE (460 +/- 50 from 150 +/- 30 pg/ml) and E (660 +/- 160 from 90 +/- 20 pg/ml) but significantly less (P less than 0.05) than observed in intact dogs. These experiments indicate that hemorrhage, unlike exercise and sympathetic nerve stimulation, does not induce net overflow of NE from the heart.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

Reducing lipofuscin accumulation and cardiomyocytic senescence of aging heart by enhancing autophagy

Highlights: • Lipofuscin accumulation varies in different regions and tissues of the heart. • Lipofuscin accumulation is related to cardiomyocytic senescence. • Enhancement of autophagy alleviates lipofuscin accumulation and myocardial senescence. Cardiomyocytes are particularly prone to lipofuscin accumulation. In the aging heart, lipofuscin accumulation is augmented. This study examined distribution of lipofuscin and senescent cardiomyocytes and evaluated improvement of lipofuscin accumulation and cardiomyocytic senescence of the aging heart after treatment with rapamycin. The results of Schmorl staining, Sudan black staining and autofluorescence detection showed that there was more lipofuscin in the myocardium of the ventricles especially in the left ventricle. The conductive tissue contained less lipofuscin than the myocardium. In the aged hearts, lipofuscin accumulation and senescent cardiomyocytes were increased, and the level of autophagy was reduced. In double staining of Sudan black B and senescence-associated β-galactosidase, 10%–20% lipofuscin-loaded cardiomyocytes became senescent. All senescent cardiomyocytes contained lipofuscin deposits. After enhancing autophagy with feed of rapamycin for six months, lipofuscin accumulation and senescence of cardiomyocytes were improved in old rats. Colocalization of autophagic structure and lipofuscin as well as electron micrographs showed that some lipofuscin-loaded lysosomes were sequestrated by autophagic structures. This study suggests that rapamycin-enhanced autopahgy is effective for reducing lipofuscinogenesis and promoting degradation of lipofuscin. Therefore, enhancing autophagy is a novel therapy for alleviating lipofuscin accumulation and myocardial senescence.

60 APPLIED LIFE SCIENCES↗

Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate

Abstract Many health diagnostic systems demand noninvasive sensing of respiratory rate, respiratory volume, and heart rate with high user comfort. Previous methods often require multiple sensors, including skin-touch electrodes, tension belts, or nearby off-the-body readers, and hence are uncomfortable or inconvenient. This paper presents an over-clothing wearable radio-frequency sensor study, conducted on 20 healthy participants (14 females) performing voluntary breathing exercises in various postures. Two prototype sensors were placed on the participants, one close to the heart and the other below the xiphoid process to couple to the motion from heart, lungs and diaphragm, by the near-field coherent sensing principle. We can achieve a satisfactory correlation of our sensor with the reference devices for the three vital signs: heart rate ( r = 0.95), respiratory rate ( r = 0.93) and respiratory volume ( r = 0.84). We also detected voluntary breath-hold periods with an accuracy of 96%. Further, the participants performed a breathing exercise by contracting abdomen inwards while holding breath, leading to paradoxical outward thorax motion under the isovolumetric condition, which was detected with an accuracy of 83%.

60 APPLIED LIFE SCIENCES↗

Long-Term Effects of Very Low Dose Particle Radiation on Gene Expression in the Heart: Degenerative Disease Risks

Compared to low doses of gamma irradiation (γ-IR), high-charge-and-energy (HZE) particle IR may have different biological response thresholds in cardiac tissue at lower doses, and these effects may be IR type and dose dependent. Three- to four-month-old female CB6F1/Hsd mice were exposed once to one of four different doses of the following types of radiation: γ-IR 137Cs (40-160 cGy, 0.662 MeV), 14Si-IR (4-32 cGy, 260 MeV/n), or 22Ti-IR (3-26 cGy, 1 GeV/n). At 16 months post-exposure, animals were sacrificed and hearts were harvested and archived as part of the NASA Space Radiation Tissue Sharing Forum. These heart tissue samples were used in our study for RNA isolation and microarray hybridization. Functional annotation of twofold up/down differentially expressed genes (DEGs) and bioinformatics analyses revealed the following: (i) there were no clear lower IR thresholds for HZE- or γ-IR; (ii) there were 12 common DEGs across all 3 IR types; (iii) these 12 overlapping genes predicted various degrees of cardiovascular, pulmonary, and metabolic diseases, cancer, and aging; and (iv) these 12 genes revealed an exclusive non-linear DEG pattern in 14Si- and 22Ti-IR-exposed hearts, whereas two-thirds of γ-IR-exposed hearts revealed a linear pattern of DEGs. Thus, our study may provide experimental evidence of excess relative risk (ERR) quantification of low/very low doses of full-body space-type IR-associated degenerative disease development.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Application of NASTRAN for stress analysis of left ventricle of the heart

Knowing the stress and strain distributions in the left ventricular wall of the heart is a prerequisite for the determination of the muscle elasticity and contractility in the process of assessing the functional status of the heart. NASTRAN was applied for the calculation of these stresses and strains and to help in verifying the results obtained by the computer program FEAMPS which was specifically designed for the plane-strain finite-element analysis of the left ventricular cross sections. Adopted for the analysis are the true shape and dimensions of the cross sections reconstructed from multiplanar X-ray views of a left ventricle which was surgically isolated from a dog's heart but metabolically supported to sustain its beating. A preprocessor was prepared to accommodate both FEAMPS and NASTRAN, and it has also facilitated the application of both the triangular element and isoparameteric quadrilateral element versions of NASTRAN. The stresses in several crucial regions of the left ventricular wall calculated by these two independently developed computer programs are found to be in good agreement. Such confirmation of the results is essential in the development of a method which assesses the heart performance.

Pao, Y. C.↗

Computed Flow Through An Artificial Heart And Valve

NASA technical memorandum discusses computations of flow of blood through artificial heart and through tilting-disk artificial heart valve. Represents further progress in research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478). One purpose of research to exploit advanced techniques of computational fluid dynamics and capabilities of supercomputers to gain understanding of complicated internal flows of viscous, essentially incompressible fluids like blood. Another to use understanding to design better artificial hearts and valves.

Rogers, Stuart E.↗

Computed Flow Through An Artificial Heart Valve

Report discusses computations of blood flow through prosthetic tilting disk valve. Computational procedure developed in simulation used to design better artificial hearts and valves by reducing or eliminating following adverse flow characteristics: large pressure losses, which prevent hearts from working efficiently; separated and secondary flows, which causes clotting; and high turbulent shear stresses, which damages red blood cells. Report reiterates and expands upon part of NASA technical memorandum "Computed Flow Through an Artificial Heart and Valve" (ARC-12983). Also based partly on research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478).

Rogers, Stewart E.↗

Ambulatory blood pressure and heart rate during shuttle flight, entry and landing

Ambulatory blood pressures (BP) and heart rates (HR) were recorded on a series of early Shuttle flights during preflight and pre-entry, entry, landing and egress. There were no significant differences between flight and preflight values during routine activity. Systolic blood pressure was slightly elevated in the deorbit period and systolic and diastolic blood pressure and heart rates were all elevated with onset of gravitoinertial loads and remained so through egress. Two of seven subjects had orthostatic problems in egress but their data did not show significant differences from others except in heart rate. Comparison of this data to that from recent studies show even larger increase in HR/BP values during current deorbit and entry phases which is consistent with increased heat and weight loads imposed by added survival gear. Both value and limitations of ambulatory heart rate/blood pressure data in this situation are demonstrated.

Thornton, W.↗

Heart Rate Variability During Early Adaptation to Space

A recent report hypothesized that episodes of space motion sickness (SMS) were reliably associated with low frequency oscillations (less than 0.03 to less than 0.01 Hz) in heart rate variability. This paper archives a large data set for review of investigators in this field which may facilitate the evaluation of this hypothesis. Continuous recording of Electro-cardiography (ECG) and other measures were made for 6 to 12 hours per day (waking hours) of six Shuttle crewmembers for the first 3 mission days of two separate Shuttle flights. Spectral analyses of heart rate variability during approximately 200 hours of inflight is presented. In addition, nearly 200 hours of data collected on these same individuals during ground tests prior to the mission are presented. The Purpose of this Publication is to document the incidence of low frequency oscillations of heart rate in 4 people exposed to microgravity over a period of five days. In addition, this report contains spectral analyses of heart rate data collected on these same individuals during ground-based mission simulations. By archiving these data in this manner, it is our intention to make this information available to other investigators interested in studying this phenomena.

Toscano, W. B.↗