Search NASA⌕ Search

SEARCH · Search NASA

Results for “HUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Effect of simulated weightlessness on the postural response of microvascular cutaneous blood flow

The effect of simulated weightlessness (1 week of bed rest) on the response of cutaneous microcirculatory blood flow to postural changes was investigated by measuring rates of the cutaneous blood flow in the central forehead and in the dorsum of the left foot in subjects who were tested in -6 deg head-down tilt (HDT) and 60-deg head-up tilt (HUT) before and after the week of bed rest. It was found that, when the subjects were moved from HUT to HDT before the bed rest period, the forehead cutaneous blood flow increased (in comparison to no-tilt baseline), due to increased arterial pressure, by about 26 percent, and that the response was the same on the first and the second day after 1 week of bed rest. The cutaneous blood flow in the dorsum of the foot decreased by about 46 percent in response to tilting from HDT to HUT both before and after bedrest.

Aratow, M.↗

Determination of ionic abundances in the Io torus using the Hopkins Ultraviolet Telescope

Attention is given to a 415-1864-A spectrum of the emissions from the Io torus with about 3-A resolution in first order (830-1864 A) obtained with HUT in December 1990. A list of the 31 strongest features shows that, apart from five features that are totally or partially terrestrial, all are due to O(+), S(+), S(2+), and S(3+). There is no evidence for elements other than oxygen and sulfur. The spectrum shows many additional weaker emission features so that the existence of minor species cannot be ruled out at this time. Because the HUT spectrum contains well-resolved lines for all four of the major species, the mixing ratio (Ni/ne) for each one can be determined without using models of the spectral emissions, or a detailed geometric model of the torus plasma. The relative concentration of O(+) determined from the HUT observation is 38 percent less than that obtained from the Voyager UVS data.

Moos, H. W.↗

The Hopkins Ultraviolet Telescope - Performance and calibration during the Astro-1 mission

Results are reported of spectrophotometric observations, made with the Hopkins Ultraviolet Telescope (HUT), of 77 astronomical sources throughout the far-UV (912-1850 A) at a resolution of about 3 A, and, for a small number of sources, in the extreme UV (415-912 A) beyond the Lyman limit at a resolution of about 1.5 A. The HUT instrument and its performance in orbit are described. A HUT observation of the DA white dwarf G191-B2B is presented, and the photometric calibration curve for the instrument is derived from a comparison of the observation with a model stellar atmosphere. The sensitivity reaches a maximum at 1050 A, where 1 photon/sq cm s A yields 9.5 counts/s A, and remains within a factor of 2 of this value from 912 to 1600 A. The instrumental dark count measured on orbit was less than 0.001 counts/s A.

Davidsen, Arthur F.↗

Far-ultraviolet observations of the Crab Nebula using the Hopkins Ultraviolet Telescope

Observations of the FUV spectrum of the central portion of the Crab Nebula SNR using the Hopkins Ultraviolet Telescope (HUT) aboard the Astro-1 space shuttle mission in December 1990 are reported. The C IV 1549-A emission line shows two resolved components representing the front and back sides of the shell expanding at roughly +/- 1100 km/s. The He II 1640-A emission line shows only a blueshifted component corresponding to the near side of the shell. The HUT observation is compared to optical emission-line imagery and to archival IUE observations. This comparison indicates that a distribution emission component, consisting of either a number of individually faint filaments or a diffuse component, produces the bulk of the emission seen by HUT. A grid of photoionization models for the Crab Nebula filaments is calculated to infer the range of limits. The differing UV line ratios observed for these components indicates that varying carbon and/or He abundances are present in the observed material.

Blair, William P.↗

Enhanced carotid-cardiac baroreflex response and elimination of orthostatic hypotension 24 hours after acute exercise in paraplegics

To test the hypothesis that an acute bout of maximal exercise can ameliorate orthostatic hypotension consequent to prolonged wheelchair confinement, we evaluated heart rate (HR), systolic (SBP) and diastolic (DBP) blood pressure responses during 15 minutes of 70 degrees head-up tilt (HUT) in 10 paraplegic subjects 24 hours after arm crank exercise designed to elicit maximal effort, and during a control (no exercise) conditions. Additionally, the carotid baroreceptor stimulus-cardiac response relationship was determined by measurement of R-R interval during external application of graded pressures to the carotid sinuses. One week separated the treatment conditions. The maximum slope of the carotid-cardiac baroreflex response was increased (p = 0.049) by exercise (6.2 +/- 1.7 msec/mmHg) compared to control (3.3 +/- 0.6). During control HUT, HR increased from 61 +/- 1 to 90 +/- 7 bpm (p = 0.001) while SBP decreased from 118 +/- 5 to 106 +/- 9 mmHg (p = 0.025). During HUT 24 hours after exercise, HR increased from 60 +/- 2 to 90 +/- 4 bpm (p = 0.001), but the reduction in SBP was essentially eliminated (116 +/- 5 to 113 +/- 5 mmHg).

Engelke, K. A.↗

Extreme ultraviolet observations of HZ 43 and the local H/He ratio with the Hopkins Ultraviolet Telescope

We present a spectrum of the hot DA white dwarf HZ 43 in the EUV, near the 504-A ionization edge of neutral helium, obtained with the Hopkins Ultraviolet Telescope (HUT) during the 1990 December Astro-1 mission. The interstellar column densities derived from this spectrum rule out the anomalous interstellar absorption model proposed by Heise et al.(1991), which required a greater column density of neutral helium than neutral hydrogen toward HZ 43 in order to explain the low EUV flux from HZ 43 reported by EXOSAT. Instead, we find the interstellar neutral H/He ratio toward HZ 43 to be consistent with the canonical cosmic abundance ratio of 10 or with the 11.6 +/- 1.0 ratio measured by HUT along the line of sight toward another DA white dwarf, G191-B2B. The HUT observations suggest that either there is a substantial calibration error in the EXOSAT spectroscopy of HZ 43, or otherwise undetected metals in the nominally pure hydrogen HZ 43 atmosphere suppress its flux between 150 and 300 A, or both.

Kimble, Randy A.↗

Peripheral Microvascular Responses to Whole-Body Tilting, G(z) Centrifugation, and Lower Body Negative Pressure Stresses in Humans

The response of the cutaneous microcirculation to orthostatic stress varies along the length of the body due to the interaction of central controls with regional responses to local blood pressure. We hypothesize that artificial orthostatic stresses such as Gz centrifugation and LBNP differ from whole-body tilting in terms of the distribution of microvascular blood flow. Cutaneous microvascular flows were measured by laser Doppler flowmetry at the neck, thigh, and leg of 15 normal subjects. Volunteers underwent stepwise head-up tilt (HUT) and short- and long-arm centrifugation protocols from supine control (0 Gz) to 0.2, 0.4, 0.6, 0.8, 1.0, 0.8, 0.6, 0.4, 0.2, and 0 Gz at the feet, for 30-s periods with 10-s transitions between levels. The same subjects underwent a corresponding supine LBNP protocol, up to 100 mmHg (in 20 mmHg increments) and back to zero pressure, which produced transmural pressure across blood vessels in the foot approximately equal to the HUT protocol. In general, application of all orthostatic stresses produced significant flow reductions in the lower body (p less than 0.05) and inconsistent changes in the neck. At low levels of each stress (0.4 Gz, 40 mmHg), LBNP generated the greatest relative reduction in flow in the lower body (-66.9+/-5.7%, thigh; -60.6 +/-5.7%, leg, mean +/- SE). HUT caused a less severe flow reduction than LBNP at the thigh and leg (-39.9 +/- 8.1% and -55.9+/-4.8%), while the effects induced by both forms of centrifugation were the least profound. Higher levels of each stress generally resulted in similar responses. These responses exhibit a consistent relationship to hypothesized changes in local microvascular transmural pressure, suggesting that myogenic and veno-arteriolar reflexes play a significant role in determining microvascular perfusion during orthostatic stress.

Breit, G. A.↗

Selective norepinephrine reuptake inhibition as a human model of orthostatic intolerance

BACKGROUND: Observations in patients with functional mutations of the norepinephrine transporter (NET) gene suggest that impaired norepinephrine uptake may contribute to idiopathic orthostatic intolerance. METHODS AND RESULTS: We studied the effect of the selective NET blocker reboxetine and placebo in a randomized, double-blind, crossover fashion on cardiovascular responses to cold pressor testing, handgrip testing, and a graded head-up tilt test (HUT) in 18 healthy subjects. In a subset, we determined isoproterenol and phenylephrine sensitivities. Subjects ingested 8 mg reboxetine or placebo 12 hours and 1 hour before testing. In the supine position, heart rate was 65+/-2 bpm with placebo and 71+/-3 bpm with reboxetine. At 75 degrees HUT, heart rate was 84+/-3 and 119+/-4 bpm with placebo and with reboxetine (P<0.0001). Mean arterial pressure was 85+/-2 with placebo and 91+/-2 mm Hg with reboxetine while supine (P<0.01) and 88+/-2 mm Hg and 90+/-3 mm Hg at 75 degrees HUT. Blood pressure responses to cold pressor and handgrip testing were attenuated with reboxetine. Reboxetine increased the sensitivity to the chronotropic effect of isoproterenol and the pressor effect of phenylephrine. Vasovagal reactions occurred in 9 subjects on placebo and in 1 subject on reboxetine. CONCLUSIONS: Selective NET blockade creates a phenotype that resembles idiopathic orthostatic intolerance. This observation supports the hypothesis that disordered norepinephrine uptake mechanisms can contribute to human cardiovascular disease. Our study also suggests that NET inhibition might be useful in preventing vasovagal reactions.

Non-NASA Center↗

Effects of 12 days exposure to simulated microgravity on central circulatory hemodynamics in the rhesus monkey

Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 degrees head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 degrees upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alternating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.

NASA Discipline Cardiopulmonary↗

Hypocapnia and cerebral hypoperfusion in orthostatic intolerance

BACKGROUND AND PURPOSE: Orthostatic and other stresses trigger tachycardia associated with symptoms of tremulousness, shortness of breath, dizziness, blurred vision, and, often, syncope. It has been suggested that paradoxical cerebral vasoconstriction during head-up tilt might be present in patients with orthostatic intolerance. We chose to study middle cerebral artery (MCA) blood flow velocity (BFV) and cerebral vasoregulation during tilt in patients with orthostatic intolerance (OI). METHODS: Beat-to-beat BFV from the MCA, heart rate, CO2, blood pressure (BP), and respiration were measured in 30 patients with OI (25 women and 5 men; age range, 21 to 44 years; mean age, 31.3+/-1.2 years) and 17 control subjects (13 women and 4 men; age range, 20 to 41 years; mean age, 30+/-1.6 years); ages were not statistically different. These indices were monitored during supine rest and head-up tilt (HUT). We compared spontaneous breathing and hyperventilation and evaluated the effect of CO2 rebreathing in these 2 positions. RESULTS: The OI group had higher supine heart rates (P<0.001) and cardiac outputs (P<0.01) than the control group. In response to HUT, OI patients underwent a greater heart rate increment (P<0.001) and greater reductions in pulse pressure (P<0.01) and CO2 (P<0.001), but total systemic resistance failed to show an increment. Among the cerebrovascular indices, all BFVs (systolic, diastolic, and mean) decreased significantly more, and cerebrovascular resistance (CVR) was increased in OI patients (P<0.01) compared with control subjects. In both groups, hyperventilation induced mild tachycardia (P<0.001), a significant reduction of BFV, and a significant increase of CVR associated with a fall in CO2. Hyperventilation during HUT reproduced hypocapnia, BFV reduction, and tachycardia and worsened symptoms of OI; these symptoms and indices were improved within 2 minutes of CO2 rebreathing. The relationships between CO2 and BFV and heart rate were well described by linear regressions, and the slope was not different between control subjects and patients with OI. CONCLUSIONS: Cerebral vasoconstriction occurs in OI during orthostasis, which is primarily due to hyperventilation, causing significant hypocapnia. Hypocapnia and symptoms of orthostatic hypertension are reversible by CO2 rebreathing.

Non-NASA Center↗

Effect of Sustained Human Centrifugation on Autonomic Cardiovascular and Vestibular Function

Repeated exposure to +Gz enhances human baroreflex responsiveness and improves tolerance to cardiovascular stress. However, both sustained exposure to +Gx and changes in otolith function resulting from the gravitational changes of space flight and parabolic flight may adversely affect autonomic cardiovascular function and orthostatic tolerance. HYPOTHESES: Baroreflex function and orthostatic tolerance are acutely improved by a single sustained (30 min) exposure to +3Gz but not +3Gx. Moreover, after 30 min of +3Gx, any changes that occur in autonomic cardiovascular function will relate commensurately to changes in otolith function. METHODS: Twenty-two healthy human subjects were first exposed to 5 min of +3 Gz centrifugation and then subsequently up to a total of30 min of either +3Gz (n = 15) or +3Gx (n = 7) centrifugation. Tests of autonomic cardiovascular function both before and after both types of centrifugation included: (a) power spectral determinations of beat-to-beat R-R intervals and arterial pressures; (b) carotid-cardiac baroreflex tests; ( c) Valsalva tests; and (d) 30-min head-up tilt (HUT) tests. Otolith function was assessed during centrifugation by the linear vestibulo-ocular reflex and both before and after centrifugation by measurements of ocular counter-rolling and dynamic posturography. RESULTS: All four +3Gz subjects who were intolerant to HUT before centrifugation became tolerant to HUT after centrifugation. The operational point of the carotid-cardiac baroreflex and the Valsalva-related baroreflex were also enhanced in the +3Gz group but not in the +3Gx group. No significant vestibular-autonomic relationships were detected, other than a significant vestibular-cerebrovascular interaction reported previously. CONCLUSIONS: A single, sustained exposure to +3 Gz centrifugation acutely improves baroreflex function and orthostatic tolerance whereas a similar exposure to +3 Gx centrifugation appears to have less effect.

Schlegel, Todd T.↗

Using Concurrent Cardiovascular Information to Augment Survival Time Data for Evaluating Orthostatic Tilt Test Performance

Head-up tilt (HUT) tests often are used in research to measure orthostatic intolerance (OI) (inability to appropriately control blood pressure while upright) in clinical populations and otherwise healthy individuals after interventions. Post-space flight orthostatic intolerance is a well-known phenomenon, and countermeasures to its development has been an active area of research at NASA. In the NASA HUT protocol, subjects lie horizontally on an automatic tilt table for baseline measurements before being raised to 80deg head-up tilt for a defined period of time or until signs or symptoms of presyncope ensues (light-headedness, nausea, dizziness, sweating, weakness or fainting). Multiple measures are collected to evaluate the cardiovascular system's ability to respond appropriately to the orthostatic challenge. However if the intended duration of the HUT is short, the ability to detect changes in OI due to an intervention or its prevention by a countermeasure may be limited by a small number of failures to permit comparisons based on survival time alone. Thus, the time-trajectory of the cardiovascular data becomes an important additional source of information. In particular, we will show how various measures of trajectory variability can effectively augment survival analysis for the assessment of OI in a joint model when high censoring rates are present.

Feiveson, Alan H.↗

Spacesuit and Mobility Performance Changes

The complex interactions between the human body and spacesuit lead to changes inmovement patterns and mobility performancesof the wearer. In general, factors including the geometric properties, such as shape and size, mechanical properties of the suit, and pressurization of the suit are known to be associated with altered movement patterns as compared to an unsuited human.However, their relative contributions have not been explicitly quantified from the mobility performance perspectives. The goal of this study wasthus to assessthe effects fromthe different types of mobility constraintconditions, namely by wearing either a 3D printed hard upper torso (HUT) assembly orfully pressurized spacesuit. The outcome was also compared against the unsuited motions. For this study, an xEMU (exploration Extravehicular Mobility Unit) suitwas considered, which is the next generation spacesuit developed by NASA. In each test condition, the subject was asked to move the arm and hand as prescribedfor different task types, and the corresponding body segment locations were recordedusing a 3D motion capture system. The following three tasks were performedand analyzed: 1) Outward one-handed reaches:the subject in a standing pose made sweeping motions with the extended right arm from the extreme end-to-end positions, including side-to-side at different elevations and top-to-bottom at different azimuths. 2) Outward two-handed reaches:similarto the previous task, howeverthe subject kept the hands together during the motions in order to assessthe areas that can be reached by both hands. 3) Inward one-handed reaches:the subject made right-hand reach motions to the surface of the HUT.The hand traces collected from each task were modeled by a template shape parametrically deformed with a radial basis function. This process enabled foran abstraction of the hand traces into a smooth surface envelope representing the maximally reachable area of the test subject, of which the shapes and sizes were compared across the different test conditions. The preliminary analysis has shown that theoverall size of reachenvelopes decreases in a pressurized suit compared to 3D printed mockup HUT and unsuited conditions. The specific shape of the envelopes, which were determined by the reachable and unreachable zones, alsovary with the testconditions, and the differences werepronounced with the inward reaches to the HUT surface. The latter observation ispotentially relatedto the increased demandfor shoulder and elbow flexions.Overcomingthe resistance from the pressurizedsoft goods and mechanical constraints of the shoulder assemblywas seen to be associated with the difference in motion patterns between the suited and unsuited conditions. Overall, the information quantified from this study is expected to provide structured metrics for spacesuit mobility, which can improve design optimization and human-system integration.

K Han Kim↗

Comparative orthostatic responses - Standing vs. head-up tilt

In both physiologic and clinical studies, standing is often loosely equated with head-up tilt (HUT) although the cardiovascular effects of these variants of orthostasis have not been formally compared, except for heart rate. The effects of HUT and standing were measured noninvasively in male volunteers satisfying identical criteria for age and normal status. In both postures, there were significant increases in heart rate, pre-ejection period, isovolumic contraction time, and the ratio of pre-ejection to ejection period, and significant decreases in ejection period and ejection time index. All of these changes were greater for standing than for tilt. Pulse transmission time changed significantly (-14%) only with tilt. We conclude that head-up tilt and standing are rather comparable but not physiologically identical forms of orthostasis.

Spodick, D. H.↗

Effect of posture on arterial baroreflex control of heart rate in humans

The effects of blood-volume redistribution induced by postural changes on baroreflex activity are investigated. The central blood volume and baroreceptor functions of ten males between 23-51 years old were examined while they were in the head-up tilt (HUT), head-down tilt (HDT), and supine positions. It is observed that during HDT at 15 deg the pulse interval over the first five cardiac cycles following neck suction onset is 51 + or - 18 ms longer, at 30 deg it is 61 + or - 20 ms longer, and at 45 deg it is 74 + or - 35 ms longer than at supine; during HUT at 15 deg the pulse interval is 25 + or - 9 ms shorter than when supine, but for the 30 and 45 deg there is no significant difference in pulse interval detected. The data reveal that posture does modify arterial baroreflex control of heart rate.

Harrison, M. H.↗

Evidence for shock-heated gas in the Hopkins Ultraviolet Telescope spectrum of NGC 1068

The paper presents FUV spectra of the NGC 1068 Seyfert 2 galaxy, obtained with the Hopkins Ultraviolet Telescope (HUT) during the flight of Astro-1 aboard the Space Shuttle Columbia in December 1990, revealing moderately strong C III 977-A and N III 991-A emission lines, which have never been seen before in spectra of AGNs. It is noted that the emission-line spectrum of NGC 1068 qualitatively resemble the HUT spectrum of a radiative shock in the Cygnus Loop supernova remnant (Blair et al., 1991), suggesting that shock heating may contribute significantly to the line emission.

Kriss, Gerard A.↗

Spectroscopy of a Balmer-dominated filament in the Cygnus Loop with the Hopkins Ultraviolet Telescope

A fair UV spectrum of a nonradiative filament in the Cygnus Loop covering the wavelength range 830-1860 A at 3.5-A resolution was obtained using the Hopkins Ultraviolet Telescope (HUT) on the Astro-1 space shuttle mission. Nonradiative shock models which include a more sophisticated treatment of Lyman line transfer are calculated. It is found that the HUT spectrum can be explained in terms of a shock with velocity 175-185 km/s propagating into a low-density medium. This shock velocity can be reconciled with the 135-km/s width of the broad component of H-alpha in this filament if equilibration of the postshock electron and ion temperatures proceeds much more rapidly than Coulomb equilibration time scales. The time required for a 180-km/s shock to develop a partial recombination zone is short, about 200 yr if n is approximately equal to 2/cu cm. This suggests that the shock is decelerating as it encounters denser material. The current analysis patently favors rapid equilibration of electrons and ions behind the shock.

Long, Knox S.↗

Extreme ultraviolet observations of G191-B2B and the local interstellar medium with the Hopkins Ultraviolet Telescope

During the Astro-l mission in 1990 December, the Hopkins Ultraviolet Telescope (HUT) was used to observe the extreme ultraviolet spectrum (415-912 A) of the hot DA white dwarf GI91-B2B. Absorption by neutral helium shortward of the 504 A He I absorption edge is clearly detected in the raw spectrum. Model fits to the observed spectrum require interstellar neutral helium and neutral hydrogen column densities of 1.45 +/- 0.065 x 10 exp 17/sq cm and 1.69 +/- 0.12 x 10 exp 18/sq cm, respectively. Comparison of the neutral columns yields a direct assessment of the ionization state of the local interstellar cloud surrounding the Sun. The neutral hydrogen to helium ratio of 11.6 +/- 1.0 observed by HUT strongly contradicts the widespread view that hydrogen is much more ionized than helium in the local interstellar medium, a view which has motivated some exotic theoretical explanations for the supposed high ionization.

Kimble, Randy A.↗