Determination of Scopolamine in Human Saliva Using Solid Phase Extraction and LC/MS/MS

Purpose: Scopolamine is the preferred treatment for motion sickness during space flight because of its quick onset of action, short half-life and favorable side-effect profile. The dose administered depends on the mode of administration and usually ranges between 0.1 and 0.8 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids by using conventional HPLC methods. To measure scopolamine in saliva and thereby to evaluate the pharmacokinetics of scopolamine, we developed an LC/MS/MS method using off-line solid phase extraction. Method: Samples (0.5mL) were loaded onto Waters Oasis HLB co-polymer cartridges (10 mg, 1 mL) and eluted with 0.5 mL methanol without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 4 minutes. The mobile phase for separation was 90:10 (v/v) methanol: ammonium acetate (2 mM) in water, pH 5.0 +/- 0.1. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 yields 138.1 and internal standard (IS) hyoscyamine m/z = 290.2 yields 124.1. Results: The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at 1.7 and 3.2 min respectively. The linear range is 50-5000 pg/mL for scopolamine in saliva with correlation coefficients > 0.99 with a CV < 0.5 %. The intra-day and inter-day CVs are < 15 % for quality control samples with concentrations of 75, 300, 750 and 3000 pg/mL of scopolamine in human saliva. Conclusion: Solid phase extraction allows more rapid sample preparation and greater precision than liquid extraction. Furthermore, we increased the sensitivity and specificity by adjusting the LC mobile phase and using an MS/MS detector.

Wang, Zuwei↗

Extraterrestrial Amino Acids in the Almahata Sitta Meteorite

Amino acid analysis of a meteorite fragment of asteroid 2008 TC(sub 3) called Almahata Sitta was carried out using reverse-phase high-perfo rmance liquid chromatography coupled with UV fluorescence detection a nd time-of-flight mass spectrometry (HPLC-FD/ToF-MS) as part of a sam ple analysis consortium. HPLC analyses of hot-water extracts from the meteorite revealed a complex distribution of two- to six-carbon aliph atic amino acids and one- to three carbon amines with abundances rang ing from 0.5 to 149 parts-per-billion (ppb). The enantiomeric ratios of the amino acids alanine, Beta-amino-n-butyric acid (Beta-ABA), 2-amino-2- methylbutanoic acid (isovaline), and 2-aminopentanoic acid (no rvaline) in the meteorite were racemic (D/L approximately 1), indicat ing that these amino acids are indigenous to the meteorite and not te rrestrial contaminants. Several other non-protein amino acids were also identified in the meteorite above background levels including alpha -aminoisobutyric acid (alpha-AIB), 4-amino-2- methybutanoic acid, 4-a mino-3-methylbutanoic acid, and 3-, 4-, and 5-aminopentanoic acid. Th e total abundances of isovaline and AlB in Almahata Sitta are approximately 1000 times lower than the abundances of these amino acids found in the CM carbonaceous meteorite Murchison. The extremely love abund ances and unusual distribution of five carbon amino acids in Almahata Sitta compared to Cl, CM, and CR carbonaceous meteorites and may be due to extensive thermal alteration of amino acids on the parent aster oid by partial melting during formation or impact shock heating.

Glavin, Daniel P.↗

Ion-Exclusion Chromatography for Analyzing Organics in Water

A liquid-chromatography technique has been developed for use in the quantitative analysis of urea (and of other nonvolatile organic compounds typically found with urea) dissolved in water. The technique involves the use of a column that contains an ion-exclusion resin; heretofore, this column has been sold for use in analyzing monosaccharides and food softeners, but not for analyzing water supplies. The prior technique commonly used to analyze water for urea content has been one of high-performance liquid chromatography (HPLC), with reliance on hydrophobic interactions between analytes in a water sample and long-chain alkyl groups bonded to an HPLC column. The prior technique has proven inadequate because of a strong tendency toward co-elution of urea with other compounds. Co-elution often causes the urea and other compounds to be crowded into a narrow region of the chromatogram (see left part of figure), thereby giving rise to low chromatographic resolution and misidentification of compounds. It is possible to quantitate urea or another analyte via ultraviolet- and visible-light absorbance measurements, but in order to perform such measurements, it is necessary to dilute the sample, causing a significant loss of sensitivity. The ion-exclusion resin used in the improved technique is sulfonated polystyrene in the calcium form. Whereas the alkyl-chain column used in the prior technique separates compounds on the basis of polarity only, the ion-exclusion-resin column used in the improved technique separates compounds on the basis of both molecular size and electric charge. As a result, the degree of separation is increased: instead of being crowded together into a single chromatographic peak only about 1 to 2 minutes wide as in the prior technique, the chromatographic peaks of different compounds are now separated from each other and spread out over a range about 33 minutes wide (see right part of figure), and the urea peak can readily be distinguished from the other peaks. Although the analysis takes more time in the improved technique, this disadvantage is offset by two important advantages: Sensitivity is increased. The minimum concentration of urea that can be measured is reduced (to between 1/5 and 1/3 of that of the prior technique) because it is not necessary to dilute the sample. The separation of peaks facilitates the identification and quantitation of the various compounds. The resolution of the compounds other than urea makes it possible to identify those compounds by use of mass spectrometry.

Sauer, Richard↗

An Inverse Modeling Approach to Estimating Phytoplankton Pigment Concentrations from Phytoplankton Absorption Spectra

Phytoplankton absorption spectra and High-Performance Liquid Chromatography (HPLC) pigment observations from the Eastern U.S. and global observations from NASA's SeaBASS archive are used in a linear inverse calculation to extract pigment-specific absorption spectra. Using these pigment-specific absorption spectra to reconstruct the phytoplankton absorption spectra results in high correlations at all visible wavelengths (r(sup 2) from 0.83 to 0.98), and linear regressions (slopes ranging from 0.8 to 1.1). Higher correlations (r(sup 2) from 0.75 to 1.00) are obtained in the visible portion of the spectra when the total phytoplankton absorption spectra are unpackaged by multiplying the entire spectra by a factor that sets the total absorption at 675 nm to that expected from absorption spectra reconstruction using measured pigment concentrations and laboratory-derived pigment-specific absorption spectra. The derived pigment-specific absorption spectra were further used with the total phytoplankton absorption spectra in a second linear inverse calculation to estimate the various phytoplankton HPLC pigments. A comparison between the estimated and measured pigment concentrations for the 18 pigment fields showed good correlations (r(sup 2) greater than 0.5) for 7 pigments and very good correlations (r(sup 2) greater than 0.7) for chlorophyll a and fucoxanthin. Higher correlations result when the analysis is carried out at more local geographic scales. The ability to estimate phytoplankton pigments using pigment-specific absorption spectra is critical for using hyperspectral inverse models to retrieve phytoplankton pigment concentrations and other Inherent Optical Properties (IOPs) from passive remote sensing observations.

Moisan, John R.↗

Enantioselective Three-Dimensional High-Performance Liquid Chromatographic Determination of Amino Acids in the Hayabusa2 Returned Samples from the Asteroid Ryugu

The chirality of amino acids in extraterrestrial materials may provide an insight into the origin of the essential L-enantiopure amino acids in the terrestrial biosphere. In 2020, the Hayabusa2 mission succeeded in bringing back surface materials from the C-type asteroid (162173) Ryugu to the Earth. Amino acids were one of the targeted organic molecules to be studied in the Ryugu samples. To analyze the various structural isomers of amino acids, which were expected to be present, from the limited amount of the returned samples, the development of a highly-sensitive and selective analytical method was necessary. In the present study, a three-dimensional high-performance liquid chromatography (3D-HPLC) system has been developed for the enantioselective determination of five proteinogenic and three non-proteinogenic amino acids in the Ryugu samples, in which amino acids in the sample were separated by reversed-phase, anion-exchange and enantioselective columns after the fluorescence derivatization with 4-fluoro-7-nitro-2,1,3-benzoxadiozole. The applicability of the analytical system to the extraterrestrial samples was evaluated by analyzing several types of carbonaceous meteorites before applying the system to the Ryugu samples. In the analysis of the Ryugu samples, all of the target amino acids were successfully determined quantitatively. Non-proteinogenic amino acids including 2-amino-n-butyric acid, isovaline and norvaline, rarely present in the terrestrial environment, were found as almost racemic mixtures with 47.1 to 55.2%L.

Amino acids↗

Hydrocarbon group type determination in jet fuels by high performance liquid chromatography

Results are given for the analysis of some jet and diesel fuel samples which were prepared from oil shale and coal syncrudes. Thirty-two samples of varying chemical composition and physical properties were obtained. Hydrocarbon types in these samples were determined by fluorescent indicator adsorption (FIA) analysis, and the results from three laboratories are presented and compared. Recently, rapid high performance liquid chromatography (HPLC) methods have been proposed for hydrocarbon group type analysis, with some suggestion for their use as a replacement of the FIA technique. Two of these methods were used to analyze some of the samples, and these results are also presented and compared. Two samples of petroleum-based Jet A fuel are similarly analyzed.

Antoine, A. C.↗

Development of critical molecular weight-property specifications for high performance polymers used as adhesives and composites

The polyimide resin, LARC-160, was prepared from diethyl-3, 3', 4,4'-benzophenone tetracarboxylate, ethyl-5-norbornene-2,3-dicarboxylate and Jeffamine AP-22. The imidization reactions of NE and BTDE were studied by HPLC, C-13-NMR and IR. NE imidizes slowly at 12 C; BTDE imidizes when the resin is heated above 100 C. Both imidization reactions proceed directly to the imide. Neither amic acid is present in significant quantities at any stage of the imidization reactions. The monomer mixture was stored at 12 C for periods up to 14 months. The effects of resin aging at this temperature on the chemical composition of the resin monomer mixture and the imidized polymer formed on curing were investigated. Aging the resin monomer mixture has the effect of partially advancing the imidization reaction. The average size of the cured polymer increases slightly with resin age.

Kranbuehl, D. E.↗

Preparation and analysis of standardized waste samples for Controlled Ecological Life Support Systems (CELSS)

The preparation and analysis of standardized waste samples for controlled ecological life support systems (CELSS) are considered. Analysis of samples from wet oxidation experiments, the development of ion chromatographic techniques utilizing conventional high pressure liquid chromatography (HPLC) equipment, and an investigation of techniques for interfacing an ion chromatograph (IC) with an inductively coupled plasma optical emission spectrometer (ICPOES) are discussed.

Carden, J. L.↗

Partial Analysis of Insta-Foam

Insta-Foam, used as a thermal insulator for the non-critical area of the external tank during the prelaunch phase to minimize icing, is a two-component system. Component A has polyisocyanates, blowing agents, and stabilizers; Component B has the polyols, catalysts, blowing agents, stabilizers and fire retardant. The blowing agents are Freon 11 and Freon 12, the stabilizers are silicone surfactants, the catalysts are tertiary amines, and the fire retardant is tri-(beta-chloro-isopropyl) phosphate (PCF). High performance liquid chromatography (HPLC) was quantitatively identified polyols and PFC.

Chou, L. W.↗

Mammalian gravity receptors: Structure and metabolism

High performance liquid chromatography (HPLC) instrumentation was used for amino acid analysis of rat otoconial complexes. The amino acids of otoconial complexes pooled by origin from only 10 rats were analyzed. It is indicated that it should be possible to analyze complexes from only three rats, and perhaps fewer, which means that the method should be applicable to material from space flow rats. It is suggested that the organic otoconial phase is comparable in its complement of acidic amino acids to other calcium carbonate containing materials such as fish otoliths and certain mollusk shells. The organic material is high in acidic amino acids; and the relative proportions of aspirate, glutamate, threonine and serine appear to be similar to those found in neogastropod shells. Its significance to the evolution of biomineralization processes occurring in the animal kingdom is emphasized.

Ross, M.↗

Chlorophyll and carotenoid pigments of prochloron (prochlorophyta)

High-performance liquid chromatography (HPLC) with a gradient-elution technique was utilized to separate and quantify chlorophylls a and b as well as major carotenoid pigments present in freeze-dried preprations of prochloron-didemnid associations and in Prochloron cells separated from host colonies. Results confirm earlier spectrophotometric evidence for both chlorophylls a and b in this prokaryote. Chlorophyll a:b ratios range from 4.14 to 19.71; generally good agreement was found between ratios determined in isolated cell preprations and in symbiotic colonies (in hospite). These values are 1.5 to 5-fold higher than ratios determined in a variety of eukaryotic green plants. The carotenoids in Prochloron are quantitatively and qualitatively similar to those found in various freshwater and marine blue-green algae (cyanopbytes) from high-light environments. However, Prochloron differs from cyanophytes by the absence of myxoxanthophyll and related glycosidic carotenoids. It pigment characteristics are considered sufficiently different from those of cyanophytes to justify its assignment to a separate algal division.

Paerl, H. W.↗

Group-type hydrocarbon standards for high-performance liquid chromatographic analysis of middistillate fuels

A new high-performance liquid chromatographic (HPLC) method for group-type analysis of middistillate fuels is described. It uses a refractive index detector and standards that are prepared by reacting a portion of the fuel sample with sulfuric acid. A complete analysis of a middistillate fuel for saturates and aromatics (including the preparation of the standard) requires about 15 min if standards for several fuels are prepared simultaneously. From model fuel studies, the method was found to be accurate to within 0.4 vol% saturates or aromatics, and provides a precision of + or - 0.4 vol%. Olefin determinations require an additional 15 min of analysis time. However, this determination is needed only for those fuels displaying a significant olefin response at 200 nm (obtained routinely during the saturated/aromatics analysis procedure). The olefin determination uses the responses of the olefins and the corresponding saturates, as well as the average value of their refractive index sensitivity ratios (1.1). Studied indicated that, although the relative error in the olefins result could reach 10 percent by using this average sensitivity ratio, it was 5 percent for the fuels used in this study. Olefin concentrations as low as 0.1 vol% have been determined using this method.

Otterson, D. A.↗

SRM filament wound case resin characterization studies

The amine cured epoxy wet winding resin used in fabrication of the SRM filament wound case is analyzed. High pressure liquid chromatography (HPSC) is utilized extensively to study lot-to-lot variation in both resin and curing agent. The validity of quantitative hplc methodology currently under development in-process resin/catalyst assay is assessed.

Chou, L. W.↗

Development of acceptance criteria for batches of silane primer for external tank thermal protection system bonding applications

Concluding tests for the thermogravimetric and FTIR analyses of DC 1200 silane primers are discussed as well as methods for HPLC and GC analyses and for determining titanium and silicon by atomic absorption spectroscopy. Tables summarizes results obtained for residue, ash, titanium, silicone, Si/Ti ratio, OH-absorption, the lap-shear test, and the GC headspace for alcohols.

Mikes, F.↗

Distribution and abundance of organic thiols

The role of glutathione (GSH) in protecting against the toxicity of oxygen and oxygen by products is well established for all eukaryotes studied except Entamoeba histolytica which lacks mitochrondria, chloroplasts, and microtubules. The GSH is not universal among prokaryotes. Entamoeba histolytica does not produce GSH or key enzymes of GSH metabolism. A general method of thiol analysis based upon fluorescent labeling with monobromobimane and HPLC separation of the resulting thiol derivatives was developed to determine the occurrence of GSH and other low molecular weight thiols in bacteria. Glutathione is the major thiol in cyanobacteria and in most bacteria closely related to the purple photosynthetic bacteria, but GSH was not found in archaebacteria, green bacteria, or GRAM positive bacteria. It suggested that glutathione metabolism was incorporated into eukaryotes at the time that mitochondria and chloroplasts were acquired by endosymbiosis. In Gram positive aerobes, coenzyme A occurs at millimolar levels and CoA disulfide reductases are identified. The CoA, rather than glutathione, may function in the oxygen detoxification processes of these organisms.

Fahey, R.↗

Analysis of a spacecraft instrument ball bearing assembly lubricated by a perfluoroalkylether

An analysis of a spacecraft instrument ball bearing assembly, subjected to a scanning life test, was performed to determine the possible case of rotational problems involving these units aboard several satellites. The analysis indicated an ineffective transfer of a fluorinated liquid lubricant from a phenolic retainer to the bearing balls. Part of the analysis led to a novel HPLC separation method employing a fluorinated mobile phase in conjunction with silica based size exclusion columns.

Morales, W.↗

Photolysis products of CO, NH3 aND H2O and their significance to reactions on interstellar grains

With the increase in evidence that interstellar grains are the basic building blocks of comets and with the realization that comet collisions with the earth have probably occured at a much higher frequency than earlier assumed it may be presumed that interstellar dust chemistry played an important role in the early chemistry of the earth. As a part of the study of the photochemical processes taking place on interstellar grains the photolysis of mixtures of CO, NH3 and H2O was performed at 10 K, 77K and 298K. The reaction products were determined by GC/MS and HPLC analysis to be lactic acid, glycolic acid, hydroxyacetamide, urea, biuret, oxamic acid, oxamide, glyceric acid and glyceramide. Ethylene glycol and glycerol were also detected but is is not clear at present whether these are true photoproducts or contaminants. The mechanism of formation of these molecules are discussed as well as their possible significance to the origins of life.

Ferris, J. P.↗

Synthesis and analysis in studies of chemical evolution

Studies of the various processes that may have given rise to life on the Earth have demonstrated the appropriateness of an approach that makes use of analysis and synthesis. Analysis of extraterrestrial samples in the form of meteorites has demonstrated the presence of several precursors of biomolecules, most notably a full suite of nucleic acid bases and nucleotides of biological significance. These species were determined after exhaustive extraction of the sample and subsequent analysis using HPLC, GC, MS, and GC-MS. Procedural blanks indicate that these molecules are likely not the result of contamination during the extraction and analysis process. Similar species were found as products of spark discharge experiments in atmospheres thought to mimic primitive Earth conditions. These results indicate that the basic chemistry underlying these syntheses is common, and that life may not be unique to the Earth. Studies underway in the laboratory make use of proton nuclear magnetic resonance spectroscopy as a probe to assess associations between selected amino acids and any of several nucleotides comprising their genetic code and genetic anticode sequences. These studies demonstrate a clear selectivity by the anticode sequences, thus confirming the hydrophobicity studies performed by Lacey et al. These studies further support the contention that life is likely a natural result of the physics and chemistry of the universe.

Ponnamperuma, C.↗