Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat source calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Liquid crystal point diffraction interferometer

A new instrument, the liquid crystal point diffraction-interferometer (LCPDI), has been developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point diffraction interferometer (PDI) and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with very high data density and with automated data reduction. This dissertation describes the theory of both the PDI and liquid crystal phase control. The design considerations for the LCPDI are presented, including manufacturing considerations. The operation and performance of the LCPDI are discussed, including sections regarding alignment, calibration, and amplitude modulation effects. The LCPDI is then demonstrated using two phase objects: defocus difference wavefront, and a temperature distribution across a heated chamber filled with silicone oil. The measured results are compared to theoretical or independently measured results and show excellent agreement. A computer simulation of the LCPDI was performed to verify the source of observed periodic phase measurement error. The error stems from intensity variations caused by dye molecules rotating within the liquid crystal layer. Methods are discussed for reducing this error. Algorithms are presented which reduce this error; they are also useful for any phase-stepping interferometer that has unwanted intensity fluctuations, such as those caused by unregulated lasers.

Mercer, Carolyn R.↗

Electric current heating calibration of a laser holographic nondestructive test system

Holographic NDT was used to measure small surface displacements controlled by electric heating by detecting the difference of the interference fringe patterns as viewed through the hologram on a real time basis. A perforated aluminum test plate, with the holes used to position thin metal foils, was used in the experiment. One of the foils was connected to an electric power source and small displacements of the foil were caused and controlled by Ohmic heating. An He-Ne laser was used to perform the holography.

Liu, H.-K.↗

Steady-State and Frequency Response of a Thin-Film Heat Flux Gauge

A new and simpler design of thin-film heat flux gauge has been developed for use In high-heat-flux environments. Heat flux gauges of the same design were fabricated on three different substrates and tested. The heat flux gauge comprises a thermopile and a thermocouple junction, which measures the surface temperature. The thermopile has 40 pairs of S-type thermocouples and is covered by two thermal resistance layers. Calibration and testing of these gauges were first carried out in an arc-lamp calibration facility. Sensitivity of the gauge was discussed in terms of the relative conductivity and surface temperature. The heat flux calculated from the gauge output was In good agreement with the precalibrated standard sensor. The steady-state and the transient response characteristics of the heat flux gauge were also investigated using a carbon dioxide pulse laser as a heat source. The dynamic frequency response was evaluated in terms of the nondimensional amplitude ratio with respect to the frequency spectrum of a chopped laser bcam. The frequency response of the gauge was determined to be about 3 kHz. The temperature profiles in the thin-film heat flux gauge were obtained numerically in steady-state conditions using FLUENT and compared with the experimental results.

Fralick, Gustave C.↗

Modeling Laminar-to-Turbulent Transition in the Panel Test Facility Arcjet

A computational fluid dynamics (CFD) laminar-to-turbulence transition model was developed for the NASA Ames Research Center’s 20 MW Panel Test Facility (PTF). Surface pressure, heat flux to a water-cooled plate, and surface temperature on a tile plate coated with reaction-cured glass were measured across several conditions in the facility and compared with laminar and fully-turbulent CFD simulations. The potential for bypass transition in the PTF nozzle was assessed via application of the Langtry-Menter four-equation transitional shear-stress transport (SST) model. Results from the transition model were inconsistent with measurements. Flow interaction with a boundary conditioning plate feature inside the nozzle was also investigated as a potential source of laminar-to-turbulent transition using two turbulence models with specified transition locations. The Baldwin-Lomax turbulence model was configured to simulate a transition at the upstream edge of the boundary conditioning plate and produced results consistent with the surface pressure measurements but not the cold-wall heat flux. Finally, the SST turbulence model was calibrated to transition at the upstream edge of the boundary conditioning plate and produced results consistent with both the surface pressure and cold-wall heat flux measurements. The SST-based model demonstrated reasonable agreement with surface temperature measurements on the reaction-cured glass tile, albeit with some discrepancies.

Computational Fluid Dynamics↗

Natural interference phenomena affecting spaceborne receivers

Earth orbiting microwave receivers which are vulnerable to the interference from natural sources, mainly, the Sun and the Moon, are discussed. The irradiance from the Sun affects microwave receivers in two ways: (1) the infrared component of the irradiance causes nonuniform heating in metal structures and produces distortions that affect electrical performance; and (2) the graybody radiation component of the solar irradiance enters the collecting aperture of the antenna and the feed ports of the calibration circuits. The graybody radiation operates to degrade the signal to noise ratios and vitiate the internal calibration accuracy. The magnitudes of interference from the Sun and the Moon are analyzed and mathematical expressions are derived which serve to quantify the expected interference levels.

Stacey, J. M.↗

Thermal Infrared Sensor (TIRS) Instrument Thermal Subsystem Design and Lessons Learned

The Thermal Infrared Sensor (TIRS) is one of two instruments on the Landsat Data Continuity Mission (LDCM), which is scheduled to launch in February of 2013. The TIRS instrument was officially added to the mission later in the flow, which led to a highly aggressive schedule that became one of the main drivers during instrument development. The thermal subsystem design of the TIRS Sensor Unit is comprised of five thermal zones which range in temperature from less than 43 Kelvin to 330 Kelvin. Most zones are proportional heater controlled, and all are within a volume of 35 cu.ft. A two-stage cryocooler is used to cool the "cold stage" including three QWIP detectors to less than 43 Kelvin, and cool the "warm stage" to 105 Kelvin. The excess power dissipation from the cryocooler is rejected via ammonia transport heat pipes to a dedicated Cryocooler Radiator with embedded ammonia heat pipes. The cryogenic subsystem includes a series of shells used to radiatively and conductively isolate the cold stage from the warmer surroundings. The Optical System (telescope) is passively cooled to 180-190 Kelvin using a "thermal link" (comprised of a Flexible Conductive Thermal Strap and an APG Bar) which couples the telescope stage to a dedicated radiator with embedded ethane heat pipes. The Scene Select Mechanism, which is responsible for moving the Scene Select Mirror to three distinct positions (including Nadir, Space, and On-board Black Body Calibrator pointing), runs nominally at 278 Kelvin and is thermally isolated from the cryogenic thermal zones. The On-board Black Body Calibrator requires a dedicated radiator which allows for a temperature range of 260-330 Kelvin at the Source. The detectors are powered by the FPE Box, which is mounted to the nadir external surface of the composite honeycomb structure. There are two additional electronics boxes which are wet-mounted directly to the spacecraft shear panel, the Main Electronics Box and Cryocooler Electronics Box; thermal control of these boxes is the responsibility of Orbital Sciences Corporation, the spacecraft developer. The TIRS thermal subsystem design was successfully verified during months of testing campaign, from component & subsystem level to two instrument-level thermal vacuum tests. The Instrument, despite an aggressive schedule, was delivered to the spacecraft vendor in February of 2012 and is currently undergoing the final stages of spacecraft environmental testing in preparation for launch.

Otero, Veronica↗

Atmospheric Entry Heat Flux Sensor Calibration and Flight Data Analysis

- Recent NASA missions have included total heat flux sensors (THFS) embedded in the thermal protection system (TPS) to measure the combined convective and radiative heating during atmospheric entry. These measurements are key to fundamental entry science and mission design. - The THFSs for the Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite on the Mars 2020 entry vehicle and the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) technology demonstration mission were passively cooled Schmidt–Boelter gauges. - As presented at IPPW 2021, THFS calibration is notoriously difficult and includes several sources of measurement uncertainty [1]. - Recent work has been conducted to understand and quantify the measurement uncertainty in the MEDLI2 and LOFTID Schmidt-Boelter THFSs.

R. A. Miller↗

Update on Apollo Data Restoration by the NSSDC and the PDS Lunar Data Node

The Lunar Data Node (LDN) , under the auspices of the Geosciences Node of the Planetary Data System (PDS) and the National Space Science Data Center (NSSDC), is continuing its efforts to recover and restore Apollo science data. The data being restored are in large part archived with NSSDC on older media, but unarchived data are also being recovered from other sources. They are typically on 7- or 9-track magnetic tapes, often in obsolete formats, or held on microfilm, microfiche, or paper documents. The goal of the LDN is to restore these data from their current form, which is difficult for most researchers to access, into common digital formats with all necessary supporting data (metadata) and archive the data sets with PDS. Restoration involves reading the data from the original media, deciphering the data formats to produce readable digital data and converting the data into usable tabular formats. Each set of values in the table must then be understood in terms of the quantity measured and the units used. Information on instrument properties, operational history, and calibrations is gathered and added to the data set, along with pertinent references, contacts, and other ancillary documentation. The data set then undergoes a peer review and the final validated product is archived with PDS. Although much of this effort has concentrated on data archived at NSSDC in the 1970's, we have also recovered data and information that were never sent to NSSDC. These data, retrieved from various outside sources, include raw and reduced Gamma-Ray Spectrometer data from Apollos 15 and 16, information on the Apollo 17 Lunar Ejecta And Meteorites experiment, Dust Detector data from Apollos 11, 12, 14, and I5, raw telemetry tapes from the Apollo ALSEPs, and Weekly Status Reports for all the Apollo missions. These data are currently being read or organized, and supporting data is being gathered. We are still looking for the calibrated heat flow data from Apollos 15 and 17 for the period 1975-1977, any assistance or information on these data would be welcome. NSSDC has recently been tasked to release its hard-copy archive, comprising photography, microfilm, and microfiche. The details are still being discussed, but we are concentrating on recovering the valuable lunar data from these materials while they are still readily accessible. We have identified the most critical of these data and written a LASER proposal to fund their restoration. Included in this effort are data from the Apollo 15 and 16 Mass Spectrometers and the Apollo 17 Par-UV Spectrometer and ancillary information on the Apollo 17 Surface Electrical Properties Experiment.

Williams, David R.↗

Carbon nanotube vacuum gauges with wide-dynamic range and processes thereof

A miniature thermal conductivity gauge employs a carbon single-walled-nanotube. The gauge operates on the principle of thermal exchange between the voltage-biased nanotube and the surrounding gas at low levels of power and low temperatures to measure vacuum across a wide dynamic range. The gauge includes two terminals, a source of constant voltage to the terminals, a single-walled carbon nanotube between the terminals, a calibration of measured conductance of the nanotube to magnitudes of surrounding vacuum and a current meter in electrical communication with the source of constant voltage. Employment of the nanotube for measuring vacuum includes calibrating the electrical conductance of the nanotube to magnitudes of vacuum, exposing the nanotube to a vacuum, applying a constant voltage across the nanotube, measuring the electrical conductance of the nanotube in the vacuum with the constant voltage applied and converting the measured electrical conductance to the corresponding calibrated magnitude of vacuum using the calibration. The nanotube may be suspended to minimize heat dissipation through the substrate, increasing sensitivity at even tower pressures.

Manohara, Harish↗

The nature of Aquila X-1

Photometry in the UBV spectra was used to observe Aquila X-1. This X-ray source, usually producing flux on the order of 1-10% that of the Crab Nebula, often behaves in a manner resembling the behavior of galactic X-ray stars. A description of the calibration methods used in the observations is presented, with attention to photoelectric-photographic methods. These observations suggest a quiescent spectral class near Ko, i.e., a dwarf at a distance of 1.6 kpc. The more intense X-ray emissions are said to be generated from internal heating of the stellar atmosphere, with additional energy supplied by a low-mass companion star. This explaination is at variance with the semi-detached Roche model.

Margon, B.↗

Calibration of the Soft X-ray Telescopes (SXT) Onboard the ASTRO-H Satellite

ASTRO-H is an astrophysics satellite dedicated for non-dispersive X-ray spectroscopic study on selective celestial X-ray sources. Among the onboard instruments there are four Wolter-I X-ray mirrors of their reflectors' figure in conical approximation. Two of the four are soft X-ray mirrors, of which the energy range is from a few hundred eV to 15 keV. The focal point instruments will be a calorimeter (SXS) and a CCD camera (SXI), respectively. The mirrors were in quadrant configuration with photons being reflected consecutively in the primary and secondary stage before landing on the focal plane of 5.6 m away from the interface between the two stages. The reflectors of the mirror are made of heat-formed aluminum substrate of the thickness gauged of 152 m, 229 m, and 305 m of the alloy 5052 H-19, followed by epoxy replication on gold-sputtered smooth Pyrex cylindrical mandrels to acquire the X-ray reflective surface. The epoxy layer is 10 m nominal and surface gold layer of 0.2 m. Improvements on angular response over its predecessors, e.g. Astro-E1/Suzaku mirrors, come from error reduction on the figure, the roundness, and the grazing angle/radius mismatching of the reflecting surface, and tighter specs and mechanical strength on supporting structure to reduce the reflector positioning and the assembly errors. Each soft x-ray telescope (SXT), FM1 or FM2, were integrated from four independent quadrants of mirrors. The stray-light baffles, in quadrant configuration, were mounted onto the integrated mirror. Thermal control units were attached to the perimeter of the integrated mirror to keep the mirror within operating temperature in space. The completed instrument went through a series of optical alignment, thus made the quadrant images confocal and their optical axes in parallel to achieve highest throughput possible. Environmental tests were carried out, and optical quality of the telescopes has been confirmed. The optical and x-ray calibrations also include: angular resolution, effective area in the energy range of ~ 0.4 - 12keV, off-axis response, etc. Some of those are being carried out by our counterpart at JAXA/ISAS, Japan. We report the calibration results of the FM1 and FM2 that were obtained at Goddard Space Flight Center.

ASTRO-H Satellite↗

The internal reference source (IRS) for diffuse infrared background experiment (DIRBE)

A means is described for providing internal calibration for the detectors for DIRBE, which is the Diffuse Infrared Background Experiment (a part of the Cosmic Background Explorer). The internal reference source (IRS) that is used consists of four thermal graybody sources coupled to an integrating sphere. The relative insensitivity of the DIRBE bolometers and the linear temperature dependence of the Rayleigh-Jeans law made bolometer stimulation over five orders of magnitude difficult, so four different sources were used with emitting areas varying by a factor of 10 to the 8th. A low heat capacity design with the necessary stability appears to be thin nichrome films on a sapphire substrate. Voltage stability to 0.01 percent is required for those near infrared bands that required stimulation on the Wien portion of the blackbody curve.

Silverglate, P.↗

Global Warming Estimation from MSU

Microwave Sounding Unit (MSU) radiometer observations in Ch 2 (53.74 GHz) from sequential, sun-synchronous, polar-orbiting NOAA satellites contain small systematic errors. Some of these errors are time-dependent and some are time-independent. Small errors in Ch 2 data of successive satellites arise from calibration differences. Also, successive NOAA satellites tend to have different Local Equatorial Crossing Times (LECT), which introduce differences in Ch 2 data due to the diurnal cycle. These two sources of systematic error are largely time independent. However, because of atmospheric drag, there can be a drift in the LECT of a given satellite, which introduces time-dependent systematic errors. One of these errors is due to the progressive chance in the diurnal cycle and the other is due to associated chances in instrument heating by the sun. In order to infer global temperature trend from the these MSU data, we have eliminated explicitly the time-independent systematic errors. Both of the time-dependent errors cannot be assessed from each satellite. For this reason, their cumulative effect on the global temperature trend is evaluated implicitly. Christy et al. (1998) (CSL). based on their method of analysis of the MSU Ch 2 data, infer a global temperature cooling trend (-0.046 K per decade) from 1979 to 1997, although their near nadir measurements yield near zero trend (0.003 K/decade). Utilising an independent method of analysis, we infer global temperature warmed by 0.12 +/- 0.06 C per decade from the observations of the MSU Ch 2 during the period 1980 to 1997.

Prabhakara, C.↗

Bayesian Inference and the Effects of Varying Uncertainty Models in Charring Ablator Calibration and Uncertainty Quantification Problems

The Mars Science Laboratory (MSL) vehicle utilized a heat shield constructed from NASA’s Phenolic-Impregnated Carbon Ablator (PICA) material to protect the main structure from the high enthalpy environment encountered during hypersonic atmospheric entry. During the vehicle’s descent through Martian atmosphere, multiple thermocouples embedded within the heat shield captured in-depth material temperature data that allow for studies to be conducted on current material response reconstruction tools. In the present work, material temperature data obtained from thermocouples within the MISP-4 plug (MEDLI (Mars Science Laboratory Entry, Descent, and Landing Instrument) Integrated Sensor Plug) are utilized in the calibration of Theoretical Ablative Composite for Open Testing (TACOT) model parameters in conjunction with NASA’s Porous material Analysis Toolbox (PATO) through Bayesian inference where uncertainty due to parametric, modeling, and experimental sources is simultaneously quantified. Prior to the study, a sensitivity analysis is performed through computation of the robust Sobol indices in an effort to study the relationship between input space and model response and to reduce the dimensionality of the statistical inverse problem. The Bayesian inference methodology necessitates an a-priori choice to be made for the uncertainty model for which numerous possibilities are available. Across most works, however, only basic additive or multiplicative models are utilized with pre-defined magnitudes of uncertainty based on a-priori knowledge or to-be-calibrated multipliers of static covariance matrix structures. The present effort explores the effects of informed uncertainty models, ones with temporal dependence that are simultaneously calibrated through Bayesian inference, on calibrated results for parameters that make up the uncertain input space.

Sensitivity Analysis↗

Sea surface temperatures from the scanning multichannel microwave radiometer on Nimbus 7

Because of problems with the design and calibration of the scanning multichannel microwave radiometer (SMMR) on Nimbus 7, sea surface temperature (SST) algorithms had to be developed that corrected for instrument effects. Several stages of this development are reported here. The quality of the SST products from the final version is assessed. Thirty-four months of data have been analyzed; the average SST error is about 1.12 C over the whole globe. The error is smaller in the equatorial region and larger in the northern oceans. The main source of error is due to heating of the SMMR instrument. Specific problems in the design of the instrument are discussed. The details of the ST algorithms are given in an appendix.

Milman, A. S.↗

Solar measurements from the Airglow-Solar Spectrometer Instrument (ASSI) on the San Marco 5 satellite

The analysis of the solar spectral irradiance from the Airglow-Solar Spectrometer Instrument (ASSI) on the San Marco 5 satellite is the focus for this research grant. A pre-print copy of the paper describing the calibrations of and results from the San Marco ASSI is attached to this report. The calibration of the ASSI included (1) transfer of photometric calibration from a rocket experiment and the Solar Mesosphere Explorer (SME), (2) use of the on-board radioactive calibration sources, (3) validation of the ASSI sensitivity over its field of view, and (4) determining the degradation of the spectrometers. We have determined that the absolute values for the solar irradiance needs adjustment in the current proxy models of the solar UV irradiance, and the amount of solar variability from the proxy models are in reasonable agreement with the ASSI measurements. This research grant also has supported the development of a new solar EUV irradiance proxy model. We expected that the magnetic flux is responsible for most of the heating, via Alfen waves, in the chromosphere, transition region, and corona. From examining time series of solar irradiance data and magnetic fields at different levels, we did indeed find that the chromospheric emissions correlate best with the large magnetic field levels.

Woods, Thomas N.↗

NASA Tech Briefs, December 2006

Topic include: Inferring Gear Damage from Oil-Debris and Vibration Data; Forecasting of Storm-Surge Floods Using ADCIRC and Optimized DEMs; User Interactive Software for Analysis of Human Physiological Data; Representation of Serendipitous Scientific Data; Automatic Locking of Laser Frequency to an Absorption Peak; Self-Passivating Lithium/Solid Electrolyte/Iodine Cells; Four-Quadrant Analog Multipliers Using G4-FETs; Noise Source for Calibrating a Microwave Polarimeter; Hybrid Deployable Foam Antennas and Reflectors; Coating MCPs with AlN and GaN; Domed, 40-cm-Diameter Ion Optics for an Ion Thruster; Gesture-Controlled Interfaces for Self-Service Machines; Dynamically Alterable Arrays of Polymorphic Data Types; Identifying Trends in Deep Space Network Monitor Data; Predicting Lifetime of a Thermomechanically Loaded Component; Partial Automation of Requirements Tracing; Automated Synthesis of Architecture of Avionic Systems; SSRL Emergency Response Shore Tool; Wholly Aromatic Ether-Imides as n-Type Semiconductors; Carbon-Nanotube-Carpet Heat-Transfer Pads; Pulse-Flow Microencapsulation System; Automated Low-Gravitation Facility Would Make Optical Fibers; Alignment Cube with One Diffractive Face; Graphite Composite Booms with Integral Hinges; Tool for Sampling Permafrost on a Remote Planet; and Special Semaphore Scheme for UHF Spacecraft Communications.

Source record↗

The Process of Developing a Multi-Cell KEMS Instrument

Multi-cell KEMS offers many advantages over single cell instruments in regard to in-situ temperature calibration and studies on high temperature alloys and oxides of interest to NASA. The instrument at NASA Glenn is a 90 deg magnetic sector instrument originally designed for single cell operation. The conversion of this instrument to a multi-cell instrument with restricted collimation is discussed. For restricted collimation, the 'field aperture' is in the copper plate separating the Knudsen Cell region and the ionizer and the 'source aperture' is adjacent to the ionizer box. A computer controlled x-y table allows positioning of one of the three cells into the sampling region. Heating is accomplished via a Ta sheet element and temperature is measured via an automatic pyrometer from the bottom of the cells. The computer control and data system have been custom developed for this instrument and are discussed. Future improvements are also discussed.

Copland, E. H.↗