Search NASA⌕ Search

SEARCH · Search NASA

Results for “HIGH VOLTAGE SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Pathways to the Next-Generation Power System With Inverter-Based Resources: Challenges and recommendations

Managing the stability of today's electric power systems is based on decades of experience with the physical properties and control responses of large synchronous generators. Today's electric power systems are rapidly transitioning toward having an increasing proportion of generation from nontraditional sources, such as wind and solar (among others), as well as energy storage devices, such as batteries. In addition to the variable nature of many renewable generation sources (because of the weather-driven nature of their fuel supply), these newer sources vary in size - from residential-scale rooftop systems to utility-scale power plants - and they are interconnected throughout the electric grid, both from within the distribution system and directly to the high-voltage transmission system. Most important for our purposes, many of these new resources are connected to the power system through power electronic inverters. Collectively, we refer to these sources as inverter-based resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Prototype High-Voltage Pulsed Power Supply for Control of the ITER Shattered Pellet Injection System Flyer Plate Valve

A high-voltage pulsed power supply (HVPPS) has been designed, prototyped, and tested for driving an eddy current actuated propellant valve for the International Thermonuclear Experimental Reactor (ITER) disruption mitigation system. The high-voltage (HV) dc supply output voltage is software programmable, and the energy storage capacitor bank can be readily reconfigured as 200, 400, 600, and 800 μ F, enabling testing and optimization of both the valve drive and valve systems. Multiple system parameters are monitored before, during, and after each firing of the valve. The system parameters are both displayed and stored for further analysis. Control of the setup, firing sequence, and data collection is automated using a LabVIEW-based control program. The programmability and reconfigurability of this system collectively provide a flexible and robust platform for system refinement and optimization. In this article, a summary of the system will be provided including operational sequences, HV switching and associated triggering methods and circuits, and results measured while firing a solid frozen pellet. Additionally, planned refinement activities toward meeting all requirements for ITER integration will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Speed Medium Voltage CHP System with Advanced Grid Support

The project was a collaboration between Clemson University and TECO Westinghouse Motor Company. The goal of the project was to develop a medium voltage commercial grid-tied system with advanced grid support functions. Current state-of-the-art in medium voltage, multi-megawatt power electronic systems do not support advanced grid functions, traditionally due to power electronic limitations and required applications. The developed system is capable of interacting with the power system at the distribution level to efficiently integrate gas turbine generation systems or any other ac generation system with up to 20MWe of power production capacity. This project demonstrated a high level of technical readiness of the 1MW, 500Hz, 15000 RPM high frequency Combined Heat and Power (CHP) generator and electric machine system, utilizing advanced grid support functions required by IEEE Std. 1547-2018.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Fidelity Learning for Distribution System Voltage Probabilistic Analysis with High Penetration of PVs

This paper proposes a multi-fidelity learning approach for distribution voltage probabilistic analysis with high penetration of PVs. Unlike the existing machine learning-based approaches that require a large number of high fidelity data to achieve satisfactory results, our approach strategically leverage massive low fidelity data from inaccurate model simulations and limited high fidelity historical data. The key idea is to use low-fidelity data to establish an initial model and then the high-fidelity data to calibrate and correct the constructed low-fidelity model. This allows us to fuse low- and high-fidelity data, yielding a high fidelity prediction model. Results obtained from a realistic feeder in US with 80% penetration of PVs show that the proposed approach can achieve a similar accuracy to the one with a large number of high fidelity data. This significantly highlights the advantages of the proposed method as compared to existing data-hungry machine learning methods. Different levels of fidelity data and their impacts are also investigated.

distribution system↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LDRD23-0184: Resilience and Hazard Risk Assessment to Prioritize Security Operations for Decisions and Impacts (RHAPSODI)

Recent examples provide a significant concern for the resilience of the U.S. electric grid and represent a need for enhanced decision-making to address an increasingly wide range of complex system interactions and potential consequences. In response, this LDRD project produced a proof-of-concept evaluation called the Resilience and Hazard Assessment to Prioritize Security Operations for Decisions and Impacts (RHAPSODI) methodology as an agile and flexible analytic framework capable of addressing multiple, diverse threats to desired electric grid performance. After empirically grounding needs for the future of U.S. electric grid resilience, this project employed the systems-theoretic process analysis (STPA) to develop a systems engineering risk model. The results of a completed feasibility study of a notional high voltage transmission system demonstrate an improved ability to incorporate both spatial (e.g., geographically distributed) and temporal (e.g., dynamic and time-dependent) elements of security risk to the gird. The success of this LDRD project provides the foundation for further evolution of the systems engineering risk model for the grid; derivation of quantitative approaches to evaluate risk and resilience performance; facilitation of agile experimenting and grid sensitivity to a range of vulnerabilities; and development of tools to assist decision-makers in enhancing U.S. electrical grid resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Aqueous spray-drying synthesis of alluaudite Na 2+2x Fe 2–x (SO 4 ) 3 sodium insertion material: studies of electrochemical activity, thermodynamic stability, and humidity-induced phase transition

In pursuit of high-energy density sodium insertion materials, polyanionic frameworks can be designed with tuneable high-voltage operation stemming from inductive effect. Alluaudite Na 2 Fe 2 (SO 4 ) 3 polysulfate forms one such earth-abundant compound registering the highest Fe 3+ /Fe 2+ redox potential (ca. 3.8 V vs. Na/Na + ). While this SO 4 -based system exhibits high voltage operation, it is prone to thermal decomposition and moisture attack leading to hydrated derivatives, making its synthesis cumbersome. Also, the Na–Fe–S–O quaternary system is rich with (anhydrous to hydrated) phase transitions. Herein, we demonstrate scalable aqueous-based spray drying synthesis of alluaudite Na 2+2x Fe 2–x (SO 4 ) 3 sodium insertion material involving the formation of bloedite Na 2 Fe(SO 4 ) 2 ·4H 2 O as an intermediate phase. Moreover, a reversible phase transition from alluaudite to bloedite under controlled conditions of temperature and relative humidity is reported for the first time. Thermochemistry measurements revealed the enthalpies of formation (ΔH° f ) of alluaudite and bloedite are exothermic. Hydrated bloedite (ΔH° f = –117.16 ± 1.10 kJ/mol) was found to be significantly more energetically stable than anhydrous alluaudite (ΔH° f = –11.76 ± 1.25 kJ/mol). The calorimetric data support the observed synthesis and transformation (hydration-dehydration) pathways. Spray drying route led to spherical morphology delivering capacity ~80 mAh/g. Spray drying can be extended for rapid economic synthesis of sulfate class of battery materials.

25 ENERGY STORAGE↗

Uncontrolled Electric Vehicle Charging Impacts on Distribution Electric Power Systems with Primarily Residential, Commercial or Industrial Loads

An increase in Electric Vehicles (EV) will result in higher demands on the distribution electric power systems (EPS) which may result in thermal line overloading and low voltage violations. To understand the impact, this work simulates two EV charging scenarios (home- and work-dominant) under potential 2030 EV adoption levels on 10 actual distribution feeders that support residential, commercial, and industrial loads. The simulations include actual driving patterns of existing (non-EV) vehicles taken from global positioning system (GPS) data. The GPS driving behaviors, which explain the spatial and temporal EV charging demands, provide information on each vehicles travel distance, dwell locations, and dwell durations. Then, the EPS simulations incorporate the EV charging demands to calculate the power flow across the feeder. Simulation results show that voltage impacts are modest (less than 0.01 p.u.), likely due to robust feeder designs and the models only represent the high-voltage (“primary”) system components. Line loading impacts are more noticeable, with a maximum increase of about 15%. Additionally, the feeder peak load times experience a slight shift for residential and mixed feeders (≈1 h), not at all for the industrial, and 8 h for the commercial feeder.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Critical Insights into Solvent Choice for High-Voltage Organosulfur Electrolytes

Organosulfur electrolytes are promising candidates for enabling high-voltage cathodes due to their superior oxidative stability compared to conventional carbonate-based systems. However, their viscous nature and inability to passivate the anode necessitate the use of passivating agents and diluents to achieve meaningful charge/discharge rates. In this study, we investigate the use of cyclic fluorinated carbonates (CFCs) to form passivating interphases on electrode surfaces, aiming to optimize electrolyte performance in high-voltage systems. Electrolyte formulations containing 1.2 M LiPF 6 in a CFC:sulfone:1,1,2,2-tetrafluoroethyl-2,2,3,3-tetrafluoropropylether (TTE) mixture (2/5/3 V/V/V) were assessed in full-cell configurations with a LiNi 0.8 Mn 0.1 Co 0.1 O 2 (FCG-NMC) cathode and a 4.5 V upper cutoff potential. The results reveal that 3-3-3-trifluoropropylene carbonate (TFPC) combined with ethyl methyl sulfone (EMS) optimizes electrolyte performance, resulting in lower resistance buildup and reduced capacity loss compared to commercial electrolytes. We also explore the failure mechanisms of several carbonate/sulfone mixtures and identify key considerations for electrolyte compatibility in high-voltage systems. TFPC enhances cycling stability and lowers overall cell resistance, while fluoroethylene carbonate (FEC) formulations, despite higher ionic conductivity, fail to form adequate passivation layers, leading to rapid capacity loss. Additionally, EMS provides superior physical properties that avoid common failure modes seen with other sulfone solvents like methyl isopropyl sulfone and tetramethylene sulfone. Furthermore, this study underscores the importance of carefully selecting passivating carbonates and sulfone solvents to improve electrolyte performance and expand the viability of high-voltage electrolyte systems.

LiNi0.8Mn0.1Co0.1O2 cathode↗

Cyber Attack Resilient HVDC System (CARDS) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE-OE funded project DE-OE0000824, where ABB Inc. (ABB), in collaboration with University of Illinois at Urbana-Champaign (UIUC), Bonneville Power Administration (BPA), Argonne National Laboratories (ANL), and University of Idaho (UI) pursued the development of a system of defense for High Voltage Direct Current transmission systems against cyber-attacks (CARDS). An HVDC substation with CARDS features will be more capable of mitigating cyber-attacks especially those that seek to control or interrupt the power flow in the HVDC line. It empowers existing HVDC intelligent electronic devices to collaborate in identifying and blocking malicious intents to trip HVDC AC circuit breakers, block thyristor valves, misconfigure devices settings, even though the commands and the measurements comply with correct syntax. The CARDS functions utilize the physics of electromagnetic AC and DC systems, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected HVDC substation devices. With the aim of advancing the state of the art, the team proceeded to develop a demonstrable system against cyber-attacks in an HVDC substation environment, via functional upgrades to existing firmware of commercial off-the-shelf HVDC station devices, and/or embedded hardware, without the need for additional instrumentation nor new instrumentation technologies. It is to ensure that the solutions resulting from the project will support the HVDC devices currently installed in the US electricity delivery infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wideband precision stabilization of the -18.6kV retarding voltage for the KATRIN spectrometer

The Karlsruhe Tritium Neutrino Experiment (KATRIN) measures the effective electron anti-neutrino mass with an unprecedented design sensitivity of 0.2 eV (90 % C.L.). In this experiment, the energy spectrum of beta electrons near the tritium decay endpoint is analyzed with a highly accurate spectrometer. To reach the KATRIN sensitivity target, the retarding voltage of this spectrometer must be stable to the ppm (1 × 10 -6 ) level and well known on various time scales (μs up to months), for values around -18.6 kV. A custom-designed high-voltage regulation system mitigates the impact of interference sources in the absence of a closed electric shield around the large spectrometer vessel. In this article, we describe the regulation system and its integration into the KATRIN setup. Independent monitoring methods demonstrate a stability within 2 ppm, exceeding KATRIN's specifications.

47 OTHER INSTRUMENTATION↗

A Multistage Stochastic Transmission Expansion Algorithm for Wide-Area Planning under Uncertainty

The overall objective for this project was to develop and demonstrate a set of methods for solving the transmission investment problem for a large network considering many possible scenarios of future conditions and multiple decision points when investments can be made. Project sub-objectives achieved this goal through a succession of extending the methods to apply to problems with increasing complexity or additional features, including the number of decision points, whether generation and transmission are co-optimized, and whether AC or DC power flow is used. A transmission model was developed for the Western Electric Coordinating Council (WECC) region, the high-voltage transmission system that serves the western third of the continental U.S. Using a dataset provided by WECC and by researchers from John Hopkins University, we have validated and demonstrated the model and used it to compare the new method for solving multi-stage stochastic transmission planning to several state-of-the-art techniques. The project has resulted in several key outcomes and achievements: The covariance-based method for choosing a small set of hours to represent short-term variability has superior performance in terms of accuracy to existing methods, including K-means clustering and Importance Sampling; The combined partitioning method for long-term uncertainty with the nested clustering approach for choosing representative hours for each long-term group has superior accuracy for equivalent computational effort compared with existing methods; Using the partitioning/clustering method combined with Sample Average Approximation provides both statistical bounds on the quality of the solution and at the same time, a complete investment plan for all contingencies in the full uncertainty set; no existing methods can provide both at the same time; The method is demonstrated to work well for choosing both transmission and generation investments; A variant on the method allows for both scenario selection and simultaneous correction for the error from the DC power flow approximation to provide a tractable method for AC power flow-based transmission planning under uncertainty; The method applied to the WECC case study demonstrates the additional value to the system operator and the consumer of identifying flexible investment options in the near-term decisions. In particular, the case study exhibits significant option value in postponing some transmission additions that appear useful but in some long-term system states create new congestion problems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

High-Voltage Pulsed Power Generator for Beam Injection Systems

Beam injection systems in hadron colliders require kickers generating ±50 kV peak voltages into a 50 Ω impedance, with peak currents of 1000 A and sub-10 ns rise and fall times. This paper presents a novel high-voltage pulse power generator utilizing a distributed pulser architecture. It combines gallium nitride (GaN) transistors in a Marx topology with an inductive adder, achieving nanosecond-scale switching speeds and high-power efficiency. Compared to other solutions such as based on MOSFETs or fast ionization dynistors, our development offers superior peak and average power performance, reduced system complexity, and enhanced reliability, marking a significant step forward in high-voltage pulse generation for accelerator applications.

Smirnov, Alexander (ORCID:0000000280631691)↗

Cybersecurity of Wide Area Monitoring, Protection and Control Systems for HVDC Applications

The flexibility provided by High Voltage Direct Current (HVDC) systems can be further extended by Wide Area Monitoring, Protection, and Control (WAMAPC) systems. WAMPAC systems enable many HVDC applications and, on the other hand, inevitably introduce cybersecurity concerns that need to be addressed. In this work, a security domain layer and decision framework is reported to detect and mitigate the impact of false data injection (FDI) attacks targeting HVDC stations. Specifically, a rule-based cyber-attack detection method is introduced and implemented on Raspberry Pi and tested on the real-time HVDC simulation facility on the real-time digital simulator (RTDS) platform at ABB U.S. Corporate Research Center.

cybersecurity↗

Hybrid EMT-TS Simulation Strategies to Study High Bandwidth MMC-Based HVdc Systems

Modular multilevel converters (MMCs) are widely used in the design of modern high-voltage direct current (HVdc) transmission system. High-fidelity dynamic models of MMCs-based HVdc system require small simulation time step and can be accurately modeled in electro-magnetic transient (EMT) simulation programs. The EMT program exhibits slow simulation speed and limitation on the size of the model and brings certain challenges to test the high-fidelity HVdc model in system-level simulations. This paper presents the design and implementation of a hybrid simulation framework, which enables the co-simulation of the EMT model of Atlanta-Orlando HVdc line and the transient stability (TS) model of the entire Eastern Interconnection system. This paper also introduces the implementation of two high-fidelity HVdc line models simulated at different time steps and discusses a dedicated method for sizing the buffer areas on both sides of the HVdc line. The simulation results of the two HVdc models with different sizes of buffer areas are presented and compared.

Liu, Yuan↗

GUI Control System for the Mu2e Electrostatic Septum High Voltage at Fermilab

The Mu2e Experiment has stringent beam structure requirements; namely, its proton bunches with a time structure of 1.7 $\mu$s in the Fermilab Delivery Ring. This beam structure will be delivered using the Fermilab 8-GeV Booster, the 8-GeV Recycler Ring, and the Delivery Ring. The 1.7-$\mu$s period of the Delivery Ring will generate the required beam structure by means of a third order resonant extraction system operating on a single circulating bunch. The electrostatic septum (ESS) for this system is particularly challenging, requiring mechanical precision in a ultra high vacuum of 1 x 10$^-8$ Torr to generate 100 kV across 15 mm. This paper describes a graphical user interface that has been developed to automate the conditioning and commissioning process for the electrostatic septa. It is based on an interface to the Fermilab ACNET system using the ACSys Python Data Pool Manager (DPM) Client produced and maintained by Fermilab Accelerator Controls. Network interfacing between data pool managers made by the application and ACNET devices introduce an inherent (approximately 1 s) latency in throughput of the readouts. This delay is utilized to process and graph incoming data events of devices crucial to conditioning of a electrostatic septum (ESS). 'Ramping' and 'Monitoring' modes adjust settings of the power supply based on internal logic to efficaciously increase and maintain the high voltage (HV) in the ESS, easing the voltage setting on incidence of sparking or other possibly damaging events. A timestamped log file is produced as the application runs.

43 PARTICLE ACCELERATORS↗

Fidelity Analysis of Complex Large-Scale Simulation Models of PEs (MARS) in Future Power Grids

With the proliferation of power electronic (PE)-based resources in the electric grid, there have been numerous different kinds of simulation models developed and studied to understand their dynamic behavior. Study of PE-based resources using each simulation model has its own distinct advantages and disadvantages. Therefore it is very important to carefully select the appropriate model for the evaluation of the PE-based resources. In this paper, one such effort is made to analyze the different types of models in the case of a multi-port autonomous reconfigurable solar power plant (MARS). The MARS integrates a hybrid photovoltaic (PV)-energy storage system (ESS) plant to high-voltage direct current (HVdc) system and transmission alternating current (ac) grid. The dynamic models are evaluated under different test cases varying the short-circuit ratio (SCR) and control algorithms. Recommendations are provided on the equipment study needs based on the analysis completed.

Marthi, Phani Ratna Vanamali↗