At least 55 records · Page 3

Radiative Heat Transport and Optical Characterization of High Temperature Molten Salts

The goal of this project was to advance the field of molten fluoride radiative heat transfer (RHT), through optical property measurements, heat transfer loop construction and operation, and computational fluid dynamics simulations. The following outcomes have been accomplished. A comprehensive review has been conducted to compile all available RHT-relevant optical absorption data for molten fluorides. The various measurement methods have also been compiled and critiqued. Thermal emission measurement methods have been refined and documented. A unique thermal emissivity measurement facility has been constructed and used to measure the emissivity of flowing FLiBe-exposed SS316 samples. A slight increase has been observed in the emissivity compared to unexposed SS316. A dual reflectance-emission setup was partially demonstrated for the purpose of molten fluoride absorption measurement. Preliminary infrared edge data for FLiNaK was obtained. A visible near-infrared (NIR) measurement setup has been constructed and will be used to measure absorption of corrosion products in FLiBe. A new multi-band thermal radiation method using blackbody-weighted spectral bands for the absorption-coefficient was deployed to investigate the thermal performance of the UW Natural Circulation FLiBe Loop under various power levels and operating conditions. The results showed an increasing and decreasing trend in the overall heat transfer with optical thickness with a maximum at optical thickness τ D ≈Ο(1). A forced convection FLiBe loop was constructed for the purpose of studying corrosion and thermal hydraulic phenomena. A vertical cantilever pump is used to achieve up to 5 gpm and 5 m/s flow velocity in hot and cold test sections. A methodology has been established for modeling radiative heat transfer (RHT) in molten salt coolants for the purpose of quantifying the contribution of thermal radiation in conditions relevant to FHR or MSR systems. The comparison between the results obtained for forced and mixed convection showed that in the studied ranges of optical thickness, the maximum effect of RHT on overall heat transfer was 60% improvement observed at z/D = 250 for forced convection; whereas for mixed convection, that value was higher at 170% observed at z/D = 30. The highest effect of RHT on the overall energy distribution was observed at τ D ≈3.4. Negligible effect (<20%) was observed above τ D =18 and below τ D ≈0.002. A CFD code-to-code comparison was conducted using COMSOL Multiphysics at UW-Madison and STAR-CCM at MIT, for a forced and mixed convection laminar flow for a grey medium in a vertical heated using both COMSOL Multiphysics at UW-Madison and STAR-CCM at MIT. The relative error was the largest at τ D =40 for the radiative heat flux, bulk temperature, and Nusselt number. On the other hand, the relative error was the least at τ D =0.002 for the conductive heat flux, bulk temperature, and Nusselt number.

Anderson, Mark↗

HERO WEC - Bills of Materials: WEC, RO System, and Submersible Pump

This submission includes detailed Bills of Materials for the NREL-designed and -built Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC), as well as the reverse osmosis assembly and submersible pump that are used in the HERO WEC. The WEC file is specific to the components and sub-components that are included on the in-water buoy portion of the WEC. The RO file is specific to the components and sub-components that are included on the reverse osmosis module that is used for both the hydraulic and electric configuration. The submersible pumps file is specific to the components and sub-components that are included on the submersible pump module that is used feed the reverse osmosis module when the HERO WEC is in the electric configuration. In addition to this submission, an additional submission available for the WEC model itself, including the power electronics enclosure, and reverse osmosis assembly that is needed to supply water in the electric submission. A link is provided below. More details on this project including data, CAD drawings, etc. can be found in the HERO-WEC main page link below. This data set has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM019

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM019 in accordance with the approved test plan (Dixon, 2020). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. This testing consisted of a step-drawdown test to determine well performance properties, a constant pumping rate aquifer test to determine aquifer hydraulic properties, and a post-test aquifer recovery monitoring period also used to estimate aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The specific capacity of RWM019 was determined to be approximately 2.6 gpm/ft of drawdown based on the final step of the step-drawdown test. Well efficiency was inversely related to pumping rate and decreased from 87% to 81% over a pumping range of approximately 49 to 79 gpm. The aquifer head loss coefficient was determined to be 2.3 ft/ft 3 /min and the well loss coefficient was determined to be 0.05 min 2 /ft 5 .

42 ENGINEERING↗

Distributed Acoustic Sensing as a Distributed Hydraulic Sensor in Fractured Bedrock

Distributed acoustic sensing (DAS) was originally intended to measure oscillatory strain at frequencies of 1 Hz or more on a fiber optic cable. Recently, measurements at much lower frequencies have opened the possibility of using DAS as a dynamic strain sensor in boreholes. A fiber optic cable mechanically coupled to a geologic formation will strain in response to hydraulic stresses in pores and fractures. A DAS interrogator can measure dynamic strain in the borehole, which can be related to fluid pressure through the mechanical compliance properties of the formation. Because DAS makes distributed measurements, it is capable of both locating hydraulically active features and quantifying the fluid pressure in the formation. We present field experiments in which a fiber optic cable was mechanically coupled to two crystalline rock boreholes. The formation was stressed hydraulically at another well using alternating injection and pumping. The DAS instrument measured oscillating strain at the location of a fracture zone known to be hydraulically active. Rock displacements of less than 1 nm were measured. Laboratory experiments confirm that displacement is measured correctly. These results suggest that fiber optic cable embedded in geologic formations may be used to map hydraulic connections in three-dimensional fracture networks. A great advantage of this approach is that strain, an indirect measure of hydraulic stress, can be measured without beforehand knowledge of flowing fractures that intersect boreholes. The technology has obvious applications in water resources, geothermal energy, CO 2 sequestration, and remediation of groundwater in fractured bedrock.

54 ENVIRONMENTAL SCIENCES↗

Power Analysis of an ePump Applied to the Linear Functions of an Agricultural Planter

Like many other industries, the agricultural industry has recently ex-perienced pressure to reduce vehicle emissions while improving productivity. Electric actuation is perceived as a viable solution to replace or augment hydrau-lic and mechanical actuation. However, electrification presents challenges with regards to linear functions, where hydraulic actuators have advantages in terms of compactness, tolerance to contamination and resistance to shocks. A combined electro-hydraulic actuation architecture can leverage the benefits of both electric and hydraulic actuation, while reducing the drawbacks of both approaches. This work investigates the potential of a centralized electric driven pump (ePump) system powering the pressure-controlled linear functions of an agricul-tural planter, with the goal of improving the operating point of the main supply pump. In this application, the rotary functions are hydraulically actuated, alt-hough such a solution could be applied also to electric rotary actuation. This is accomplished by setting the ePump to boost the pressure supplied by the tractor to the level required by the linear functions. An accumulator is used to stabilize the flow requirements of the linear functions, and control the pressure supplied to the actuators. Two control schemes are proposed for the regulation of the ac-cumulator pressure, one favoring an efficient operating point for the ePump, the other favoring stable steady state operation. A simulation model of the baseline system and proposed system is developed and validated using experimental data from a full-scale machine. Using the vali-dated simulation, both control architectures are then evaluated for improvement in system power consumption and dynamic requirements on the ePump to assess their effectiveness. Both systems demonstrate significant improvement in power consumption over the baseline system, with the best solution improving effi-ciency by 64%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM001R

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM001R in accordance with the approved test plan (Dixon, 2024). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. This testing consisted of two step-drawdown tests to determine well performance properties and two constant pumping rate aquifer tests with recovery periods to determine aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The results of the step-drawdown testing are presented in Tables ES1 and ES2 whereas the results of the constant pumping rate testing are presented in Table ES3. The average specific capacity of RWM001R operating at pump capacity (~54 gpm) was 2.2 gpm/ft using data from the final step of both tests. The average well efficiency determined from both step-drawdown tests was 56% using data from the final step of both tests. For both step-drawdown tests, well efficiency was inversely related to the pumping rate with the average efficiency decreasing from approximately 79% to 56%. Aquifer head loss coefficients from both tests were comparable (Table ES2).

54 ENVIRONMENTAL SCIENCES↗

Electrical Resistivity Tomography Monitoring of In Situ Soil Flushing at the Hanford 100-K East Area: 100KE Soil Flushing Monitoring

Former operations in the 100-KE Area at the Hanford Site resulted in vadose zone hexavalent chromium that provides a source of groundwater contamination. Previous efforts to remediate vadose zone chromium involved excavation and offsite treatment of contaminated soils. Although much of the chromium was removed, contamination still exists in native soil between the water table and the bottom of the pit, which has since been backfilled. In-situ soil flushing was tested at the 100-KE Area to accelerate the removal of the remaining hexavalent chromium in the vadose zone. Soil flushing works by applying clean flush water at the surface, which mobilizes and transports chromium as it migrates downward to the water table. Once the chromium reaches the water table, it is hydraulically contained, extracted, and treated through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. Therefore, performance monitoring requires and understanding of flush water migration through the vadose zone. It is challenging to comprehensively assess soil flushing performance via borehole access due to the limited volume of investigation afforded by a given wellbore. As an alternative, 3D time-lapse electrical resistivity tomography (ERT) was tested as a method of monitoring the distribution of flush water over time within the vadose zone. ERT is a method of imaging the bulk electrical conductivity of the subsurface, which is highly dependent on water saturation levels in unconsolidated and unsaturated sediments. Thus, the timing and location of changes in bulk conductivity caused by soil flushing can be used to infer flush water migration pathways. In this report we present results of 3D time-lapse ERT imaging during two separate soil flushing campaigns conducted during the spring and summer months of 2022 and 2023. Results show generally that: 1) Pit backfill materials appear to nominally have larger permeability than native soils. Consequently, the boundary between pit backfill and native soil had a significant impact on flush water migration, causing some flush water to migrate along the pit boundary to the bottom of the pit. 2) Non-uniform flows, likely caused by variations in hydrogeologic properties, developed in the pit backfill materials, resulting in uneven flush water distribution on the southern margin of the soil flushing zone. 3) Redistribution of water at the interface between backfill materials and Hanford formation materials likely facilitated elevated and uniform distribution of flush water within native soils beneath the deeper parts of the pit boundary beneath the center of the flush zone, which presumably overlie soils with elevated chromium contamination. These areas appear to have been infiltrated by higher volumes of flush water than the northern and southern margins of the flush zone. 4) In comparison to 2022, high flush water application rates significantly improved flush water distribution throughout the target flushing zone. 5) Imaging resolution was limited to a depth of approximate 20 meters below the land surface, due primarily to limitations on the lateral extent of the surface ERT array. The ~10 m region of the vadose zone between approximately 130 meters elevation and the water table at approximately 120 meters elevation was unresolved.

100 Area↗

Hydropower Biological Evaluation Toolset (HBET) Version 3.0: User Guide

The Hydropower Biological Evaluation Tools (HBET) software package, developed by Pacific Northwest National Laboratory (PNNL), is designed to assemble, organize, and process data collected by Sensor Fish and live fish. HBET enable users to characterize the hydraulic conditions of hydropower structures and estimate fish injury and mortality rates from various stressors. Future updates of the software may support other technologies, such as bead tracking in physical models and computational fluid dynamics. The HBET program can be customized to analyze different hydraulic applications, including turbines, spillways, weirs, pumped storage, and other user-defined functions, and therefore, help researchers, turbine designers, hydropower operators, and regulators better evaluate hydropower structures regarding their environmental sustainability and cost-effectiveness. Added content to the user guide about the new feature for predicting absolute injury rates.

13 HYDRO ENERGY↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

A compact design for an electric driven hydraulic gear machine capable of multiple quadrant operation

This paper presents an innovative design of an integrated electro-hydraulic (EH) flow generation unit able to operate in multiple quadrants. The proposed unit is composed of a hydraulic machine which can operate in either pumping or motoring mode, and an electric machine, which can operate as electric motor or generator. The adopted morphological integration of the two unit fulfills the goals of maximizing compactness, power to weight ratio, energy efficiency and quietness. Furthermore, the design results from a numerical optimization procedure that includes detailed simulation of both the electric machine and the hydraulic machine, using simulation tools previously developed by the authors, but combined for the first time in this work. After describing the optimization procedure, the paper focuses on the design integration aspects of the novel unit. A 9 kW prototype of the integrated unit was also fabricated and tested to verify its performance. Tests results show a measured overall energy efficiency up to 69%, demonstrating the potentials of the proposed concept, despite some limitations present in the first prototypes which could be addressed in future design refinements.

42 ENGINEERING↗

Evaluating the Feasibility of Using Strain Measured During Sinusoidal Rate Pumping Tests to Characterize an Aquifer

Pumping tests with sinusoidal variation in pumping rate have been proposed as a method for improving aquifer characterization. These tests can interrogate a larger aquifer volume than slug tests and they can be more sensitive to small variations in drawdown. Current methods of using sinusoidal variations of rate are based on measuring pressure signals from the reservoir or aquifer, which requires access to monitoring wells. An alternative approach has been developed that measures the strain in the vadose zone instead of pressure in the reservoir. An instrument has been developed at Clemson University that can measure small strains using optical fiber sensors, and we propose that it can be used to measure strain during sinusoidal pumping tests. The objective of this project is to evaluate the feasibility of measuring and interpreting the vertical strain in the vadose zone generated during a sinusoidal rate pumping tests to estimate aquifer and/or overburden properties. Pumping tests were performed at a site with a water table at 9 m and saturated saprolite from 9 to 30m depth. Sinusoidal pumping tests in the saprolite used different pumping amplitudes and periods while pressure was measured at three piezometers and vertical strain was measured in the vadose zone from 1 to 7 m depth. The delay time of the pressure increased linearly with distance, and it increased with the square root of the period, while the amplitude of the pressure decreased with distance and increased with amplitude. Vertical strain in the vadose zone varied with the same period as the pumping rate and the delay times were similar to those for pressures measured at similar radial distances. Delay times for the strain increased with an increasing propagation of the strain field. The hydraulic diffusivity was estimated using delay times for pressure and strain, and the results were compared with the values estimated from a constant-rate pumping test. The hydraulic diffusivity from the constant rate test was 0.039 m2/sec, whereas it was 0.053 (±0.05) m2/sec and 0.035 (±0.03) m2/sec from the pressure data and 0.08 (±0.022) m2/sec and 0.035 (±0.001) m2/sec from the strain data from sinusoidal tests of various periods and amplitudes. There is no statistical difference among these values. This study indicates that strain measurements in the vadose zone can be used to estimate aquifer properties during sinusoidal pumping tests.

Blais, Riley↗

A hybrid surrogate modeling framework for the Digital Twin of a Fluoride-salt-cooled High-temperature Reactor (FHR)

While nuclear energy is a non-greenhouse-gas emitting energy source, expensive operational costs due to the high-level of safety requirements decreases their competitiveness in the sustainable energy market. Advanced reactor concepts paired with Digital Twins aim to increase the commercialization gains of nuclear energy by reducing operational costs, increasing reactor reliability and enhancing power generation. To support Digital Twin tasks such as real-time autonomous control, proactive maintenance monitoring or optimizing power demand operations, a fast and accurate virtual representation of the Nuclear Power Plant (NPP) is required. The computational cost of high-fidelity, physics-based models are unsuitable for real-time analysis or scalability. Here, in this work, a hybrid surrogate modeling framework is developed fora Fluoride-salt-cooled High-temperature Reactor (FHR) that leverages physics-inspired models for key reactor components and uses data-driven methods for rapid system state space prediction. The Xenon reactivity feedback model is integrated to inform the surrogate model about the reactor core and the homologous pump theory model is the basis for representing pump degradation. Using a detailed, two dimensional thermal hydraulics model to generate data on the FHR, we train a network of Vectorized Autoregressive Moving-Average with eXogenous input (VARMAX) models to predict the remaining state values. The result is a surrogate model that provides a detailed reactor state representation of 41 system states and a pump degradation analysis. The framework is applied to Load Follows profiles, yielding high accuracy and a speedup that is more than 4000x faster compared to the higher- fidelity thermal hydraulics model, enabling real-time operational intelligence and applications in long horizon predictions. While the surrogate model framework is demonstrated for the particular case of FHR, the hybrid physical/data-driven modeling approach including the network of surrogates and the underlying modularity has the potential to be applied to other physical asset systems.

Digital Twins↗

HERO WEC V1 Upgrades - SolidWorks Models (WEC, RO System, and Submersible Pump Housing)

The attached zip files include SolidWorks pack-and-go assemblies of NREL's HERO WEC (hydraulic and electric reverse osmosis wave energy converter), the reverse osmosis (RO) assembly, and the submersible pump assembly that is used to provide flow to the RO assembly in the electric configuration. These 3 models were upgraded in 2023 from their baseline models. The HERO WEC model does not include all aspects of the design (i.e. RO system, electrical enclosure, hose, cable), it only includes the WEC and PTO (power take-off) design. This model supersedes the old MHKDR model submission, linked below. The RO model file includes a SolidWorks (version 2023) pack-and-go assembly of the RO assembly that was used for HERO WEC as it was upgraded in 2023. This model ONLY includes the RO assembly and not the WEC, hoses, etc. The submersible pump enclosure model includes a SolidWorks (version 2023) pack-and-go assembly of the submersible pump assembly that is used to provide flow to the RO assembly in the electric configuration HERO WECas it was upgraded in 2023. This model ONLY includes the submersible pump assembly and not the WEC, RO system, hoses, etc. This work has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

Conceptual Design of a Pumped Water Capsule for TREAT

This study performed mechanical design, thermal hydraulic, and fuel performance investigations to determine whether an existing large water capsule design could be modified to create forced convection boundary conditions on nuclear fuel specimens in the Transient Reactor Test facility. This concept was found to be viable and offers several advantages compared to a static water environment for a variety of transient power shape categories. The pumped capsule is not foreseen to be superior to a past concept for a larger water loop, but the pumped capsule approach is recommended for further engineering and deployment based on its high cost-to-value ratio primarily as a stop gap capability until a larger water loop can be realized.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗