At least 55 records · Page 3

Second-hand smoke exposure in outdoor hospitality venues: Smoking visibility and assessment of airborne markers

Highlights: • Smoking visibility remains widespread in outdoor hospitality venues in Madrid. • SHS levels are relatively high, especially in closed outdoor terraces. • Outdoor hospitality venues should be considered to become completely smoke-free. • Policymakers should ensure that the existing smoke-free regulations are enforced. After the implementation of smoke-free policies in indoor hospitality venues (including bars, cafeterias, restaurants, and pubs), smokers may have been displaced to their outdoor areas. We aimed to study smoking visibility and second-hand smoke exposure in outdoor hospitality venues.

54 ENVIRONMENTAL SCIENCES↗

Six Machine-Learning Methods for Predicting Hospital-Stay Duration for Patients with Sepsis: A Comparative Study

Sepsis is a life-threatening medical condition that, if not treated promptly, can result in tissue damage, organ failure, and death. According to the Centers for Disease Control, about 270,000 individuals die of sepsis in the US each year. Further, sepsis expenditures accounted for 13% of total US hospital costs in 2013, totaling more than $24 billion. Our project objectives were to determine if Machine Learning algorithms could reliably predict hospital stay duration for patients with sepsis. The data set we used has been de-identified and is freely available through the BupaR package. The data includes 1050 cases, 15214 events, and 16 types of actions related to sepsis patient care. First, we used process mining to determine how long each patient was in the hospital. Using BupaR’s functions, we created several process model graphs. These process models depict the movement of patients at a hospital and provide duration data for each patent case. Second, we identified outlier data and created two dataset versions: one with and one without outliers. We then applied the following analysis methods: Linear Regression, Random Forest, K-Nearest Neighbors, Neural Networks, XGBoost, and lightGBM. We compared the model validations for the six machine learning models using the same data-splitting method. We found that the XGBoost model had the best prediction accuracy of 73.9 percent for cases with outliers, and 79 percent for cases without outliers. We also found that the lightGBM model had the lowest mean absolute error between prediction and actual duration in days with 3.66 days for the case with outliers, and 2.4 days for the case without outliers. These two models outperformed the other four models. This work will be enhanced in the future by exploring new prediction algorithms and comparing them with the results of this study.

Chen, Lingtao↗

Nurses’ Satisfaction with Patient Room Lighting Conditions: A Study of Nurses in Four Hospitals with Differences in the Environment of Care

Lighting systems in patient rooms must balance energy efficiency concerns with the holistic needs of patients, families, and medical caregivers. This paper reports survey responses from 138 individuals working in medical-surgical units in four hospitals, with three of the hospitals having traditional lighting systems and the other hospital having a more contemporary lighting system. The results add to a growing evidence base on the effects of lighting on nurses’ job performance, job satisfaction, and overall perceptions of the environment, and provide evidence that innovative lighting approaches and technologies are worth considering as an investment by hospital administrators looking to improve employees’ and patients’ perceptions of the patient room environment. This knowledge is intended to help facility designers and managers incorporate nurses’ perspectives in their decisions, as well as to inform technologists and engineers developing future generations of lighting systems for patient rooms. These future systems will utilize solid-state lighting technologies, such as LEDs, and will provide new opportunities for adapting the intensity, distribution, and spectrum of light to better satisfy the holistic needs of patients and caregivers at different times of day or night.

Davis, Robert G.↗

Spatial and temporal variations in indoor environmental conditions, human occupancy, and operational characteristics in a new hospital building

The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.

54 ENVIRONMENTAL SCIENCES↗

The value of improved telecommunications service to hospitals: A preliminary assessment

In view of the rapid rate of development of domestic telecommunication services and the emphasis on private networks, it was sought to determine if hospitals had major requirements which could be aggregated and served by such networks. The value of the information transfer services judged to be most promising over the next twenty years was evaluated, based on expenditures and activity levels in five hospitals and one management services firm and the judgement of their senior staff. An implicit assumption is that services will become affordable once the hospital industry aggregates its requirements. A methodology to evaluate the value of telecommunication services in a hospital was developed and tested.

Potter, J. G.↗

Temporal dynamics of emergency department and hospital admissions of pediatric asthmatics

Asthma is a chronic disease that can result in exacerbations leading to urgent care in emergency departments (EDs) and hospitals. We examined seasonal and temporal trends in pediatric asthma ED (1997-1999) and hospital (1986-1999) admission data so as to identify periods of increased risk of urgent care by age group, gender, and race. All pediatric ED and hospital admission data for Maryland residents occurring within the state of Maryland were evaluated. Distinct peaks in pediatric ED and hospital asthma admissions occurred each year during the winter-spring and autumn seasons. Although the number and timing of these peaks were consistent across age and racial groups, the magnitude of the peaks differed by age and race. The same number, timing, and relative magnitude of the major peaks in asthma admissions occurred statewide, implying that the variables affecting these seasonal patterns of acute asthma exacerbations occur statewide. Similar gross seasonal trends are observed worldwide. Although several environmental, infectious, and psychosocial factors have been linked with increases in asthma exacerbations among children, thus far they have not explained these seasonal patterns of admissions. The striking temporal patterns of pediatric asthma admissions within Maryland, as described here, provide valuable information in the search for causes.

Emergency Treatment/utilization↗

Optimizing Travel Time to Outpatient Interventional Radiology Procedures in a Multi-Site Hospital System Using a Google Maps Application

The purpose of this study is to determine whether a custom Google Maps application can optimize site selection when scheduling outpatient interventional radiology (IR) procedures within a multi-site hospital system. The Google Maps for Business Application Programming Interface (API) was used to develop an internal web application that uses real-time traffic data to determine estimated travel time (ETT; minutes) and estimated travel distance (ETD; miles) from a patient’s home to each a nearby IR facility in our hospital system. Hypothetical patient home addresses based on the 33 cities comprising our institution’s catchment area were used to determine the optimal IR site for hypothetical patients traveling from each city based on real-time traffic conditions. For 10/33 (30%) cities, there was discordance between the optimal IR site based on ETT and the optimal IR site based on ETD at non-rush hour time or rush hour time. By choosing to travel to an IR site based on ETT rather than ETD, patients from discordant cities were predicted to save an average of 7.29 min during non-rush hour (p = 0.03), and 28.80 min during rush hour (p < 0.001). Using a custom Google Maps application to schedule outpatients for IR procedures can effectively reduce patient travel time when more than one location providing IR procedures is available within the same hospital system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ambient temperature and added heat wave effects on hospitalizations in California from 1999 to 2009

Highlights: • We examined temperature and heat wave links to hospitalizations in California. • Heat waves set as minimum 2 days above climate zone- and month-specific threshold. • Temperature linked with many hospital visit types (e.g. diabetes, ischemic stroke). • Added heat wave associations observed (e.g. acute renal failure), but less often. • Associations sometimes differed by demographic and region. Investigators have examined how heat waves or incremental changes in temperature affect health outcomes, but few have examined both simultaneously. We utilized distributed lag nonlinear models (DLNM) to explore temperature associations and evaluate possible added heat wave effects on hospitalizations in 16 climate zones throughout California from May through October 1999–2009. We define heat waves as a period when daily mean temperatures were above the zone- and month-specific 95th percentile for at least two consecutive days. DLNMs were used to estimate climate zone-specific non-linear temperature and heat wave effects, which were then combined using random effects meta-analysis to produce an overall estimate for each. With higher temperatures, admissions for acute renal failure, appendicitis, dehydration, ischemic stroke, mental health, non-infectious enteritis, and primary diabetes were significantly increased, with added effects from heat waves observed for acute renal failure and dehydration. Higher temperatures also predicted statistically significant decreases in hypertension admissions, respiratory admissions, and respiratory diseases with secondary diagnoses of diabetes, though heat waves independently predicted an added increase in risk for both respiratory types. Our findings provide evidence that both heat wave and temperature exposures can exert effects independently.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-241: Design and Implement of An Information Management System for Radiation Workers in a Hospital

Purpose: To meet the special needs of Medical Administration Division, an information management system for radiation workers in a hospital(IMSRWH) has been developed. Methods: There are about 200 radiation workers in 20 departments, such as department of radiology, department of radiation oncology, department of nuclear medicine, and so on. An IMSRWH server was used to run a database and web service of Apache+PHP+MySQL. The IMSRWH web service could be accessed with Internet Explorer(IE) to input, search, count, and print the radiation workers’ data. Every worker’s data information includes the following tables: registration, personal dose monitoring records, personnel certificate, training certificate, personnel license, medical examination, etc, and each table includes more optional detail information. Results: In the past year, the IMSRWH has been successfully developed and implemented in the hospital. According to the needs, the user rights are divided into: the system administrator, office manager, department manager and radiation worker. The different users have the different interfaces, and the appropriate authority permissions mean corresponding operations. The administrator and office manager could manage all personnel information, department manager could manage the staff information of his department, and the workers could view or modify their own information. Because information updates, involving hundreds of each entry and modification are complicated, each table information of all workers can be batch import from or export to a Microsoft Excel CSV format file, to update all together. However, it has only Chinese version now. Conclusion: It was demonstrated to be user-friendly and was proven to significantly improve the efficiency of the hospital management. Since it is an in-house developed system, more functions can be added or modified to further enhance its potentials in research and clinical practice.

60 APPLIED LIFE SCIENCES↗

Improving Results of Elective Abdominal Aortic Aneurysm Repair at a Low-Volume Hospital by Risk-Adjusted Selection of Treatment in the Endovascular Era

Several studies have observed both higher mortality rates and lower utilization of endovascular aneurysm repair (EVAR) at low-volume centers. This article presents the results of elective abdominal aortic aneurysm (AAA) repair at a low-volume center in the endovascular era and investigates whether postprocedural mortality can be improved by extension of EVAR application also in this setting. This is an 11.6-year retrospective cohort study of 132 patients undergoing elective surgical or endovascular AAA repair at a tertiary care academic hospital between 1997 and July 2008, i.e., a median volume of 12 cases per year. The study was divided into two periods of time according to the respective indications and contraindications for EVAR, which substantially changed in 2005. During period 1, only aneurysms with necks {>=}20 mm long and not involving the iliac arteries were treated endoluminally. Beginning in 2005, indication for EVAR was expanded to aortoiliac aneurysms with a minimum neck length of 15 mm. Preoperative risk was assessed by the SVS/AAVS comorbidity score. During the first period (1997-2004) 18.4% (16/87) of all patients received EVAR. By extending anatomical confines and indications for EVAR in 2005, the utilization rate of EVAR increased to 40.0% (18/45) during the second period (2005-July 2008; p = 0.007). Prevalence of preoperative risk factors did not change during the two observation periods. In contrast to period 1, high-risk patients were preferentially treated endoluminally during the second period, resulting in a significantly higher median SVS/AAVS score in the EVAR group (p < 0.001). A significant decrease in median length of stay at the intensive/intermediate care unit (5 vs. 2 days; p = 0.006) and length of in-hospital stay (20 vs. 12.5 days; p < 0.001) was observed during period 2. Overall perioperative mortality was reduced from 6.9% during the first period to 2.2% during the second period (p = 0.256). EVAR mortality was 0%, mortality after open repair was reduced from 8.5% to 3.7% (p = 0.414). In conclusion, by risk-adjusted selection of treatment and frequent application of EVAR, it is possible to improve perioperative outcome of elective AAA repair at a low-volume hospital. Mortality figures are similar to those of recent trials at high-volume centers, as reported in the literature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimally Invasive Treatment for Benign Prostatic Hyperplasia: Economic Evaluation from a Standardized Hospital Case Costing System

Purpose: Minimally invasive alternatives to transurethral resection of the prostate (TURP) such as prostate arterial embolization (PAE) and photoselective vaporization of the prostate (PVP) are being explored as adjuncts in the care of patients with benign prostatic hyperplasia. However, there are conflicting reports of the costs of these procedures. The purpose of this study was to compare the direct and indirect hospital costs of TURP, PAE and PVP. Materials and Methods: A chart review was performed in patients who underwent TURP, PVP and PAE from April 2015 to March 2017. All hospital costs were collected in accordance with the Ontario Case Costing Initiative, a standardized medical case costing system. Costs were characterized as direct or indirect and fixed or variable. Probabilistic sensitivity analysis was conducted to study cost uncertainty. Results: During the study period, a total of 209 men underwent TURP, 28 PVP and 21 PAE. Mean age (years) was as follows: TURP 71.43; PVP 73.66; PAE 70.77 (p = 0.366). Mean length of stay (days) was as follows: TURP 1.63; PVP 1.55; PAE 1 (p = 0.076). Total costs of the PAE group ($3829, SD $1582) were less than both PVP ($5719, SD $1515) and TURP groups ($5034, SD $1997, p < 0.001). There was no significant difference in direct costs between the groups. Monte Carlo simulation demonstrated that PAE was the least costly alternative majority of the time. Conclusions: The total hospital costs of PAE at our institution are significantly lower than those of PVP and TURP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spectrum of chronic kidney disease in China: A national study based on hospitalized patients from 2010 to 2015

ABSTRACT Aim To investigate the spectrum of chronic kidney disease (CKD) in China. Methods We used a large national in‐patient database covering 878 class three hospitals and involving 64.7 million adult patients in China from 2010 to 2015. The class 3 hospital in China is ranked as the top tier of medical system in China with at least 500 beds and the accreditation from health authorities. The specific causes of CKD were extracted from the International Classification of Diseases‐10 codes of discharge diagnoses. Results A total of 4.5% of hospitalized patients (1.8 million) were identified as CKD, with an increased percentage from 2010 (3.7%) to 2015 (4.7%). Increasing trends of diabetic kidney disease and hypertensive nephropathy were observed from 2010 to 2015 (19.5% vs 24.3% and 11.5% vs 15.9%, respectively), especially for urban residents from north China. The proportion of obstructive nephropathy also increased gradually (10.3% in 2010 vs 15.6% in 2015) and constituted another important cause of CKD for patients, especially for those from south China and rural residents. Conclusion The spectrum of CKD is changing in China, with variations over time and geographic regions, which has implication regarding developing the prevention strategy of CKD.

Huang, Yu‐Ming↗

Modeling Hospitals’ Adaptive Capacity during a Loss of Infrastructure Services

Resilience in hospitals ‐ their ability to withstand, adapt to, and rapidly recover from disruptive events ‐ is vital to their role as part of national critical infrastructure. This paper presents a model to provide planning guidance to decision makers about how to make hospitals more resilient against possible disruption scenarios. This model represents a hospital’s adaptive capacities that are leveraged to care for patients during loss of infrastructure services (power, water, etc.). The model is an optimization that reallocates and substitutes resources to keep patients in a high care state or allocates resources to allow evacuation if necessary. An illustrative example demonstrates how the model might be used in practice.

Vugrin, Eric D.↗

COVID-19 Evidence Accelerator: A parallel analysis to describe the use of Hydroxychloroquine with or without Azithromycin among hospitalized COVID-19 patients

Background: The COVID-19 pandemic remains a significant global threat. However, despite urgent need, there remains uncertainty surrounding best practices for pharmaceutical interventions to treat COVID-19. In particular, conflicting evidence has emerged surrounding the use of hydroxychloroquine and azithromycin, alone or in combination, for COVID-19. The COVID-19 Evidence Accelerator convened by the Reagan-Udall Foundation for the FDA, in collaboration with Friends of Cancer Research, assembled experts from the health systems research, regulatory science, data science, and epidemiology to participate in a large parallel analysis of different data sets to further explore the effectiveness of these treatments. Methods: Electronic health record (EHR) and claims data were extracted from seven separate databases. Parallel analyses were undertaken on data extracted from each source. Each analysis examined time to mortality in hospitalized patients treated with hydroxychloroquine, azithromycin, and the two in combination as compared to patients not treated with either drug. Cox proportional hazards models were used, and propensity score methods were undertaken to adjust for confounding. Frequencies of adverse events in each treatment group were also examined. Results: Neither hydroxychloroquine nor azithromycin, alone or in combination, were significantly associated with time to mortality among hospitalized COVID-19 patients. No treatment groups appeared to have an elevated risk of adverse events. Conclusion: Administration of hydroxychloroquine, azithromycin, and their combination appeared to have no effect on time to mortality in hospitalized COVID-19 patients. Continued research is needed to clarify best practices surrounding treatment of COVID-19.

60 APPLIED LIFE SCIENCES↗

Demonstration of Advanced Technologies for Multi-Load Washers in Hospitality and Healthcare -- Ozone Based Laundry Systems

The objective of this demonstration project was to evaluate market-ready retrofit technologies for reducing the energy and water use of multi-load washers in healthcare and hospitality facilities. Specifically, this project evaluated laundry wastewater recycling technology in the hospitality sector and ozone laundry technology in both the healthcare and hospitality sectors. This report documents the demonstration of ozone laundry system installations at the Charleston Place Hotel in Charleston, South Carolina, and the Rogerson House assisted living facility in Boston, Massachusetts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of Advanced Technologies for Multi-Load Washers in Hospitality and Healthcare -- Wastewater Recycling Technology

The objective of this demonstration project was to evaluate market-ready retrofit technologies for reducing the energy and water use of multi-load washers in healthcare and hospitality facilities. Specifically, this project evaluated laundry wastewater recycling technology in the hospitality sector and ozone laundry technology in both the healthcare and hospitality sectors. This report documents the demonstration of a wastewater recycling system installed in the Grand Hyatt Seattle.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resource Requirements Planning for Hospitals Treating Serious Infectious Disease Cases

This report presents a mathematical model of the way in which a hospital uses a variety of resources, utilities and consumables to provide care to a set of in-patients, and how that hospital might adapt to provide treatment to a few patients with a serious infectious disease, like the Ebola virus. The intended purpose of the model is to support requirements planning studies, so that hospitals may be better prepared for situations that are likely to strain their available resources. The current model is a prototype designed to present the basic structural elements of a requirements planning analysis. Some simple illustrati ve experiments establish the mo del's general capabilities. With additional inve stment in model enhancement a nd calibration, this prototype could be developed into a useful planning tool for ho spital administrators and health care policy makers.

59 BASIC BIOLOGICAL SCIENCES↗

Sequential Inference of Hospitalization Electronic Health Records Using Probabilistic Models

In the dynamic hospital setting, decision support can be a valuable tool for improving patient outcomes. Data-driven inference of future outcomes is challenging in this dynamic setting, where long sequences such as laboratory tests and medications are updated frequently. This is due in part to heterogeneity of data types and mixed-sequence types contained in variable length sequences. In this work we design a probabilistic unsupervised model for multiple arbitrary-length sequences contained in hospitalization Electronic Health Record (EHR) data. The model uses a latent variable structure and captures complex relationships between medications, diagnoses, laboratory tests, neurological assessments, and medications. It can be trained on original data, without requiring any lossy transformations or time binning. Inference algorithms are derived that use partial data to infer properties of the complete sequences, including their length and presence of specific values. We train this model on data from subjects receiving medical care in the Kaiser Permanente Northern California integrated healthcare delivery system. The results are evaluated against held-out data for predicting the length of sequences and presence of Intensive Care Unit (ICU) in hospitalization bed sequences. Our method outperforms a baseline approach, showing that in these experiments the trained model captures information in the sequences that is informative of their future values.

97 MATHEMATICS AND COMPUTING↗