Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat Pump Sizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Enhanced Boiling on Micro-Configured Composite Surfaces Under Microgravity Conditions

In order to accommodate the growing thermal management needs of future space platforms, several two-phase active thermal control systems (ATCSs) have evolved and were included in the designs of space stations. Compared to the pumped single-phase liquid loops used in the conventional Space Transportation System and Spacelab, ATCSs offer significant benefits that may be realized by adopting a two-phase fluid-loop system. Alternately, dynamic power systems (DPSs), based on the Rankine cycle, seem inevitably to be required to supply the electrical power requirements of expanding space activities. Boiling heat transfer is one of the key technologies for both ATCSs and DPSs. Nucleate boiling near critical heat flux (CHF) can transport very large thermal loads with much smaller device size and much lower pumping power. However, boiling performance deteriorates in a reduced gravity environment and operation in the CHF regime is precarious because any slight overload will cause the heat transfer to suddenly move to the film boiling regime, which in turn, will result in burnout of the heat transfer surfaces. New materials, such as micro-configured metal-graphite composites, can provide a solution for boiling enhancement. It has been shown experimentally that this type of material manifests outstanding boiling heat transfer performance and their CHF is also extended to higher values. Due to the high thermal conductivity of graphite fiber (up to 1,200 W/m-K in the fiber direction), the composite surfaces are non-isothermal during the boiling process. The composite surfaces are believed to have a much wider safe operating region (a more uniform boiling curve in the CHF regime) because non-isothermal surfaces have been found to be less sensitive to variations of wall superheat in the CHF regime. The thermocapillary forces formed by the temperature difference between the fiber tips and the metal matrix play a more important role than the buoyancy in the bubble detachment, for the bubble detachment manifests itself by a necking process which should not be weakened by reduced gravity. In addition, the composite surfaces introduce no extra pressure drop, no fouling and do not impose significant primary or maintenance costs. All of these suggest that this type of composite is an ideal material for the challenge of accounting for both reliability and economy of the relevant components applied in the ATCSs, the DPSs and other devices in future space missions. The aim of the proposed work is to experimentally investigate high nucleate pool boiling performance on a micro-configured metal-graphite composite surface and to determine the mechanisms of the nucleate boiling heat transfer both experimentally and theoretically. Freon-113 and water will be used as the test liquids to investigate wettability effects on boiling characteristics. The Cu-Gr and Al-Gr composites with various volume fractions of graphite fibers will be tested to obtain the heat transfer characteristic data in the nucleate boiling region and in the CHF regime. In the experiments, the bubble emission and coalescence processes will be recorded by a video camera with a magnifying borescope probe immersed in the working fluid. The temperature profile in the thermal boundary layer on the composite surfaces will be measured by a group of micro thermocouples consisting of four ultra fine micro thermocouples. This instrument was developed and successfully used to measure the temperature profile of evaporating liquid thin layers by the proposers in a study performed at the NASA/Lewis Research Center. A two tier model to explain the nucleate boiling process and the performance enhancement on the composite surfaces has been suggested by the authors. According to the model, the thicknesses of the microlayer and the macrolayer underneath the bubbles and mushrooms, can be estimated by the geometry of the composite surface. The experimental results will be compared to the predictions from the model, and in turn, to revise and improve it.

Zhang, Nengli↗

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental performance analysis of a dual source heat pump integrated with thermal energy storage

To mitigate disturbances to the electric grid resulting from the growing penetration of intermittent and decentralized renewable generation, a dual-source (air source and ground source) heat pump (DSHP) integrated with thermal energy storage (TES) was developed. The DSHP can use either ambient air or the shallow subsurface of the ground to provide space heating or space cooling to the building as the conventional heat pump and produce hot/cold water for charging TES. Using dual sources (air and ground) can reduce the required size of the expensive ground heat exchangers while retaining high energy efficiency. During the off-peak period, the DSHP cools/heats the TES with low-cost electricity or overproduced renewable power. The stored cooling/heating energy in the TES is released during peak hours of the electric grid to meet the thermal demands of the building without consuming electricity to run the DSHP. A 2-ton (7 kW) prototype DSHP was developed and integrated with a 50-gallon (189 L) TES tank filled with a phase change material. Field tests were conducted to characterize the performance of the integrated system operating in various operation modes.

Wang, Lingshi↗

ThermalNetwork [SWR-23-101]

ThermalNetwork is software to size distributed ground heat exchangers for district-connected ground-source heat pump systems. The intended audience includes Ground Source Heat Pump Designers.

Mitchell, Matt↗

Thermodynamic Vent System Test in a Low Earth Orbit Simulation

A thermodynamic vent system for a cryogenic nitrogen tank was tested in a vacuum chamber simulating oxygen storage in low earth orbit. The nitrogen tank was surrounded by a cryo-shroud at -40 F. The tank was insulated with two layers of multi-layer insulation. Heat transfer into cryogenic tanks causes phase change and increases tank pressure which must be controlled. A thermodynamic vent system was used to control pressure as the location of vapor is unknown in low gravity and direct venting would be wasteful. The thermodynamic vent system consists of a Joule-Thomson valve and heat exchanger installed on the inlet side of the tank mixer-pump. The combination is used to extract thermal energy from the tank fluid, reducing temperature and ullage pressure. The system was sized so that the tank mixer-pump operated a small fraction of the time to limit motor heating. Initially the mixer used sub-cooled liquid to cool the liquid-vapor interface inducing condensation and pressure reduction. Later, the thermodynamic vent system was used. Pressure cycles were performed until steady-state operation was demonstrated. Three test runs were conducted at tank fills of 97, 80, and 63 percent. Each test was begun with a boil-off test to determine heat transfer into the tank. The lower tank fills had time averaged vent rates very close to steady-state boil-off rates showing the thermodynamic vent system was nearly as efficient as direct venting in normal gravity.

VanOverbeke, Thomas J.↗

Manufactured Home Equipment Sizing and Selection Tool

This tool is for use for manufactured homes built to the HUD Code (thermal provisions of the Manufactured Housing Construction and Safety Standards, Subpart F, Section §3280), including manufactured homes certified as ENERGY STAR® and DOE Efficient New Homes. It provides a simple look-up procedure to assist equipment specifiers, HVAC contractors, home installers, retailers, manufacturers, and electric utility staff. For new manufactured homes, it guides in selection of single speed heat pumps and air conditioners. For existing homes, it determines design conditions and nominal equipment size. The guidelines provide a simple but accurate procedure that reduces oversizing and its associated problems.

Source record↗

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗

Thermal Management System Modeling in the Heat Transport System Simulation (HeaTSSPy) Package

This paper describes the development of a thermal management system (TMS) concept design and analysis software package called Heat Transport System Simulation (HeaTSSPy). Built within Python using the OpenMDAO framework, HeaTSSPy can be used to size and optimize an active (using liquid/air heat exchangers) or passive (using finned heat sinks) TMS. The package makes use of modular TMS elements that allow for the creation of different system architectures and includes components such as heat sinks, heat exchangers, liquid pumps, fans, ducts, air inlets, air nozzles, and liquid pipes. Modeling methods for these components include a combination of physics-based analytical and empirical equations that relate component sizing criteria to system performance. The HeatSSPy heat sink methods are fully detailed within this paper, while the heat exchanger methods are described and referenced from previous work. This paper also uses high-fidelity simulation to validate two different methods of calculating thermal resistance using CFD results. Once the methods are fully described, the code is exercised to compare an active TMS with that of a passive TMS. Design criteria for this study include rejected heat, system altitude, Mach number, and ambient temperature. These criteria are used to develop a TMS system with estimated performance metrics such as weight, drag, and operational power. Results of this paper show the crossover point when a passive system begins to weigh more than an active system for a given heat rejection.

Thermal management system↗

SP-100 power system conceptual design for lunar base applications

A conceptual design is presented for a nuclear power system utilizing an SP-100 reactor and multiple Stirling cycle engines for operation on the lunar surface. Based on the results of this study, it was concluded that this power plant could be a viable option for an evolutionary lunar base. The design concept consists of a 2500 kWt (kilowatt thermal) SP-100 reactor coupled to eight free-piston Stirling engines. Two of the engines are held in reserve to provide conversion system redundancy. The remaining engines operate at 91.7 percent of their rated capacity of 150 kWe. The design power level for this system is 825 kWe. Each engine has a pumped heat-rejection loop connected to a heat pipe radiator. Power system performance, sizing, layout configurations, shielding options, and transmission line characteristics are described. System components and integration options are compared for safety, high performance, low mass, and ease of assembly. The power plant was integrated with a proposed human lunar base concept to ensure mission compatibility. This study should be considered a preliminary investigation; further studies are planned to investigate the effect of different technologies on this baseline design.

Mason, Lee S.↗

Size effects and electron microscopy of thin metal films

All films were deposited by resistive heated evaporation in an oil diffusion pumped vacuum system (ultimate approx. equal to 0.0000001 torr). The growth from nuclei to a continuous film is highly dependent on the deposition parameters, evaporation rate as well as substrate material and substrate temperature. The growth stages of a film and the dependence of grain size on various deposition and annealing parameters are shown. Resistivity measurements were taken on thin films to observe size effects.

Hernandez, J. D.↗

Final Design of Vacuum Pumping Systems for the Material Plasma Exposure eXperiment

The Material Plasma Exposure eXperiment (MPEX) vacuum pumping system is responsible for creating prototypic conditions in the plasma material interaction chamber that mimic those in a fusion reactor divertor region. Additionally, the vacuum system needs to minimize the pressure in the plasma heating region to improve the coupling of the electron cyclotron heating and ion cyclotron heating to the plasma, minimizing waste heat exhausted to high heat flux components. Here, the final design of the system has been sized to comply with the vacuum pump operating environment and to reduce the number of unique pumps required while meeting performance requirements. Bounding cases with and without the plasma present have been developed in the pumping analysis, and an initial calculation has been performed based on the plasma pumping identified in Proto-MPEX operation though this result will remain unverified until MPEX operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Preliminary Design of Nuclear Reactor Heat Delivery Systems: Integration with Reference Oil Refinery, Methanol Synthesis, and Hydrogen Production

The Department of Energy’s (DOE) Integrated Energy Systems (IES) program is generating comprehensive analyses validating the opportunity for using nuclear energy in a variety of applications including future clean grids, providing heat for direct use, and providing heat to help reduce emissions in chemical commodities. This work focuses on the preliminary designs of thermal delivery systems that can integrate heat produced from a nuclear core to industrial processes. The key research question that needs to be answered is: what is the prospective method for integrating nuclear generated heat energy into non-electric applications that can facilitate combined heat and power operations by advanced nuclear reactor systems? This research is a composition of case studies showing preliminary conceptual designs for thermal delivery systems integrating advanced nuclear systems with a few industrial systems including high temperature steam electrolysis, a reference oil refinery, and potential future methanol systems that supplant some natural gas use with nuclear energy. Piping and instrumentation diagrams have been developed to show the conceptual integration of nuclear systems with representative industrial systems. Different features of the configurations are dependent on the specific integration requirements including energy source conditions, demand quantity, and require energy application conditions. Design concepts are validated using thermodynamic balance calculations to verify system performance including calculating system losses during transport. Key components: pumps and compressors, heat exchangers, and network piping are reported with key design information and sizing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of thermocapillarity on an evaporating extended meniscus in microgravity

An analytical investigation of the effects of thermocapillarity on the flow field within and heat transfer from the extended meniscus region of a heated meniscus which is re-supplied by capillarity is presented. Microgravity conditions are considered. The analysis shows that even for extremely small temperature differences between the wall and the vapor (less than 1 mK) thermocapillary stresses at the liquid-vapor interface due to a non-uniform interfacial temperature drastically alters the flow field. At the same time, these stresses were shown to have only a slight effect on the heat transfer from the extended meniscus but increasing with an increasing temperature difference. Additionally, thermocapillary effects were shown to be sensitive to pore size. A criterion was established from a scaling analysis identifying the conditions necessary for thermocapillarity to affect the operation of capillary-pumped heat transport devices in microgravity. A critical Marangoni number and corresponding critical temperature difference between wall and vapor were identified.

Hallinan, Kevin P.↗

Compact and efficient elastocaloric heat pumps—Is there a path forward?

Elastocaloric cooling holds promise for energy-efficient heat pumping near room temperature with low environmental impact. Its adoption is, however, impeded by disproportionally large sizes of actuators compared with the active material volume. Taking magnetocaloric cooling as the baseline, the value of no more than 10:1 actuator volume to active material volume should lead to both size- and cost-effective solutions that may potentially be competitive with vapor-compression devices. With the goal to establish performance metrics that can lead to informed actuator selection for specific regenerator requirements, we analyze a wide range of elastocaloric materials and actuator technologies to find the best matches. We find that actuation with magnetic shape memory alloys meets all requirements; however, this technology is currently in early developmental stages and such actuators are not widely commercially available. Another promising and easily accessible option is standard rotary electric motors in combination with rotary-to-linear transduction mechanisms. A theoretical analysis of two case studies of elastocaloric systems using rotary electric motors with a Scotch yoke mechanism demonstrates the usefulness of our approach. Actuator requirements are based on two different regenerator configurations: one starting from zero strain without any mechanical energy recovery and another with 2% pre-strain and mechanical energy recovery to reduce the power and torque required from the motor. Our results indicate that the 10:1 target actuator to active material volume ratio can be met and feasibly lowered further, demonstrating that the proposed method for selecting actuators makes compact and efficient elastocaloric systems possible.

42 ENGINEERING↗

Application of thermal energy storage with electrified heating and cooling in a cold climate

Ground source heat pumps (GSHPs) have been shown to be an effective means of decarbonizing building heating and cooling, but the operation of these systems at scale presents challenges to sites and the grid due to increases in peak demand. Here, in this study, we investigate how the use of Thermal Energy Storage (TES), in the form of stratified water storage, could reduce the peak daily demand associated with GSHP systems and thus improve their cost effectiveness. This system was compared to a Combined Heat and Power (CHP) plant, to investigate the potential cost and emissions impacts of electrification on large energy users transitioning from high efficiency fossil fuel equipment. This study builds on previous research by using a significant campus area, and investigating the various impacts of an electrified system versus a state of the art fossil fuel system. An established method of TRNSYS modeling is used for the heat pumps and borehole heat exchangers (BHEs), along with the TES. The GSHP system with TES is modeled to follow industry standards and sized to provide an optimal balance of capital and operating costs. Costs were investigated for a unique large energy user rate structure, as well as for a more common generalized rate structure. The results show that the addition of TES to the GSHP system could reduce operating costs by 4.5%, but still incurs a 5.64% cost increase from the baseline CHP system. It is also shown, however, that a tactical integration of heat pumps into the CHP system is the most cost effective solution, only increasing the operating costs by 4.71%. Likewise, the impacts of different rate structures are highlighted, with the TES only resulting in 0.75% cost savings under the generalized utility rate. Furthermore, it is shown that thermal storage has great potential for demand reduction, with the addition of storage incurring a decrease of 7–22% in annual peak demand kW, dependent on the rate structure.

25 ENERGY STORAGE↗

Performance Evaluation of a Vapor-compression-cycle Based Heat Pump System for a Lunar Habitat under the Impact of Dust Deposits on the Coupled Radiators

Space exploration gains new momentum. A near goal is set by NASA to return humans to the Moon andestablish a sustainable presence on the lunar surface for more repeatable and affordable expeditions.The lunar dust is one of the dangerous environment hazard causing serious problems for explorationactivities. In this paper, in order to study the impact of lunar dust on the performance of a thermalmanagement system for a lunar habitat, a dynamical model of an active thermal control system that iscomprised of a vapor-compression cycle heat pump and a radiator loop is developed. A heat pump to liftthe heat rejection temperature is required due to high lunar daytime surface temperature. Parametricstudies on radiator size, percentage of dust coverage on the radiator, and lunar habitat location arecarried out. The results show that lunar deposits can significantly increase the power consumption ofthe thermal management system. A dust covered radiator panel results in net heat input to the heattransfer fluid during the period of strong solar irradiance, causing deteriorated performance of theradiator loop. The lunar dust contamination problem raises the requirement of redundancy design of asystem for fault tolerance. A synergetic design of a thermal management system, a power generationsystem and robotic maintenance system is proposed to achieve maximal mass cut for a whole lunarhabitat system.

Chunjian Pan↗