An experiment concept to measure stratospheric trace constituents by Laser Heterodyne Spectroscopy

The concept and techniques of a Laser Heterodyne Spectrometer experiment for measuring the vertical profiles of several stratospheric trace gases are discussed. The goal of the experiment is to develop a laser heterodyne receiver capable of measuring 2-4 gases simultaneously from Spacelab and, ultimately, from free-flying platforms. Sensitivity analyses are currently being performed for tenuous molecules such as ClO, ClONO2, NOCl, HO2, H2O2, and N2O5, although the capability exists for measuring more abundant gases, such as O3, HNO3, N2O, NO2, and CH4. Results indicate that O3 and ClO vertical profiles can be measured with an accuracy equal to or better than 95% and 80%, respectively, over the total profile. Laboratory measurements of the performance characteristics of the local oscillator and heterodyne detector are discussed with reference to 'excess-noise' and Doppler-shift effects.

Allario, F.↗

Ripplon scattering using grating heterodyne spectroscopy

Heterodyne photon spectroscopy was used for the study of the viseo-elastic properties of the liquid interface by studying the scattering from thermal ripplons. A theory of a heterodyne apparatus based on a grating is presented, and the heterodyne condition is given in terms of the parameters of the experimental set-up. Emphasis was placed on the study of the instrumental function and its influence on the measurement data. The instrumental function is not always gaussian, but its functional form depends on the parameters of the experimental set-up. An algorithm is suggested to arrive at the center frequency and half width at half height of the spectrum from the noisy experimental data, and applied to the measurement data obtained from ethanol and water surfaces.

Sirohi, R. S.↗

The laser heterodyne spectrometer - New sensor for the 80's

The paper deals with the basic concepts in optical heterodyne receivers with tunable diode lasers, operating in the thermal infrared. Simulation retrievals of vertical profiles of trace atmospheric gas species are carried out on the basis of heterodyne receiver performance parameters. Operational tests show a high signal-to-noise ratio in measuring gas absorption features. The results demonstrate the potential power of optical heterodyne receivers, and it is concluded that during the eighties they will become the major tool for measuring the earth's atmosphere and other planetary atmospheres.

Katzberg, S. J.↗

Evidence for high-altitude haze thickening on the dark side of Venus from 10-micron heterodyne spectroscopy of CO2

Infrared heterodyne spectroscopy provides data for isolated spectral lines with a spectral resolution which is small compared to the Doppler width. Heterodyne spectroscopy of CO2 lines near 10 micrometers was first reported for the atmosphere of Venus by Betz et al. (1976). The present investigation is concerned with observations of two absorption lines of (C-12)(O-16)2 conducted with an infrared heterodyne spectrometer interfaced with a solar telescope. The 10.8598-micrometer P(44) line was observed on the day side of Venus and the 10.3337-micrometer R(8) line was observed on the night side. It is shown that continuous opacity due to haze, and possible departures from vibrational LTE in CO2, are crucial considerations in fitting the observed lines.

Deming, D.↗

Tunable diode laser heterodyne spectrometer for remote observations near 8 microns

Infrared heterodyne spectroscopy is a passive technique employing coherent optical detection for the study of spectral features in remote sources. It employs optical components such as mirrors and lenses normally associated with incoherent optics, but because of it's coherent nature, it offers the advantages of ultrahigh spectral resolving power, high frequency precision, and diffraction limited field-of-view. Attention is given to the development of an ultrahigh resolution diode laser heterodyne spectrometer for observational and laboratory use. The instrument is designed for operation in the spectral range from 7.5 to 8.5 microns. A PbSe tuneable diode laser (TDL) is employed as local oscillator. A closed-cycle cooler is employed to keep the oscillator at operating temperatures in the range from 12 to 60 K. Attention is given to factors determining the TDL heterodyne sensitivity, the spectrometer design, and a survey of 8 micron observations, SiO could be detected in the sunspot spectrum.

Glenar, D. A.↗

Signal averaging limitations in heterodyne- and direct-detection laser remote sensing measurements

The improvement in measurement uncertainty brought about by the averaging of increasing numbers of pulse return signals in both heterodyne- and direct-detection lidar systems is investigated. A theoretical analysis is presented which shows the standard deviation of the mean measurement to decrease as the inverse square root of the number of measurements, except in the presence of temporal correlation. Experimental measurements based on a dual-hybrid-TEA CO2 laser differential absorption lidar system are reported which demonstrate that the actual reduction in the standard deviation of the mean in both heterodyne- and direct-detection systems is much slower than the inverse square-root dependence predicted for uncorrelated signals, but is in agreement with predictions in the event of temporal correlation. Results thus favor the use of direct detection at relatively short range where the lower limit of the standard deviation of the mean is about 2 percent, but advantages of heterodyne detection at longer ranges are noted.

Menyuk, N.↗

IR detectors - Heterodyne and direct

Recent developments in the area of wide-bandwidth infrared detectors, both for direct and heterodyne detection, are reviewed with emphasis on the differences and tradeoffs between photodiodes and photoconductors. In the direct-detection mode, where amplifier noise is an important consideration, the state-of-the-art detection noise equivalent power is approximated by 500 (B/10 MHz) pW. At short wavelengths (less than 1.7 micron), avalanche photodiodes offer superior performance, with a detection noise equivalent power of about 50 (B/10 MHz) pW. In heterodyne operation, near-ideal sensitivities of about 0.3 (B/10 MHz) pW have been achieved with 77K photodiodes. At 10 microns, HgCdTe photoconductors offer very good heterodyne performance at elevated temperatures: 2 (B/10 MHz) pW at 195 K and potentially 3 (B/10 MHz) pW at 250 K.

Spears, D. L.↗

A 150 Micron Heterodyne Spectrometer for Airborne Astronomy

The advantages of heterodyne detection for high resolution spectroscopy were long known to radio astronomers. Heterodyne spectroscopy was productive at submillimeter wavelengths, but its extension to shorter submillimeter and far-infrared (FIR) wavelengths was hampered by inadequate mixers and local oscillators. A significant advance in FIR receiver technology was demonstrated using an optically-pumped FIR laser and a Schottky-diode mixer. Any similar spectrometer intended for airborne observations at shorter wavelengths must be compatible with the more restrictive aircraft environment. The effectiveness of the design of a FIR heterodyne spectrometer was verified in ground-based observations with a prototype version. The airborne successor is even more compact, and has a much broader spectral coverage. Flight tests are scheduled for the new instrument.

Betz, A.↗

Investigation of the quantum efficiency of optical heterodyne detectors

The frequency response and quantum efficiency of optical photodetectors for heterodyne receivers is investigated. The measurements utilized two spectral lines from the output of two lasers as input to the photodetectors. These lines are easily measurable in power and frequency and hence serve as known inputs. By measuring the output current of the photodetector the quantum efficiency is determined as a function of frequency separation between the two input signals. An investigation of the theoretical basis and accuracy of this type of measurement relative to similar measurements utilizing risetime is undertaken. A theoretical study of the heterodyne process in photodetectors based on semiconductor physics is included so that higher bandwidth detectors may be designed. All measurements are made on commercially available detectors and manufacturers' specifications for normal photodetector operation are compared to the measured heterodyne characteristics.

Batchman, T. E.↗

Performance of moire deflectometry with deferred electronic heterodyne readout

The effects of diffraction and nonlinear photographic emulsion characteristics on the performance of deferred electronic heterodyne moire deflectometry are theoretically and experimentally investigated. The intensity transmission distribution of the transparency, the moire image, the heterodyne readout, and the spatial and angular resolution are analytically discussed. The deferred electronic heterodyne technique is evaluated by measuring small fringe shifts caused by a weak phase object. It is found that this technique can be applied for accurate and sensitive readout of moire fringes of unsteady phase objects. The theoretical study shows that the accuracy and sensitivity of the system are weakly affected by diffraction and nonlinear photographic emulsion characteristics. Nonlinear recording does not affect the spatial resolution of the system.

Stricker, Josef↗

Performance analysis of a noncoherently combined large aperture optical heterodyne receiver

The performance of a noncoherently combined, multiple-mirror heterodyne receiver is analyzed. It is shown that in the absence of atmospheric turbulence, the performance of the noncoherently combined receiver is inferior to that of a monolithic, diffraction-limited receiver with equivalent aperture area. However, when atmospheric turbulence is taken into consideration, the efficiency of a monolithic aperture heterodyne receiver is limited by the phase coherence length of the atmosphere and generally does not improve with increasing aperture size. In constrast, the performance of a noncoherently combined system improves with an increasing number of receivers. Consequently, given a fixed collecting area, the noncoherently combined system can offer superior performance. The performance of the noncoherently combined heterodyne receiver is studied by analyzing the combining loss of the receiver SNR. It is shown that, given the collecting area, the performance of the combined receiver is optimized when the diameter of each of the individual receivers is on the order of the phase coherence length gamma sub 0 of the atmospheric turbulence.

Chen, C.-C.↗

30-micron heterodyne receiver

Advantages and constraints of remote measurements using heterodyne spectroscopy near 30 microns are discussed. The state of the art of wideband HgCdTe photomixers and PbSnSe diode-laser local oscillators being developed for FIR heterodyne receivers is described. The first compact 30-micron heterodyne radiometer was built, and initial results at 28-microns show about 2-percent mixer efficiency for a 500-MHz-bandwidth receiver. Factors limiting receiver performance are discussed, along with the projected sensitivity of new interdigitated-electrode HgCdTe photoconductor mixers being developed for operation up to 200 microns.

Kostiuk, Theodor↗

Deferred electronic heterodyne moire deflectometry: A method for transient density fields measurement

Effects of spherical aberrations of the mirror used in the moire system on the angular resolution of the system are investigated. It is shown that the spherical aberrations may reduce significantly the performance of the conventional moire deflectometer. However, due to the heterodyne procedure, this is not the case with the heterodyne moire system. A moire system with a constant speed moving grating is demonstrated. It is shown that the system readout is linear and the system does not need calibration. In addition, the repeatability of the measurements is improved in this system as compared to the sinusoidally moving grating setup. The problem of the photographic plates alignment is solved by using a mechanical system in which the plate is held firmly throughout the experiment and accurately replaced after removing for photographic processing. The effect of a circular detector's aperture size on readout was tested. It is shown that the spatial phase variations, observed when scanning along a straight moire fringe, may considerably be reduced. At present we may say that both the on-line and the deferred heterodyne moire techniques may reliably be used. The errors of phase readings are 1 deg and 5 deg for the on-line and deferred methods. The total error due to subtraction of two readings at each position is, therefore, 1.4 deg and 7 deg, respectively. Further research for improving the deferred system is suggested.

Stricker, Josef↗

Appendix: Limits on the use of heterodyning and amplification in optical interferometry

The development of optical fibers, lasers, and mixers at optical frequencies has offered the hope that active methods can contribute to optical interferometry. Heterodyning, in particular, looks attractive, even though bandwidths are narrower than one would like at present; one might expect this limitation to lessen as technology develops. That expectation, unfortunately, is not likely to benefit interferometry at optical wavelengths because of the intervention of quantum mechanics and the second law of thermodynamics, as Burke (1985a) pointed out. So much 'second quantization' noise is generated that only at infrared frequencies, somewhere in the 10-100 micron range, can one look forward to heterodyning in any realistic sense. The reason is easily understood. Every amplifier, in the quantum limit, works by stimulated emission, even though this basic truth is not obvious at radio frequencies. This means that there must be spontaneous emission occurring within every amplifier, and Strandberg (1957) showed that this implied a limiting noise temperature, T sub N = h nu/k, for any amplifier. Burke (1969) used this result to demonstrate that, if it were not for this quantum noise, the VLBI method would allow one to tell which slit a photon went through before forming an interference pattern, thus violating basic tenants of quantum mechanics. In essence, the second quantization condition Delta N Delta phi greater than or = 1 saves one from paradox. One can state the conclusion simply: any amplifier produces approximately one photon per Hertz of bandwidth. In optical interferometry, one will certainly want bandwidth in the 10(exp 12) to 10(exp 14) Hz range, and that implies an intolerable cacophony of noise photons. Only at infrared frequencies can one tolerate the quantum noise, where the natural noise background may be high and the mixers are not as efficient as one would hope for. The crossover at present is about 10 or 20 microns, but the boundary will shift to longer wavelengths as noise performance improves. One might guess that ultimately a wavelength of about 100 microns will mark the limit of useful amplification and heterodyning in astronomical aperture synthesis interferometry.

Burke, Bernard F.↗

Heterodyne Spectroscopy in the Thermal Infrared Region: A Window on Physics and Chemistry

The thermal infrared region contains molecular bands of many of the most important species in gaseous astronomical sources. True shapes and frequencies of emission and absorption spectral lines from these constituents of planetary and stellar atmospheres contain unique information on local temperature and abundance distribution, non-thermal effects, composition, local dynamics and winds. Heterodyne spectroscopy in the thermal infrared can remotely measure true line shapes in relatively cool and thin regions and enable the retrieval of detailed information about local physics and chemistry. The concept and techniques for heterodyne detection will be discussed including examples of thermal infrared photomixers and instrumentation used in studies of several astronomical sources. Use of heterodyne detection to study non-LTE phenomena, planetary aurora, minor planetary species and gas velocities (winds) will be discussed. A discussion of future technological developments and relation to space flight missions will be addressed.

Kostiuk, Theodor↗

Optimum Integrated Heterodyne Photoreceiver for Coherent Lidar Applications

Many coherent lidar applications, particularly airborne and space-based applications, impose stringent power and size constraints while requiring high levels of sensitivity. For this reason, optimization of the lidar heterodyne photoreceiver is one of the critical steps in ensuring full utilization of limited resources to achieve the required sensitivity. The analysis of 2-micron heterodyne receivers shows that substantial improvement of the order of 3 dB can be obtained by proper optimization of the receiver key control parameters and elimination of its parasitic capacitances by integrating the detector, its bias circuit, and the preamplifier on a single substrate. This paper describes analytical steps for defining optimum heterodyne receiver design parameters and development of experimental devices operating at 2-micron wavelength.

Amzajerdian, Farzin↗

Fiber-optic delay-line stabilization of heterodyne optical signal generator and method using same

The present invention is a laser heterodyne frequency generator system with a stabilizer for use in the microwave and millimeter-wave frequency ranges utilizing a photonic mixer as a photonic phase detector in a stable optical fiber delay-line. Phase and frequency fluctuations of the heterodyne laser signal generators are stabilized at microwave and millimeter wave frequencies by a delay line system operating as a frequency discriminator. The present invention is free from amplifier and mixer 1/.function. noise at microwave and millimeter-wave frequencies that typically limit phase noise performance in electronic cavity stabilized electronic oscillators. Thus, 1/.function. noise due to conventional mixers is eliminated and stable optical heterodyne generation of electrical signals is achieved.

Logan, Ronald T.↗

Mars Ozone Absorption Line Shapes from Infrared Heterodyne Spectra Applied to GCM-Predicted Ozone Profiles and to MEX/SPICAM Column Retrievals

We present the application of infrared heterodyne line shapes of ozone on Mars to those produced by radiative transfer modeling of ozone profiles predicted by general circulation models (GCM), and to contemporaneous column abundances measured by Mars Express SPICAM. Ozone is an important tracer of photochemistry Mars' atmosphere, serving as an observable with which to test predictions of photochemistry-coupled GCMs. Infrared heterodyne spectroscopy at 9.5 microns with spectral resolving power >1,000,000 is the only technique that can directly measure fully-resolved line shapes of Martian ozone features from the surface of the Earth. Measurements were made with Goddard Space Flight Center's Heterodyne instrument for Planetary Wind And Composition (HIPWAC) at the NASA Infrared Telescope Facility (IRTF) on Mauna Kea, Hawaii on February 21-24 2008 UT at Ls=35deg on or near the MEX orbital path. The HIPWAC observations were used to test GCM predictions. For example, a GCM-generated ozone profile for 60degN 112degW was scaled so that a radiative transfer calculation of its absorption line shape matched an observed HIPWAC absorption feature at the same areographic position, local time, and season. The RMS deviation of the model from the data was slightly smaller for the GCM-generated profile than for a line shape produced by a constant-with-height profile, even though the total column abundances were the same, showing potential for testing and constraining GCM ozone-profiles. The resulting ozone column abundance from matching the model to the HIPWAC line shape was 60% higher than that observed by SPICAM at the same areographic position one day earlier and 2.5 hours earlier in local time. This could be due to day-to-day, diurnal, or north polar region variability, or to measurement sensitivity to the ozone column and its distribution, and these possibilities will be explored. This work was supported by NASA's Planetary Astronomy Program.

Fast, Kelly E.↗