Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Statistical sensitivity on right-handed currents in presence of eV scale sterile neutrinos with KATRIN

The KATRIN experiment aims to determine the absolute neutrino mass by measuring the endpoint region of the tritium β-spectrum. As a large-scale experiment with a sharp energy resolution, high source luminosity and low background it may also be capable of testing certain theories of neutrino interactions beyond the standard model (SM). An example of a non-SM interaction are right-handed currents mediated by right-handed W bosons in the left-right symmetric model (LRSM). In this extension of the SM, an additional SU(2){sub R} symmetry in the high-energy limit is introduced, which naturally includes sterile neutrinos and predicts the seesaw mechanism. In tritium β decay, this leads to an additional term from interference between left- and right-handed interactions, which enhances or suppresses certain regions near the endpoint of the beta spectrum. In this work, the sensitivity of KATRIN to right-handed currents is estimated for the scenario of a light sterile neutrino with a mass of some eV. This analysis has been performed with a Bayesian analysis using Markov Chain Monte Carlo (MCMC). The simulations show that, in principle, KATRIN will be able to set sterile neutrino mass-dependent limits on the interference strength. The sensitivity is significantly increased if the Q value of the β decay can be sufficiently constrained. However, the sensitivity is not high enough to improve current upper limits from right-handed W boson searches at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for right-handed neutrinos from dark matter annihilation with gamma-rays

Several extensions of the Standard Model contain right-handed (sterile) neutrinos in the GeV-TeV mass range. Due to their mixing with the active neutrinos, they may give rise to novel effects in cosmology, neutrino physics, and collider searches. In addition, right-handed neutrinos can also appear as final states from dark matter annihilations, with important implications for dark matter indirect detection searches. In this paper, we use current data from the Fermi Large Area Telescope (6-year observation of dwarf spheroidal galaxies) and H.E.S.S. (10-year observation of the Galactic center) to constrain the annihilation of dark matter into right-handed neutrinos. We consider right-handed neutrino with masses between 10 GeV and 1 TeV, including both two-body and three-body decays, to derive bounds on the dark matter annihilation rate, ( σ v ), as a function of the dark matter mass. Our results show, in particular, that the thermal dark matter annihilation cross section, 3× 10{sup −26} cm{sup 3} s {sup −1} , into right-handed neutrinos is excluded for dark matter masses smaller than 200 GeV.

79 ASTRONOMY AND ASTROPHYSICS↗

The rapid-tome, a 3D-printed microtome, and an updated hand-sectioning method for high-quality plant sectioning

Abstract Background Microscopic analysis of plant anatomy is a common procedure in biology to study structure and function that requires high-quality sections for accurate measurements. Hand sectioning of specimens is typically limited to moderately soft tissue while harder samples prohibit sectioning by hand and/or result in inconsistent thicknesses. Results Here we present both a clearly described hand-sectioning method and a novel microtome design that together provide the means to section a variety of plant sample types. The described hand-sectioning method for herbaceous stems works well for softer subjects but is less suitable for samples with secondary growth (e.g., wood production). Instead, the “Rapid-Tome” is a novel tool for sectioning both soft and tougher high-aspect-ratio samples, such as stems and roots, with excellent sample control. The Rapid-Tome can be 3D-printed in approximately 18 h on a mid-quality printer common at university maker spaces. After printing and trimming, Rapid-Tome assembly takes a few minutes with five metal parts common at hardware stores. Users sectioned a variety of plant samples including the hollow internodes of switchgrass ( Panicum virgatum ), fibrous switchgrass roots containing aerenchyma, and woody branches of eastern red cedar ( Juniperus virginiana ) and American sycamore ( Platanus occidentalis ). A comparative analyses with Rapid-Tome-produced sections readily revealed a significant difference in seasonal growth of sycamore xylem vessel area in spring (49%) vs. summer (23%). Additionally, high school students with no prior experience produced sections with the Rapid-Tome adequate for comparative analyses of various plant samples in less than an hour. Conclusions The described hand-sectioning method is suitable for softer tissues, including hollow-stemmed grasses and similar samples. In addition, the Rapid-Tome provides capacity to safely produce high-quality sections of tougher plant materials at a fraction of the cost of traditional microtomes combined with excellent sample control. The Rapid-Tome features rapid sectioning, sample advancement, blade changes, and sample changes; it is highly portable and can be used easily with minimal training making production of thin sections accessible for classroom and outreach use, in addition to research.

3D-printing↗

Evaluation of Hands-On Cybersecurity Skills Development

Cybersecurity is a relatively new and quickly advancing industry, though there is a deficit in industry professionals throughout the world. This deficit is a result of the inability of education to keep up with the continuously changing cyber-threat landscape. A lack of effective, accessible, hands-on training platforms is a barrier for students and professionals who seek to gain the skills and abilities necessary to enter the workforce. Additionally, the lack of adequate training makes it difficult for industry experts to upskill or stay up to date on new advancements within the field of cybersecurity. The goal of this cohort is to discover what makes an effective or ineffective training platform, what platforms are currently available, and to determine the next steps for hands-on learning. Hands-on experience is necessary to create workforce ready professionals, yet it is underutilized by students and professionals of cybersecurity due to costs, availability, and ease of use. This cohort has uncovered hands-on training solutions, identified many effective training solutions, and explored potential improvement to cybersecurity training. These findings resulted in the cohort moving beyond research to test the resources that currently exist or are in development, and to apply that knowledge to discovering and developing engaging hands-on training.

97 MATHEMATICS AND COMPUTING↗

Hand Calculation Methods for Nuclear Criticality Safety

This primer provides an overview of the most common hand calculation methods used for criticality safety calculations. The most widely used tools available to a nuclear criticality safety (NCS) practitioner are probably the common Monte Carlo or deterministic criticality safety codes, which can be used to model very complex systems. However, use of these codes can obscure the parameters to which a particular fissile system may be sensitive, whereas the hand calculation methods can be used to delve into the ways each parameter may affect the reactivity of a fissile material system. Furthermore, practitioners must avoid using computer codes as devices that take inputs and simply provide outputs (i.e., a “black box”). Many years ago, pioneers such as Joe Thomas, David Smith, and Hugh Paxton, among others in the field of nuclear criticality safety, took the time before the advent of high-speed desktop computers to create simple hand methods for criticality safety analyses. Some of the methods can be used for single fissile units; others are applicable to fissile units arranged into simple array configurations. This primer discusses the applicability of the various methods, illustrates how they are used, and provides an interpretation of the various results. The NCS practitioner will need to spend time to master the methods that could be most useful; however, they can provide the practitioner with fast and accurate answers to criticality safety problems if they are used correctly and if critical data exist for the problem at hand. Hand calculation methods can be used as a starting point for more advanced calculations, and in many circumstances, they can provide sensitivity and perturbation information more quickly than using a criticality code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local Therapy for Rhabdomyosarcoma of the Hands and Feet: Is Amputation Necessary? A Report From the Children's Oncology Group

Purpose: To evaluate the outcome of children with rhabdomyosarcoma (RMS) of the hand or foot treated with surgery and/or local radiotherapy (RT). Methods and Materials: Forty-eight patients with nonmetastatic RMS of the hand or foot were enrolled on Intergroup Rhabdomyosarcoma Study III, IV-Pilot, and IV. Patients received multiagent chemotherapy with surgery and/or RT. Twenty-four patients (50%) underwent surgery without local RT, of whom 4 had complete resection and 20 had an amputation. The remaining 24 patients (50%) underwent local RT, of whom 2 required RT for microscopic residual disease after prior amputation. Median follow-up for surviving patients was 9.7 years. Results: Actuarial 10-year local control was 100%; 10-year event-free survival and overall survival rates were 62% and 63%, respectively. Poor prognostic factors for recurrence included gross residual (Group III) disease and nodal involvement (p = 0.01 and 0.05, respectively). More patients in the RT group had alveolar histology, Group III disease, and nodal involvement, as compared with the surgery group. There was no difference in 10-year event-free survival (57% vs. 66%) or overall survival (63% vs. 63%) between patients who underwent surgery or local RT. Among relapsing patients, there were no long-term survivors. No secondary malignancies have been observed. Conclusions: Despite having high-risk features, patients treated with local RT achieved excellent local control. Complete surgical resection without amputation is difficult to achieve in the hand or foot. Therefore, we recommend either definitive RT or surgical resection that maintains form and function as primary local therapy rather than amputation in patients with hand or foot RMS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Limb-Sparing Surgery and Radiation Therapy to Treat Sarcomas of the Hands and Feet: Long-Term Cancer Outcomes and Morbidity

Purpose: The purpose of this study was to investigate local control, survival outcomes, and complication rates of patients treated with limb-sparing surgery and radiation therapy (RT) for soft tissue sarcomas (STS) of the hands and feet. Methods and Materials: We reviewed the medical records of 85 consecutive patients treated for STS of the hands (n=38, 45%) and feet (n=47, 55%) between 1966 and 2012. The median age was 41 years (range, 10-82 years of age). Sixty-seven patients (79%) received postoperative RT after resection of their tumor (median dose, 60 Gy; range, 45-70 Gy). The remaining 18 patients (21%) were treated with preoperative RT followed by tumor resection (median dose, 50 Gy; range, 50-64 Gy). Results: Median follow-up was 140 months (range, 24-442 months). Five-year local control, overall survival, and disease-specific survival rates were 86%, 89%, and 89%, respectively. Positive or uncertain surgical margin status was the only factor adversely associated with local recurrence (19% vs 6% for negative margins, P=.046) but this lost significance on multivariate analysis when adjusting for RT dose ≥64 Gy. Of the 12 patients who had local relapses, 6 (50%) were salvaged, and only 2 of those required salvage amputation. Five patients had grade ≥3 late RT sequelae, with 2 patients (2%) having moderate limitations of limb function and 3 patients (4%) having severe limitations requiring procedures for skin ulceration. Conclusions: Limb-sparing surgery combined with RT provides excellent local control outcomes for sarcomas arising in the hands or feet. In patients who have local recurrence, salvage without amputation is possible. The excellent cancer control outcomes observed, considering the minimal impact on limb function, support use of combined modality, limb-sparing local therapy for STS arising in the hands or feet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-AB-210-01: Ultrasound Imaging and Therapy-Hands On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

MO-AB-210-02: Ultrasound Imaging and Therapy-Hands On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

Height Above Nearest Drainage (HAND) at Three-Meter Resolution for the State of Texas

URL: https://web.corral.tacc.utexas.edu/nfiedata/pin2flood/texas/ The current National Water Model and its Flood Inundation Mapping (FIM) service use 10-meter Height Above Nearest Drainage (HAND) hydrological terrain. In the Pin2Flood project (https://gis.tdem.texas.gov/portal/apps/storymaps/stories/72f0ec81a7654da688518f486122abed), funded by the Texas Division of Emergency Management (TDEM), ORNL computed the 3-meter HAND and associated synthetic rating curves for the State of Texas, covering 287,535 river streams (1.5km/stream) in 209 HUC8s. This archived dataset includes the HAND raster and the synthetic rating curve table for each of the 209 HUC8s in Texas. It is hosted at the Texas Advanced Computing Center (TACC). This 3-meter HAND is derived from the Fathom 3-meter DEM and NHDPlus V21 using an accelerated version of NOAA's Flood Inundation Mapping version 3 (FIM3, https://github.com/NOAA-OWP/inundation-mapping/tree/dev-fim3)

58 GEOSCIENCES↗

c-HAND: near real-time coastal flood mapping

The Texas Gulf Coast region contains significant centers of population, infrastructure, and economy and is threatened by intensifying tropical storms. The flooding from these tropical storms often has multiple compounding drivers. This characteristic presents a complex numerical problem where a simulation must consider multiple hydrologic forcings. While several procedures exist for addressing this problem numerically, they tend to be resource-intensive and cannot be conducted in near real-time. We extend GeoFlood, a reduced physics approach for fluvial flood forecasting, to rapidly predict coastal and compound fluvial-coastal inundation. This method is validated against a numerical ocean circulation model (ADCIRC) simulation of Hurricane Ike, a major coastal flooding event that happened on the Texas Gulf Coast in 2008. We show that the inundation map generated by coastal HAND (c-HAND) has reasonable agreement with the ADCIRC simulation while taking about 1.7% of the time currently needed to run ADCIRC on a supercomputer. While our model correctly predicts 99% of ADCIRC-inundated DEM cells, it also overpredicts inundated area by a factor of approximately 27%. We combine c-HAND with the GeoFlood framework for fluvial flood forecasting to create a compound fluvial-coastal inundation mapping workflow that can be run in near real-time. c-HAND's fast wall-clock time and low CPU requirements can support decision making by first response personnel. The method provides timely and convenient access to crucial information, such as the locations of flooded roads and inundated coastal areas.

42 ENGINEERING↗

Application of a headspace GC–MS method to evaluate the product quality of alcohol‐based hand wipe sanitizers

Abstract The investigation of marketed hand wipe sanitizers presented an analytical challenge owing to the need for extraction from the solid matrix of the products. The present work describes the development of a new sample preparation method for the extraction of analytes from the hand wipe sanitizer matrix into dimethyl sulfoxide for analysis using headspace GCMS. Alcohol‐based hand sanitizer (ABHS) wipe products labeled to contain ethanol or isopropanol as active ingredients were tested, varying in the size and weight of the wipes. The spike recovery assay was confirmed using spiking solutions containing impurities at concentrations equivalent to 50, 100 and 200% of the interim concentration limits. All of the tested analytes showed recovery within the allowable limits (80–120%). Six marketed ABHS wipe products were tested and no impurities above the FDA interim limits were observed. One product contained ethanol below the 60% v/v limit and another product was mislabeled for isopropanol and was found to contain ethanol instead. Four of the six ABHS products did not meet the label claim, which may affect the product quality. The analytical method and sample preparation procedures will provide the FDA and ABHS manufacturers with the capability to conduct quality assurance testing of hand wipe sanitizers for active ingredient content and impurities.

Biochemistry & Molecular Biology↗

Right-handed charged currents in the era of the Large Hadron Collider

We discuss the phenomenology of right-handed charged currents in the frame-work of the Standard Model Effective Field Theory, in which they arise due to a single gauge-invariant dimension-six operator. We study the manifestations of the nine complex couplings of the W to right-handed quarks in collider physics, flavor physics, and low-energy precision measurements. We first obtain constraints on the couplings under the assumption that the right-handed operator is the dominant correction to the Standard Model at observable energies. Here, we subsequently study the impact of degeneracies with other Beyond-the-Standard-Model effective interactions and identify observables, both at colliders and low-energy experiments, that would uniquely point to right-handed charged currents.

43 PARTICLE ACCELERATORS↗

Sclerotherapy of Diffuse and Infiltrative Venous Malformations of the Hand and Distal Forearm

PurposeVenous malformations (VM) involving the hand and forearm often lead to chronic pain and dysfunction, and the threshold for treatment is high due to the risk of nerve and skin damage, functional deterioration and compartment syndrome. The purpose of this study is to demonstrate that sclerotherapy of diffuse and infiltrative VM of the hand is a safe and effective therapy.Materials and MethodsA retrospective review of all patients with diffuse and infiltrative VM of the hand and forearm treated with sclerotherapy from 2001 to 2014 was conducted. All VM were diagnosed during the clinical visit by a combination of physical examination and imaging. Sclerotherapy was performed under imaging guidance using ethanol and/or sodium tetradecyl sulfate foam. Clinical notes were reviewed for signs of treatment response and complications, including skin blistering and nerve injury.ResultsSeventeen patients underwent a total of 40 sclerotherapy procedures. Patients were treated for pain (76 %), swelling (29 %) or paresthesias (6 %). Treatments utilized ethanol (70 %), sodium tetradecyl sulfate foam (22.5 %) or a combination of these (7.5 %). Twenty-four percent of patients had complete resolution of symptoms, 24 % had partial relief of symptoms without need for further intervention, and 35 % had some improvement after initial treatment but required additional treatments. Two skin complications were noted, both of which resolved. No motor or sensory loss was reported.ConclusionSclerotherapy is a safe and effective therapy for VM of the hand with over 83 % of patients experiencing relief.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel calcium recognition constructions in proteins: Calcium blade and EF-hand zone

Metal ions can regulate various cell processes being first, second or third messengers, and some of them, especially transition metal ions, take part in catalysis in many enzymes. As an intracellular ion, Ca{sup 2+} is involved in many cellular functions from fertilization and contraction, cell differentiation and proliferation, to apoptosis and cancer. Here, we have identified and described two novel calcium recognition environments in proteins: the calcium blade zone and the EF-hand zone, common to 12 and 8 different protein families, respectively. Each of the two environments contains three distinct structural elements: (a) the well-known characteristic Dx[DN]xDG motif; (b) an adjacent structurally identical segment, which binds metal ion in the same way between the calcium blade zone and the EF-hand zone; and (c) the following structurally variable segment, which distinguishes the calcium blade zone from the EF-hand zone. Both zones have sequence insertions between the last residue of the zone and calcium-binding residues in positions V or VI. The long insertion often connects the active and the calcium-binding sites in proteins. Using the structurally identical segments as an anchor, we were able to construct the classical calmodulin type EF-hand calcium-binding site out of two different calcium-binding motifs from two unrelated proteins.

60 APPLIED LIFE SCIENCES↗

Single-handed helical carbonaceous nanotubes prepared using a pair of cationic low molecular weight gelators

Highlights: • 3-aminophenol-formaldeyde resins were prepared through a templating method. • A pair of cationic gelators have been used as the templates. • Single-handed helical carbonaceous nanotubes were obtained after carbonization. • The carbonaceous nanotubes showed optical activity. - Abstract: We design a facile route to obtain enantiopure carbonaceous nanostructures, which have potential application as chiral sensors, electromagnetic wave absorbers, and asymmetric catalysts. A pair of cationic low molecular weight gelators was synthesized, which were able to self-assemble into twisted nanoribbons in ethanol at a concentration of 20 g L{sup −1} at 25 °C. Single-handed helical 3-aminophenol-formaldehyde resin nanotubes with optical activity were prepared using the self-assembly of the low molecular weight gelators as templates. After carbonization, single-handed helical carbonaceous nanotubes were obtained and characterized using circular dichroism, wide-angle X-ray diffraction, field-emission scanning electron microscopy, transmission electron microscopy, and Raman spectroscopy. The results indicate that the walls of the nanotubes are amorphous carbon. Moreover, the left- and right-handed helical nanotubes exhibit opposite optical activity.

36 MATERIALS SCIENCE↗

Efficacy of Low Level Laser Therapy After Hand Flexor Tendon Repair

Flexor tendon injury is a common problem requiring suturing repair followed by early postoperative mobilization. Muscle atrophy, joint stiffness, osteoarthritis, infection, skin necrosis, ulceration of joint cartilage and tendocutaneous adhesion are familiar complications produced by prolonged immobilization of surgically repaired tendon ruptures. The purpose of this study was to clarify the importance of low level laser therapy after hand flexor tendon repair in zone II. Thirty patients aging between 20 and 40 years were divided into two groups. Patients in group A (n = 15) received a conventional therapeutic exercise program while patients in group B (n = 15) received low level laser therapy combined with the same therapeutic exercise program. The results showed a statistically significant increase in total active motion of the proximal and distal interphalangeal joints as well as maximum hand grip strength at three weeks and three months postoperative, but improvement was more significant in group B. It was concluded that the combination of low level laser therapy and early therapeutic exercises was more effective than therapeutic exercises alone in improving total active motion of proximal and distal interphalangeal joints and hand grip strength after hand flexor tendon repair.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quasi-phase-matching of the dual-band nonlinear left-handed metamaterial

We demonstrate a type of nonlinear meta-atom creating a dual-band nonlinear left-handed metamaterial (DNLHM). The DNLHM operates at two distinct left-handed frequency bands where there is an interval of one octave between the two center frequencies. Under the illumination of a high-power signal at the first left-handed frequency band corresponding to fundamental frequency (FF), second-harmonic generation (SHG) is observed at the second left-handed band. This means that our DNLHM supports backward-propagating waves both at FF and second-harmonic (SH) frequency. We also experimentally demonstrate quasi-phase-matching configurations for the backward SHG. This fancy parametric process can significantly transmits the SH generated by an incident FF wave.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗