Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat resilience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

LA100 Equity Strategies. Chapter 7: Housing Weatherization and Resilience

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on housing weatherization and access to cooling as means to achieve more equitable resilience to heat waves during unplanned power outages. Specifically, NREL used weather, housing, and socioeconomic data to characterize LA's residential building stock. We?developed a residential building stock model to simulate the energy use of 50,000 dwellings representing the diversity of housing types, appliances, climate zones, and household incomes across Los Angeles. We then simulated and evaluated the impacts of 10 building envelope and cooling upgrades on indoor temperature - a main cause of heat-induced health risks-over a 4-day power outage during a heat wave. We examined occupant exposure to extreme heat and how heat exposure changes with each upgrade across income, tenure (renter/owner status), building type, and disadvantaged community (DAC) status. We also examined upgrade costs and utility bills. Based on the results of our analysis and community guidance, we identified building envelope upgrades and cooling strategies that could save lives and maintain safe home temperatures for LA's low-income households in the event of a planned or unplanned power outage during a summer heat wave. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

building envelope↗

Reusable Thermal Barrier for Insulation Gaps

Filler composed of resilient, heat-resistant materials. Thermal barrier nestles snugly in gap between two tiles with minimal protrusion beyond faces of surrounding tiles. When removed from gap, barrier springs back to nearly original shape. Developed for filling spaces between tiles on Space Shuttle, also used in furnaces and kilns.

Saladee, C. E.↗

Multi-criteria thermal resilience certification scheme for indoor built environments during heat waves

With climate change, the indoor built environment is expected to significantly influence the occupant's safety and well-being. A novel multi-criteria thermal resilience certification scheme for indoor built environments during extreme heat events is proposed in this paper. The certification scheme considers overheating, thermal comfort, heat stress, and hygrothermal discomfort in built environments. These criteria are quantified using key performance indicators like indoor overheating degree, hours of exceedance, wet-bulb globe temperature, and heat index, respectively. This scheme is developed based on existing best practices like standards, rating systems, and literature. The scheme is implemented on a benchmark building energy performance model for detached post-World War II dwellings in Belgium as a case study using weather data measured from the City of Brussels. The indoor overheating in the reference dwelling is assessed with a static threshold of 27 °C for the bedrooms and adaptive thresholds for other areas. The analysis found that the building performance is within the defined threshold levels throughout the heat wave duration for all criteria. Therefore, the reference dwelling got a maximum attainable score of four points and is rated five-star for thermal resilience during heat waves. The proposed certification scheme is intended as a standardized framework and highlights the need for further revisions in building performance policies and guidelines.

Climate change↗

Assessing thermal resilience of an assisted living facility during heat waves and cold snaps with power outages

Extreme hot and cold weather events are becoming more frequent, intense, and longer due to climate change. When these events occur coincidentally with power outages, the resulting extreme indoor temperatures pose a severe health hazard for occupants. This study conducted a holistic modeling and analysis of an assisted living facility, where senior residents live, to assess its thermal resilience performance under a six-day heat wave in 2015 and a three-day cold snap in 2021 with power outages. Impacts of 13 energy efficiency measures on thermal resilience and backup power capacity of the facility were evaluated. Three thermal resilience metrics: the SET (standard effective temperature) degree-hours, the Heat Index, and the Hours of Safety, were used and calculated from the EnergyPlus simulation models. Furthermore, major findings are: (1) the facility would suffer from extreme temperatures during the cold and hot events without a power supply, not meeting the passive survivability requirements; (2) most passive envelope measures improve thermal resilience for both hot and cold events, but making the building envelope airtight results in conflicting performance between the hot and cold events; (3) natural ventilation is an effective measure to mitigate summer indoor overheating; and (4) the energy efficiency package can reduce backup power capacity by 19% for the three-day cold snap. It is recommended that building technologies and design strategies be evaluated to consider co-benefits of energy use, thermal resilience, and backup power needs through building energy codes or policies for existing and new buildings, which are transitioning for decarbonization and climate resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-flammable polyimide materials for commercial application

Thermally-stable, fire-resistant polyimide foams developed for use as fire protection in aircraft, spacecraft and ground applications are presented. Polyimide precursors, synthesized by the reaction of 3, 3', 4, 4'-benzophenone tetracarboxylic acid dianhydride with a mixture of two diamines, can be processed into foams by indirect or direct heating techniques. Flexible resilient foams and thermal acoustical foams produced by the microwave heating of polyimide precursors are shown to conform to requirements for aircraft seating foams and thermal and acoustical insulation materials, respectively. Rigid polyimide foams reinforced by carbon mat, chopped carbon mat and chopped glass strand fillers and prepared by the microwave heating of a continuous mat, followed by its compression, or by filling a honeycomb structure with low density foam, are found to exhibit outstanding fire resistance and have mechanical properties approaching those desired for structural materials.

Gagliani, J.↗

Baltimore Energy & Infrastructure: Assessing Urban Heat Vulnerability in Baltimore Neighborhoods to Inform Transportation Resiliency Planning Efforts

Across the world, climate change is altering cities and their local climate systems. Following global trends of rising mean temperatures, Baltimore, Maryland is projected to experience more frequent extreme heat events. Exacerbated by Urban Heat Island (UHI) effects, residents of the city face high temperatures from limited tree canopy, highly paved and impervious surfaces, limited air flow, and high concentrations of localized emissions. Urban heat is dispersed asymmetrically, with historically marginalized populations experiencing disproportionately severe heat. Recognizing the impacts of extreme urban heat, the Maryland Transit Administration (MTA) collaborated with us, the Spring 2024 Goddard Energy and Infrastructure NASA DEVELOP team to assess urban impacts of MTA users and assets and explore opportunities to enhance resiliency planning. We evaluated the feasibility of NASA Earth observations (EOs) in visualizing heat vulnerability in Baltimore City and County. We mapped UHI and extreme heat using remote sensing observations, tailored a Heat Priority Score (HPS) to analyze heat data in tandem with socioeconomic data from American Community Survey (ACS), and utilized SOlar and LongWave Environmental Irradiance Geometry (SOLWEIG) model to estimate MTA riders’ thermal comfort. NASA EOs served to quantify the distribution and severity of extreme heat at the block group level, which was found to correlate with a lack of vegetation and presence of densely built-up surroundings. The HPS revealed that extreme heat events most negatively impact communities that exhibit social vulnerability through indicators such as age, race, and income. These findings will inform neighborhood resiliency plans for the MTA that can be incorporated into their Adaptation Resiliency Toolbox (ART).

Baltimore,↗

San Diego Urban Development: Utilizing NASA Earth Observations to Identify Drivers of Extreme Urban Heat and Generate a High-Resolution Vulnerability Index for Urban Planning and Climate Resiliency in San Diego, California

Exposure to heat exacerbated by an increase in urbanization as well as increasing global temperatures has become a growing concern for cities and their residents. Excess heat can cause increased heat-related morbidity, mortality, and energy costs. Vulnerability to heat-related illnesses is oftentimes correlated to demographics, socioeconomic status, and pre-existing health conditions. The City of San Diego, California boasts 1.4 million residents and, like many other major cities, has experienced increases in heat-related hospitalizations and mortality. The burden of urban heat is also not equal amongst communities; areas with lower income and communities of color bear a disproportionate burden. In partnership with the City of San Diego, and American Geophysical Union’s (AGU) Thriving Earth Exchange, the DEVELOP team used Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), and ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) imagery to identify areas of highest heat based on land surface temperature from 2015-2020. Our analyses showed that health demographics such as obesity and cardiovascular health were the strongest indicators for heat vulnerability. In addition, various inputs (land use/land cover, tree canopy, and building intensity derived from the City of San Diego data along with albedo from Landsat 8) were used in the Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) urban cooling model to investigate changes in cooling rates in current and future scenarios for the city. The model results showed that cooling is expected to occur due to a 5% increase in tree canopy. The City of San Diego can use these results to inform the development of the Climate Resilient San Diego plan and prioritize at-risk communities for cooling interventions.

John Dialesandro↗

The tepary bean genome provides insight into evolution and domestication under heat stress

Tepary bean (Phaseolus acutifolis A. Gray), native to the Sonoran Desert, is highly adapted to heat and drought. It is a sister species of common bean (Phaseolus vulgaris L.), the most important legume protein source for direct human consumption, and whose production is threatened by climate change. Here, we report on the tepary genome including exploration of possible mechanisms for resilience to moderate heat stress and a reduced disease resistance gene repertoire, consistent with adaptation to arid and hot environments. Extensive collinearity and shared gene content among these Phaseolus species will facilitate engineering climate adaptation in common bean, a key food security crop, and accelerate tepary bean improvement.

54 ENVIRONMENTAL SCIENCES↗

Informing the planning of rotating power outages in heat waves through data analytics of connected smart thermostats for residential buildings

Abstract With climate change, heat waves have become more frequent and intense. Rotating power outages happen when the power supply is unable to meet the cooling demand increase resulting from extreme high temperatures. Power outages during heat waves expose residents to high risks of overheating. In this study, we propose a novel data-driven inverse modelling approach to inform decision makers and grid operators on planning rotating power outages. We first infer the building thermal characteristics using the connected smart thermostat data, and used the estimated thermal dynamics to simulate the thermal resilience during a heat wave event. Our proposed method was tested for the California power outage in August 2020 by using the open source Ecobee Donate Your Data dataset. We found in California the power outage should not last more than two hours during heat waves to avoid overheating risks. Informing the residents in advance so they can prepare for it through pre-cooling is a simple but effective strategy to expand the acceptable power outage duration. In addition to assisting power outage planning, the proposed method can be used for other applications, such as to evaluate a building energy efficiency policy, to examine fuel poverty, and to estimate the load shifting potential of building stocks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Wichita Climate: Using Satellite Data to Identify Neighborhoods Vulnerable to Extreme Heat for Equitable Climate Mitigation and Planning

Wichita, Kansas is facing a host of climate threats, one being extreme heat that is manifested through the urban heat island (UHI) effect. The uneven distribution of heat risk in Wichita across socioeconomic status is an environmental justice issue. We worked with the City of Wichita to map heat exposure, tree canopy, and heat risk in order to support the City's climate resilience initiatives. To visualize heat exposure, we quantified and mapped average summer heat from 2013–2021 using Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) Land Surface Temperature (LST) and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) night-time LST. To understand tree canopy cover gaps, we created a tree canopy map using 2021 PlanetScope imagery, which identified 20% more trees than the US Geological Survey’s (USGS) National Land Cover Database (NLCD) tree canopy coverage estimates for Wichita. To characterize high risk areas, we used socioeconomic census data and existing social vulnerability indices, highlighting populations that were exposed and vulnerable to extreme heat. The spatial analyses demonstrated that heat exposure is concentrated in the city center and southwest Wichita, areas that are also low in tree canopy coverage. The three census block groups and 17 census tracts with the highest heat risk primarily circle the city center, in areas home to more socially vulnerable populations and near enough to the dense urban center to feel significant urban heat island effects.

Brooke Laird↗

Wichita Climate: Using Satellite Data to Identify Neighborhoods Vulnerable to Extreme Heat for Equitable Climate Mitigation and Planning

Wichita, Kansas is facing a host of climate threats, one being extreme heat that is manifested through the urban heat island (UHI) effect. The uneven distribution of heat risk in Wichita across socioeconomic status is an environmental justice issue. We worked with the City of Wichita to map heat exposure, tree canopy, and heat risk in order to support the City's climate resilience initiatives. To visualize heat exposure, we quantified and mapped average summer heat from 2013–2021 using Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) Land Surface Temperature (LST) and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) night-time LST. To understand tree canopy cover gaps, we created a tree canopy map using 2021 PlanetScope imagery, which identified 20% more trees than the US Geological Survey’s (USGS) National Land Cover Database (NLCD) tree canopy coverage estimates for Wichita. To characterize high risk areas, we used socioeconomic census data and existing social vulnerability indices, highlighting populations that were exposed and vulnerable to extreme heat. The spatial analyses demonstrated that heat exposure is concentrated in the city center and southwest Wichita, areas that are also low in tree canopy coverage. The three census block groups and 17 census tracts with the highest heat risk primarily circle the city center, in areas home to more socially vulnerable populations and near enough to the dense urban center to feel significant urban heat island effects.

Brooke Laird↗

Load Matching Potential of Urban Renewables during Extreme Heat in New York City

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on the matter by assessing the feasibility of using offshore wind and rooftop photovoltaic systems to meet electricity demand during a period of thermal stress in New York City—August 2019. A unified modelling framework, based on the Urbanized Weather Research and Forecasting model, is used to simulate climate, renewable resources and energy demand variables. Findings show significant energy load miss-match, ranging from 3 to 5 GW, between the demand and the composite renewable generation outcome. This study provides a transferable framework for evaluating renewable integration in dense urban regions and highlights the need for additional strategies to support grid resilience during extreme heat events, while clarifying the role of local resources in fully managing NYC’s load.

54 ENVIRONMENTAL SCIENCES↗

Unified Modeling Architecture for Load Management in Extreme Heat: The New York City Case

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on this key subject by assessing the feasibility of using coastal-urban renewable energy resources, namely, offshore wind and rooftop photovoltaic systems, to meet electricity demand of New York City during the intense recent heat wave period of June 2025. A unified modeling framework, based on the urbanized weather research and forecasting model, is used to simulate climate, renewable resources, and energy demand variables. Findings show significant energy load mismatch of approximately 1150 GWh over the month, between the demand and the combined renewable generation outcome. Three storage integration scenarios are analyzed to mitigate the deficits, reducing said deficits by a minimum of approximately 9% over the duration of the month. This study provides a transferable modeling framework tool for evaluating renewable integration in dense urban environments that can be used by grid operators to support grid resilience during extreme heat events.

54 ENVIRONMENTAL SCIENCES↗

The Road to Mach 10: A History of the X-43A Hypersonic Flight Test Program at NASA Dryden...Toward the Future

In terms of technology, the X-43A/Hyper-X represented a singular milestone. After nearly a half century of high hopes, studies, wind tunnel tests, proposals, and canceled projects, a scramjet-powered vehicle had flown. The performance of the engine qualified the scramjet design tools and scaling laws. In turn, the theoretical calculations and ground testing could be used to design more advanced engine concepts. Just as important, both the scramjet and vehicle systems had successfully operated in the variable temperatures and densities of the atmosphere. The X-43A systems were able to maintain the exact flight conditions necessary for the scramjet to operate properly. Control deflections to correct the engine-induced moments were close to pre-flight predictions. When the unexpected occurred, such as when the vehicle pitched up during the cowl opening on the second flight, the control system was sufficiently designed to correct the situation. The airframe and wing structure, the thermal protection material, and the internal conditions of the X-43A performed largely as predicted. The HXLV thermal anomaly during the ascent on the third flight and "the Mach 8 unpleasantness" during the descent indicated that the HXLV and X-43A were not as resilient to aerodynamic heating as expected. The X-43A 's airframe drag and lift both were slightly higher than predicted, but still within preflight uncertainty predictions. The stability and control were as predicted, as was the boundary layer transition. The biggest aerodynamic worry before the flight was the separation of the HXLV and the X- 43A. After all was said and done, this went exactly as predicted, proving that non-symmetrical/high-dynamic pressure stage separations could be performed. This in turn meant that two-stage-to-orbit vehicles employing this technology were feasible. The Hyper-X program also served as a training ground for a new generation of scramjet and hypersonic researchers. This included both NASA and contractor personnel, providing them with experience in ground testing and component development; vehicle design, construction, integration, system checkout, and, ultimately, flight testing and data analysis. Additionally, researchers learned the practical details of running a project within finite budget and time limits, about the ambiguousness of risk assessment, and about the need to spend a significant amount of time and effort dealing with engineering problems, such as those with the FAS, that have nothing to do with the project's research goals. Finally, all those who worked on the X-43A project now know what it is like to spend years transforming an idea into a functional vehicle, only for it to be lost in a matter of seconds. And then to go through years of work to correct the problems, to face the possibility that still more might exist, and finally to savor the triumph of two successful flights. For those who will work on the hypersonic projects that emerge in coming years, these experiences may prove to be the most valuable of all.

Peebles, Curtis↗

Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home

Extreme weather events become more frequent and severe due to climate change. Although energy efficiency technologies can influence thermal resilience of buildings, they are traditionally studied separately, and their interconnections are rarely quantified. This study developed a methodology of modeling and analysis to provide insights into the nexus of thermal resilience and energy efficiency of buildings. In this work, we conducted a case study of a real nursing home in Florida, where 12 patients died during Hurricane Irma in 2017 due to HVAC system power loss, to understand and quantify how passive and active energy efficiency measures (EEMs) can improve thermal resilience to reduce heat-exposure risk of patients. Results show that passive measures of opening windows and doors for natural ventilation, as well as miscellaneous load reduction, are very effective in eliminating the extreme dangerous occasions. However, to maintain safe conditions, active measures such as on-site power generators and thermal storage are also needed. The nursing home was further studied by changing its location to two other cities: San Francisco (mild climate) and Chicago (cold winter and hot summer). Results revealed that the EEMs' impacts on thermal resilience vary significantly by climate and building characteristics. The study also estimated the costs of EEMs to help stakeholders prioritize the measures. Passive measures that may not save energy may greatly improve thermal resilience, and thus should be considered in building design or retrofit. Findings from this study indicate energy efficiency technologies should be evaluated not only by their energy savings performance but also by their influence on a building's resilience to extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of High Temperature Knitted Spring Tubes for Structural Seal Applications

Control surface seals are crucial to current and future space vehicles, as they are used to seal the gaps surrounding body flaps, elevons, and other actuated exterior surfaces. During reentry, leakage of high temperature gases through these gaps could damage underlying lower temperature structures such as rudder drive motors and mechanical actuators, resulting in impaired vehicle control. To be effective, control surface seals must shield lower temperature structures from heat transfer by maintaining sufficient resiliency to remain in contact with opposing sealing surfaces through multiple compression cycles. The current seal exhibits significant loss of resiliency after a few compression cycles at elevated temperatures (i.e., 1900 F) and therefore would be inadequate for advanced space vehicles. This seal utilizes a knitted Inconel X-750 spring tube as its primary resilient element. As part of a larger effort to enhance seal resiliency, researchers at the NASA Glenn Research Center performed high temperature compression testing (up to 2000 F) on candidate spring tube designs employing material substitutions and modified geometries. These tests demonstrated significant improvements in spring tube resiliency (5.5x better at 1750 F) through direct substitution of heat treated Rene 41 alloy in the baseline knit design. The impact of geometry modification was minor within the range of parameters tested, however trends did suggest that moderate resiliency improvements could be obtained by optimizing the current spring tube geometry.

Taylor, Shawn C.↗