Search NASASearch

SEARCH · Search NASA

Results for “Hacking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Exploring the Performance and Reliability of Screen-Printable Fire-Through Copper Paste on PERC Solar Cells

In this work, we present the performance and reliability of a fire-through copper (Cu) paste which has been screen printed on c-Si solar cell with passivated emitter rear contact (PERC). The Cu paste is fired through silicon nitride (SiN) anti-reflection coating at a peak temperature of 630 degrees C . SEM images of the Cu paste show a Cu core with ~200 nm oxide shell around the particles. This conductive oxide layer acts as a diffusion barrier between Cu and Si and prevents the degradation of cell performance during accelerated aging conditions. An efficiency of 19.250% has been achieved with Voc=654mV,FF= 76.68%, Jsc=38.40 m.A/cm 2 for champion PERC cells. Accelerated testing of the PERC mini-modules in damp heat chamber with 85 degrees C and 85% humidity have demonstrated that the devices are operational even after 1,500 hours. Devices with screen printed Ag contacts on the front side have been studied in parallel to the Cu contacts for comparison.

copper

Modeling a High-Temperature Electrochemically Driven Water-Gas-Shift Process Using a Mixed-Conducting Membrane without External Electrical Power

This paper develops a model to predict and interpret the performance of an elevated-temperature, electrochemical, membrane-assisted, water-gas-shift process. The process uses separated feed streams of H 2 O and CO to produce separated streams of H 2 and CO 2 , without an external electrical power source. The dense ceramic membrane is mixed ionic-electronic-conducting (MIEC) gadolinium-doped ceria (GDC) and the porous composite electrodes are Ni-YSZ. At elevated temperature, GDC conducts both oxygen ions and small polarons. The present process uses chemical potential to drive the process. Electrochemical oxidation of CO proceeds within the composite anode and H 2 O reduction proceeds within the composite cathode. At high temperature (e.g., T > 700 °C), GDC has significant electronic leakage in the form of a reduced-cerium small polaron, which supports the charge-transfer reactions. In a typical electrolyzer or fuel cell, this leakage is significantly problematic. However, the present process depends on the leakage current to complete the electrochemical circuit. Model development and validation is based on measured material properties and reactor performance. Potential applications include using CO-rich blast-furnace off gases in steel processing, producing separated streams of H 2 and CO 2 .

Zhu, Huayang

Performance Testing of Moving Bed Gasifier Using Biomass and Waste Fuels to Generate Low-Cost Clean Hydrogen

Our need for hydrogen is growing as the world transitions toward a low-carbon future. Hydrogen provides long-term energy storage for grid stability in a solar- and wind-dominated power market and can be used to decarbonize other sectors. One promising process for generating low-cost hydrogen that produces net-negative carbon is to gasify biomass with a mixture of legacy coal wastes, waste plastics, and other wastes with carbon capture. Use of waste fuels lowers costs and diverts waste from landfills. EPRI is leading a project, funded by the U.S. Department of Energy, to conduct performance testing of modular, moving-bed gasification for the generation of low-cost, clean hydrogen from biomass mixed with legacy coal waste, waste plastic, and/or refuse derived fuels. The work scope includes preparation of multiple pellet feedstocks using biomass (both woody biomass and corn stover) with a mixture of legacy coal waste, plastic waste (wire insulation), and refuse-derived fuel (RDF). These pelletized feedstocks are being qualified based on performance testing of selected fuel blend compositions in updraft moving-bed gasifier located in Sardinia, Italy. Testing is being conducted to obtain relevant data to advance the modular design of the moving-bed gasification process, and successfully use these feedstocks to produce a high hydrogen content raw syngas that can be shifted to produce clean hydrogen. Testing results will be used to determine the effects of the various fuels on feedstock development, the resulting products (i.e., syngas compositions, organic condensate production, and ash characteristics), and impacts on gasifier operations.

08 HYDROGEN

Front End Engineering Design Study on Gasification of Coal and Biomass to Generate Carbon- Free Electric Power and Hydrogen

A 2nd Phase Front End Engineering Design study of a gasification plant concept to co-produce electric power and hydrogen with net-negative CO2 emissions is being completed under the U.S. Department of Energy’s (DOE’s) 21st Century Power Plants initiative, whose goal is to advance innovative power plant concepts that are capable of flexible, net-zero carbon emission operations while producing cost-effective hydrogen to support economy-wide decarbonization goals. The proposed standalone plant would be constructed in Nebraska, USA. The specified design feedstock is a hybrid blend of Powder River Basin (PRB) subbituminous coal from Wyoming and local Nebraska biomass (corn stover), 50% each by weight (dry basis). Other potential feedstocks, including woody biomass (eastern red cedar) and waste plastic (auto shredder residue) were evaluated as alternates. The process block comprises a high-pressure, oxygen-blown fluidized bed gasifier coupled with water-gas shift, Selexol process for acid gas (H2S and CO2) removal, and pressure-swing adsorption (PSA) to yield 8,500 kg/h of high-purity hydrogen. Off-gas from the PSA unit is used in a gas turbine combined cycle plant (the power block) to supply 50 MWe net electric power to the grid. Overall thermal efficiency of the plant is 50% (HHV) with net atmospheric CO2 removal at a rate of 32 t/h. Design activities necessary to provide input to the current front-end engineering design (FEED) study, including, site selection, gasifier technology selection, investment case preparation, and the development of the Environmental Information Volume (EIV) for the host site, have been completed. These, as well as the current FEED activities, are described in this presentation.

gasification, biomass, coal, hydrogen, power gener

2024 Photovoltaic Inverter Reliability Workshop Summary Report & Proceedings

The National Renewable Energy Laboratory (NREL) organized the 2024 Photovoltaic Inverter Reliability Workshop on April 11-12, 2024, hosted at NREL's South Table Mountain campus in Golden, Colorado. The workshop was organized around seven key topics, including the present state of inverter reliability; solutions for reliability challenges; life cycle cost and ownership issues; testing, standards, performance, and reliability metrics; data reporting, analytics, and sharing; and the future of PV inverter reliability research. Participants included inverter manufacturers, national laboratory researchers, academics, independent testing laboratories, and more. Over the course of the two-day workshop, attendees arrived at several key priorities and conclusions. This report summarizes these conclusions and then collects presentations from the workshop into a record of the workshop's proceedings.

14 SOLAR ENERGY

Performance Testing of a Moving-Bed Gasifier Using Coal, Biomass, and Waste Plastic Blends with Washed and Unwashed Legacy Coals and Other Waste Fuels to Generate White Hydrogen

The objective of this effort, primarily funded by the United States Department of Energy (DOE), and led by the Electric Power Research Institute, Inc. (EPRI), with support by Hamilton Maurer International (HMI) and Sotacarbo S.p.A. (Sotacarbo), has been to qualify coal, biomass, and plastic waste blends based on performance testing of selected fuel pellet compositions in a pilot-scale updraft moving-bed (UDMB) gasifier. The testing provided relevant data to advance the commercial-scale design of the moving-bed gasifier to be able to successfully use these feedstocks to produce hydrogen. In particular, the effects of waste plastics on feedstock development (i.e., blending and pelletizing) and the resulting products (i.e., syngas compositions, organic condensate production, and ash characteristics) are the focus. The gasifier used for testing is HMI’s moving-bed gasifier, which has been proven capable of gasifying nearly all coal ranks. It has also shown the ability in prior testing work to gasify wood chips (biomass). However, mixtures of these fuels with plastic wastes have not been prepared and gasified together. The three feedstocks were densified and pelletized by California Pellet Mill (CPM) to meet the feedstock size required by Sotacarbo’s 30mm ID UDMB gasifier, under contract to HMI. The technical tasks and results from this two-year research project included: (1) Feed Procurement and Preparation: Nine different tri-fuel pellets were prepared from varying compositions of fresh mined PRB coal, corn stover biomass, and car fluff waste plastics. Tri-fuel pellets were produced by CPM and shipped to Sotacarbo’s test facility in Carbonia, Sardinia, Italy. (2) Test Plan Development: A test plan was created to define the test runs to be performed. The test plan detailed the different UDMB gasification tests to be performed in Sotacarbo’s 12-inch ID pilot scale gasifier, the process monitoring instrumentation used, and the extractive samples recovered for analysis of the total gasification process mass and energy balance. (3) Gasifier Testing: Nine different gasification runs were performed in the pilot-scale gasifier at Sotacarbo using nine different fuel feedstock compositions generated from varying mixtures of PRB coal, biomass, and plastic wastes. The testing generated performance data on gasification reaction efficiency and performance, yielding relevant data for models used to scale up the gasifier design. This task also included work to refurbish and reassemble the pilot gasifier at Sotacarbo and perform a baseline 100% PRB coal run. (4) Data Analysis and Reporting: Review of the data, determination of figures of merit, and interpretation of the results are reported in the project’s final report, published in March 2024. The results show that all tri-fuel pellets gasified well and maintained structural integrity throughout the gasification process. The syngas generated can be shifted to hydrogen by using commercial syngas shifting technologies. (5) High Fidelity computational fluid dynamics (CFD) Simulation: The National Energy Technology Laboratory (NETL) team performed CFD simulations of the UDMB gasifier for two of the tri-fuel pellets gasified in Sotacarbo’s pilot scale gasifier. The kinetic mechanisms for the pyrolysis of each constituent, PRB coal, corn stover biomass, and waste plastics are based on thermogravimetric analysis performed by Sotacarbo. The gasification model was validated by comparing the predicted syngas composition at the exit of the gasifier with the measured syngas composition. In addition, the reactor’s measured internal temperature profile agreed well with the predicted internal reactor temperature profile. These results validate that the model can be used to predict the performance of the updraft moving bed gasifier for different feedstocks and operating conditions. This paper summarizes the results of the completed work in which the pelletizing procedure was validated to ensure the viability of the tri-fuel pellets for the gasification runs performed at Sotacarbo’s 30 mm UDMB gasifier. The gasification performance data from this series of nine runs will enable modeling of a full-scale HMI industrial scale gasifier supporting both combined heat and power, and Hydrogen production from coal (both fresh mined and legacy) combined with various biomass and waste plastics. Additionally, plans and progress on a follow-up project, being executed by the same project team, will be presented. In this project, a total of twenty (20) different feedstocks are being prepared from varying compositions of biomass (both woody biomass and corn stover) with a mixture of legacy coal waste, plastic waste, and refuse-derived fuel (RDF). The testing will provide information on gasification reaction efficiency/performance, yielding relevant data for models used to scale up the gasifier design to 50 megawatt electric (MWe) (equivalent hydrogen production). Tests will also be performed on a bench-scale fluidized-bed gasifier for comparison purposes. The results of this testing will be used to specify the range of feedstock blends that can be successfully gasified as well as quantify gasifier outputs based on specific blends.

08 HYDROGEN

Photovoltaic Cable Jackets: A Comparison of Representative Products Using Combined-Accelerated Stress Testing [Slides]

Photovoltaic (PV) cables facilitate the distribution of electricity collected from modules to the energy grid. Durable cabling enables continuous operation of PV installations, whereas cables with a lifetime less than the modules must be replaced - reducing electricity generation and adding to the operating expense. This study primarily focusses on the aging of the key cable types using the combined-accelerated stress testing (C-AST) protocol. Representative cables for utility, building, and control/auxiliary applications were examined. Cable jacket materials examined include: polyolefin, polyethylene, polyamide, poly(vinyl chloride), chlorinated polyethylene, thermoplastic elastomer, and ethylene propylene diene monomer rubber. Specimen characterizations applied include: optical microscopy, mechanical profilometry, instrumented indentation, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), Fourier-transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), and differential scanning calorimetry (DSC). A variety of performance and durability characteristics were observed, depending on the base material, polymer formulation, and jacket color. The results from C-AST are analyzed and discussed relative to a recent industry survey on electronic balance of system components in addition to a recent study where similar cables were aged using steady state ultraviolet weathering (International Electrotechnical Commission Technical Specification 62788-7-2). Recommendations are made for the screening, industry qualification, and service life prediction of PV cable jackets.

24 POWER TRANSMISSION AND DISTRIBUTION

Diagnosis of PV Cell Antireflective Coating Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable, legacy aluminum back surface field (Al-BSF) cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60deg C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission (IEC) Technical Specification 62804-1; 70 deg C/70% RH for 200 h; and 85 deg C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage (I-V) curve tracing. Final characterizations included: Suns-Voc; spatial mapping of external quantum efficiency (EQE); high-resolution photoluminescence (PL), EL, and dark lock-in thermography (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline-corrosion and -delamination as well as other concurrent degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY

Testing of Prototype PV Modules (CRADA Final Report)

The American-Made Solar Prize is a prize competition from the U.S. Department of Energy (DOE) that is designed to revitalize U.S. solar manufacturing. The competition aims to support the growth of U.S. solar manufacturing and reenergize American energy innovation by tapping into Americans’ competitive spirit and the nation's unparalleled innovation ecosystem, leveraging national labs, incubators, facilities, and more. Finalists have been chosen based on the work they intend to do with a manufacturing partner to advance their innovation to market. NLR will provide technical advisement to assist participants in demonstrating the full potential of their product.

14 SOLAR ENERGY

Degradation Mode Identification by Photocarrier Lifetime Spectroscopy on Devices and Test Structures

In this presentation, I examine the basic concepts of the device physics that can be used to distinguish various degradation and recovery modes on a cell level. The known degradation modes (bulk LeTID and LID, UVID, etc.) are due to defects and impurities that cause the photocarrier recombination according to Shockley-Reed-Hall (SRH) statistics. The SRH recombination rate strongly depends on the balance of electron and hole capture rates into the defects, which in turn, are governed by their local concentrations. The strongest recombination takes place at approximately equal concentrations of electrons and holes, while at low injection conditions (when one type of carrier dominates) the SRH recombination is suppressed. For cell degradation modes that affect the passivated interface (UVID, H-induced TOPCon contact degradation) the defects are at the interface under low-injection conditions due to either high local doping or the adjacent built-in charge in the dielectric. This mode is characterized by changes in the "diode prefactor" J01 slope in the inverse lifetime-injection level curve. In contrast, bulk degradation (LeTID, LID) affects bulk lifetime, with J01 slope unchanged. Carrier lifetime - injection level plots therefore serve as clear indicators of different degradation modes and are shown by experimental examples.

14 SOLAR ENERGY

BEST Field Degradation Research

Data for control and 5-year fielded bifacial modules of PERC and SHJ technologies, including IV Curves, EQE, EL and PL, for degradation and performance studies.

14 SOLAR ENERGY

Comparing Outdoor to Indoor Performance for Bifacial Modules Affected by Polarization-Type Potential-Induced Degradation

Bifacial photovoltaic (PV) modules have the advantage of using light reflected off of the ground to contribute to power production. Predicting the energy gain is challenging and requires complex models to do so accurately. Often, module degradation over time is neglected in models for the sake of simplicity or is underestimated. Comparing outdoor and indoor current–voltage (I–V) performance for bifacial modules is more challenging than for monofacial modules, as there are additional variables to consider such as rear albedo non-uniformity, cell mismatch, and their effects on temperature. This challenge is compounded when heterogeneous degradation modes occur, such as polarization-type potential-induced degradation (PID-p). To examine the effects of PID-p on I–V predictions using an empirical data-driven approach, 16 bifacial PERC modules are installed outdoors on racks with different albedo conditions. A subset is exposed to high-voltage biases of −1500 V or +1500 V. Outdoor data are traced at irradiance ranges of 150–250 W/m 2 , 500–600 W/m 2 , and 900–1000 W/m 2 . These curves are corrected using control module temperature, wire resistivity, and module resistance measured indoors. We examine several methods to transform indoor I–V curves to accurately, and more simply than existing methods, approximate outdoor performance for bifacial modules without and with varying levels of PID-p degradation. This way, bifacial performance modeling can be more accessible and informed by fielded, degraded modules. Distributions of percent errors between indoor and outdoor performance parameters and Mean Absolute Percent Errors (MAPEs) are used to assess method quality. Results including low-irradiance data (150–250 W/m 2 ) are discussed but are filtered for quantifying method quality as these data introduce substantial errors. The method with the most optimal tradeoff between low MAPE and analysis simplicity involves measuring the front side of a module indoors at an irradiance equal to plane-of-array irradiance plus the product of module bifaciality and albedo irradiance. This method gives MAPE values of 1–6.5% for non-degraded and 1.6–5.9% for PID-p degraded module performance.

14 SOLAR ENERGY

Enhancing lifetime, forecasting, and economic benefits of photovoltaic technologies undergoing UV-induced degradation with optical filtering

Ultraviolet-induced degradation (UV-ID) of various PV cell types was analyzed under optical UV filters with different cutoff wavelengths. Cell types studied included interdigitated back contact (IBC), passivated emitter and rear totally diffused (PERT), and heterojunction technology (HJT) based on crystalline Si (c-Si), and metal halide perovskite (MHP) cells. Analyzing degradation rates in two distinct regimes proved beneficial for all cell types. We used empirical linearizing functions ln(t) for c-Si technologies and 2 √t for MHP samples where t is time. These were applied to extrapolate UV-induced degradation over the lifetime of PV modules under various levels of optical UV filtering and used to predict the relative economic benefits for PV power plants. Degradation rates for all technologies were generally faster under the long pass optical filters having shorter cutoff wavelengths transmitting more UV irradiation and at elevated temperatures when testing MHP samples in the range between 60 °C and 90 °C.

14 SOLAR ENERGY